Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Cardiovasc Electrophysiol ; 28(7): 796-805, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28429529

RESUMEN

INTRODUCTION: Inappropriate implantable cardioverter-defibrillator (ICD) shocks, commonly caused by atrial fibrillation (AF), are associated with an increased mortality. Because impaired left atrial (LA) function predicts development of AF, we hypothesized that impaired LA function predicts inappropriate shocks beyond a history of AF. METHODS AND RESULTS: We prospectively analyzed the association between LA function and incident inappropriate shocks in primary prevention ICD candidates. In the Prospective Observational Study of ICD (PROSE-ICD), we assessed LA function using tissue-tracking cardiac magnetic resonance (CMR) prior to ICD implantation. A total of 162 patients (113 males, age 56 ± 15 years) were included. During the mean follow-up of 4.0 ± 2.9 years, 26 patients (16%) experienced inappropriate shocks due to AF (n = 19; 73%), supraventricular tachycardia (n = 5; 19%), and abnormal sensing (n = 2; 8%). In univariable analyses, inappropriate shocks were associated with AF history prior to ICD implantation, age below 70 years, QRS duration less than 120 milliseconds, larger LA minimum volume, lower LA stroke volume, lower LA emptying fraction, impaired LA maximum and preatrial contraction strains (Smax and SpreA ), and impaired LA strain rate during left ventricular systole and atrial contraction (SRs and SRa ). In multivariable analysis, impaired Smax (hazard ratio [HR]: 0.96, P = 0.044), SpreA (HR: 0.94, P = 0.030), and SRa (HR: 0.25, P < 0.001) were independently associated with inappropriate shocks. The receiver-operating characteristics curve showed that SRa improved the predictive value beyond the patient demographics including AF history (P = 0.033). CONCLUSION: Impaired LA function assessed by tissue-tracking CMR is an independent predictor of inappropriate shocks in primary prevention ICD candidates beyond AF history.


Asunto(s)
Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Función del Atrio Izquierdo/fisiología , Desfibriladores Implantables/efectos adversos , Prevención Primaria/métodos , Adulto , Anciano , Fibrilación Atrial/prevención & control , Desfibriladores Implantables/tendencias , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Prevención Primaria/tendencias , Estudios Prospectivos
2.
J Trauma Acute Care Surg ; 93(6): 838-845, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-35393381

RESUMEN

BACKGROUND: Trauma-induced secondary cardiac injury has been associated with significant adverse cardiovascular events. Speckle tracking echocardiography is a novel technology that allows an accurate and reproducible cardiac structure and function assessment. We evaluated the left ventricle (LV) myocardial deformation by speckle tracking echocardiography in a hemorrhagic shock (HS) swine model. METHODS: Seven healthy male Landrace pigs were included in this study. Severe HS was reached through three sequentially blood withdraws of 20% of estimated blood volume, and it was maintained for 60 minutes. Volume resuscitation was performed using all precollected blood volume. A 1.8- to 4.2-MHz phased-array transducer was used to acquire the two-dimensional echocardiography images. Strain measurements were obtained semiautomatically by wall motion tracking software. Results are presented as medians and interquartile ranges and compared using Wilcoxon rank-sum test. A p value of <0.05 was considered statistically significant. RESULTS: The median weight was 32 (26.1-33) kg, and the median total blood volume withdrawn was 1,100 (1,080-1,190) mL. During the severe HS period, the median arterial systemic pressure was 39 (36-46) mm Hg, and the cardiac index was 1.7 (1.6-2.0) L/min/m 2 . There was statistically significant absolute decrease in the global longitudinal strain 2 hours postresuscitation comparing with the basal measurements (-9.6% [-10.7 to -8.0%] vs. -7.9% [-8.1 to -7.4%], p = 0.03). There were no statistically significant differences between the basal and 2 hours postresuscitation assessments in the invasive/noninvasive hemodynamic, other two-dimensional echocardiogram (LV ejection fraction, 49.2% [44-54.3%] vs. 53.2% [51.5-55%]; p = 0.09), and circumferential strain (-10.6% [-14.4 to -9.0%] vs. -8.5% [-8.6 to -5.2%], p = 0.06) parameters. CONCLUSION: In this experimental swine model of controlled HS, LV global longitudinal strain analysis accurately characterizes the timing and magnitude of subclinical cardiac dysfunction associated with trauma-induced secondary cardiac injury.


Asunto(s)
Ecocardiografía Tridimensional , Choque Hemorrágico , Masculino , Porcinos , Animales , Ventrículos Cardíacos/diagnóstico por imagen , Ecocardiografía Tridimensional/métodos , Choque Hemorrágico/diagnóstico por imagen , Reproducibilidad de los Resultados , Ecocardiografía/métodos
3.
Sci Rep ; 11(1): 22683, 2021 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-34811411

RESUMEN

Better models to identify individuals at low risk of ventricular arrhythmia (VA) are needed for implantable cardioverter-defibrillator (ICD) candidates to mitigate the risk of ICD-related complications. We designed the CERTAINTY study (CinE caRdiac magneTic resonAnce to predIct veNTricular arrhYthmia) with deep learning for VA risk prediction from cine cardiac magnetic resonance (CMR). Using a training cohort of primary prevention ICD recipients (n = 350, 97 women, median age 59 years, 178 ischemic cardiomyopathy) who underwent CMR immediately prior to ICD implantation, we developed two neural networks: Cine Fingerprint Extractor and Risk Predictor. The former extracts cardiac structure and function features from cine CMR in a form of cine fingerprint in a fully unsupervised fashion, and the latter takes in the cine fingerprint and outputs disease outcomes as a cine risk score. Patients with VA (n = 96) had a significantly higher cine risk score than those without VA. Multivariate analysis showed that the cine risk score was significantly associated with VA after adjusting for clinical characteristics, cardiac structure and function including CMR-derived scar extent. These findings indicate that non-contrast, cine CMR inherently contains features to improve VA risk prediction in primary prevention ICD candidates. We solicit participation from multiple centers for external validation.


Asunto(s)
Arritmias Cardíacas/etiología , Arritmias Cardíacas/prevención & control , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/terapia , Desfibriladores Implantables/efectos adversos , Imagen por Resonancia Cinemagnética/métodos , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/terapia , Prevención Primaria/métodos , Anciano , Cicatriz/diagnóstico por imagen , Toma de Decisiones Clínicas/métodos , Aprendizaje Profundo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Factores de Riesgo , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda
4.
J Am Soc Echocardiogr ; 33(7): 878-887.e3, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32336609

RESUMEN

BACKGROUND: The relationship between long-term obesity and left atrial (LA) structure and function is not entirely understood. We examined the association of cumulative body mass index (cBMI) with LA remodeling using three-dimensional (3D) speckle-tracking echocardiography (STE). METHODS: The Coronary Artery Risk Development in Young Adults (CARDIA) study is a community-based cohort of black and white, men and women, ages 18-30 years at baseline in 1985-86 from four U.S. centers. This study included 2,144 participants who had satisfactory image quality and body mass index measurements during the entire follow-up period. The 3D STE-derived LA parameters were maximum, minimum, and pretrial contraction volumes; total, passive, and active emptying fraction; maximum systolic longitudinal strain; and early and late diastolic longitudinal strain rates. Multivariable linear regression analyses stratified by sex assessed the relationship between cBMI and 3D STE-derived LA parameters, adjusting for demographics and traditional cardiovascular. RESULTS: The mean age of the cohort was 55 ± 3.6 years; 54.8% were women, and 46.5% were black. There were statistically significant additive sex interactions for the association between cBMI and LA minimum contraction value, maximum systolic longitudinal strain, and early and late diastolic longitudinal strain rates. In the fully adjusted model, greater cBMI was associated with lower magnitude LA longitudinal deformation (maximum systolic longitudinal strain and early and late diastolic longitudinal strain rates) in men and with higher LA emptying fraction in women. In addition, greater cBMI was associated with higher LA phasic volumes indices in both men and women. CONCLUSIONS: This study showed that while greater cBMI from early adulthood throughout middle age was associated with higher LA volumes in both genders, differences were found for LA function, with lower longitudinal deformation in men and higher reservoir and active LA function in women.


Asunto(s)
Remodelación Atrial , Ecocardiografía Tridimensional , Adolescente , Adulto , Índice de Masa Corporal , Vasos Coronarios , Femenino , Humanos , Recién Nacido , Masculino , Persona de Mediana Edad , Caracteres Sexuales , Adulto Joven
5.
Magn Reson Imaging ; 42: 130-138, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28642098

RESUMEN

PURPOSE: Left atrial (LA) structure and function are important markers of adverse cardiovascular outcomes. Tissue-tracking cardiovascular magnetic resonance (CMR) accurately quantifies LA volume, strain, and strain rate based on biplane long-axis imaging. We aimed to assess the accuracy of the LA indices quantification from single-plane tissue-tracking CMR. METHODS: We included 388 subjects (mean age 57±13, male 70%) whose cine CMR images in sinus rhythm were available in both four-chamber and two-chamber views: 162 patients from the Prospective Observational Study of Implantable Cardioverter-Defibrillators (PROSE-ICD) Study, 208 patients from atrial fibrillation cohort, and 18 healthy volunteers. The group was divided into the training set (n=291) and the test set (n=97). In the training set, we compared the LA indices derived from biplane imaging and single-plane imaging (a four-chamber view), and developed regression equations. In the test set, we used the regression equations to estimate the LA indices from the single-plane imaging, and quantified the accuracy of the estimation against the LA indices from the biplane. RESULTS: In the training set, all the LA indices from the single-plane imaging tended to be systematically underestimated compared with those from the biplane imaging, however, the correlation coefficient was high (r2=0.73-0.90, p<0.001). In the test set, LA volumetric indices showed excellent reproducibility (intra-class correlation coefficient (ICC): 0.91-0.92) with relatively low variability (16.3-22.3%); For LA strain and strain rate indices, reproducibility was excellent (ICC: 0.81-0.93), however, the variability was slightly higher than that of volumetric indices (21.7-25.4%). CONCLUSIONS: LA volumetric indices measured from single-plane tissue-tracking CMR are highly accurate and reproducible with reference to those derived from the standard biplane imaging. The reproducibility of LA strain and strain rate indices from single-plane tissue-tracking CMR is excellent but the variability is higher than that of the volumetric indices.


Asunto(s)
Función del Atrio Izquierdo/fisiología , Atrios Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética , Adulto , Anciano , Fibrilación Atrial/diagnóstico por imagen , Femenino , Atrios Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Estudios Prospectivos , Análisis de Regresión , Reproducibilidad de los Resultados , Estrés Mecánico
6.
PLoS One ; 12(7): e0179459, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28678805

RESUMEN

Persistent atrial fibrillation (AF) can be viewed as disintegrated patterns of information transmission by action potential across the communication network consisting of nodes linked by functional connectivity. To test the hypothesis that ablation of persistent AF is associated with improvement in both local and global connectivity within the communication networks, we analyzed multi-electrode basket catheter electrograms of 22 consecutive patients (63.5 ± 9.7 years, 78% male) during persistent AF before and after the focal impulse and rotor modulation-guided ablation. Eight patients (36%) developed recurrence within 6 months after ablation. We defined communication networks of AF by nodes (cardiac tissue adjacent to each electrode) and edges (mutual information between pairs of nodes). To evaluate patient-specific parameters of communication, thresholds of mutual information were applied to preserve 10% to 30% of the strongest edges. There was no significant difference in network parameters between both atria at baseline. Ablation effectively rewired the communication network of persistent AF to improve the overall connectivity. In addition, successful ablation improved local connectivity by increasing the average clustering coefficient, and also improved global connectivity by decreasing the characteristic path length. As a result, successful ablation improved the efficiency and robustness of the communication network by increasing the small-world index. These changes were not observed in patients with AF recurrence. Furthermore, a significant increase in the small-world index after ablation was associated with synchronization of the rhythm by acute AF termination. In conclusion, successful ablation rewires communication networks during persistent AF, making it more robust, efficient, and easier to synchronize. Quantitative analysis of communication networks provides not only a mechanistic insight that AF may be sustained by spatially localized sources and global connectivity, but also patient-specific metrics that could serve as a valid endpoint for therapeutic interventions.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Electrocardiografía/métodos , Sistema de Conducción Cardíaco/cirugía , Anciano , Algoritmos , Fibrilación Atrial/fisiopatología , Femenino , Corazón/fisiopatología , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/cirugía , Sistema de Conducción Cardíaco/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Recurrencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA