1.
J Phys Conf Ser ; 250(1): 398-402, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21617738

RESUMEN

The United Kingdom's National Nuclear Laboratory (NNL) has developed a radiation-mapping device that can locate and quantify radioactive hazards within contaminated areas of the nuclear industry. The device, known as RadBall(™), consists of a colander-like outer collimator that houses a radiation-sensitive polymer sphere. The collimator has over two hundred small holes; thus, specific areas of the polymer sphere are exposed to radiation becoming increasingly more opaque in proportion to the absorbed dose. The polymer sphere is imaged in an optical-CT scanner that produces a high resolution 3D map of optical attenuation coefficients. Subsequent analysis of the optical attenuation data provides information on the spatial distribution of sources in a given area forming a 3D characterization of the area of interest. The RadBall(™) technology has been deployed in a number of technology trials in nuclear waste reprocessing plants at Sellafield in the United Kingdom and facilities of the Savannah River National Laboratory (SRNL). This paper summarizes the tests completed at SRNL Health Physics Instrument Calibration Laboratory (HPICL).

2.
J Phys Conf Ser ; 250(1): 403-407, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21617740

RESUMEN

The United Kingdom's National Nuclear Laboratory (NNL) has developed a remote, non-electrical, radiation-mapping device known as RadBall(™), which can locate and quantify radioactive hazards within contaminated areas of the nuclear industry. RadBall(™) consists of a colander-like outer shell that houses a radiation-sensitive polymer sphere. The outer shell works to collimate radiation sources and those areas of the polymer sphere that are exposed react, becoming increasingly more opaque, in proportion to the absorbed dose. The polymer sphere is imaged in an optical-CT scanner, which produces a high resolution 3D map of optical attenuation coefficients. Subsequent analysis of the optical attenuation matrix provides information on the spatial distribution of sources in a given area forming a 3D characterization of the area of interest. RadBall(™) has no power requirements and can be positioned in tight or hard-to reach locations. The RadBall(™) technology has been deployed in a number of technology trials in nuclear waste reprocessing plants at Sellafield in the United Kingdom and facilities of the Savannah River National Laboratory (SRNL). This study focuses on the RadBall(™) testing and modeling accomplished at SRNL.

3.
Health Phys ; 104(1): 63-7, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23192088

RESUMEN

RadBall is a novel, passive, radiation detection device that provides 3D mapping of radiation from areas where measurements have not been possible previously due to lack of access or extremely high radiation doses. This kind of technology is beneficial when decommissioning and decontamination of nuclear facilities occur. The key components of the RadBall technology include a tungsten outer shell that houses a radiosensitive PRESAGE polymer. The 1.0-cm-thick tungsten shell has a number of holes that allow photons to reach the polymer, thus generating radiation tracks that are analyzed to characterize the radiation sources within the contaminated area being considered. Facilities being mapped frequently have to be shut down to minimize radiation exposures to workers; therefore, reducing the mapping or characterization time is significant. The objective of this study was to reduce the RadBall deployment time by increasing the radiosensitivity of the PRESAGE formulation. The new formulation is four times more radiosensitive than the original formulation. Consequently, RadBall deployment times can be reduced fourfold, which is a considerable improvement.


Asunto(s)
Poliuretanos/química , Monitoreo de Radiación/instrumentación , Tolerancia a Radiación , Humanos
4.
Health Phys ; 103(1): 100-6, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22647921

RESUMEN

The overall objective of this study was to demonstrate that a new technology, known as RadBall®, could locate submerged radiological hazards. RadBall® is a novel, passive, radiation detection device that provides a 3-D visualization of radiation from areas where measurements have not been previously possible due to lack of access or extremely high radiation doses. This technology has been under development during recent years, and all of its previous tests have included dry deployments. This study involved, for the first time, underwater RadBall® deployments in hot cells containing 137CsCl capsules at the U.S. Department of Energy's Hanford Site. RadBall® can be used to characterize a contaminated room, hot cell, or glovebox by providing the locations of the radiation sources and hazards, identifying the radionuclides present within the cell, and determining the radiation sources' strength (e.g., intensities or dose rates). These parameters have been previously determined for dry deployments; however, only the location of radiation sources and hazards can be determined for an underwater RadBall® deployment. The results from this study include 3-D images representing the location of the radiation sources within the Hanford Site cells. Due to RadBall®'s unique deployability and non-electrical nature, this technology shows significant promise for future characterization of radiation hazards prior to and during the decommissioning of contaminated nuclear facilities.


Asunto(s)
Cesio/análisis , Cloruros/análisis , Reactores Nucleares , Monitoreo de Radiación/instrumentación , Contaminantes Radiactivos/análisis , Cápsulas , Inmersión , Washingtón