1.
Vasc Endovascular Surg ; 58(5): 530-534, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38153161

RESUMEN

This report demonstrates the successful treatment of a carotid artery pseudoaneurysm using percutaneous thrombin injection. The patient, a 62-year-old woman with multiple comorbidities, experienced a pseudoaneurysm following an unintentional carotid artery puncture during a failed attempt to place a triple lumen catheter in the right jugular vein. Percutaneous thrombin injection was chosen as the treatment method, with Doppler ultrasound monitoring. Follow-up examinations showed no signs of recurrence, and the patient was discharged after nine days without complications.


Asunto(s)
Traumatismos de las Arterias Carótidas , Enfermedad Iatrogénica , Punciones , Trombina , Lesiones del Sistema Vascular , Humanos , Trombina/administración & dosificación , Femenino , Persona de Mediana Edad , Resultado del Tratamiento , Traumatismos de las Arterias Carótidas/diagnóstico por imagen , Traumatismos de las Arterias Carótidas/tratamiento farmacológico , Traumatismos de las Arterias Carótidas/etiología , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/tratamiento farmacológico , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/tratamiento farmacológico , Aneurisma Falso/etiología , Hemostáticos/administración & dosificación , Hemostáticos/efectos adversos , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/instrumentación , Venas Yugulares/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Ultrasonografía Doppler
2.
Phys Eng Sci Med ; 47(2): 643-649, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38294678

RESUMEN

CT angiography prior to endovascular aortic surgery is the standard non-invasive imaging method for evaluation of aortic dimensions and access sites. A detailed report is crucial to a proper planning. We assessed Artificial Intelligence (AI)-algorithm accuracy to measure vessels diameters at CT prior to transcatheter aortic valve implantation (TAVI). CT scans of 50 patients were included. Two Radiologists with experience in vascular imaging together manually assessed diameters at nine landmark positions according to the American Heart Association guidelines: 450 values were obtained. We implemented TOST (Two One-Sided Test) to determine whether the measurements were equivalent to the values obtained from the AI algorithm. When the equivalence bound was a range of ± 2 mm the test showed equivalence for every point; if the range was equal to ± 1 mm the two measurements were not equivalent in 6 points out of 9 (p-value > 0.05), close to the aortic valve. The time for automatic evaluation (average 1 min 47 s) was significantly lower compared with manual measurements (5 min 41 s) (p < 0.01). In conclusion, our results indicate that AI-algorithms can measure aortic diameters at CT prior to endovascular surgery with high accuracy. AI-assisted reporting promises high efficiency, reduced inter-reader variabilities and time saving. In order to perform optimal TAVI procedure planning aortic root analysis could be improved, including annulus dimensions.


Asunto(s)
Inteligencia Artificial , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Humanos , Femenino , Masculino , Anciano , Anciano de 80 o más Años , Algoritmos , Reemplazo de la Válvula Aórtica Transcatéter , Aorta/diagnóstico por imagen , Aorta/cirugía