1.
Rev Med Brux ; 37(5): 419-422, 2016.
Artículo en Francés | MEDLINE | ID: mdl-28525210

RESUMEN

Kingella kingae is a gram-negative cocci present in the oral flora ; this organism is difficult to isolate by conventional culture techniques ; it can be detected after longer incubation period (more than 6 days) in blood culture. It is responsible of various infectious diseases, especially in children below 3 years-old where it is a cause of arthritis and osteomyeli tis. It is included in HACEK organisms responsible of 2 to 3 % of all cases of native endocarditis. The case report is the case of a young women with Kingella kingae septicemia in a context of oral lesions from Coxsackie virus infection ; treatment by ciprofloxacine permit a complete resolution of symptoms. Differential diagnosis is made about conditions with oral lesions. This article is an occasion to review literature about this unusual organism and clinical presentation. Improvements in laboratory method will in the future increase incidence and prevalence of infections caused by Kingella kingae.


Le Kingella kingae est un cocci Gram-négatif présent dans la flore buccale ; c'est un organisme qui est difficile à isoler par les techniques de culture conventionnelles ; ainsi, il peut être mis en évidence après des périodes d'incubation plus longues (plus de 6 jours) dans les hémocultures. Il est responsable de diverses pathologies infectieuses, notamment chez l'enfant où il peut occasionner une arthrite ou une ostéomyélite, essentiellement en-dessous de l'âge de 3 ans. Il fait partie des organismes HACEK responsables de 2 à 3 % des endocardites infectieuses. Le cas rapporté dans cet article est celui d'une jeune femme présentant une septicémie à Kingella kingae dans un contexte de lésions buccales dues à une infection par virus Coxsackie ; un traitement antibiotique par ciprofloxacine a permis une résolution complète des symptômes. Cet article est l'occasion d'une revue de la littérature concernant cette présentation clinique et ce germe inhabituels.


Asunto(s)
Infecciones por Coxsackievirus/complicaciones , Kingella kingae/aislamiento & purificación , Infecciones por Neisseriaceae/complicaciones , Sepsis/microbiología , Adulto , Coinfección , Infecciones por Coxsackievirus/patología , Femenino , Humanos , Infecciones por Neisseriaceae/patología , Sepsis/complicaciones
2.
Eur Heart J Cardiovasc Imaging ; 25(6): 727-734, 2024 May 31.
Artículo en Inglés | MEDLINE | ID: mdl-38635738

RESUMEN

AIMS: The European Association of Cardiovascular Imaging (EACVI) Scientific Initiatives Committee performed a global survey on radiation exposure in interventional echocardiography. The survey aimed to collect data on local practices for radioprotection in interventional echocardiography and to assess the awareness of echocardiography operators about radiation-related risks. METHODS AND RESULTS: A total of 258 interventional echocardiographers from 52 different countries (48% European) responded to the survey. One hundred twenty-two (47%) participants were women. Two-thirds (76%) of interventional echocardiographers worked in tertiary care/university hospitals. Interventional echocardiography was the main clinical activity for 34% of the survey participants. The median time spent in the cath-lab for the echocardiographic monitoring of structural heart procedures was 10 (5-20) hours/month. Despite this, only 28% of interventional echocardiographers received periodic training and certification in radioprotection and 72% of them did not know their annual radiation dose. The main adopted personal protection devices were lead aprons and thyroid collars (95% and 92% of use, respectively). Dedicated architectural protective shielding was not available for 33% of interventional echocardiographers. Nearly two-thirds of responders thought that the radiation exposure of interventional echocardiographers was higher than that of interventional cardiologists and 72% claimed for an improvement in the radioprotection measures. CONCLUSION: Radioprotection measures for interventional echocardiographers are widely variable across centres. Radioprotection devices are often underused by interventional echocardiographers, portending an increased radiation-related risk. International scientific societies working in the field should collaborate to endorse radioprotection training, promote reliable radiation dose assessment, and support the adoption of radioprotection shielding dedicated to interventional echocardiographers.


Asunto(s)
Ecocardiografía , Exposición Profesional , Exposición a la Radiación , Protección Radiológica , Humanos , Femenino , Exposición Profesional/prevención & control , Exposición a la Radiación/prevención & control , Masculino , Europa (Continente) , Encuestas y Cuestionarios , Dosis de Radiación , Adulto , Persona de Mediana Edad , Ultrasonografía Intervencional
3.
Postgrad Med J ; 87(1024): 150-5, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21303821

RESUMEN

Mitral regurgitation is a frequent finding in patients with aortic stenosis scheduled for aortic valve replacement. Detection of mitral regurgitation in such patients has important implications, as it can independently affect functional status and prognosis. When mitral regurgitation is moderate to severe, a decision to operate on both valves should only be made following a careful clinical and echocardiographic assessment. Indeed, double-valve surgery increases perioperative and postoperative risks, and mitral regurgitation may improve spontaneously after isolated aortic valve replacement. Better understanding of the determinants of these changes appears particularly crucial in the light of recent advances in percutaneous aortic valve replacement.

4.
Am J Cardiol ; 71(7): 596-8, 1993 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-8438748

RESUMEN

To better elucidate the possible role of the patent foramen ovale (PFO) in patients with unexplained stroke, the relation between the incidence of stroke and 3 characteristics of PFO (timing, magnitude of appearance of echocardiographic contrast in the left atrium, and morphology of the atrial septum) was analyzed. Twenty-nine patients with unexplained stroke and 28 without stroke were compared. A significant relation was only found between the incidence of cerebrovascular accident and positive contrast echocardiography in patients with early and massive passage of contrast in the left atrium (6 of 29 [21%] in the stroke group vs 0 of 28 [0%] in the control group; p < 0.05). An abnormal morphology of the foramen ovale was found more frequently in patients with PFO than in those without PFO (9 of 13 [69%] vs 1 of 44 [2%]; p < 0.001). The results suggest the use of timing and quantification of contrast appearance in the left atrium during contrast transesophageal echocardiography, and that paradoxical embolism through a PFO is a possible mechanism of cryptogenic stroke only if there is a massive passage of contrast through an abnormal foramen ovale.


Asunto(s)
Defectos del Tabique Interatrial/complicaciones , Embolia y Trombosis Intracraneal/etiología , Adulto , Factores de Edad , Anciano , Tos/fisiopatología , Ecocardiografía , Femenino , Defectos del Tabique Interatrial/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Maniobra de Valsalva
5.
Am J Cardiol ; 86(11): 1284-7, A9, 2000 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-11090813

RESUMEN

We compared the use of transthoracic echocardiography with second harmonic imaging after a peripheral intravenous injection of an agitated saline solution with transesophageal echocardiography (TEE) in the detection of right to left shunts at the cardiac and pulmonary level. Second harmonic mode transthoracic echocardiography and TEE are equally sensitive in detecting right to left shunts in patients undergoing a daily routine TEE.


Asunto(s)
Ecocardiografía Transesofágica/métodos , Defectos del Tabique Interatrial/diagnóstico por imagen , Ultrasonografía Doppler en Color , Artefactos , Ecocardiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Tórax/diagnóstico por imagen
6.
Chest ; 105(3): 945-7, 1994 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8131572

RESUMEN

Antemortem diagnosis of cardiac metastases of a hepatocellular carcinoma is rarely observed. In a 52-year-old female patient with a history of posthepatitic cirrhosis and partial hepatectomy, transthoracic echocardiography brought to light a mass in the right atrium. After location and characterization of the tumor by transesophageal echocardiography, a transvenous biopsy confirmed the diagnosis of metastasis of a hepatocellular carcinoma.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/secundario , Ecocardiografía Transesofágica , Neoplasias Cardíacas/diagnóstico por imagen , Neoplasias Cardíacas/secundario , Neoplasias Hepáticas/patología , Femenino , Atrios Cardíacos , Humanos , Persona de Mediana Edad
7.
J Am Soc Echocardiogr ; 9(2): 190-4, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-8849616

RESUMEN

We report a case of dissection of the ventricular septum by two aneurysms of the right and left coronary sinuses of Valsalva. Transthoracic and transesophageal echocardiography allowed accurate preoperative assessment and postoperative evaluation.


Asunto(s)
Aneurisma de la Aorta/diagnóstico por imagen , Disección Aórtica/diagnóstico por imagen , Ecocardiografía Transesofágica , Ecocardiografía , Tabiques Cardíacos/diagnóstico por imagen , Seno Aórtico/diagnóstico por imagen , Adulto , Disección Aórtica/cirugía , Aneurisma de la Aorta/cirugía , Humanos , Masculino , Seno Aórtico/cirugía
8.
J Am Soc Echocardiogr ; 11(6): 643-51, 1998 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-9657404

RESUMEN

BACKGROUND: Recently, the automated cardiac output method (ACM) was introduced for the calculation of blood flow at the left ventricular outflow tract (LVOT). This study was performed to examine the possibility of using ACM for flow calculation at the level of the mitral valve and for the quantification of mitral regurgitation (MR) in vitro and in vivo. METHODS AND RESULTS: In a computer-controlled in vitro model of the human heart, aortic and mitral normal bioprosthetic valves were inserted. ACM and electromagnetic probe flow measurements correlated well at the LVOT and at the mitral level (r2 = 0.79 and 0.77, respectively). For stroke volumes ranging from 30 to 100 ml/beat, there was no statistically significant bias between ACM and electromagnetic flow probe (-1.5 and 1.3 ml for LVOT and mitral level, respectively). Limits of agreement were [-14; +11] ml and [-18; +16] ml, respectively. We evaluated 68 patients in our in vivo study. They were divided into three groups according to the results of "standard" echocardiographic Doppler methods for the semiquantification of MR: echocardiographic color Doppler cartography, intensity of the continuous wave Doppler spectra, and in some patients, pulmonary venous flow, conventional Doppler, and proximal isovelocity surface area quantitative data. Group 1 consisted of 35 patients without MR or a physiologic one; the 17 patients in group 2 had a mild MR (1-2/4) and in group 3, 16 patients with MR 3-4/4 were included. Regurgitant volume (RV) was calculated as the difference between ACM mitral flow and ACM aortic flow, and regurgitant fraction (RF) was defined as the ratio between RV and ACM mitral flow. When mitral flow was measured only from the four-chamber view, we found in group 1, RV = -0.57 (0.67) L/min and RF = -16% (19%); in group 2, RV = -0.31 (1.06) L/min and RF = -8% (19%); and in group 3, RV = 1.53 (0.94) L/min and RF = 23% (13%). RV and RF were statistically higher in group 3 compared with group 2 or group 1 (p < 0.0005), but no significant difference was found between groups 1 and 2. When mitral flow was measured by the mean value of ACM four-chamber and two-chamber views, this resulted in group 1, RV = -0.26 (0.63) L/min and RF = -8% (15%); in group 2, RV = 0.01 (1.04) L/min and RF = -2% (18%); and in group 3, RV = 2.07 (1.21) L/min and RF = 34% (19%). RV and RF were again significantly higher in group 3 (p < 0.0001). There was no significant difference between group 1 and group 2, but in group 1 RF was no longer statistically different from 0%. CONCLUSIONS: (1) In our in vitro setting, ACM is reliable both at the LVOT and at the mitral valve. (2) In the in vivo situation, some overlapping does exist between the three groups of MR. However, ACM is a very easy, rapid, and objective method to differentiate hemodynamic nonsignificant (<3/4) from significant (> or =3/4) MR. Together with other well-known methods for the quantification of MR, it should facilitate the gradation of MR in the clinical setting. The absence of significant differences between group 1 and group 2 proves that the accuracy of ACM measurements at the mitral valve needs to be ameliorated before ACM can be used as a gold standard for the noninvasive measurement of RV and RF.


Asunto(s)
Gasto Cardíaco , Ecocardiografía Doppler/métodos , Insuficiencia de la Válvula Mitral/fisiopatología , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Humanos , Válvula Mitral , Modelos Cardiovasculares , Flujo Sanguíneo Regional
9.
Clin Cardiol ; 22(5): 374-5, 1999 May.
Artículo en Inglés | MEDLINE | ID: mdl-10326173

RESUMEN

Spontaneous coronary artery dissection is a rare cause of acute myocardial infarction. It typically occurs in young women receiving oral contraceptive therapy or during the peripartum period. In the case presented here, spontaneous complete healing at angiography and the favorable outcome may support the role of conservative treatment in such patients.


Asunto(s)
Aneurisma Coronario/diagnóstico por imagen , Angiografía Coronaria , Adulto , Disección Aórtica/complicaciones , Disección Aórtica/diagnóstico por imagen , Aneurisma Coronario/complicaciones , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/etiología
10.
Clin Cardiol ; 22(1): 33-6, 1999 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-9929753

RESUMEN

BACKGROUND: Cardiac involvement in children with human immunodeficiency virus (HIV) infection is a well-known entity and occurs clinically more often in patients with advanced acquired immunodeficiency syndrome (AIDS). Autonomic dysfunction is less known, especially in children. HYPOTHESIS: The aim of this study was to asses the prevalence of cardiovascular abnormalities in a pediatric population with HIV. We also aimed to evaluate whether autonomic involvement occurs in the same population and is dependent on echocardiographic abnormalities. METHODS: The occurrence of echocardiographic abnormalities was evaluated in 22 children with HIV infection, and five noninvasive tests were performed to evaluate the presence of autonomic dysfunction. RESULTS: We found cardiac lesions in four children (18%), consisting of pericardial effusion in three children, wall motion abnormalities in three children, and acute aortic endocarditis in one child. All cardiac abnormalities were found at Stage C by Center for Disease Control (CDC) revised classification. We also found left ventricular filling pattern abnormalities consisting of E-wave maximal velocity decrease and prolonged deceleration time compatible with diastolic dysfunction. One of the five autonomic tests (Valsalva maneuver) was significantly altered, even in patients without abnormal echocardiography, suggesting mild autonomic dysfunction. CONCLUSION: The study demonstrated a high prevalence of cardiac lesions in children with HIV infection and indicated the presence of autonomic dysfunction even when there are no echocardiographically detected abnormalities.


Asunto(s)
Enfermedades del Sistema Nervioso Autónomo/etiología , Infecciones por VIH/complicaciones , VIH , Cardiopatías/etiología , Adolescente , Enfermedades del Sistema Nervioso Autónomo/diagnóstico , Enfermedades del Sistema Nervioso Autónomo/fisiopatología , Niño , Ecocardiografía Doppler , Electrocardiografía , Estudios de Seguimiento , Cardiopatías/diagnóstico por imagen , Cardiopatías/epidemiología , Hemodinámica , Humanos , Prevalencia , Pronóstico , Estudios Retrospectivos
11.
Heart ; 96(1): 9-14, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19321488

RESUMEN

Mitral regurgitation is a frequent finding in patients with aortic stenosis scheduled for aortic valve replacement. Detection of mitral regurgitation in such patients has important implications, as it can independently affect functional status and prognosis. When mitral regurgitation is moderate to severe, a decision to operate on both valves should only be made following a careful clinical and echocardiographic assessment. Indeed, double-valve surgery increases perioperative and postoperative risks, and mitral regurgitation may improve spontaneously after isolated aortic valve replacement. Better understanding of the determinants of these changes appears particularly crucial in the light of recent advances in percutaneous aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Humanos , Periodo Posoperatorio , Pronóstico , Inducción de Remisión
12.
Heart ; 96(20): 1627-32, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20937750

RESUMEN

BACKGROUND: Mitral regurgitation is frequently observed in patients undergoing aortic valve replacement (AVR) for aortic stenosis and often improves postoperatively, mainly due to left ventricular remodelling and changes in loading conditions. Aortic prosthesis-patient mismatch (PPM) is associated with poor outcome and lesser left ventricular remodelling. This study tested the hypothesis that aortic PPM affects mitral regurgitation. METHODS AND RESULTS: Echocardiography was performed preoperatively and before discharge in 42 patients with aortic stenosis undergoing isolated AVR and presenting mitral regurgitation with an effective regurgitant orifice (ERO) of 10 mm(2) or greater, as assessed by the proximal isovelocity surface area method. Postoperatively, mitral ERO and the regurgitant volume decreased from 16±5mm(2) to 12±6mm(2) (p<0.001) and from 28±8ml to 16±9ml (p<0.0001), respectively. PPM (indexed effective prosthetic valve area (EOAi) ≤0.85cm(2)/m(2)), present in 23 patients (55%), was associated with a smaller decrease in regurgitant volume (p=0.0025) and ERO (p=0.02). A functional aetiology of mitral regurgitation was associated with a larger improvement in mitral regurgitation. In the whole cohort, EOAi correlated with the changes in mitral regurgitation severity (ERO r=0.44, p=0.01; regurgitant volume r=0.47, p=0.003). However, these relationships were no longer significant in the subset of patients with functional mitral regurgitation in whom mitral regurgitation changes were mainly related to postoperative changes in mitral valve deformation. CONCLUSIONS: The presence of PPM after AVR attenuates postoperative mitral regurgitation changes, mainly in patients with organic mitral regurgitation.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral/complicaciones , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/fisiopatología , Periodo Posoperatorio , Pronóstico , Ajuste de Prótesis , Resultado del Tratamiento , Ultrasonografía
15.
Ultrasound Med Biol ; 35(1): 30-5, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18834657

RESUMEN

In small animals studies, sick animals often have a significant reduction in heart rate while under anesthesia. The influence of heart rate reduction on Doppler myocardial imaging (DMI) parameters is not known. The aim of the present study was to assess the effect of heart rate reduction on DMI parameters in a small animal model. Twenty-four rats underwent transthoracic echocardiography at baseline and during the administration of ivabradine IV. In all rats, left ventricular (LV) systolic velocity, strain and strain rate were measured in the anteroseptal and inferolateral wall segments from short axis views. In 12 rats (group A), M-mode analysis was also performed for assessment of global LV function. In the other 12 rats (groups B), contractility was quantified invasively using the end-systolic pressure-volume relation (ESPVR) and the preload recruitable stroke work (PRSW). During ivabradine, administration heart rate decreased by 18% in group A (p < 0.001) and 36% in group B (p < 0.001). There was a slight increase in LVEDD and LVESD, with no change in cardiac output or LV ejection fraction. During ivabradine administration, DMI parameters did not change significantly in any group. No significant correlation between DMI parameters and heart rate (r(2) = 0.05) or ejection time (r(2) = 0.14) could be found. The absence of changes in contractility was confirmed by the absence of change in PRSW and end-systolic elastance (Ees). In conclusion, moderate heart rate reduction did not influence DMI measurements in this specific rat model. Therefore, in the interpretation of DMI data when performing small animal studies, moderate heart rate reduction does not need to be taken into account.


Asunto(s)
Benzazepinas/farmacología , Ecocardiografía Doppler , Ecocardiografía , Frecuencia Cardíaca/efectos de los fármacos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Animales , Hemodinámica , Ivabradina , Masculino , Modelos Animales , Contracción Miocárdica/efectos de los fármacos , Ratas , Ratas Wistar , Disfunción Ventricular Izquierda/fisiopatología
16.
Eur J Nucl Med Mol Imaging ; 32(11): 1317-23, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16133394

RESUMEN

PURPOSE: In subjects without underlying cardiac disease dobutamine is known to enhance systolic LV function and LV relaxation. As end-systolic (ES) and end-diastolic (ED) volumes (V) can be derived from gated SPECT we intent to study these volumes and their response to dobutamine in order to have a better understanding of the mechanism by which stroke volume (SV) increases during dobutamine infusion. We intent to do this in normal controls and in young diabetic subjects. METHODS: After injection of sestamibi, serial gated SPECT were obtained at baseline, and during low doses of dobutamine infusion in 12 asymptomatic type I diabetic patients, and in 12 age matched controls. LV EDV, ESV, SV and EF were calculated with the QGS program. RESULTS: Gated SPECT showed comparable LV EF and SV in both groups at rest. There was a significant increase in LVEF and SV during dobutamine infusion but in the diabetic patients the increase in SV was due to a decrease in ESV from 25+/-5 to 20+/-6 ml/m2 (p=0.002) and no change in EDV. In normal controls, the increase in EF was due to an increase in EDV from 69+/-10 to 73+/-12 ml/m2 (p=0.002) with no significant change in ESV. CONCLUSION: These data confirm the presence of subclinical abnormalities of diastolic function in asymptomatic type I diabetic patients and show differences in adaptation to inotropic stimulation in order to preserve the increase in stroke volume and LV ejection fraction.


Asunto(s)
Diabetes Mellitus Tipo 1/diagnóstico por imagen , Dobutamina/administración & dosificación , Imagen de Acumulación Sanguínea de Compuerta/métodos , Volumen Sistólico/efectos de los fármacos , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/tratamiento farmacológico , Adulto , Cardiotónicos/administración & dosificación , Diabetes Mellitus Tipo 1/complicaciones , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Relación Dosis-Respuesta a Droga , Humanos , Masculino , Tomografía Computarizada de Emisión de Fotón Único/métodos , Resultado del Tratamiento , Disfunción Ventricular Izquierda/etiología
17.
Br Heart J ; 72(5): 446-51, 1994 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-7818961

RESUMEN

OBJECTIVE: To elucidate why different types of contrast appear in the left atrium during transoesophageal echocardiographic contrast studies. This should lead to a more uniform definition of true patent foramen ovale. BACKGROUND: The Valsalva manoeuvre and cough are routinely used to enhance right to left shunt for the detection of patent foramen ovale. No information is, however, available on the effect of these manoeuvres on the intrinsic echogenicity of blood in the left atrium. METHODS: 30 consecutive patients referred for transoesophageal echocardiography were studied. Gain settings were relatively high so that no details were lost. The appearance of contrast during normal respiration, cough, and the Valsalva manoeuvre was looked for in the left atrium with and without venous injection of 10 ml of 5% dextrose. Frequency of contrast appearance in the left atrium was expressed as a percentage. Intensity of contrast, when present, was graded 1 (mild), 2 (moderate), or 3 (equal to right atrial contrast during injection). Timing was assessed in cardiac cycles after the end of respiratory manoeuvres. RESULTS: Left atrial contrast appeared as a "snowstorm" flowing from the right pulmonary veins towards the middle of the left atrium. It was present respectively with and without contrast injection in eight and five patients during normal respiration, in 15 and seven during a cough, and in 20 and 14 during the Valsalva manoeuvre. When present, the mean intensity of contrast was 1.0 during normal respiration, 1.4 during a cough, and 1.4 during the Valsalva manoeuvre. The mean delay of contrast appearance was 3-4 cycles after release of the Valsalva manoeuvre and after onset of cough. CONCLUSIONS: Respiratory manoeuvres frequently induce the transient appearance of mild to moderate contrast in the left atrium, most often independently of venous injections. Mild contrast was seen only with high gain settings. This contrast is likely to be related to transient stasis in the pulmonary circulation. In some cases peripheral venous injections of dextrose solution produced, without any respiratory manoeuvre, a similar contrast after the first four cardiac cycles of the right atrium filling, which is likely to represent recirculation of the injected bolus through the pulmonary capillary bed. Therefore respiratory manoeuvres should always be performed before contrast injections to allow better distinction between this background and true patent foramen ovale or pulmonary arteriovenous fistula.


Asunto(s)
Tos/diagnóstico por imagen , Ecocardiografía Transesofágica , Defectos del Tabique Interatrial/diagnóstico por imagen , Maniobra de Valsalva , Adulto , Anciano , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Defectos del Tabique Interatrial/fisiopatología , Humanos , Persona de Mediana Edad
18.
Circ Shock ; 35(4): 199-206, 1991 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-1723355

RESUMEN

Septic shock is characterized by a decreased vascular tone and a depressed myocardial function. An impairment in cellular calcium availability has been incriminated in both phenomenons. The effects of BAY K 8644, a dihydropyridine-derivative agent acting as a slow calcium-channel activator, were studied and compared to those of norepinephrine (NE) on an experimental endotoxin shock model in the dog. Thirty minutes after intravenous administration of E. coli endotoxin (3 mg/kg), fluid therapy with normal saline was initiated to restore and maintain pulmonary artery capillary wedge pressure at baseline level. In the first part of the study (8 dogs), the effects of increasing doses of 1, 2, 4, and 8 mcg/kg/min of BAY K 8644 were evaluated. BAY K 8644 administration resulted in an increase in mean arterial pressure (MAP) (65 +/- 16 to 116 +/- 24 mmHg, P less than 0.001), systemic vascular resistance (SVR) (1,451 +/- 526 to 2,632 +/- 804 dynes.sec.cm-5, P less than 0.01), and left ventricular stroke work (LVSW) (0.08 +/- 0.04 to 0.16 +/- 0.07 g.m/kg, P less than 0.05), without change in mean pulmonary artery pressure, cardiac output, O2 transport, or O2 consumption (VO2). In the second part of the study (10 dogs), BAY K 8644 and NE were administered in a randomized order at increasing doses to achieve an identical increase in MAP. For a 20 mmHg increase in MAP, BAY K 8644 increased more SVR than NE (1,284 +/- 299 to 1,717 +/- 551 vs. 1,415 +/- 312 to 1,470 +/- 603 dynes.sec.cm-5, P less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Ácido 3-piridinacarboxílico, 1,4-dihidro-2,6-dimetil-5-nitro-4-(2-(trifluorometil)fenil)-, Éster Metílico/farmacología , Hemodinámica/efectos de los fármacos , Choque Séptico/tratamiento farmacológico , Animales , Modelos Animales de Enfermedad , Perros , Contracción Miocárdica/efectos de los fármacos , Norepinefrina/farmacología , Consumo de Oxígeno/efectos de los fármacos , Resistencia Vascular/efectos de los fármacos
19.
Neurology ; 61(6): 859-61, 2003 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-14504342

RESUMEN

The authors report the clinical, echocardiographic, and pathologic findings in two patients treated with more than 5 mg of pergolide daily who developed symptomatic severe heart failure due to restrictive valvular disease. They also describe the echocardiographic data of another eight patients taking similar doses of pergolide presenting no clinical signs of heart failure. The findings suggest a possible role of high doses of pergolide in inducing restrictive valvular disease.


Asunto(s)
Antiparkinsonianos/efectos adversos , Enfermedades de las Válvulas Cardíacas/inducido químicamente , Enfermedad de Parkinson/tratamiento farmacológico , Pergolida/efectos adversos , Anciano , Anciano de 80 o más Años , Antiparkinsonianos/administración & dosificación , Antiparkinsonianos/uso terapéutico , Insuficiencia de la Válvula Aórtica/inducido químicamente , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Resultado Fatal , Femenino , Enfermedades de las Válvulas Cardíacas/complicaciones , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/inducido químicamente , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Enfermedad de Parkinson/complicaciones , Pergolida/administración & dosificación , Pergolida/uso terapéutico , Insuficiencia de la Válvula Tricúspide/inducido químicamente , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen
20.
Int J Card Imaging ; 11(1): 55-8, 1995 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-7730682

RESUMEN

The Doppler indexes of tricuspid porcine bioprosthetic valves were evaluated in twelve patients without clinical and two-dimensional echocardiographic evidence of valve dysfunction. Peak and mean pressure gradients across the prostheses were measured using the simplified Bernoulli equation. All the Doppler measurements were compared during inspiration and expiration. During inspiration peak velocity, peak gradient and mean gradient (1.52 +/- 0.28 m/s; 9.7 +/- 3.05 mmHg; 4.07 +/- 1.16 mmHg) were significantly higher than during expiration (1.28 +/- 0.8 m/s; 6.58 +/- 2.7 mmHg; 2.98 +/- 1.13 mmHg; p < 0.01) but pressure half time was not significantly different (122 +/- 62 ms versus 134 +/- 75 ms; p > 0.05). Inspiratory range of peak velocities, peak gradients, mean gradients and pressure half times were respectively 0.8-2.04 m/s; 4.9-16.6 mmHg; 1.2-7.2 mmHg; 42-340 ms while expiratory range of values was 0.8-1.93 m/s; 2.6-15 mmHg; 1.1-5.7 mmHg; 46-345 ms. These data suggest that even very long pressure half times do not indicate valve dysfunction. This study demonstrates that large variation of Doppler parameters are present during respiration and could produce inaccuracy in the assessment of bioprostheses in tricuspid position if they are not taken in consideration.


Asunto(s)
Bioprótesis , Ecocardiografía Doppler , Prótesis Valvulares Cardíacas , Respiración , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/diagnóstico por imagen , Adulto , Anciano , Humanos , Persona de Mediana Edad , Valores de Referencia , Válvula Tricúspide/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA