Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 102(6): 1048-1056, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37933728

RESUMEN

BACKGROUND: Percutaneous treatment for ostial left circumflex artery (LCx) lesions is known to be associated with suboptimal results. AIMS: The present study aims to assess the procedural and long-term clinical outcomes of percutaneous coronary intervention (PCI) for de novo ostial LCx lesions overall and according to the coronary revascularization strategy. METHODS: Consecutive patients undergoing PCI with second generation drug eluting stents or drug coated balloons for de novo ostial LCx lesions in three high-volume Italian centers between 2012 and 2021 were retrospectively evaluated. The primary endpoint was target-vessel revascularization (TVR) at 2 years. Secondary endpoints included major adverse cardiovascular and cerebrovascular events (MACCE), target lesion revascularization, myocardial infarction, stroke, all-cause death, and repeat revascularization. RESULTS: A total of 366 patients were included in the analysis with a median follow-up of 901 (IQR: 450-1728) days. 79.5% of the patients were male, 33.6% were diabetic, 49.7% had a previous PCI, and 23.1% a prior surgical revascularization. Very ostial LCx stenting was performed in 34.1%, crossover from left main to LCx in 17.3%, and a two-stent strategy in 48.6% of cases, respectively. In the overall population, the incidence of TVR at 2 years was 19.0% while MACCE rate was 25.7%. No major differences in clinical outcomes were found according to the stenting strategy. Use of intracoronary imaging was associated with fewer MACCE (HR: 0.47, 95% CI: 0.25-1.13, p = 0.01), while the diameter of the stent implanted in the ostial LCx was associated with less TVR (HR: 0.43, 95% CI: 0.25-0.75, p = 0.002). CONCLUSIONS: Percutaneous revascularization of the ostial LCx is associated with a high rate of TVR, regardless of the stenting strategy. Intracoronary imaging and proper stent sizing may reduce the failure rates.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/etiología , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Angiografía Coronaria/métodos
2.
Catheter Cardiovasc Interv ; 100(5): 903-909, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36040688

RESUMEN

OBJECTIVES: To report the experience of a high-volume center with balloon-expandable (BE) stents implantation to manage vascular complications after transcatheter aortic valve replacement (TAVR). BACKGROUND: Despite increased operator experience and better devices, vascular complications after TAVR are still a major issue and covered stent implantation is often required. METHODS: We retrospectively collected baseline and procedural data about 78 consecutive patients who underwent BE stent implantation to manage a vascular complication after transfemoral TAVR. Primary endpoints were technical success, incidence of new-onset claudication and need for vascular interventions during long-term follow-up. Secondary endpoints included length of hospitalization, in-hospital and 30-day mortality, and major postoperative complications. RESULTS: BE stents implantation to manage vascular complications after TAVR was successfully performed in 96.2% of the cases, with bailout surgery required in two cases. One patient suffered in-hospital death. Predischarge Doppler Ultrasound revealed no cases of in-stent occlusion or fracture. At a median follow-up of 429 days (interquartile range, 89-994 days), no cases of symptomatic leg ischemia were reported and only one patient experienced new-onset claudication. CONCLUSIONS: Our experience showed good periprocedural and long-term results of BE covered stent implantation to manage vascular complication after TAVR. Their great radial outward force may guarantee effective hemostasis without necessarily being associated with stent deformation/fracture resulting in restenosis or further interventions. More research is needed to define the role of BE covered stents in this setting.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Enfermedades Vasculares , Humanos , Estudios de Seguimiento , Estudios Retrospectivos , Mortalidad Hospitalaria , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/cirugía , Resultado del Tratamiento , Stents , Enfermedades Vasculares/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
3.
Cureus ; 16(7): e63936, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39105017

RESUMEN

Left atrial appendage closure (LAAC) can be used to prevent embolic events in patients with atrial fibrillation who cannot tolerate oral anticoagulants. LAAC has not yet been performed in patients with acquired von Willebrand syndrome. A 74-year-old male with von Willebrand disease presents to the emergency department because of palpitations. Atrial fibrillation with congestive heart failure, hypertension, age ≥75, diabetes, stroke, vascular disease, age between 65-74, and female sex (CHA2DS2-VASC) of 4 was diagnosed. Oral anticoagulation was withheld because of a past medical history of major bleeding events despite treatment of the underlying bleeding diathesis. Therefore, LAAC was considered for stroke prevention. However, the procedure was delayed due to abnormal coagulation cascade levels. Because of the ineffectiveness of treatment and persistently low levels of factor VIII and von Willebrand factor (vWF), the von Willebrand disease hypothesis was abandoned, prompting a new diagnosis for the bleeding disorder. Rapid clearance of factor VIII and vWF, the good response to intravenous immunoglobulins, and the presence of monoclonal gammopathy of undetermined significance allowed the diagnosis of acquired von Willebrand syndrome. After administration of immunoglobulins, factor VIII and vWF levels were normalized, and the LAAC was performed. The patient was discharged on low-dose aspirin. At the nine-month follow-up, the patient did not experience bleeding or embolic events. Stroke prevention in patients with atrial fibrillation and increased bleeding risk requires alternatives to oral anticoagulation. LAAC can be safely performed in patients with acquired von Willebrand syndrome and atrial fibrillation.

4.
Insights Imaging ; 15(1): 157, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38900378

RESUMEN

Transfemoral aortic valve implantation (TAVI) has been long considered the standard of therapy for high-risk patients with severe aortic-stenosis and is now effectively employed in place of surgical aortic valve replacement also in intermediate-risk patients. The potential lasting consequences of minor complications, which might have limited impact on elderly patients, could be more noteworthy in the longer term when occurring in younger individuals. That's why a greater focus on early diagnosis, correct management, and prevention of post-procedural complications is key to achieve satisfactory results. ECG-triggered multidetector computed tomography angiography (CTA) is the mainstay imaging modality for pre-procedural planning of TAVI and is also used for post-interventional early detection of both acute and long-term complications. CTA allows detailed morphological analysis of the valve and its movement throughout the entire cardiac cycle. Moreover, stent position, coronary artery branches, and integrity of the aortic root can be precisely evaluated. Imaging reliability implies the correct technical setting of the computed tomography scan, knowledge of valve type, normal post-interventional findings, and awareness of classic and life-threatening complications after a TAVI procedure. This educational review discusses the main post-procedural complications of TAVI with a specific imaging focus, trying to clearly describe the technical aspects of CTA Imaging in post-TAVI and its clinical applications and challenges, with a final focus on future perspectives and emerging technologies. CRITICAL RELEVANCE STATEMENT: This review undertakes an analysis of the role computed tomography angiography (CTA) plays in the assessment of post-TAVI complications. Highlighting the educational issues related to the topic, empowers radiologists to refine their clinical approach, contributing to enhanced patient care. KEY POINTS: Prompt recognition of TAVI complications, ranging from value issues to death, is crucial. Adherence to recommended scanning protocols, and the optimization of tailored protocols, is essential. CTA is central in the diagnosis of TAVI complications and functions as a gatekeeper to treatment.

5.
Comput Biol Med ; 182: 109159, 2024 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-39303394

RESUMEN

PURPOSE: The objective of this study is to validate a novel workflow for implementing patient-specific finite element (FE) simulations to virtually replicate the Transcatheter Aortic Valve Implantation (TAVI) procedure. METHODS: Seven patients undergoing TAVI were enrolled. Patient-specific anatomical models were reconstructed from pre-operative computed tomography (CT) scans and subsequentially discretized, considering the native aortic leaflets and calcifications. Moreover, high-fidelity models of CoreValve Evolut R and Acurate Neo2 valves were built. To determine the most suitable material properties for the two stents, an accurate calibration process was undertaken. This involved conducting crimping simulations and fine-tuning Nitinol parameters to fit experimental force-diameter curves. Subsequently, FE simulations of TAVI procedures were conducted. To validate the reliability of the implemented implantation simulations, qualitative and quantitative comparisons with post-operative clinical data, such as angiographies and CT scans, were performed. RESULTS: For both devices, the simulation curves closely matched the experimental data, indicating successful validation of the valves mechanical behaviour. An accurate qualitative superimposition with both angiographies and CTs was evident, proving the reliability of the simulated implantation. Furthermore, a mean percentage difference of 1,79 ± 0,93 % and 3,67 ± 2,73 % between the simulated and segmented final configurations of the stents was calculated in terms of orifice area and eccentricity, respectively. CONCLUSION: This study shows the successful validation of TAVI simulations in patient-specific anatomies, offering a valuable tool to optimize patients care through personalized pre-operative planning. A systematic approach for the validation is presented, laying the groundwork for enhanced predictive modeling in clinical practice.

6.
Circ Cardiovasc Interv ; 16(12): e013232, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37874646

RESUMEN

BACKGROUND: Drug-coated balloons (DCB) are an emerging tool for modern percutaneous coronary intervention (PCI), but evidence on their use for de novo lesions on large vessels is limited. METHODS: Consecutive patients undergoing DCB-based PCI on the left anterior descending artery in 2 Italian centers from 2018 to 2022 were retrospectively enrolled and compared with patients who received left anterior descending PCI with contemporary drug-eluting stents (DES). In-stent restenosis was excluded. The DCB group included both patients undergoing DCB-only PCI and those receiving hybrid PCI with DCB and DES combined. The primary end point was target lesion failure at 2 years, defined as the composite of target lesion revascularization, cardiac death, and target vessel myocardial infarction. RESULTS: We included 147 consecutive patients undergoing DCB-based treatment on the left anterior descending artery and compared them to 701 patients who received conventional PCI with DES. In the DCB group, 43 patients (29.2%) were treated with DCB only and 104 (70.8%) with a hybrid approach; DCB length was greater than stent length in 55.1% of cases. Total treated length was higher in the DCB group (65 [40-82] versus 56 [46-66] mm; P=0.002), while longer DESs were implanted (38 [24-62] versus 56 [46-66] mm; P<0.001) and a higher rate of large vessels were treated (76.2% versus 83.5%; P=0.036) in the DES cohort. The cumulative 2-year target lesion failure incidence was not significantly different between the 2 groups (DCB, 4.1% versus DES, 9.8%; hazard ratio, 0.51 [95% CI, 0.20-1.27]; P=0.15). After a 1:1 propensity score matching resulting in 139 matched pairs, the DCB-based treatment was associated with a lower risk for target lesion failure at 2 years compared with DES-only PCI (hazard ratio, 0.2 [95% CI, 0.07-0.58]; P=0.003), mainly driven by less target lesion revascularization. CONCLUSIONS: A DCB-based treatment approach for left anterior descending revascularization allows a significantly reduced stent burden, thereby potentially limiting target lesion failure risk at midterm follow-up.


Asunto(s)
Angioplastia Coronaria con Balón , Enfermedad de la Arteria Coronaria , Reestenosis Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Estudios Retrospectivos , Stents Liberadores de Fármacos/efectos adversos , Resultado del Tratamiento , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/métodos , Vasos Coronarios/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/complicaciones , Materiales Biocompatibles Revestidos , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/etiología , Reestenosis Coronaria/terapia
7.
Int J Cardiol ; 379: 16-23, 2023 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-36863420

RESUMEN

BACKGROUND: Sex-specific characteristics in patients with aortic stenosis and small annuli undergoing transcatheter aortic valve implantation (TAVI) might affect clinical outcomes and hemodynamics. METHODS: TAVI-SMALL 2 international retrospective registry included 1378 patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area < 400 mm2) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Women (n = 1233) were compared with men (n = 145). One-to-one propensity score (PS) matching resulted in 99 pairs. Primary endpoint was incidence of all-cause mortality. Incidence of pre-discharge severe prosthesis-patient mismatch (PPM) and its association with all-cause mortality were investigated. Binary logistic and Cox regression were performed to adjust the treatment effect for PS quintiles. RESULTS: Incidence of all-cause mortality at a median follow-up of 377 days did not differ between sex in the overall (10.3 vs. 9.8%, p = 0.842) and PS-matched (8.5 vs. 10.9%, p = 0.586) populations. After PS matching, pre-discharge severe PPM was numerically higher in women vs. men (10.2 vs. 4.3%), even though no evidence of a difference was found (p = 0.275). Within the overall population, women with severe PPM suffered a higher incidence of all-cause mortality when compared to those with less than moderate PPM (log-rank p = 0.024) and less than severe PPM (p = 0.027). CONCLUSIONS: No difference in all-cause mortality at medium-term follow-up was observed between women and men with aortic stenosis and small annuli undergoing TAVI. Incidence of pre-discharge severe PPM was numerically higher in women than men, and it was associated with increased all-cause mortality in women.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Masculino , Humanos , Femenino , Válvula Aórtica/cirugía , Estudios Retrospectivos , Puntaje de Propensión , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo
8.
EuroIntervention ; 19(3): 256-266, 2023 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-36950893

RESUMEN

BACKGROUND: Treatment of aortic stenosis in patients with small annuli is challenging and can result in prosthesis-patient mismatch (PPM). AIMS: We aimed to compare the forward flow haemodynamics and clinical outcomes of contemporary transcatheter valves in patients with small annuli. METHODS: The TAVI-SMALL 2 international retrospective registry included 1,378 patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2) treated with transfemoral self-expanding (SEV; n=1,092) and balloon-expandable valves (BEV; n=286) in 16 high-volume centres between 2011 and 2020. Analyses comparing SEV versus BEV and supra-annular (SAV; n=920) versus intra-annular valves (IAV; n=458) included inverse probability of treatment weighting (IPTW). The primary endpoints were the predischarge mean aortic gradient and incidence of severe PPM. The secondary endpoint was the incidence of more than mild paravalvular leak (PVL). RESULTS: The predischarge mean aortic gradient was lower after SAV versus IAV (7.8±3.9 vs 12.0±5.1; p<0.001) and SEV versus BEV implantation (8.0±4.1 vs 13.6±4.7; p<0.001). Severe PPM was more common with IAV and BEV when compared to SAV and SEV implantation, respectively, (8.8% vs 3.6%; p=0.007 and 8.7% vs 4.6%; p=0.041). At multivariable logistic regression weighted by IPTW, SAV protected from severe PPM regardless of its definition. More than mild PVL occurred more often with SEV versus BEV (11.6% vs 2.6%; p<0.001). CONCLUSIONS: In small aortic annuli, implantation of SAV and SEV was associated with a more favourable forward haemodynamic profile than after IAV and BEV implantation, respectively. More than mild PVL was more common after SEV than BEV implantation.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estudios Retrospectivos , Diseño de Prótesis , Estenosis de la Válvula Aórtica/cirugía , Sistema de Registros , Resultado del Tratamiento
9.
Int J Cardiol ; 389: 131236, 2023 10 15.
Artículo en Inglés | MEDLINE | ID: mdl-37532153

RESUMEN

BACKGROUND: Horizontal aorta (HA), defined by an aortic angulation (AA) ≥48°, is associated with worse outcomes particularly after self-expanding (SE) trans-catheter heart valve (THV) implantation. Although the SE ACURATE Neo THV demonstrated favorable procedural success rates in patients with HA, it remains associated with a non-negligible rate of moderate or greater paravalvular leak (PVL). OBJECTIVES: Aim of the study was to assess the performance of ACURATE Neo2 in the setting of HA. METHODS: We performed a multicenter cohort analysis on patients with severe aortic valve stenosis and HA undergoing transcatheter aortic valve replacement (TAVR) with the Neo or Neo2 THV enrolled in the ITAL-neo registry. The primary endpoint was a composite of early safety and clinical efficacy at 30 days according to the Valve Academic Research Consortium-3 (VARC-3). Secondary endpoints included the occurrence of moderate or severe PVL and 90-day clinical outcomes. RESULTS: Among 900 patients included in the ITAL-neo registry, 407 exhibited HA; of these, 300 received a Neo THV and 107 a Neo2 THV. HA, irrespective of the THV implanted, emerged as an independent risk factor for developing ≥ moderate PVL. Technical and device success at 30-day follow-up was comparable between groups. However, Neo2 was associated with a significantly lower rate of ≥moderate PVL vs. Neo: (5% vs. 15%; p < 0.001), which was confirmed also at 90-day follow-up. Additionally, no correlation was found between ≥moderate PVL and AA in the Neo2 group, while PVL degree increased proportionally to the AA in the Neo cohort. CONCLUSION: In patients with HA, the new generation Acurate Neo2 THV was associated with a comparable device success rate and a significantly lower rate of ≥moderate PVL, when compared with its predecessor.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Diseño de Prótesis , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Sistema de Registros
10.
J Am Heart Assoc ; 12(13): e029735, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37345813

RESUMEN

Background Little is known about the impact of transcatheter mitral valve edge-to-edge repair on changes in left ventricular ejection fraction (LVEF) and the effect of an acute reduction in LVEF on prognosis. We aimed to assess changes in LVEF after transcatheter mitral valve edge-to-edge repair for both primary and secondary mitral regurgitation (PMR and SMR, respectively), identify rates and predictors of LVEF reduction, and estimate its impact on prognosis. Methods and Results In this international multicenter registry, patients with both PMR and SMR undergoing transcatheter mitral valve edge-to-edge repair were included. We assessed rates of acute LVEF reduction (LVEFR), defined as an acute relative decrease of >15% in LVEF, its impact on all-cause mortality, major adverse cardiac event (composite end point of all-cause death, mitral valve surgery, and residual mitral regurgitation grade ≥2), and LVEF at 12 months, as well as predictors for LVEFR. Of 2534 patients included (727 with PMR, and 1807 with SMR), 469 (18.5%) developed LVEFR. Patients with PMR were older (79.0±9.2 versus 71.8±8.9 years; P<0.001) and had higher mean LVEF (54.8±14.0% versus 32.7±10.4%; P<0.001) at baseline. After 6 to 12 months (median, 9.9 months; interquartile range, 7.8-11.9 months), LVEF was significantly lower in patients with PMR (53.0% versus 56.0%; P<0.001) but not in patients with SMR. The 1-year mortality was higher in patients with PMR with LVEFR (16.9% versus 9.7%; P<0.001) but not in those with SMR (P=0.236). LVEF at baseline (odds ratio, 1.03 [95% CI, 1.01-1.05]; P=0.002) was predictive of LVEFR for patients with PMR, but not those with SMR (P=0.092). Conclusions Reduction in LVEF is not uncommon after transcatheter mitral valve edge-to-edge repair and is correlated with worsened prognosis in patients with PMR but not patients with SMR. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT05311163.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Función Ventricular Izquierda , Volumen Sistólico , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos
11.
Cardiovasc Revasc Med ; 40S: 279-281, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35227631

RESUMEN

We report a case of a distal radial access (dRA) pseudoaneurysm complicating a chronic total occlusion (CTO) percutaneous coronary intervention (PCI). After hospital discharge, the patient developed progressive pain and swelling at the access site and ultrasound revealed a distal radial artery pseudoaneurysm. This completely resolved conservatively with manual compression. This case highlights a potential vascular complication of the recently introduced dRA with its conservative management.


Asunto(s)
Aneurisma Falso , Oclusión Coronaria , Intervención Coronaria Percutánea , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/terapia , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Humanos , Intervención Coronaria Percutánea/efectos adversos , Arteria Radial/diagnóstico por imagen , Resultado del Tratamiento
12.
JACC Cardiovasc Interv ; 15(11): 1101-1110, 2022 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-35595675

RESUMEN

BACKGROUND: The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed. OBJECTIVES: The aim of this study was to assess the efficacy and safety of the ACURATE neo2 (Boston Scientific) THV in patients with severe aortic valve stenosis. METHODS: ITAL-neo was an observational, retrospective, multicenter registry enrolling consecutive patients with severe aortic valve stenosis, treated with first- and second-generation ACURATE neo THVs, via transfemoral and trans-subclavian access, in 13 Italian centers. One-to-one propensity score matching was applied to account for baseline characteristics unbalance. The primary endpoint was the occurrence of moderate or greater paravalvular AR on predischarge echocardiographic assessment. Secondary endpoints included postprocedural technical success and 90-day device success and safety. RESULTS: Among 900 patients included in the registry, 220 received the ACURATE neo2 THV, whereas 680 were treated with the first-generation device. A total of 410 patients were compared after 1:1 propensity score matching. The ACURATE neo2 THV was associated with a 3-fold lower frequency of postprocedural moderate or greater paravalvular AR (11.2% vs 3.5%; P < 0.001). No other hemodynamic differences were observed. Postprocedural technical success was similar between the 2 cohorts. Fewer adverse events were observed in patients treated with the ACURATE neo2 at 90 days. CONCLUSIONS: Transfemoral transcatheter aortic valve replacement using the ACURATE neo2 was associated with a significant lower frequency of moderate or greater paravalvular AR compared with the earlier generation ACURATE neo device, with encouraging short-term safety and efficacy.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Hemodinámica , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
13.
G Ital Cardiol (Rome) ; 22(3 Suppl 1): 32S-38S, 2021 03.
Artículo en Italiano | MEDLINE | ID: mdl-33847321

RESUMEN

Acute mitral regurgitation is a life-threatening pathology. Nowadays, percutaneous mitral valve repair with the MitraClip device offers, in selected patients, a safe and effective therapeutic alternative to open surgery. Hereby, we report the case of an 82-year-old woman with lateral ST-elevation myocardial infarction determining severe acute mitral regurgitation, who was treated with an urgent MitraClip procedure. Moreover, we discuss echocardiographic assessment of acute mitral regurgitation and we review available literature and possible management of this complex scenario.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano de 80 o más Años , Femenino , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento
14.
Front Cardiovasc Med ; 8: 670457, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34150868

RESUMEN

Prosthesis-patient mismatch (PPM) is present when the effective area of a prosthetic valve inserted into a patient is inferior to that of a normal human valve; the hemodynamic consequence of a valve too small compared with the size of the patient's body is the generation of higher than expected transprosthetic gradients. Despite evidence of increased risk of short- and long-term mortality and of structural valve degeneration in patients with PPM after surgical aortic valve replacement, its clinical impact in patients subject to transcatheter aortic valve implantation (TAVI) is yet unclear. We aim to review and update on the definition and incidence of PPM after TAVI, and its prognostic implications in the overall population and in higher-risk subgroups, such as small aortic annuli or valve-in-valve procedures. Last, we will focus on the armamentarium available in order to reduce risk of PPM when planning a TAVI procedure.

15.
J Cardiovasc Med (Hagerstown) ; 22(11): 818-827, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34261078

RESUMEN

AIMS: Currently, there are few available data regarding a possible role for subclinical atherosclerosis as a risk factor for mortality in Coronavirus Disease 19 (COVID-19) patients. We used coronary artery calcium (CAC) score derived from chest computed tomography (CT) scan to assess the in-hospital prognostic role of CAC in patients affected by COVID-19 pneumonia. METHODS: Electronic medical records of patients with confirmed diagnosis of COVID-19 were retrospectively reviewed. Patients with known coronary artery disease (CAD) were excluded. A CAC score was calculated for each patient and was used to categorize them into one of four groups: 0, 1-299, 300-999 and at least 1000. The primary endpoint was in-hospital mortality for any cause. RESULTS: The final population consisted of 282 patients. Fifty-seven patients (20%) died over a follow-up time of 40 days. The presence of CAC was detected in 144 patients (51%). Higher CAC score values were observed in nonsurvivors [median: 87, interquartile range (IQR): 0.0-836] compared with survivors (median: 0, IQR: 0.0-136). The mortality rate in patients with a CAC score of at least 1000 was significantly higher than in patients without coronary calcifications (50 vs. 11%) and CAC score 1-299 (50 vs. 23%), P < 0.05. After adjusting for clinical variables, the presence of any CAC categories was not an independent predictor of mortality; however, a trend for increased risk of mortality was observed in patients with CAC of at least 1000. CONCLUSION: The correlation between CAC score and COVID-19 is fascinating and under-explored. However, in multivariable analysis, the CAC score did not show an additional value over more robust clinical variables in predicting in-hospital mortality. Only patients with the highest atherosclerotic burden (CAC ≥1000) could represent a high-risk population, similarly to patients with known CAD.


Asunto(s)
COVID-19 , Enfermedad de la Arteria Coronaria , Vasos Coronarios , Mortalidad Hospitalaria , Calcificación Vascular/diagnóstico por imagen , COVID-19/diagnóstico , COVID-19/mortalidad , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Femenino , Factores de Riesgo de Enfermedad Cardiaca , Hospitalización/estadística & datos numéricos , Humanos , Italia/epidemiología , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , SARS-CoV-2/aislamiento & purificación , Tomografía Computarizada por Rayos X/métodos , Calcificación Vascular/epidemiología
16.
G Ital Cardiol (Rome) ; 22(8): 657-664, 2021 Aug.
Artículo en Italiano | MEDLINE | ID: mdl-34310569

RESUMEN

BACKGROUND: Safety of same-day discharge (SSD) after percutaneous coronary interventions (PCI) has been demonstrated in several studies. However, SDD is rarely adopted in Italy, with a potential waste of resources and decrease of patient satisfaction. METHODS: In 2019 we implemented a strategy of SDD for all elective coronary procedures admitted to our Radial Unit. Patients were excluded from SDD in case of contraindications for radial access, known contrast allergy, known left main disease based on previous angiogram or coronary computed tomography scan, chronic total occlusions considered as target of revascularization. We assessed the feasibility and safety of this approach in consecutive patients treated at Humanitas Research Center. RESULTS: Out of 366 patients who were admitted electively to our Radial Unit, 152 (41.5%) underwent only diagnostic coronary angiography, while 214 underwent PCI. As expected, radial access was used in the vast majority of cases (361; 98.6%). Patients were mostly discharged in the same day (268; 73%), both after diagnostic (96.7%) and interventional (56.5%) procedures. Patients that were hospitalized at least for one night were older, had a higher cardiovascular risk profile and had a more complex coronary anatomy (left main or proximal left anterior descending artery disease, bifurcations, total occlusions). There were no significant differences between patients discharged and those who were admitted overnight with regards to 7- and 30-day hospital readmission. CONCLUSIONS: SSD is safe and feasible in the majority of patients after elective coronary procedures (both diagnostic angiography and PCI), and is not associated with increased hospital readmission at 7 and 30 days. On the basis of the current study, a wider SDD program will be implemented in 2020.


Asunto(s)
Alta del Paciente , Intervención Coronaria Percutánea , Procedimientos Quirúrgicos Electivos , Estudios de Factibilidad , Humanos , Tiempo de Internación , Intervención Coronaria Percutánea/efectos adversos , Resultado del Tratamiento
17.
Cardiovasc Res ; 116(14): 2239-2246, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-32637999

RESUMEN

AIMS: Whether pulmonary artery (PA) dimension and coronary artery calcium (CAC) score, as assessed by chest computed tomography (CT), are associated with myocardial injury in patients with coronavirus disease 2019 (COVID-19) is not known. The aim of this study was to explore the risk factors for myocardial injury and death and to investigate whether myocardial injury has an independent association with all-cause mortality in patients with COVID-19. METHODS AND RESULTS: This is a single-centre cohort study including consecutive patients with laboratory-confirmed COVID-19 undergoing chest CT on admission. Myocardial injury was defined as high-sensitivity troponin I >20 ng/L on admission. A total of 332 patients with a median follow-up of 12 days were included. There were 68 (20.5%) deaths; 123 (37%) patients had myocardial injury. PA diameter was higher in patients with myocardial injury compared with patients without myocardial injury [29.0 (25th-75th percentile, 27-32) mm vs. 27.7 (25-30) mm, P < 0.001). PA diameter was independently associated with an increased risk of myocardial injury [adjusted odds ratio 1.10, 95% confidence interval (CI) 1.02-1.19, P = 0.01] and death [adjusted hazard ratio (HR) 1.09, 95% CI 1.02-1.17, P = 0.01]. Compared with patients without myocardial injury, patients with myocardial injury had a lower prevalence of a CAC score of zero (25% vs. 55%, P < 0.001); however, the CAC score did not emerge as a predictor of myocardial injury by multivariable logistic regression. Myocardial injury was independently associated with an increased risk of death by multivariable Cox regression (adjusted HR 2.25, 95% CI 1.27-3.96, P = 0.005). Older age, lower estimated glomerular filtration rate, and lower PaO2/FiO2 ratio on admission were other independent predictors for both myocardial injury and death. CONCLUSIONS: An increased PA diameter, as assessed by chest CT, is an independent risk factor for myocardial injury and mortality in patients with COVID-19. Myocardial injury is independently associated with an approximately two-fold increased risk of death.


Asunto(s)
COVID-19/diagnóstico por imagen , Cardiopatías/diagnóstico por imagen , Arteria Pulmonar/diagnóstico por imagen , Radiografía Torácica , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , COVID-19/mortalidad , COVID-19/virología , Femenino , Cardiopatías/mortalidad , Cardiopatías/virología , Interacciones Huésped-Patógeno , Humanos , Masculino , Persona de Mediana Edad , Admisión del Paciente , Valor Predictivo de las Pruebas , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , SARS-CoV-2/patogenicidad , Factores de Tiempo
20.
Can J Cardiol ; 35(7): 940.e13-940.e16, 2019 07.
Artículo en Inglés | MEDLINE | ID: mdl-31292096

RESUMEN

The incidental finding of a severe occlusive disease of the aorta (coral reef aorta) during the assessment for transcatheter aortic valve replacement in a 75-year-old woman with severe aortic stenosis complicated the process for the Heart Team and led to the consideration of a different access route to find the safest and most appropriate strategy of intervention. A successful transapical transcatheter aortic valve replacement was eventually performed. Coral reef aorta, although rare, is associated with great morbidity and mortality, and it needs to be recognized when planning for intravascular procedures, both for a safer selection of treatment approach and for the prevention of intraprocedural and postprocedural morbidities.


Asunto(s)
Aorta/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Arteriopatías Oclusivas/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Calcificación Vascular/diagnóstico por imagen , Anciano , Femenino , Humanos , Tomografía Computarizada Multidetector
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA