Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Circ Cardiovasc Imaging ; 6(1): 48-57, 2013 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-23212272

RESUMEN

BACKGROUND: Both transthoracic echocardiography (TTE) and cardiac magnetic resonance (CMR) imaging allow quantification of chronic aortic regurgitation (AR) and mitral regurgitation (MR). We hypothesized that CMR measurement of regurgitant volume (RVol) is more reproducible than TTE. METHODS AND RESULTS: TTE and CMR performed on the same day in 57 prospectively enrolled adults (31 with AR, 26 with MR) were measured by 2 independent physicians. TTE RVol(AR) was calculated as Doppler left ventricular outflow minus inflow stroke volume. RVol(MR) was calculated by both the proximal isovelocity surface area method and Doppler volume flow at 2 sites. CMR RVol(AR) was calculated by phase-contrast velocity mapping at the aortic sinuses and RVol(MR) as total left ventricular minus forward stroke volume. Intraobserver and interobserver variabilities were similar. For AR, the Bland-Altman mean interobserver difference in RVol was -0.7 mL (95% confidence interval [CI], -5 to 4) for CMR and -9 mL (95% CI, -53 to -36) for TTE. The Pearson correlation was higher (P=0.001) between CMR (0.99) than TTE readers (0.89). For MR, the Bland-Altman mean difference in RVol between observers was -4 mL (95% CI, -21 to 13) for CMR compared with 0.7 mL (95% CI, -30 to 32) for the proximal isovelocity surface area and -10 mL (95% CI, -76 to 56) for TTE volume flow at 2 sites. Correlation was similar for CMR (0.94) versus TTE readers (0.90 for the proximal isovelocity surface area). CONCLUSIONS: Compared with TTE, CMR has lower intraobserver and interobserver variabilities for RVol(AR), suggesting CMR may be superior for serial measurements. Although RVol(MR) is similar by TTE and CMR, variability in measured RVol by both approaches suggests that caution is needed in clinical practice.


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico , Ecocardiografía Doppler/métodos , Imagen por Resonancia Cinemagnética/métodos , Insuficiencia de la Válvula Mitral/diagnóstico , Función Ventricular Izquierda/fisiología , Adulto , Anciano , Insuficiencia de la Válvula Aórtica/fisiopatología , Diagnóstico Diferencial , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia de la Válvula Mitral/fisiopatología , Pronóstico , Estudios Prospectivos , Curva ROC , Índice de Severidad de la Enfermedad , Volumen Sistólico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA