Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
J Med Internet Res ; 26: e44948, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38718385

RESUMEN

BACKGROUND: Monitoring of gait patterns by insoles is popular to study behavior and activity in the daily life of people and throughout the rehabilitation process of patients. Live data analyses may improve personalized prevention and treatment regimens, as well as rehabilitation. The M-shaped plantar pressure curve during the stance phase is mainly defined by the loading and unloading slope, 2 maxima, 1 minimum, as well as the force during defined periods. When monitoring gait continuously, walking uphill or downhill could affect this curve in characteristic ways. OBJECTIVE: For walking on a slope, typical changes in the stance phase curve measured by insoles were hypothesized. METHODS: In total, 40 healthy participants of both sexes were fitted with individually calibrated insoles with 16 pressure sensors each and a recording frequency of 100 Hz. Participants walked on a treadmill at 4 km/h for 1 minute in each of the following slopes: -20%, -15%, -10%, -5%, 0%, 5%, 10%, 15%, and 20%. Raw data were exported for analyses. A custom-developed data platform was used for data processing and parameter calculation, including step detection, data transformation, and normalization for time by natural cubic spline interpolation and force (proportion of body weight). To identify the time-axis positions of the desired maxima and minimum among the available extremum candidates in each step, a Gaussian filter was applied (σ=3, kernel size 7). Inconclusive extremum candidates were further processed by screening for time plausibility, maximum or minimum pool filtering, and monotony. Several parameters that describe the curve trajectory were computed for each step. The normal distribution of data was tested by the Kolmogorov-Smirnov and Shapiro-Wilk tests. RESULTS: Data were normally distributed. An analysis of variance with the gait parameters as dependent and slope as independent variables revealed significant changes related to the slope for the following parameters of the stance phase curve: the mean force during loading and unloading, the 2 maxima and the minimum, as well as the loading and unloading slope (all P<.001). A simultaneous increase in the loading slope, the first maximum and the mean loading force combined with a decrease in the mean unloading force, the second maximum, and the unloading slope is characteristic for downhill walking. The opposite represents uphill walking. The minimum had its peak at horizontal walking and values dropped when walking uphill and downhill alike. It is therefore not a suitable parameter to distinguish between uphill and downhill walking. CONCLUSIONS: While patient-related factors, such as anthropometrics, injury, or disease shape the stance phase curve on a longer-term scale, walking on slopes leads to temporary and characteristic short-term changes in the curve trajectory.


Asunto(s)
Pie , Marcha , Presión , Caminata , Humanos , Masculino , Femenino , Estudios Transversales , Caminata/fisiología , Adulto , Pie/fisiología , Marcha/fisiología , Adulto Joven , Fenómenos Biomecánicos
2.
Microsc Microanal ; 26(3): 403-412, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32252851

RESUMEN

With the growing importance of three-dimensional and very large field of view imaging, acquisition time becomes a serious bottleneck. Additionally, dose reduction is of importance when imaging material like biological tissue that is sensitive to electron radiation. Random sparse scanning can be used in the combination with image reconstruction techniques to reduce the acquisition time or electron dose in scanning electron microscopy. In this study, we demonstrate a workflow that includes data acquisition on a scanning electron microscope, followed by a sparse image reconstruction based on compressive sensing or alternatively using neural networks. Neuron structures are automatically segmented from the reconstructed images using deep learning techniques. We show that the average dwell time per pixel can be reduced by a factor of 2-3, thereby providing a real-life confirmation of previous results on simulated data in one of the key segmentation applications in connectomics and thus demonstrating the feasibility and benefit of random sparse scanning techniques for a specific real-world scenario.


Asunto(s)
Conectoma/métodos , Microscopía Electrónica de Rastreo/métodos , Redes Neurales de la Computación , Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional , Neuronas
3.
Biophys J ; 115(3): 503-513, 2018 08 07.
Artículo en Inglés | MEDLINE | ID: mdl-30099989

RESUMEN

The spatial distribution of the human epidermal growth factor 2 (HER2) receptor in the plasma membrane of SKBR3 and HCC1954 breast cancer cells was studied. The receptor was labeled with quantum dot nanoparticles, and fixed whole cells were imaged in their native liquid state with environmental scanning electron microscopy using scanning transmission electron microscopy detection. The locations of individual HER2 positions were determined in a total plasma membrane area of 991 µm2 for several SKBR3 cells and 1062 µm2 for HCC1954 cells. Some of the HER2 receptors were arranged in a linear chain with interlabel distances of 40 ± 7 and 32 ± 10 nm in SKBR3 and HCC1954 cells, respectively. The finding was tested against randomly occurring linear chains of six or more positions, from which it was concluded that the experimental finding is significant and did not arise from random label distributions. Because the measured interlabel distance in the HER2 chains is similar to the 36-nm helix-repetition distance of actin filaments, it is proposed that a linking mechanism between HER2 and actin filaments leads to linearly aligned oligomers.


Asunto(s)
Membrana Celular/química , Microscopía Electrónica de Rastreo , Receptor ErbB-2/química , Línea Celular Tumoral , Humanos
4.
J Xray Sci Technol ; 2017 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-28339423

RESUMEN

BACKGROUND: Laminography is a tomographic technique that allows three-dimensional imaging of flat and elongated objects that stretch beyond the extent of a reconstruction volume. Laminography images can be reconstructed using iterative algorithms based on the Kaczmarz method. OBJECTIVE: This study aims to develop and demonstrate a new reconstruction algorithm that may provide superior image reconstruction quality for this challenged imaging application. METHODS: The images are initially represented using the coefficients over basis functions, which are typically piecewise constant functions (voxels). By replacing voxels with spherically symmetric volume elements (blobs) based on the generalized Kaiser-Bessel window functions, the images are reconstructed using this new adapted version of the algebraic image reconstruction technique. RESULTS: Band-limiting properties of blob functions are beneficial particular in the case of noisy projections and with only a limited number of available projections. Study showed that using blob basis functions improved full-width-at-half-maximum resolution from 10.2±1.0 to 9.9±0.9 (p < 0.001). Signal-to-noise ratio also improved from 16.1 to 31.0. The increased computational demand per iteration was compensated by using a faster convergence rate, such that the overall performance is approximately identical for blobs and voxels. CONCLUSIONS: Despite the higher complexity, tomographic reconstruction from computed laminography data should be implemented using blob basis functions, especially if noisy data is expected.

5.
Microsc Microanal ; 21(6): 1591-1601, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26601573

RESUMEN

We conducted a comparative study of three widely used algorithms for the detection of fiducial markers in electron microscopy images. The algorithms were applied to four datasets from different sources. For the purpose of obtaining comparable results, we introduced figures of merit and implemented all three algorithms in a unified code base to exclude software-specific differences. The application of the algorithms revealed that none of the three algorithms is superior to the others in all cases. This leads to the conclusion that the choice of a marker detection algorithm highly depends on the properties of the dataset to be analyzed, even within the narrowed domain of electron tomography.

6.
Microsc Microanal ; 21(3): 725-38, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26046398

RESUMEN

Combined tilt- and focal series scanning transmission electron microscopy is a recently developed method to obtain nanoscale three-dimensional (3D) information of thin specimens. In this study, we formulate the forward projection in this acquisition scheme as a linear operator and prove that it is a generalization of the Ray transform for parallel illumination. We analytically derive the corresponding backprojection operator as the adjoint of the forward projection. We further demonstrate that the matched backprojection operator drastically improves the convergence rate of iterative 3D reconstruction compared to the case where a backprojection based on heuristic weighting is used. In addition, we show that the 3D reconstruction is of better quality.


Asunto(s)
Imagenología Tridimensional/métodos , Microscopía Electrónica de Transmisión de Rastreo/métodos , Algoritmos , Modelos Teóricos
7.
BMC Musculoskelet Disord ; 15: 434, 2014 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-25511086

RESUMEN

BACKGROUND: Although minimally invasive approaches are widely used in many areas of orthopedic surgery nonunion therapy remains a domain of open surgery. Some attempts have been made to introduce minimally invasive procedures into nonunion therapy. However, these proof of concept studies showed fusion rates comparable to open approaches never gaining wider acceptance in the clinical community. We hypothesize that knowledge of mechanically relevant regions of a nonunion might reduce the complexity of percutaneous procedures, especially in complex fracture patterns, and further reduce the amount of cancellous bone that needs to be transplanted. The aim of this investigation is to provide a proof of concept concerning the hypothesis that mechanically stable fusion of a nonunion can be achieved with less than full circumferential fusion. METHODS: CT data of an artificial tibia with a complex fracture pattern and anatomical LCP are converted into a finite element mesh. The nonunion area is segmented. The finite element mesh is assigned mechanical properties according to data from the literature. An optimization algorithm is developed that reduces the number of voxels in the non union area until the scaled von Mises stress in the implant reaches 20% of the maximum stress in the implant/bone system that occurs with no fusion in the nonunion area at all. RESULTS: After six iterations of the optimization algorithm the number of voxels in the nonunion area is reduced by 96.4%, i.e. only 3.6% of voxels in the non union area are relevant for load transfer such that the von Mises stress in the implant/bone system does not exceed 20% of the maximal scaled von Mises stress occurring in the system with no fusion in the non union area at all. CONCLUSIONS: The hypothesis that less than full circumferential fusion is necessary for mechanical stability of a nonunion is confirmed. As the model provides only qualitative information the observed reduction of fusion area may not be taken literally but needs to be calibrated in future experiments. However this proof of concept provides the mechanical foundation for further development of minimally invasive approaches to delayed union and nonunion therapy.


Asunto(s)
Placas Óseas , Análisis de Elementos Finitos , Fijación Interna de Fracturas/métodos , Estrés Mecánico , Fracturas de la Tibia/cirugía , Placas Óseas/normas , Análisis de Elementos Finitos/normas , Fijación Interna de Fracturas/normas , Humanos , Fracturas de la Tibia/patología , Titanio/administración & dosificación
8.
Microsc Microanal ; 20(2): 548-60, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24548618

RESUMEN

In this study, a combined tilt- and focal series is proposed as a new recording scheme for high-angle annular dark-field scanning transmission electron microscopy (STEM) tomography. Three-dimensional (3D) data were acquired by mechanically tilting the specimen, and recording a through-focal series at each tilt direction. The sample was a whole-mount macrophage cell with embedded gold nanoparticles. The tilt-focal algebraic reconstruction technique (TF-ART) is introduced as a new algorithm to reconstruct tomograms from such combined tilt- and focal series. The feasibility of TF-ART was demonstrated by 3D reconstruction of the experimental 3D data. The results were compared with a conventional STEM tilt series of a similar sample. The combined tilt- and focal series led to smaller "missing wedge" artifacts, and a higher axial resolution than obtained for the STEM tilt series, thus improving on one of the main issues of tilt series-based electron tomography.


Asunto(s)
Tomografía con Microscopio Electrónico/métodos , Microscopía Electrónica de Transmisión de Rastreo/métodos , Algoritmos , Artefactos , Imagenología Tridimensional/métodos , Macrófagos/ultraestructura , Modelos Teóricos , Nanopartículas/ultraestructura
9.
Front Bioeng Biotechnol ; 11: 1110099, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36873371

RESUMEN

The analysis of gait patterns and plantar pressure distributions via insoles is increasingly used to monitor patients and treatment progress, such as recovery after surgeries. Despite the popularity of pedography, also known as baropodography, characteristic effects of anthropometric and other individual parameters on the trajectory of the stance phase curve of the gait cycle have not been previously reported. We hypothesized characteristic changes of age, body height, body weight, body mass index and handgrip strength on the plantar pressure curve trajectory during gait in healthy participants. Thirty-seven healthy women and men with an average age of 43.65 ± 17.59 years were fitted with Moticon OpenGO insoles equipped with 16 pressure sensors each. Data were recorded at a frequency of 100 Hz during walking at 4 km/h on a level treadmill for 1 minute. Data were processed via a custom-made step detection algorithm. The loading and unloading slopes as well as force extrema-based parameters were computed and characteristic correlations with the targeted parameters were identified via multiple linear regression analysis. Age showed a negative correlation with the mean loading slope. Body height correlated with Fmeanload and the loading slope. Body weight and the body mass index correlated with all analyzed parameters, except the loading slope. In addition, handgrip strength correlated with changes in the second half of the stance phase and did not affect the first half, which is likely due to stronger kick-off. However, only up to 46% of the variability can be explained by age, body weight, height, body mass index and hand grip strength. Thus, further factors must affect the trajectory of the gait cycle curve that were not considered in the present analysis. In conclusion, all analyzed measures affect the trajectory of the stance phase curve. When analyzing insole data, it might be useful to correct for the factors that were identified by using the regression coefficients presented in this paper.

10.
PLoS One ; 15(10): e0240813, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33125404

RESUMEN

In this study, we present a novel strategy to the method of finite elements (FEM) of linear elastic problems of very high resolution on graphic processing units (GPU). The approach exploits regularities in the system matrix that occur in regular hexahedral grids to achieve cache-friendly matrix-free FEM. The node-by-node method lies in the class of block-iterative Gauss-Seidel multigrid solvers. Our method significantly improves convergence times in cases where an ordered distribution of distinct materials is present in the dataset. The method was evaluated on three real world datasets: An aluminum-silicon (AlSi) alloy and a dual phase steel material sample, both captured by scanning electron tomography, and a clinical computed tomography (CT) scan of a tibia. The caching scheme leads to a speed-up factor of ×2-×4 compared to the same code without the caching scheme. Additionally, it facilitates the computation of high-resolution problems that cannot be computed otherwise due to memory consumption.


Asunto(s)
Análisis de Elementos Finitos/estadística & datos numéricos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Gráficos por Computador , Sistemas de Computación , Humanos , Programas Informáticos , Tomografía Computarizada por Rayos X/métodos
11.
Ultramicroscopy ; 191: 11-17, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29715521

RESUMEN

In scanning electron microscopy, the achievable image quality is often limited by a maximum feasible acquisition time per dataset. Particularly with regard to three-dimensional or large field-of-view imaging, a compromise must be found between a high amount of shot noise, which leads to a low signal-to-noise ratio, and excessive acquisition times. Assuming a fixed acquisition time per frame, we compared three different strategies for algorithm-assisted image acquisition in scanning electron microscopy. We evaluated (1) raster scanning with a reduced dwell time per pixel followed by a state-of-the-art Denoising algorithm, (2) raster scanning with a decreased resolution in conjunction with a state-of-the-art Super Resolution algorithm, and (3) a sparse scanning approach where a fixed percentage of pixels is visited by the beam in combination with state-of-the-art inpainting algorithms. Additionally, we considered increased beam currents for each of the strategies. The experiments showed that sparse scanning using an appropriate reconstruction technique was superior to the other strategies.

12.
Ultramicroscopy ; 191: 1-10, 2018 08.
Artículo en Inglés | MEDLINE | ID: mdl-29705643

RESUMEN

A new method for dealing with incomplete projection sets in electron tomography is proposed. The approach is inspired by exemplar-based inpainting techniques in image processing and heuristically generates data for missing projection directions. The method has been extended to work on three dimensional data. In general, electron tomography reconstructions suffer from elongation artifacts along the beam direction. These artifacts can be seen in the corresponding Fourier domain as a missing wedge. The new method synthetically generates projections for these missing directions with the help of a dictionary based approach that is able to convey both structure and texture at the same time. It constitutes a preprocessing step that can be combined with any tomographic reconstruction algorithm. The new algorithm was applied to phantom data, to a real electron tomography data set taken from a catalyst, as well as to a real dataset containing solely colloidal gold particles. Visually, the synthetic projections, reconstructions, and corresponding Fourier power spectra showed a decrease of the typical missing wedge artifacts. Quantitatively, the inpainting method is capable to reduce missing wedge artifacts and improves tomogram quality with respect to full width half maximum measurements.

13.
Sci Rep ; 6: 25350, 2016 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-27150131

RESUMEN

A new method for the image acquisition in scanning electron microscopy (SEM) was introduced. The method used adaptively increased pixel-dwell times to improve the signal-to-noise ratio (SNR) in areas of high detail. In areas of low detail, the electron dose was reduced on a per pixel basis, and a-posteriori image processing techniques were applied to remove the resulting noise. The technique was realized by scanning the sample twice. The first, quick scan used small pixel-dwell times to generate a first, noisy image using a low electron dose. This image was analyzed automatically, and a software algorithm generated a sparse pattern of regions of the image that require additional sampling. A second scan generated a sparse image of only these regions, but using a highly increased electron dose. By applying a selective low-pass filter and combining both datasets, a single image was generated. The resulting image exhibited a factor of ≈3 better SNR than an image acquired with uniform sampling on a Cartesian grid and the same total acquisition time. This result implies that the required electron dose (or acquisition time) for the adaptive scanning method is a factor of ten lower than for uniform scanning.

14.
Ultramicroscopy ; 161: 110-118, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26686659

RESUMEN

We present a novel software package for the problem "reconstruction from projections" in electron microscopy. The Ettention framework consists of a set of modular building-blocks for tomographic reconstruction algorithms. The well-known block iterative reconstruction method based on Kaczmarz algorithm is implemented using these building-blocks, including adaptations specific to electron tomography. Ettention simultaneously features (1) a modular, object-oriented software design, (2) optimized access to high-performance computing (HPC) platforms such as graphic processing units (GPU) or many-core architectures like Xeon Phi, and (3) accessibility to microscopy end-users via integration in the IMOD package and eTomo user interface. We also provide developers with a clean and well-structured application programming interface (API) that allows for extending the software easily and thus makes it an ideal platform for algorithmic research while hiding most of the technical details of high-performance computing.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA