1.
J Appl Clin Med Phys ; 19(1): 86-93, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29125239

RESUMEN

Volumetric Modulated Arc Therapy (VMAT) techniques for fractioned stereotactic brain radiotherapy (FSBRT) can achieve highly conformal dose distribution to intracranial lesions. However, they can potentially increase the dose to hippocampus (H) causing neurocognitive toxicity during the first four months after irradiation. The purpose of this study was to assess the feasibility of hippocampal-sparing (HS) treatment plans in 22 patients with brain metastasis treated with VMAT technique. Firstly, we retrospectively analyzed hippocampal doses in all 22 VMAT original (not hippocampal-sparing, NHS) plans. Plans with hippocampal dose exceeding constraints (9 out of 22) were re-planned considering dose constraints on the hippocampus (H) and on hippocampal avoidance zone (HAZ) generated using 5 mm isotropic margin to the hippocampus. Conformity (CI) and homogeneity indexes (HI) on the target and MUs, were maintained as close as possible to the original plans. Mean CINHS and CIHS obtained were: 0.79 ± 0.11 and 0.81 ± 0.10, respectively (P = 0.75); mean HINHS and HIHS were 1.05 ± 0.02 and 1.04 ± 0.01 respectively (P = 0.72). In both sets of plans, the mean MU values were similar: 1033 ± 275 and 1022 ± 234 for NHS and HS respectively. In HS plans, the mean hippocampal dose was decreased by an average of 35%. After replanning, the Dmax (21.3 Gy) for HAZ and H was met by 45% (4/9) and 78% (7/9) of the NHS plans, respectively. The worst results were obtained for cases with target volumes extention closer than 12 mm to H, because of the difficulty to spare hippocampus without compromising target coverage. After replanning D40% constraint value (7.3 Gy) was met by all the 9 NHS plans. In conclusion, this study suggests that an hippocampal-sparing approach to FSBRT is feasible resulting in a decrease in the dose to the hippocampus without any loss in conformity or increase in treatment time.


Asunto(s)
Neoplasias Encefálicas/cirugía , Hipocampo/efectos de la radiación , Tratamientos Conservadores del Órgano/métodos , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/secundario , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
2.
Phys Med ; 94: 94-101, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35007940

RESUMEN

PURPOSE: Radiotherapy may cause malfunction of implantable cardioverter-defibrillators (ICDs) and pacemakers (PMs). We carried-out a multicentre randomized in-vitro study on 65 ICDs and 145 PMs to evaluate malfunctions during and after direct irradiation to doses up to 10 Gy. METHODS: Three centres equipped with different linear accelerator and treatment-planning systems participated in the study. Computed Tomography (CT) acquisitions were performed to build the treatment plans. All devices were exposed to dose of 2, 5, or 10 Gy (6 MV). All devices underwent a baseline examination and 64 wireless real-time telemetry-transmissions (47 ICDs and 17 PMs) were monitored during photon exposures. All devices were interrogated after exposure and once monthly for six subsequent months. RESULTS: Fifty-four of the 64 wireless-enabled CIEDs (84.4%) recorded noise-related interferences during exposure. In detail, 40/47 ICDs (85.1%) reported interference, of which 16 ICDs (34%) reported potentially clinically relevant pacing inhibition and inappropriate detections. Following exposure, a soft reset occurred in 1/145 PM (0.7%) while 7/145 PMs (4.8%) reported battery issues. During the six-month follow-up, 1/145 PM (0.7%) reported a soft reset, while 12/145 more PMs (8.3%) and 1/64 ICD (1.5%) showed abnormal battery depletion. All reported issues occurred independently of exposure dose. Finally, irreversible effects on software and battery life occurred in only non-MRI-compatible devices. CONCLUSION: ICDs mostly featured real-time transient sensing issues, while PMs mostly experienced long-term battery or software issues that were observed immediately following radiation exposure and during follow-up. Irreversible effects on battery life and software occurred in only non-MRI-compatible devices.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Desfibriladores Implantables/efectos adversos , Electrónica , Fotones
3.
Phys Med ; 80: 201-208, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33190076

RESUMEN

This study compares Treatment Planning System (TPS) out of field dose calculation on a pacemaker (PMK) during external beam radiotherapy treatment. We consider four TPSs (Elekta-Monaco, Oncentra- Masterplan and two Philips-Pinnacle3) commissioned for two linacs (Elekta Sinergy and Varian Clinac) delivering two test beams (a highly modulated one and a square field) and two clinical breast plans. To calculate and measure dose to a PMK we built a Real Water3 phantom with a PMK embedded in it. Measures are performed with thermo-luminescent dosimeters and Mosfet dosimeters. We evaluate differences between TPS calculated values for the dose to the PMK (both point dose and dose-volume histogram parameters) when the PMK is positioned in the first 10 cm outside the radiation fields. TPS calculation accuracy is evaluated comparing such values with measures. Differences in TPS calculations are on average 3.5 cGy Gy-1 for the modulated beam, and always lower than 2 cGy Gy-1 for the square beam. TPS dose calculation depends mostly on the TPS algorithm and model rather than the linac commissioned. TPSs considered show different degrees of calculation accuracy. In the first 4 cm to the field edge three out of four TPSs are in good agreement with measurements in the square beam, but only one keeps the agreement in the modulated beam: the others show over and underestimations up to +20% -40%. The same accuracy is found considering a homogeneous phantom. Our results confirm what reported in previous studies and highlight the impact of TPS commissioning.


Asunto(s)
Marcapaso Artificial , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Algoritmos , Humanos , Aceleradores de Partículas , Fantasmas de Imagen , Dosificación Radioterapéutica