Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 24(1): e13780, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36087039

RESUMEN

PURPOSE: To estimate the clinical impact of differences between delivered and planned dose using dose metrics and normal tissue complication probability (NTCP) modeling. METHODS: Forty-six consecutive patients with prostate adenocarcinoma between 2010 and 2015 treated with intensity-modulated radiation therapy (IMRT) and who had undergone computed tomography on rails imaging were included. Delivered doses to bladder and rectum were estimated using a contour-based deformable image registration method. The bladder and rectum NTCP were calculated using dose-response parameters applied to planned and delivered dose distributions. Seven urinary and gastrointestinal symptoms were prospectively collected using the validated prostate cancer symptom indices patient reported outcome (PRO) at pre-treatment, weekly treatment, and post-treatment follow-up visits. Correlations between planned and delivered doses against PRO were evaluated in this study. RESULTS: Planned mean doses to bladder and rectum were 44.9 ± 13.6 Gy and 42.8 ± 7.3 Gy, while delivered doses were 46.1 ± 13.4 Gy and 41.3 ± 8.7 Gy, respectively. D10cc for rectum was 64.1 ± 7.6 Gy for planned and 60.1 ± 9.3 Gy for delivered doses. NTCP values of treatment plan were 22.3% ± 8.4% and 12.6% ± 5.9%, while those for delivered doses were 23.2% ± 8.4% and 9.9% ± 8.3% for bladder and rectum, respectively. Seven of 25 patients with follow-up data showed urinary complications (28%) and three had rectal complications (12%). Correlations of NTCP values of planned and delivered doses with PRO follow-up data were random for bladder and moderate for rectum (0.68 and 0.67, respectively). CONCLUSION: Sensitivity of bladder to clinical variations of dose accumulation indicates that an automated solution based on a DIR that considers inter-fractional organ deformation could recommend intervention. This is intended to achieve additional rectum sparing in cases that indicate higher than expected dose accumulation early during patient treatment in order to prevent acute severity of bowel symptoms.


Asunto(s)
Neoplasias de la Próstata , Radioterapia de Intensidad Modulada , Masculino , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Recto , Vejiga Urinaria , Neoplasias de la Próstata/radioterapia , Neoplasias de la Próstata/patología , Radioterapia de Intensidad Modulada/métodos , Tomografía Computarizada por Rayos X/métodos , Dosificación Radioterapéutica
2.
J Appl Clin Med Phys ; 23(5): e13563, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35194924

RESUMEN

PURPOSE: To determine the possibility of further improving clinical stereotactic body radiotherapy (SBRT) plans using normal tissue complication probability (NTCP) objectives in order to minimize the risk for carotid blowout syndrome (CBOS). METHODS: 10 patients with inoperable locally recurrent head and neck cancer, who underwent SBRT using CyberKnife were analyzed. For each patient, three treatment plans were examined: (1) cone-based without delineation of the ipsilateral internal carotid (clinical plan used to treat the patients); (2) cone-based with the carotid retrospectively delineated and spared; and (3) Iris-based with carotid sparing. The dose-volume histograms of the target and primary organs at risk were calculated. The three sets of plans were compared based on dosimetric and TCP/NTCP (tumor control and normal tissue complication probabilities) metrics. For the NTCP values of carotid, the relative seriality model was used with the following parameters: D50 = 40 Gy, γ = 0.75, and s = 1.0. RESULTS: Across the 10 patient plans, the average TCP did not significantly change when the plans were re-optimized to spare the carotid. The estimated risk of CBOS was significantly decreased in the re-optimized plans, by 14.9% ± 7.4% for the cone-based plans and 17.7% ± 7.1% for the iris-based plans (p = 0.002 for both). The iris-based plans had significant (p = 0.02) reduced CBOS risk and delivery time (20.1% ± 7.4% time reduction, p = 0.002) compared to the cone-based plans. CONCLUSION: A significant improvement in the quality of the clinical plans could be achieved through the delineation of the internal carotids and the use of more modern treatment delivery modalities. In this way, for the same target coverage, a significant reduction in the risk of CBOS could be achieved. The range of risk reduction varied depending on the proximity of carotid artery to the target.


Asunto(s)
Radiocirugia , Radioterapia de Intensidad Modulada , Arterias Carótidas/patología , Arterias Carótidas/cirugía , Humanos , Recurrencia Local de Neoplasia , Probabilidad , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos
3.
J Appl Clin Med Phys ; 21(2): 14-25, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32058663

RESUMEN

PURPOSE: To assess the performance and limitations of contour propagation with three commercial deformable image registration (DIR) algorithms using fractional scans of CT-on-rails (CTOR) and Cone Beam CT (CBCT) in image guided prostate therapy patients treated with IMRT/VMAT. METHODS: Twenty prostate cancer patients treated with IMRT/VMAT were selected for analysis. A total of 453 fractions across those patients were analyzed. Image data were imported into MIM (MIM Software, Inc., Cleveland, OH) and three DIR algorithms (DIR Profile, normalized intensity-based (NIB) and shadowed NIB DIR algorithms) were applied to deformably register each fraction with the planning CT. Manually drawn contours of bladder and rectum were utilized for comparison against the DIR propagated contours in each fraction. Four metrics were utilized in the evaluation of contour similarity, the Hausdorff Distance (HD), Mean Distance to Agreement (MDA), Dice Similarity Coefficient (DSC), and Jaccard indices. A subfactor analysis was performed per modality (CTOR vs. CBCT) and time (fraction). Point estimates and 95% confidence intervals were assessed via a Linear Mixed Effect model for the contour similarity metrics. RESULTS: No statistically significant differences were observed between the DIR Profile and NIB algorithms. However, statistically significant differences were observed between the shadowed NIB and NIB algorithms for some of the DIR evaluation metrics. The Hausdorff Distance calculation showed the NIB propagated contours vs. shadowed NIB propagated contours against the manual contours were 14.82 mm vs. 8.34 mm for bladder and 15.87 mm vs. 11 mm for rectum, respectively. Similarly, the Mean Distance to Agreement calculation comparing the NIB propagated contours vs. shadowed NIB propagated contours against the manual contours were 2.43 mm vs. 0.98 mm for bladder and 2.57 mm vs. 1.00 mm for rectum, respectively. The Dice Similarity Coefficients comparing the NIB propagated contours and shadowed NIB propagated contours against the manual contours were 0.844 against 0.936 for bladder and 0.772 against 0.907 for rectum, respectively. The Jaccard indices comparing the NIB propagated contours and shadowed NIB propagated contours against the manual contours were 0.749 against 0.884 for bladder and 0.637 against 0.831 for rectum, respectively. The shadowed NIB DIR, which showed the closest agreement with the manual contours performed significantly better than the DIR Profile in all the comparisons. The OAR with the greatest agreement varied substantially across patients and image guided radiation therapy (IGRT) modality. Intra-patient variability of contour metric evaluation was insignificant across all the DIR algorithms. Statistical significance at α = 0.05 was observed for manual vs. deformably propagated contours for bladder for all the metrics except Hausdorff Distance (P = 0.01 for MDA, P = 0.02 for DSC, P = 0.01 for Jaccard), whereas the corresponding values for rectum were: P = 0.03 for HD, P = 0.01 for MDA, P < 0.01 for DSC, P < 0.01 for Jaccard. The performance of the different metrics varied slightly across the fractions of each patient, which indicates that weekly contour propagation models provide a reasonable approximation of the daily contour propagation models. CONCLUSION: The high variance of Hausdorff Distance across all automated methods for bladder indicates widely variable agreement across fractions for all patients. Lower variance across all modalities, methods, and metrics were observed for rectum. The shadowed NIB propagated contours were substantially more similar to the manual contours than the DIR Profile or NIB contours for both the CTOR and CBCT imaging modalities. The relationship of each algorithm to similarity with manual contours is consistent across all observed metrics and organs. Screening of image guidance for substantial differences in bladder and rectal filling compared with the planning CT reference could aid in identifying fractions for which automated DIR would prove insufficient.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Radioterapia de Intensidad Modulada/instrumentación , Radioterapia de Intensidad Modulada/métodos , Algoritmos , Tomografía Computarizada de Haz Cónico/instrumentación , Tomografía Computarizada de Haz Cónico/métodos , Análisis Factorial , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Modelos Lineales , Masculino , Reconocimiento de Normas Patrones Automatizadas , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen , Reproducibilidad de los Resultados , Programas Informáticos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos
4.
Breast Cancer Res Treat ; 164(2): 253-262, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28439736

RESUMEN

PURPOSE: Cardiac single-photon emission computed tomography (SPECT) is often used to identify defects in myocardial perfusion due to atherosclerotic coronary artery disease. It was also used in studies to evaluate radiation therapy (RT)-associated cardiac abnormalities. In the current review, we aim to evaluate the rates of post-RT cardiac SPECT early perfusion abnormalities and relate this to the irradiated left ventricular volume. METHODS: The studies cited in this systematic review were identified using the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines. RESULTS: Six studies between 1996 and 2016 fulfilled the inclusion criteria. The reported perfusion defects in these studies were seen in the apical and anterolateral aspects of the left ventricle. Three studies show correlation between the percent of the left ventricle within the RT-field and percent of patients with early perfusion defects on cardiac SPECT. In two studies that used cardiac sparing techniques (such as deep inspiration), that resulted in a low mean heart dose, no perfusion defects were noted. CONCLUSIONS: Data suggest that incidental irradiation of the heart in cases of left breast/chest wall RT can result in early post-RT perfusion defects on cardiac SPECT. There appears to be strong dose/volume dependence to the risk, and hence techniques to reduce cardiac exposure are recommended.


Asunto(s)
Neoplasias de la Mama/radioterapia , Ventrículos Cardíacos/efectos de la radiación , Traumatismos por Radiación/diagnóstico por imagen , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Dosificación Radioterapéutica , Tomografía Computarizada de Emisión de Fotón Único
5.
Opt Lett ; 42(16): 3101-3104, 2017 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-28809883

RESUMEN

Tumor tissue oxygenation significantly affects the outcome of radiotherapy. Real-time monitoring of tumor hypoxia is highly desirable for effective radiotherapy, and is the basis for improved treatment because hypoxic tumor cells are more resistant to radiation damage than fully oxygenated cells. We propose to use Cerenkov imaging to monitor tumor hypoxia by means of tissue blood oxygenation without the need for any exogenous contrast agent. Using a rodent hypoxia model, we demonstrate that Cerenkov imaging can be used as a noninvasive and noncontact method to measure tissue blood oxygenation level during radiation delivery. The data from Cerenkov imaging were validated using near infrared spectrometry methods. The results demonstrate the feasibility of using Cerenkov imaging to monitor tumor hypoxia during therapeutic radiation delivery.


Asunto(s)
Hipoxia/diagnóstico por imagen , Neoplasias/irrigación sanguínea , Oxígeno/análisis , Radiometría/métodos , Medios de Contraste , Humanos , Neoplasias/química , Neoplasias/diagnóstico por imagen
6.
J Appl Clin Med Phys ; 18(5): 245-250, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28857470

RESUMEN

INTRODUCTION: Designing a radiation plan that optimally delivers both target coverage and normal tissue sparing is challenging. There are limited tools to determine what is dosimetrically achievable and frequently the experience of the planner/physician is relied upon to make these determinations. PlanIQ software provides a tool that uses target and organ at risk (OAR) geometry to indicate the difficulty of achieving different points for organ dose-volume histograms (DVH). We hypothesized that PlanIQ Feasibility DVH may aid planners in reducing dose to OARs. METHODS AND MATERIALS: Clinically delivered head and neck treatments (clinical plan) were re-planned (re-plan) putting high emphasis on maximally sparing the contralateral parotid gland, contralateral submandibular gland, and larynx while maintaining routine clinical dosimetric objectives. The planner was blinded to the results of the clinically delivered plan as well as the Feasibility DVHs from PlanIQ. The re-plan treatments were designed using 3-arc VMAT in Raystation (RaySearch Laboratories, Sweden). The planner was then given the results from the PlanIQ Feasibility DVH analysis and developed an additional plan incorporating this information using 4-arc VMAT (IQ plan). The DVHs across the three treatment plans were compared with what was deemed "impossible" by PlanIQ's Feasibility DVH (Impossible DVH). The impossible DVH (red) is defined as the DVH generated using the minimal dose that any voxel outside the targets must receive given 100% target coverage. RESULTS: The re-plans performed blinded to PlanIQ Feasibilty DVH achieved superior sparing of aforementioned OARs compared to the clinically delivered plans and resulted in discrepancies from the impossible DVHs by an average of 200-700 cGy. Using the PlanIQ Feasibility DVH led to additionalOAR sparing compared to both the re-plans and clinical plans and reduced the discrepancies from the impossible DVHs to an average of approximately 100 cGy. The dose reduction from clinical to re-plan and re-plan to IQ plan were significantly different even when taking into account multiple hypothesis testing for both the contralateral parotid and the larynx (P < 0.004 for all comparisons). No significant differences were observed between the three plans for the contralateral parotid when considering multiple hypothesis testing. CONCLUSIONS: Clinical treatment plans and blinded re-plans were found to suboptimally spare OARs. PlanIQ could aid planners in generating treatment plans that push the limits of OAR sparing while maintaining routine clinical target coverage goals.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Órganos en Riesgo/efectos de la radiación , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad Modulada , Estudios de Factibilidad , Humanos , Traumatismos por Radiación/prevención & control , Radiometría , Dosificación Radioterapéutica , Programas Informáticos
7.
Int J Hyperthermia ; 30(3): 176-83, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24669804

RESUMEN

PURPOSE: The aim of this paper is to report thermal dosimetry characteristics of external deep regional pelvic hyperthermia combined with intravesical mitomycin C (MMC) for treating bladder cancer following transurethral resection of bladder tumour, and to use thermal data to evaluate reliability of delivering the prescribed hyperthermia dose to bladder tissue. MATERIALS AND METHODS: A total of 14 patients were treated with MMC and deep regional hyperthermia (BSD-2000, Sigma Ellipse or Sigma 60). The hyperthermia objective was 42° ± 2 °C to bladder tissue for ≥40 min per treatment. Temperatures were monitored with thermistor probes and recorded values were used to calculate thermal dose and evaluate treatment. Anatomical characteristics were examined for possible correlations with heating. RESULTS: Combined with BSD-2000 standard treatment planning and patient feedback, real-time temperature monitoring allowed thermal steering of heat sufficient to attain the prescribed thermal dose to bladder tissue within patient tolerance in 91.6% of treatments. Mean treatment time for bladder tissue >40 °C was 61.9 ± 11.4 min and mean thermal dose was 21.3 ± 16.5 CEM43. Average thermal doses obtained in normal tissues were 1.6 ± 1.2 CEM43 for the rectum and 0.8 ± 1.3 CEM43 in superficial normal tissues. No significant correlation was seen between patient anatomical characteristics and thermal dose achieved in bladder tissue. CONCLUSIONS: This study demonstrates that a hyperthermia prescription of 42° ± 2 °C for 40-60 min can be delivered safely to bladder tissue with external radiofrequency phased array applicators for a typical range of patient sizes. Using the available thermometry and treatment planning, the BSD-2000 hyperthermia system was shown to be an effective method of focusing heat regionally around the bladder with good patient tolerance.


Asunto(s)
Hipertermia Inducida , Neoplasias de la Vejiga Urinaria/terapia , Humanos , Invasividad Neoplásica , Satisfacción del Paciente , Tomografía Computarizada por Rayos X , Neoplasias de la Vejiga Urinaria/diagnóstico por imagen
8.
Artículo en Inglés | MEDLINE | ID: mdl-38452858

RESUMEN

PURPOSE: Radiation-induced lung injury has been shown to alter regional ventilation and perfusion in the lung. However, changes in regional pulmonary gas exchange have not previously been measured. METHODS AND MATERIALS: Ten patients receiving conventional radiation therapy (RT) for lung cancer underwent pre-RT and 3-month post-RT magnetic resonance imaging (MRI) using an established hyperpolarized 129Xe gas exchange technique to map lung function. Four patients underwent an additional 8-month post-RT MRI. The MR signal from inhaled xenon was measured in the following 3 pulmonary compartments: the lung airspaces, the alveolar membrane tissue, and the pulmonary capillaries (interacting with red blood cells [RBCs]). Thoracic 1H MRI scans were acquired, and deformable registration was used to transfer 129Xe functional maps to the RT planning computed tomography scan. The RT-associated changes in ventilation, membrane uptake, and RBC transfer were computed as a function of regional lung dose (equivalent dose in 2-Gy fractions). Pearson correlations and t tests were used to determine statistical significance, and weighted sum of squares linear regression subsequently characterized the dose dependence of each functional component. The pulmonary function testing metrics of forced vital capacity and diffusing capacity for carbon monoxide were also acquired at each time point. RESULTS: Compared with pre-RT baseline, 3-month post-RT ventilation decreased by an average of -0.24 ± 0.05%/Gy (ρ = -0.88; P < .001), membrane uptake increased by 0.69 ± 0.14%/Gy (ρ = 0.94; P < .001), and RBC transfer decreased by -0.41 ± 0.06%/Gy (ρ = -0.92; P < .001). Membrane uptake maintained a strong positive correlation with regional dose at 8 months post-RT, demonstrating an increase of 0.73 ± 0.11%/Gy (ρ = 0.92; P = .006). Changes in membrane uptake and RBC transfer appeared greater in magnitude (%/Gy) for individuals with low heterogeneity in their baseline lung function. An increase in whole-lung membrane uptake showed moderate correlation with decreases in forced vital capacity (ρ = -0.50; P = .17) and diffusing capacity for carbon monoxide (ρ = -0.44; P = .23), with neither correlation reaching statistical significance. CONCLUSIONS: Hyperpolarized 129Xe MRI measured and quantified regional, RT-associated, dose-dependent changes in pulmonary gas exchange. This tool could enable future work to improve our understanding and management of radiation-induced lung injury.

9.
AJR Am J Roentgenol ; 201(5): W698-706, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24147499

RESUMEN

OBJECTIVE: Hypoxia is a characteristic of many tumors and portends a worse prognosis in lung, cervical, prostate, and rectal cancers. Unlike the others, lung cancers present a unique challenge in measuring hypoxia, with invasive biopsies and higher rates of complications. Noninvasive imaging studies detecting hypoxia using isotopes of copper-diacetyl-bis(N4-methylthiosemicarbazone) ((62)Cu-ATSM) have predicted prognosis and treatment outcomes in some small feasibility trials. These images, however, may not identify all areas of hypoxia. Hence, we hypothesize that the addition of another PET imaging agent, copper-pyruvaldehyde-bis(N4-methylthiosemicarbazone) ((62)Cu-PTSM), which can detect areas of perfusion, can augment the information obtained in (62)Cu-ATSM PET scans. SUBJECTS AND METHODS: To characterize tumors on the basis of both perfusion and hypoxia, 10 patients were studied using both (62)Cu-ATSM and (62)Cu-PTSM PET scans. In addition, proteomic arrays looking at specific proangiogenic, survival, and proinflammatory targets were assessed. RESULTS: Six of 10 patients had evaluable PET scans. Our initial experience of characterizing lung tumor hypoxia using (62)Cu-ATSM and (62)Cu-PTSM PET scans showed that visualization of areas with hypoxia normalized for perfusion is feasible. All studied tumors exhibited some hypoxia. Despite the small sample size, a positive relationship was noted between epidermal growth factor levels and (62)Cu-ATSM-detected hypoxia. CONCLUSION: This initial series of (62)Cu-ATSM and (62)Cu-PTSM PET scans shows that evaluating lung masses by visualizing hypoxia and perfusion is a feasible and novel technique to provide more information. Further investigation is warranted to assess the potential role of (62)Cu-ATSM and (62)Cu-PTSM PET techniques combined with proteomics as alternatives to invasive biopsy techniques in clinical care.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Compuestos Organometálicos , Tiosemicarbazonas , Anciano , Complejos de Coordinación , Citocinas/sangre , Femenino , Fluorodesoxiglucosa F18 , Humanos , Hipoxia , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Tasa de Supervivencia
10.
Adv Radiat Oncol ; 8(6): 101234, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37205277

RESUMEN

Purpose: Pretreatment quality assurance (QA) of treatment plans often requires a high cognitive workload and considerable time expenditure. This study explores the use of machine learning to classify pretreatment chart check QA for a given radiation plan as difficult or less difficult, thereby alerting the physicists to increase scrutiny on difficult plans. Methods and Materials: Pretreatment QA data were collected for 973 cases between July 2018 and October 2020. The outcome variable, a degree of difficulty, was collected as a subjective rating by physicists who performed the pretreatment chart checks. Potential features were identified based on clinical relevance, contribution to plan complexity, and QA metrics. Five machine learning models were developed: support vector machine, random forest classifier, adaboost classifier, decision tree classifier, and neural network. These were incorporated into a voting classifier, where at least 2 algorithms needed to predict a case as difficult for it to be classified as such. Sensitivity analyses were conducted to evaluate feature importance. Results: The voting classifier achieved an overall accuracy of 77.4% on the test set, with 76.5% accuracy on difficult cases and 78.4% accuracy on less difficult cases. Sensitivity analysis showed features associated with plan complexity (number of fractions, dose per monitor unit, number of planning structures, and number of image sets) and clinical relevance (patient age) were sensitive across at least 3 algorithms. Conclusions: This approach can be used to equitably allocate plans to physicists rather than randomly allocate them, potentially improving pretreatment chart check effectiveness by reducing errors propagating downstream.

11.
Artículo en Inglés | MEDLINE | ID: mdl-36973099

RESUMEN

PURPOSE: Pulmonary complications, especially idiopathic pneumonitis syndrome (IPS), are potentially life altering or fatal sequelae of hematopoietic cell transplantation (HCT). Total body irradiation (TBI) as part of the conditioning regimen has been implicated in IPS. A comprehensive PENTEC (Pediatric Normal Tissues in the Clinic) review was performed to increase our understanding of the role of TBI in the development of acute, noninfectious IPS. METHODS AND MATERIALS: A systematic literature search was conducted using the MEDLINE, PubMed, and Cochrane library databases for articles describing pulmonary toxicity in children treated with HCT. Data pertaining to TBI and pulmonary endpoints were extracted. Risk of IPS was analyzed in relation to patient age, TBI dose, fractionation, dose rate, lung shielding, timing, and type of transplant, with the goal to better understand factors associated with this complication in children undergoing HCT. A logistic regression model was developed using a subset of studies with comparable transplant regimens and sufficient TBI data. RESULTS: Six studies met criteria for modeling of the correlation of TBI parameters with IPS; all consisted of pediatric patients undergoing allogeneic HCT with a cyclophosphamide-based chemotherapy regimen. IPS was variably defined, but all studies that reported IPS were included in this analysis. The mean incidence of post-HCT IPS was 16% (range, 4%-41%). Mortality from IPS, when it occurred, was high (median, 50%; range, 45%-100%). Fractionated TBI prescription doses encompassed a narrow range of 9 to 14 Gy. Many differing TBI methods were reported, and there was an absence of 3-dimensional dose analysis of lung blocking techniques. Thus, a univariate correlation between IPS and total TBI dose, dose fractionation, dose rate, or TBI technique could not be made. However, a model, built from these studies based on prescribed dose using a normalized dose parameter of equivalent dose in 2-Gy fractions (EQD2), adjusted for dose rate, suggested correlation with the development of IPS (P = .0004). The model-predicted odds ratio for IPS was 24.3 Gy-1 (95% confidence interval, 7.0-84.3). Use of TBI lung dose metrics (eg, midlung point dose) could not be successfully modeled, potentially because of dosimetric uncertainties in the actual delivered volumetric lung dose and imperfections in our modeling process. CONCLUSIONS: This PENTEC report is a comprehensive review of IPS in pediatric patients receiving fractionated TBI regimens for allogenic HCT. IPS was not clearly associated with 1 single TBI factor. Modeling using dose-rate adjusted EQD2 showed a response with IPS for allogeneic HCT using a cyclophosphamide-based chemotherapy regimen. Therefore, this model suggests IPS mitigation strategies can focus on not just the dose and dose per fraction but also the dose rate used in TBI. More data are needed to confirm this model and to determine the influence of chemotherapy regimens and contribution from graft-versus-host disease. The presence of confounding variables (eg, systemic chemotherapies) that affect risk, the narrow range of fractionated TBI doses found in the literature, and limitations of other reported data (eg, lung point dose) may have prevented a more straightforward link between IPS and total dose from being observed.

12.
Med Phys ; 39(3): 1170-81, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22380348

RESUMEN

PURPOSE: A recently completed Phase I clinical trial combined concurrent Mitomycin-C chemotherapy with deep regional heating using BSD-2000 Sigma-Ellipse applicator (BSD Corporation, Salt Lake City, UT, U.S.A.) for the treatment of nonmuscle invasive bladder cancer. This work presents a new treatment planning approach, and demonstrates potential impact of this approach on improvement of treatment quality. METHODS: This study retrospectively analyzes a subset of five patients on the trial. For each treatment, expert operators selected "clinical-optimal" settings based on simple model calculation on the BSD-2000 control console. Computed tomography (CT) scans acquired prior to treatment were segmented to create finite element patient models for retrospective simulations with Sigma-HyperPlan (Dr. Sennewald Medizintechnik GmbH, Munchen, Germany). Since Sigma-HyperPlan does not account for the convective nature of heat transfer within a fluid filled bladder, an effective thermal conductivity for bladder was introduced. This effective thermal conductivity value was determined by comparing simulation results with clinical measurements of bladder and rectum temperatures. Regions of predicted high temperature in normal tissues were compared with patient complaints during treatment. Treatment results using "computed-optimal" settings from the planning system were compared with clinical results using clinical-optimal settings to evaluate potential of treatment improvement by reducing hot spot volume. RESULTS: For all five patients, retrospective treatment planning indicated improved matches between simulated and measured bladder temperatures with increasing effective thermal conductivity. The differences were mostly within 1.3 °C when using an effective thermal conductivity value above 10 W/K/m. Changes in effective bladder thermal conductivity affected surrounding normal tissues within a distance of ∼1.5 cm from the bladder wall. Rectal temperature differences between simulation and measurement were large due to sensitivity to the sampling locations in rectum. The predicted bladder T90 correlated well with single-point bladder temperature measurement. Hot spot locations predicted by the simulation agreed qualitatively with patient complaints during treatment. Furthermore, comparison between the temperature distributions with clinical and computed-optimal settings demonstrated that the computed-optimal settings resulted in substantially reduced hot spot volumes. CONCLUSIONS: Determination of an effective thermal conductivity value for fluid filled bladder was essential for matching simulation and treatment temperatures. Prospectively planning patients using the effective thermal conductivity determined in this work can potentially improve treatment efficacy (compared to manual operator adjustments) by potentially lower discomfort from reduced hot spots in normal tissue.


Asunto(s)
Hipertermia Inducida/métodos , Neoplasias de la Vejiga Urinaria/terapia , Campos Electromagnéticos , Humanos , Estudios Retrospectivos , Temperatura , Neoplasias de la Vejiga Urinaria/tratamiento farmacológico
13.
Med Phys ; 39(12): 7644-9, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23231312

RESUMEN

PURPOSE: Abnormalities in single photon emission computed tomography (SPECT) perfusion within the lung and heart are often detected following radiation for tumors in∕around the thorax (e.g., lung cancer or left-sided breast cancer). The presence of SPECT perfusion defects is determined by comparing pre- and post-RT SPECT images. However, RT may increase the density of the soft tissue surrounding the lung∕heart (e.g., chest wall∕breast) that could possibly lead to an "apparent" SPECT perfusion defect due to increased attenuation of emitted photons. Further, increases in tissue effective depth will also increase SPECT photon attenuation and may lead to "apparent" SPECT perfusion defects. The authors herein quantitatively assess the degree of density changes and effective depth in soft tissues following radiation in a series of patients on a prospective clinical study. METHODS: Patients receiving thoracic RT were enrolled on a prospective clinical study including pre- and post-RT thoracic computed tomography (CT) scans. Using image registration, changes in tissue density and effective depth within the soft tissues were quantified (as absolute change in average CT Hounsfield units, HU, or tissue thickness, cm). Changes in HU and tissue effective depth were considered as a continuous variable. The potential impact of these tissue changes on SPECT images was estimated using simulation data from a female SPECT thorax phantom with varying tissue densities. RESULTS: Pre- and serial post-RT CT images were quantitatively studied in 23 patients (4 breast cancer, 19 lung cancer). Data were generated from soft tissue regions receiving doses of 20-50 Gy. The average increase in density of the chest was 5 HU (range 46 to -69). The average change in breast density was a decrease of -1 HU (range 13 to -13). There was no apparent dose response in neither the dichotomous nor the continuous analysis. Seventy seven soft tissue contours were created for 19 lung cancer patients. The average change in tissue effective depth was +0.2 cm (range -1.9 to 2.2 cm). The changes in HU represent a <2% average change in tissue density. Based on simulation, the small degree of density and tissue effective depth change is unlikely to yield meaningful changes in either SPECT lung or heart perfusion. CONCLUSIONS: RT doses of 20-50 Gy can cause up to a 46 HU increase in soft tissue density 6 months post-RT. Post-RT soft tissue effective depth may increase by 2.0 cm. These modest increases in soft tissue density and effective depth are unlikely to be responsible for the perfusion changes seen on post-RT SPECT lung or heart scans. Further, there was no clear dose response of the soft tissue density changes. Ultimately, the authors findings suggest that prior perfusion reports do reflect changes in the physiology of the lungs and heart.


Asunto(s)
Densitometría/métodos , Corazón/fisiopatología , Corazón/efectos de la radiación , Pulmón/fisiopatología , Pulmón/efectos de la radiación , Modelos Biológicos , Velocidad del Flujo Sanguíneo/efectos de la radiación , Simulación por Computador , Humanos
14.
Stud Health Technol Inform ; 290: 809-813, 2022 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-35673130

RESUMEN

Cognitive Workload (CWL) is a fundamental concept in predicting healthcare professionals' (HCPs) objective performance. The study aims to compare the accuracy of the classical model (utilizes all six dimensions of the National Aeronautics and Space Administration Task Load Index (NASA-TLX)) and novel models (utilize four or five dimensions of NASA-TLX) in predicting HCPs' objective performance. We use a dataset from our previous human factors research studies and apply a broad selection of supervised machine learning classification techniques to develop data-driven computational models and predict objective performance. The study findings confirm that classical models are better predictors of objective performance than novel models. This has practical implications for research in health informatics, human factors and ergonomics, and human-computer interaction in healthcare. Findings, although promising, cannot be generalized as they are based on a small dataset. Future studies may investigate additional subjective and physiological measures of CWL to predict HCPs' objective performance.


Asunto(s)
Análisis y Desempeño de Tareas , Carga de Trabajo , Cognición , Atención a la Salud , Humanos , Aprendizaje Automático , Carga de Trabajo/psicología
15.
Adv Radiat Oncol ; 7(4): 100952, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35814858

RESUMEN

Purpose: To determine the relationship between mean oral cavity (OC) dose (treated as a singular organ at risk) to patient reported xerostomia and dysgeusia. In addition, we will examine the relationship between oral cavity substructure doses to patient reported xerostomia and dysgeusia. All patients were treated in the setting of deintensification (60 Gy). Methods and Materials: In the study, 184 and 177 prospectively enrolled patients for de-escalated chemoradiotherapy (CRT) for human papillomavirus (HPV)-positive oropharyngeal cancer submitted PROs at 6 and 12 months, respectively using Patient-Reported Outcomes version of the Common Terminology Criteria for Adverse Events questionnaire. Patient's OC consisting of the following substructures were segmented: oral tongue, base of tongue, floor of mouth, hard and soft palate, cheek mucosa, and upper and lower lip mucosa. Ordinal logistic regression (no/mild vs moderate vs severe/very severe symptoms) was used to compare organs at risk dosimetry to patient reported xerostomia and dysgeusia at 6 and 12 months. Multivariate ordinal logistic regression models were generated. Results: Mean dose to the contralateral parotid (P = .04), OC (P = .04), and baseline patient reported xerostomia (P = .009) were significantly associated with xerostomia severity at 6 months. Only baseline xerostomia (P = .02) and mean dose to the contralateral submandibular gland (P = .0001) were significantly associated with xerostomia severity at 12 months. The only significant factor related to dysgeusia at either time point was mean dose to the OC at 12 months (P = .009). On examining substructures, the mean dose to the floor of mouth was implicated for the dose relationship to 6-month xerostomia (P = .04), and the oral tongue was found to be implicated for the relationship for 12-month dysgeusia (P = .04). Conclusions: The mean dose to the OC was found to relate to xerostomia symptoms at 6 months post-CRT and dysgeusia symptoms at 12 months post-CRT. The mean dose to the floor of mouth and oral tongue appeared to drive this relationship for xerostomia and dysgeusia symptoms, respectively. This work suggests the floor of mouth and oral tongue should be prioritized during planning over the rest of the OC. The effect of OC dose relative to other salivary structures for xerostomia appeared to depend on time post-CRT.

16.
Pract Radiat Oncol ; 12(3): e193-e200, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34958985

RESUMEN

PURPOSE: This study aimed to prospectively assess dosimetric and clinical effects of treatment planners having a priori knowledge of the maximum achievable dose sparing for organs at risk (OARs) for patients with oropharynx cancer receiving intensity modulated radiation therapy (RT). METHODS AND MATERIALS: We examined patients with oropharynx cancer who were treated in prospective clinical trials between February 2012 and April 2019 at our institution. A tool generating estimates of maximum achievable dose sparing for OARs (feasibility dose-volume histogram [FDVH]) was used clinically starting July 2016. Patients were divided into 2 cohorts: Before (ie, baseline) and after (ie, FDVH-guided) FDVH. Doses received by various OARs were compared with those estimated to be achievable per FDVH, and that difference was defined as the excess of feasible dose (EFD). Patient-reported outcome (PRO) questionnaires were completed at 3, 6, and 12 months after treatment. The baseline and FDVH-guided cohorts were compared in terms of EFD, plan quality metrics, and post-RT PRO assessments. RESULTS: A total of 139 patients were included in the analysis (60 in the baseline cohort, 79 in the FDVH-guided cohort). The FDVH-guided cohort had lower EFD to the contralateral parotid by 4.1 Gy, the ipsilateral parotid by 10.6 Gy, the larynx by 4.3 Gy, the oral cavity by 1.5 Gy, and the contralateral submandibular gland by 0.4 Gy. Plan quality metrics were similar between the cohorts. Less variation of EFD was seen in the FDVH-guided cohort for the parotid glands and contralateral submandibular gland (P < .05). The average post-RT PROs were better in the FVHD cohort versus baseline (particularly at the 6-month timepoint for dry mouth frequency, sticky saliva, meal enjoyment, severity of pain, and Eating Assessment Tool 10 composite [swallowing]; P < .05). CONCLUSIONS: Use of FDVH was associated with improved and less variable OAR sparing for clinically delivered plans. FDVH-guided patients had improved PROs compared with baseline with a variety of outcomes significantly improved at 6 months after treatment.


Asunto(s)
Neoplasias de Cabeza y Cuello , Neoplasias Orofaríngeas , Radioterapia de Intensidad Modulada , Humanos , Órganos en Riesgo/efectos de la radiación , Neoplasias Orofaríngeas/radioterapia , Glándula Parótida/efectos de la radiación , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos
17.
Radiother Oncol ; 172: 42-49, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35537605

RESUMEN

PURPOSE: To assess the impact of prospectively sparing the parotid ducts via MRI sialography on patient reported xerostomia for those receiving definitive radiotherapy (RT) for oropharyngeal squamous cell carcinoma. METHODS AND MATERIALS: Thirty-eight patients with oropharynx cancer to be treated with definitive RT underwent pre-treatment MRI sialograms to localize their parotid ducts. The parotid ducts were maximally spared during treatment planning. Patients reported symptoms (PRO-CTCAE and QLQ-H&N35) were collected at 6 and 12 months post-RT and compared to a historical cohort who underwent conventional parotid gland mean dose sparing. Regression models were generated using parotid and submandibular gland doses with and without incorporating the dose to the parotid ducts to determine the impact of parotid duct dose on patient reported xerostomia. RESULTS: At 6 months post-RT, 12/26 (46%) patients reported ≥moderate xerostomia when undergoing parotid ductal sparing compared to 43/61 (70%) in the historical cohort (p = 0.03). At 12 months post-RT, 8/22 (36%) patients reported ≥moderate xerostomia when undergoing parotid ductal sparing compared to 34/68(50%) in the historical cohort (p = 0.08). Using nested logistic regression models, the mean parotid duct dose was found to significantly relate to patient reported xerostomia severity at 6 months post-RT (p = 0.04) and trended towards statistical significance at 12 months post-RT (p = 0.09). At both 6 and 12 months post-RT, the addition of mean parotid duct dose significantly improved model fit (p < 0.05). CONCLUSIONS: MRI sialography guided parotid duct sparing appears to reduce the rates of patient-reported xerostomia. Further, logistic regression analysis found parotid duct dose to be significantly associated with patient reported xerostomia. A significant improvement in model fit was observed when adding mean parotid duct dose compared to models that only contain mean parotid gland dose and mean contralateral submandibular gland dose.


Asunto(s)
Neoplasias de Cabeza y Cuello , Xerostomía , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Imagen por Resonancia Magnética , Glándula Parótida/diagnóstico por imagen , Medición de Resultados Informados por el Paciente , Estudios Prospectivos , Sialografía , Xerostomía/diagnóstico , Xerostomía/etiología , Xerostomía/prevención & control
18.
Stud Health Technol Inform ; 290: 460-464, 2022 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-35673057

RESUMEN

Chart checking is a time intensive process with high cognitive workload for physicists. Previous studies have partially automated and standardized chart checking, but limited studies implement data-driven approaches to reduce cognitive workload for quality assurance processes. This study aims to evaluate feature selection methods to improve the interpretability and transparency of machine learning models in predicting the degree of difficulty for a pretreatment physics chart check. We compare chi-square, mutual information, feature importance thresholding, and greedy feature selection for four different classifiers. Random forest has the highest performance with SMOTE oversampling using mutual information for feature selection (accuracy 84.0%, AUC 87.0%, precision 80.0%, recall 80.0%). This study demonstrates that feature selection methods can improve model interpretability and transparency.


Asunto(s)
Oncología por Radiación , Ingeniería , Aprendizaje Automático
19.
Med Phys ; 38(5): 2515-22, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21776786

RESUMEN

PURPOSE: To demonstrate the feasibility of using a knowledge base of prior treatment plans to generate new prostate intensity modulated radiation therapy (IMRT) plans. Each new case would be matched against others in the knowledge base. Once the best match is identified, that clinically approved plan is used to generate the new plan. METHODS: A database of 100 prostate IMRT treatment plans was assembled into an information-theoretic system. An algorithm based on mutual information was implemented to identify similar patient cases by matching 2D beam's eye view projections of contours. Ten randomly selected query cases were each matched with the most similar case from the database of prior clinically approved plans. Treatment parameters from the matched case were used to develop new treatment plans. A comparison of the differences in the dose-volume histograms between the new and the original treatment plans were analyzed. RESULTS: On average, the new knowledge-based plan is capable of achieving very comparable planning target volume coverage as the original plan, to within 2% as evaluated for D98, D95, and D1. Similarly, the dose to the rectum and dose to the bladder are also comparable to the original plan. For the rectum, the mean and standard deviation of the dose percentage differences for D20, D30, and D50 are 1.8% +/- 8.5%, -2.5% +/- 13.9%, and -13.9% +/- 23.6%, respectively. For the bladder, the mean and standard deviation of the dose percentage differences for D20, D30, and D50 are -5.9% +/- 10.8%, -12.2% +/- 14.6%, and -24.9% +/- 21.2%, respectively. A negative percentage difference indicates that the new plan has greater dose sparing as compared to the original plan. CONCLUSIONS: The authors demonstrate a knowledge-based approach of using prior clinically approved treatment plans to generate clinically acceptable treatment plans of high quality. This semiautomated approach has the potential to improve the efficiency of the treatment planning process while ensuring that high quality plans are developed.


Asunto(s)
Inteligencia Artificial , Sistemas de Apoyo a Decisiones Clínicas , Bases del Conocimiento , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Conformacional/métodos , Terapia Asistida por Computador/métodos , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
20.
Med Phys ; 38(12): 6754-62, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22149857

RESUMEN

PURPOSE: To commission a small-field biological irradiator, the XRad225Cx from Precision x-Ray, Inc., for research use. The system produces a 225 kVp x-ray beam and is equipped with collimating cones that produce both square and circular radiation fields ranging in size from 1 to 40 mm. This work incorporates point, 2D, and 3D measurements to determine output factors (OF), percent-depth-dose (PDD) and dose profiles at multiple depths. METHODS: Three independent dosimetry systems were used: ion-chambers (a farmer chamber and a micro-ionisation chamber), 2D EBT2 radiochromic film, and a novel 3D dosimetry system (DLOS∕PRESAGE®). Reference point dose rates and output factors were determined from in-air ionization chamber measurements for fields down to ∼13 mm using the formalism of TG61. PDD, profiles, and output factors at three separate depths (0, 0.5, and 2 cm), were determined for all field sizes from EBT2 film measurements in solid water. Several film PDD curves required a scaling correction, reflecting the challenge of accurate film alignment in very small fields. PDDs, profiles, and output factors were also determined with the 3D DLOS∕PRESAGE® system which generated isotropic 0.2 mm data, in scan times of 20 min. RESULTS: Surface output factors determined by ion-chamber were observed to gradually drop by ∼9% when the field size was reduced from 40 to 13 mm. More dramatic drops were observed for the smallest fields as determined by EBT∼18% and ∼42% for the 2.5 mm and 1 mm fields, respectively. PRESAGE® and film output factors agreed well for fields <20 mm (where 3D data were available) with mean deviation of 2.2% (range 1%-4%). PDD values at 2 cm depth varied from ∼72% for the 40 mm field, down to ∼55% for the 1 mm field. EBT and PRESAGE® PDDs agreed within ∼3% in the typical therapy region (1-4 cm). At deeper depths the EBT curves were slightly steeper (2.5% at 5 cm). These results indicate good overall consistency between ion-chamber, EBT2 and PRESAGE® measured OFs, PDDs, and profiles. CONCLUSIONS: The combination of independent 2D and 3D measurements was found to be valuable to ensure accurate and comprehensive commissioning. Film measurements were time consuming and challenging due to the difficulty of film alignment in small fields. PRESAGE® 3D measurements were comprehensive and efficient, because alignment errors are negligible, and all parameters for multiple fields could be obtained from a single dosimeter and scan. However, achieving accurate superficial data (within 4 mm) is not yet feasible due to optical surface artifacts.


Asunto(s)
Radiometría/instrumentación , Radiometría/veterinaria , Radioterapia/instrumentación , Radioterapia/veterinaria , Animales , Diseño de Equipo , Análisis de Falla de Equipo , Ratones , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA