Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
AJNR Am J Neuroradiol ; 24(9): 1881-4, 2003 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-14561620

RESUMEN

SUMMARY: In this study, we compared 8-T gradient-echo MR images of the microvasculature in the live human brain with images of the unembalmed and embalmed postmortem brain. Small vessels were well visualized in the live brain and even better seen in the unembalmed postmortem brain, but they could not be visualized in the embalmed postmortem brain. These findings are important for direct comparisons of the microvasculature on 8-T MR images and on histologic sections.


Asunto(s)
Encéfalo/irrigación sanguínea , Circulación Cerebrovascular , Imagen por Resonancia Magnética , Cambios Post Mortem , Anciano , Anciano de 80 o más Años , Cadáver , Embalsamiento , Humanos , Masculino , Microcirculación , Persona de Mediana Edad
2.
Clin Anat ; 18(3): 164-70, 2005 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-15768413

RESUMEN

The purpose of this study was to quantify the spatial resolution of microscopic arteries on magnetic resonance images acquired at 8 Tesla (T). Techniques similar to those used for standard MRI of the human brain in vivo at 8 T were utilized to generate high-resolution gradient echo (GE) images of a whole postmortem human brain whose common carotid arterial system had been injected with an epoxy-resin. Single slice images, along with summed images of up to 5 contiguous slices, were then compared to color digital photographs detailing the distribution of the arterial system on the surface of the same injected brain. There was excellent MR visualization of the microscopic cerebral arteries down to a spatial resolution of 200 microm. Through the use of an 8 T whole-body MRI scanner and standard GE imaging sequences, microscopic arterial structures can be clearly resolved down to a dimension of 200 microm.


Asunto(s)
Arteriolas/anatomía & histología , Arterias Cerebrales/anatomía & histología , Medios de Contraste/administración & dosificación , Resinas Epoxi/administración & dosificación , Imagen por Resonancia Magnética , Anciano , Anciano de 80 o más Años , Cadáver , Humanos , Inyecciones Intraarteriales , Masculino , Fotograbar , Sensibilidad y Especificidad
3.
Clin Anat ; 18(2): 88-91, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15696533

RESUMEN

The purpose of this study was to evaluate the capacity of high-resolution magnetic resonance imaging (MRI) to visualize the normal anatomic features of the human hippocampus in vitro, using high field imaging equipment, parameters, and acquisition times appropriate for imaging human subjects in vivo. This research compared high field, high-resolution MRI of formalin-fixed normal human hippocampus specimens to histologic sectioning of the same hippocampus samples. Four specimens were evaluated using an 8 Tesla (T), 80 cm bore whole-body MRI scanner equipped with a 12.7 cm single strut transverse electromagnetic resonator (TEM) coil. Hahn spin echo images were acquired with a repetition time (TR) of 800 msec, echo times (TE) of 20, 50, 90, and 134 msec, and an acquisition time (TA) of 3.25 min. The image quality was superb with demonstration of most of the features of the hippocampus. High field, high-resolution MRI can be used to depict multiple layers of the formalin-fixed human hippocampus in vitro using an 8 T whole-body scanner, a TEM coil, and short acquisition times compatible with human imaging in vivo.


Asunto(s)
Imagen Eco-Planar , Hipocampo/anatomía & histología , Aumento de la Imagen , Anciano , Encéfalo , Cadáver , Humanos , Lóbulo Temporal/anatomía & histología
4.
J Magn Reson Imaging ; 19(3): 303-7, 2004 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-14994298

RESUMEN

PURPOSE: To quantify the minimum magnetic resonance imaging (MRI) spatial resolution of the visible deoxygenated microscopic vessels of the human brain at 8 T. MATERIALS AND METHODS: This study compared 8-T gradient echo (GE) images of a human cadaver brain having an in-plane resolution of 195 x 195 microm to corresponding digital photographs of 205 cryomicrotome sections of the same cadaver brain, along with summed images of 25 contiguous cryomicrotome sections. One-millimeter-thick GE images of a 1-cm-thick unfixed whole coronal brain section were acquired using techniques similar to those commonly utilized for 8-T human imaging in vivo. RESULTS: There was excellent MR visualization of the deoxygenated microscopic vessels within the brain down to a resolution of approximately 100 microm. CONCLUSION: By taking advantage of magnetic susceptibility-based blood oxygenation level-dependent (BOLD) contrast, deoxygenated microscopic blood vessels smaller than the pixel dimensions used for imaging can be visualized using a whole-body 8-T MRI system.


Asunto(s)
Encéfalo/irrigación sanguínea , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Oxígeno/sangre , Encéfalo/anatomía & histología , Cadáver , Venas Cerebrales/anatomía & histología , Imagen Eco-Planar/métodos , Hemoglobinas , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Técnicas In Vitro , Magnetismo , Microcirculación/anatomía & histología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA