Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 23(10): e13776, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36109179

RESUMEN

OBJECTIVE: Cesium-131 brachytherapy is an adjunct for brain tumor treatment, offering potential clinical and radiation protection advantages over other isotopes including iodine-125. We present evidence-based radiation safety recommendations from an initial experience with Cs-131 brachytherapy in the resection cavities of recurrent, previously irradiated brain metastases. METHODS: Twenty-two recurrent brain metastases in 18 patients were resected and treated with permanent Cs-131 brachytherapy implantation using commercially procured seed-impregnated collagen tiles (GammaTile, GT Medical Technologies). Exposure to intraoperative staff was monitored with NVLAP-accredited ring dosimeters. For patient release considerations, NCRP guidelines were used to develop an algorithm for modeling lifetime exposure to family and ancillary staff caring for patients based on measured dose rates. RESULTS: A median of 16 Cs-131 seeds were implanted (range 6-46) with median cumulative strength of 58.72U (20.64-150.42). Resulting dose rates were 1.19 mSv/h (0.28-3.3) on contact, 0.08 mSv/h (0.01-0.35) at 30 cm, and 0.01 mSv/h (0.001-0.03) at 100 cm from the patient. Modeled total caregiver exposure was 0.91 mSv (0.16-3.26), and occupational exposure was 0.06 mSv (0.02-0.23) accounting for patient self-shielding via skull and soft tissue attenuation. Real-time dose rate measurements were grouped into brackets to provide close contact precautions for caregivers ranging from 1-3 weeks for adults and longer for pregnant women and children, including cases with multiple implantations. CONCLUSIONS: Radiological protection precautions were developed based on patient-specific emissions and accounted for multiple implantations of Cs-131, to maintain exposure to staff and the public in accordance with relevant regulatory dose constraints.


Asunto(s)
Neoplasias Encefálicas , Protección Radiológica , Embarazo , Adulto , Niño , Humanos , Femenino , Protección Radiológica/métodos , Radioisótopos de Cesio/uso terapéutico , Radioisótopos de Cesio/efectos adversos , Neoplasias Encefálicas/radioterapia , Encéfalo , Colágeno
2.
AJR Am J Roentgenol ; 214(4): 738-746, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-31414882

RESUMEN

OBJECTIVE. Patient-specific organ and effective dose provides essential information for CT protocol optimization. However, such information is not readily available in the scan records. The purpose of this study was to develop a method to obtain accurate examination- and patient-specific organ and effective dose estimates by use of available scan data and patient body size information for a large cohort of patients. MATERIALS AND METHODS. The data were randomly collected for 1200 patients who underwent CT in a 2-year period. Physical characteristics of the patients and CT technique were processed as inputs for the dose estimator. Organ and effective doses were estimated by use of the inputs and computational human phantoms matched to patients on the basis of sex and effective diameter. Size-based ratios were applied to correct for patient-phantom body size differences. RESULTS. Patients received a mean of 59.9 mGy to the lens of the eye per brain scan, 10.1 mGy to the thyroid per chest scan, 17.5 mGy to the liver per abdomen and pelvis scan, and 19.0 mGy to the liver per body scan. A factor of 2 difference in dose estimates was observed between patients of various habitus. CONCLUSION. Examination- and patient-specific organ and effective doses were estimated for 1200 adult oncology patients undergoing CT. The dose conversion factors calculated facilitate rapid organ and effective dose estimation in clinics. Compared with nonspecific dose estimation methods, patient dose estimations with data specific to the patient and examination can differ by a factor of 2.


Asunto(s)
Neoplasias/diagnóstico por imagen , Órganos en Riesgo/efectos de la radiación , Dosis de Radiación , Radiometría/métodos , Tomografía Computarizada por Rayos X , Adulto , Tamaño Corporal , Medios de Contraste , Humanos , Fantasmas de Imagen , Estudios Retrospectivos
3.
BMC Med Imaging ; 20(1): 9, 2020 01 29.
Artículo en Inglés | MEDLINE | ID: mdl-31996149

RESUMEN

BACKGROUND: Organ absorbed doses and effective doses can be used to compare radiation exposure among medical imaging procedures, compare alternative imaging options, and guide dose optimization efforts. Individual dose estimates are important for relatively radiosensitive patient populations such as children and for radiosensitive organs such as the eye lens. Software-based dose calculation methods conveniently calculate organ dose using patient-adjusted and examination-specific inputs. METHODS: Organ absorbed doses and effective doses were calculated for 429 pediatric 18F-FDG PET-CT patients. Patient-adjusted and scan-specific information was extracted from the electronic medical record and scanner dose-monitoring software. The VirtualDose and OLINDA/EXM (version 2.0) programs, respectively, were used to calculate the CT and the radiopharmaceutical organ absorbed doses and effective doses. Patients were grouped according to age at the time of the scan as follows: less than 1 year old, 1 to 5 years old, 6 to 10 years old, 11 to 15 years old, and 16 to 17 years old. RESULTS: The mean (+/- standard deviation, range) total PET plus CT effective dose was 14.5 (1.9, 11.2-22.3) mSv. The mean (+/- standard deviation, range) PET effective dose was 8.1 (1.2, 5.7-16.5) mSv. The mean (+/- standard deviation, range) CT effective dose was 6.4 (1.8, 2.9-14.7) mSv. The five organs with highest PET dose were: Urinary bladder, heart, liver, lungs, and brain. The five organs with highest CT dose were: Thymus, thyroid, kidneys, eye lens, and gonads. CONCLUSIONS: Organ and effective dose for both the CT and PET components can be estimated with actual patient and scan data using commercial software. Doses calculated using software generally agree with those calculated using dose conversion factors, although some organ doses were found to be appreciably different. Software-based dose calculation methods allow patient-adjusted dose factors. The effort to gather the needed patient data is justified by the resulting value of the characterization of patient-adjusted dosimetry.


Asunto(s)
Fluorodesoxiglucosa F18/administración & dosificación , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Radiofármacos/administración & dosificación , Adolescente , Distribución por Edad , Niño , Preescolar , Femenino , Fluorodesoxiglucosa F18/farmacocinética , Humanos , Lactante , Masculino , Dosis de Radiación , Radiofármacos/farmacocinética , Programas Informáticos
4.
BMC Med Imaging ; 17(1): 28, 2017 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-28446130

RESUMEN

BACKGROUND: Computed Tomography (CT) contributes up to 50% of the medical exposure to the United States population. Children are considered to be at higher risk of developing radiation-induced tumors due to the young age of exposure and increased tissue radiosensitivity. Organ dose estimation is essential for pediatric and adult patient cancer risk assessment. The objective of this study is to validate the VirtualDose software in comparison to currently available software and methods for pediatric and adult CT organ dose estimation. METHODS: Five age groups of pediatric patients and adult patients were simulated by three organ dose estimators. Head, chest, abdomen-pelvis, and chest-abdomen-pelvis CT scans were simulated, and doses to organs both inside and outside the scan range were compared. For adults, VirtualDose was compared against ImPACT and CT-Expo. For pediatric patients, VirtualDose was compared to CT-Expo and compared to size-based methods from literature. Pediatric to adult effective dose ratios were also calculated with VirtualDose, and were compared with the ranges of effective dose ratios provided in ImPACT. RESULTS: In-field organs see less than 60% difference in dose between dose estimators. For organs outside scan range or distributed organs, a five times' difference can occur. VirtualDose agrees with the size-based methods within 20% difference for the organs investigated. Between VirtualDose and ImPACT, the pediatric to adult ratios for effective dose are compared, and less than 21% difference is observed for chest scan while more than 40% difference is observed for head-neck scan and abdomen-pelvis scan. For pediatric patients, 2 cm scan range change can lead to a five times dose difference in partially scanned organs. CONCLUSIONS: VirtualDose is validated against CT-Expo and ImPACT with relatively small discrepancies in dose for organs inside scan range, while large discrepancies in dose are observed for organs outside scan range. Patient-specific organ dose estimation is possible using the size-based methods, and VirtualDose agrees with size-based method for the organs investigated. Careful range selection for CT protocols is necessary for organ dose optimization for pediatric and adult patients.


Asunto(s)
Envejecimiento/fisiología , Modelos Biológicos , Exposición a la Radiación/análisis , Tomografía Computarizada por Rayos X/métodos , Vísceras/fisiología , Recuento Corporal Total/métodos , Absorción de Radiación/fisiología , Adolescente , Algoritmos , Niño , Preescolar , Simulación por Computador , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Modelos Estadísticos , Método de Montecarlo , Especificidad de Órganos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
5.
J Appl Clin Med Phys ; 18(3): 207-214, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28422421

RESUMEN

The workload for shielding purposes of modern linear accelerators (linacs) consists of primary and scatter radiation which depends on the dose delivered to isocenter (cGy) and leakage radiation which depends on the monitor units (MUs). In this study, we report on the workload for 10 treatment vaults in terms of dose to isocenter (cGy), monitor units delivered (MUs), number of treatment sessions (Txs), as well as, use factors (U) and modulation factors (CI) for different treatment techniques. The survey was performed for the years between 2006 and 2015 and included 16 treatment machines which represent different generations of Varian linear accelerators (6EX, 600C, 2100C, 2100EX, and TrueBeam) operating at different electron and x-ray energies (6, 9, 12, 16 and 20 MeV electrons and, 6 and 15 MV x-rays). An institutional review board (IRB) approval was acquired to perform this study. Data regarding patient workload, dose to isocenter, number of monitor units delivered, beam energies, gantry angles, and treatment techniques were exported from an ARIA treatment management system (Varian Medical Systems, Palo Alto, Ca.) into Excel spreadsheets and data analysis was performed in Matlab. The average (± std-dev) number of treatment sessions, dose to isocenter, and number of monitor units delivered per week per machine in 2006 was 119 ± 39 Txs, (300 ± 116) × 102 cGys, and (78 ± 28) × 103 MUs respectively. In contrast, the workload in 2015 was 112 ± 40 Txs, (337 ± 124) × 102 cGys, and (111 ± 46) × 103 MUs. 60% of the workload (cGy) was delivered using 6 MV and 30% using 15 MV while the remaining 10% was delivered using electron beams. The modulation factors (MU/cGy) for IMRT and VMAT were 5.0 (± 3.4) and 4.6 (± 1.6) respectively. Use factors using 90° gantry angle intervals were equally distributed (~0.25) but varied considerably among different treatment techniques. The workload, in terms of dose to isocenter (cGy) and subsequently monitor units (MUs), has been steadily increasing over the past decade. This increase can be attributed to increased use of high dose hypo-fractionated regimens (SBRT, SRS) and the increase in use of IMRT and VMAT, which require higher MUs per cGy as compared to more conventional treatment (3DCRT). Meanwhile, the patient workload in terms of treatment sessions per week remained relatively constant. The findings of this report show that variables used for shielding purposes still fall within the recommendation of NCRP Report 151.


Asunto(s)
Instituciones Oncológicas/estadística & datos numéricos , Aceleradores de Partículas , Carga de Trabajo/estadística & datos numéricos , Humanos , Radioterapia Conformacional , Dispersión de Radiación , Encuestas y Cuestionarios , Factores de Tiempo
6.
J Radiol Prot ; 37(2): 527-550, 2017 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-28586315

RESUMEN

In 2012 IRPA established a task group (TG) to identify key issues in the implementation of the revised eye lens dose limit. The TG reported its conclusions in 2013. In January 2015, IRPA asked the TG to review progress with the implementation of the recommendations from the early report and to collate current practitioner experience. This report presents the results of a survey on the view of the IRPA professionals on the new limit to the lens of the eye and on the wider issue of tissue reactions. Recommendations derived from the survey are presented. This report was approved by IRPA Executive Council on 31 January 2017.


Asunto(s)
Cristalino/efectos de la radiación , Exposición Profesional/prevención & control , Dosis de Radiación , Traumatismos por Radiación/prevención & control , Protección Radiológica/normas , Relación Dosis-Respuesta en la Radiación , Humanos , Internacionalidad , Radiometría
7.
BMC Med Imaging ; 16(1): 41, 2016 06 18.
Artículo en Inglés | MEDLINE | ID: mdl-27317478

RESUMEN

BACKGROUND: Whole body fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography (PET/CT) is the standard of care in oncologic diagnosis and staging, and patient radiation dose must be well understood to balance exam benefits with the risk from radiation exposure. Although reference PET/CT patient doses are available, the potential for widely varying total dose prompts evaluation of clinic-specific patient dose. The aims of this study were to use exam-specific information to characterize the radiation dosimetry of PET/CT exams that used two different CT techniques for adult oncology patients and evaluate the practicality of employing an exam-specific approach to dose estimation. METHODS: Whole body PET/CT scans from two sets of consecutive adult patients were retrospectively reviewed. One set received a PET scan with a standard registration CT and the other a PET scan with a diagnostic quality CT. PET dose was calculated by modifying the standard reference phantoms in OLINDA/EXM 1.1 with patient-specific organ mass. CT dose was calculated using patient-specific data in ImPACT. International Commission on Radiological Protection publication 103 tissue weighting coefficients were used for effective dose. RESULTS: One hundred eighty three adult scans were evaluated (95 men, 88 women). The mean patient-specific effective dose from a mean injected 18F-FDG activity of 450 ± 32 MBq was 9.0 ± 1.6 mSv. For all standard PET/CT patients, mean effective mAs was 39 ± 11 mAs, mean CT effective dose was 5.0 ± 1.0 mSv and mean total effective dose was 14 ± 1.3 mSv. For all diagnostic PET/CT patients, mean effective mAs was 120 ± 51 mAs, mean CT effective dose was 15.4 ± 5.0 mSv and mean total effective dose was 24.4 ± 4.3 mSv. The five organs receiving the highest organ equivalent doses in all exams were bladder, heart, brain, liver and lungs. CONCLUSIONS: Patient-specific parameters optimize the patient dosimetry utilized in the medical justification of whole body PET/CT referrals and optimization of PET and CT acquisition parameters. Incorporating patient-specific data into dose estimates is a worthwhile effort for characterizing patient dose, and the specific dosimetric information assists in the justification of risk and optimization of PET/CT.


Asunto(s)
Fluorodesoxiglucosa F18/administración & dosificación , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Imagen de Cuerpo Entero/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosis de Radiación , Radiometría , Estudios Retrospectivos , Adulto Joven
8.
Radiology ; 275(2): 545-52, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25803490

RESUMEN

PURPOSE: To identify opportunities for improving patient-centered communication about diagnostic imaging tests that involve the use of radiation in a cancer care setting. MATERIALS AND METHODS: Institutional review board approval and informed consent were obtained for this HIPAA-compliant study. Patient knowledge, information sources, and communication preferences were assessed in six focus groups during 2012. The groups consisted of patients undergoing treatment for metastatic colorectal carcinoma, women treated within the past 6 months for early-stage breast carcinoma, men undergoing surveillance after testicular cancer treatment, parents of patients treated for stage I-III neuroblastoma, patients in a thoracic oncology survivorship program, and participants in a lung cancer screening program. A multidisciplinary research team performed thematic content analysis of focus group transcripts. High-level findings were summarized during consensus conferences. RESULTS: Although they were aware of the long-term risk of cancer from exposure to ionizing radiation, most participants reported that their health care provider did not initiate discussion about benefits and risks of radiation from imaging tests. Most patients obtained information by means of self-directed internet searches. Participants expressed gratitude for tests ("That CT saved my daughter's life," "I'd rather have the radiation dosage than being opened up"), yet they expressed concern about having to initiate discussions ("If you don't ask, nobody is going to tell you anything") and the desire to be offered information concerning the rationale for ordering specific imaging examinations, intervals for follow-up imaging, and testing alternatives. Participants believed that such information should be available routinely and that conversation with their personal physician or endorsed, readily available reference materials were ideal methods for information exchange. Understanding imaging radiation risks and active participation in decision making about imaging were especially important to cancer survivors. CONCLUSION: A substantial gap exists between patient expectations and current practices for providing information about medical imaging tests that involve the use of radiation.


Asunto(s)
Comunicación , Diagnóstico por Imagen , Conocimientos, Actitudes y Práctica en Salud , Neoplasias/diagnóstico , Prioridad del Paciente , Adulto , Anciano , Diagnóstico por Imagen/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Riesgo
9.
J Vasc Interv Radiol ; 25(11): 1777-84, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25161128

RESUMEN

PURPOSE: To survey the status quo of ancillary staffing in predominantly hospital-based interventional radiology (IR) suites and to assess interventional radiologist attitudes toward current IR procedure room staffing availability and appropriateness. MATERIALS AND METHODS: Invitations to an online survey composed of 26 questions focused on levels of IR suite ancillary staffing as well as operators' opinions of current IR procedure room staffing were sent via email to 2,284 active Society of Interventional Radiology members. RESULTS: There were 777 survey responses. Nurse staffing count per IR room was at least one in 90% (n = 699) during regular hours and 93.6% (n = 730) during off-hours, respectively. A second technologist was frequently used during regular hours and, to a lesser extent, during on-call hours (n = 341 [43.9%] and n = 122 [15.7%]), respectively. Ten and 15% of IR respondents believe staffing support is inadequate for most interventional procedures requiring moderate sedation during normal business hours and off-hours/weekends, respectively, and 69% and 56% of IR respondents believe anesthesia support is inadequate during normal business hours and during off-hours, respectively. CONCLUSIONS: The number of technologists used per IR suite varies across practices and frequently exceeds that of earlier American College of Radiology recommendations, whereas use of IR suite nurse staffing is consistent with approximately one per suite and constant. However, there is dissatisfaction among surveyed interventional radiologists with availability and appropriateness of staffing of the IR procedure room, particularly during on-call hours and weekends, as well as with anesthesia support for emergent cases. No evidence-based guidelines for staffing the IR suite currently exist. This underscores the need for further investigation with the ultimate goal of creating such guidelines.


Asunto(s)
Actitud del Personal de Salud , Recolección de Datos/métodos , Departamentos de Hospitales , Cuerpo Médico de Hospitales/estadística & datos numéricos , Médicos/estadística & datos numéricos , Radiología Intervencionista , Recolección de Datos/estadística & datos numéricos , Humanos , Sociedades Médicas , Estados Unidos , Recursos Humanos
10.
medRxiv ; 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38826310

RESUMEN

Background: Both short and long sleep durations are adversely associated with numerous chronic conditions, including cardiovascular disease (CVD), diabetes, hypertension, and mortality. The American Academy of Sleep Medicine recommends adults in the United States sleep at least 7 hours and less than 9 hours per night to maintain optimal health. It remains unclear how sleep duration trajectories over time are associated with mortality. Methods: This observational cohort study includes 46,928 Black and White adults (mean age: 53 ± 9 years) who enrolled in the Southern Community Cohort Study between 2002-2009 and completed a follow-up survey in 2008-2013. Participants were categorized into nine sleep duration trajectory categories based on the reported average sleep duration between study enrollment and at follow-up. Participant vital status and date and cause of death were ascertained via linkage to the National Death Index through 2022. Cox regression analysis was performed to estimate hazard ratios (HR) and 95% confidence intervals (CI) for the association between sleep duration trajectory and all-cause and cause-specific mortality (CVD, cancer, and neurodegenerative disease) after adjustment for sociodemographic characteristics, health behaviors, and clinical factors. Results: During a median 12.6 years of follow-up, we documented 13,579 deaths, including 4,135 from CVD, 3,067 from cancer, and 544 from neurodegenerative diseases. Compared to the optimal sleep duration trajectory (maintaining 7-9 hours), all sub-optimal trajectories were associated with significant 6 to 33% greater risk of all-cause mortality in fully adjusted models. Compared to the optimal sleep trajectory, three of the sub-optimal trajectories were associated with increased CVD mortality, with HRs ranging from 1.20 to 1.34. The short-long trajectory was associated with the greatest risk of all-cause mortality (HR:1.33; 95%CI: 1.21, 1.46) and the long-short trajectory was associated with the greatest CVD mortality risk (HR:1.34; 95%CI: 1.10, 1.65). The healthy-long trajectory was associated with the greatest risk of cancer mortality (HR: 1.19; 95%CI:1.00, 1.41). None of the sub-optimal trajectories was associated with neurodegenerative disease mortality. Conclusions: Suboptimal sleep duration trajectories were associated with increased risk of all-cause mortality as well as CVD mortality. Findings highlight the importance of maintaining healthy sleep duration throughout midlife to reduce mortality risk.

11.
Z Med Phys ; 34(1): 100-110, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37537100

RESUMEN

BACKGROUND: Radiation is one of the most important stressors related to missions in space beyond Earth's orbit. Epidemiologic studies of exposed workers have reported elevated rates of Parkinson's disease. The importance of cognitive dysfunction related to low-dose rate radiation in humans is not defined. A meta-analysis was conducted of six cohorts in the Million Person Study (MPS) of low-dose health effects to learn whether there is consistent evidence that Parkinson's disease is associated with radiation dose to brain. MATERIALS AND METHODS: The MPS evaluates all causes of death among U.S. radiation workers and veterans, including Parkinson's disease. Systematic and consistent methods are applied to study all categories of workers including medical radiation workers, industrial radiographers, nuclear power plant workers, atomic veterans, and Manhattan Projects workers at the Los Alamos National Laboratory and at Rocky Flats. Consistent methods for all cohorts are used to estimate organ-specific doses and to obtain vital status and cause of death. RESULTS: The meta-analysis include 6 cohorts within the MPS, consisting of 517,608 workers and 17,219,001 person-years of observation. The mean dose to brain ranged from 6.9 to 47.6 mGy and the maximum dose from 0.76 to 2.7 Gy. Five of the 6 cohorts revealed positive associations with Parkinson's disease. The overall summary estimate from the meta-analysis was statistically significant based on 1573 deaths due to Parkinson's disease. The summary excess relative risk at 100 mGy was 0.17 (95% CI: 0.05; 0.29). CONCLUSIONS: Parkinson's disease was positively associated with radiation in the MPS cohorts indicating the need for careful evaluation as to causality in other studies, delineation of possible mechanisms, and assessing possible implications for space travel as well as radiation protection guidance for terrestrial workers.


Asunto(s)
Exposición Profesional , Enfermedad de Parkinson , Protección Radiológica , Veteranos , Humanos , Luna , Exposición Profesional/efectos adversos , Protección Radiológica/métodos
12.
EJNMMI Res ; 14(1): 70, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39083105

RESUMEN

BACKGROUND: Radiolabeled antibody 131I-omburtamab was administered intraventricularly in patients with leptomeningeal disease under an institutionally approved study (#NCT03275402). Radiation safety precautions were tailored for individual patients, enabling outpatient treatment based on in-depth, evidence-based recommendations for such precautions. The imperative advancement of streamlined therapeutic administration procedures, eliminating the necessity for inpatient isolation and resource-intensive measures, holds pivotal significance. This development bears broader implications for analogous therapies within the pediatric patient demographic. METHODS: Intraventricular radioimmunotherapy (RIT) with 925-1850 MBq (25-50 mCi) of 131I-omburtamab was administered via the Ommaya reservoir, in designated rooms within the pediatric ambulatory care center. Dosimeters were provided to staff involved in patient care to evaluate exposure during injection and post-administration. Post-administration exposure rate readings from the patient on contact, at 0.3 m, and at 1 m were taken within the first 30 min, and the room was surveyed after patient discharge. Duration of radiation exposure was calculated using standard U.S. Nuclear Regulatory Commission (US NRC) regulatory guidance recommendations combined with mean exposure rates and whole-body clearance estimates. Exposure rate measurements and clearance data provided patient-specific precautions for four cohorts by age: < 3 y/o, 3-10 y/o, 10-18 y/o, and 18+. RESULTS: Post-administration exposure rates for patients ranged from 0.16 to 0.46 µSv/hr/MBq at 0.3 m and 0.03-0.08 µSv/hr/MBq at 1 m. Radiation exposure precautions ranged from 1 to 10 days after release for the four evaluated cohorts. Based on the highest measured exposure rates and slowest whole-body clearance, the longest precautions were approximately 78% lower than the regulatory guidance recommendations. Radiation exposure to staff associated with 131I-omburtamab per administration was substantially below the annual regulatory threshold for individual exposure monitoring. CONCLUSION: 131I-omburtamab can be administered on an outpatient basis, using appropriate patient-based radiation safety precautions that employ patient-specific exposure rate and biological clearance parameters. This trial is registered with the National Library of Medicine's ClinicalTrials.gov. The registration number is NCT03275402, and it was registered on 7 September 2017. The web link is included here. https://clinicaltrials.gov/study/NCT03275402 .

13.
Res Sq ; 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38464207

RESUMEN

Background: Radiolabeled antibody 131I-omburtamab was administered intraventricularly in patients with leptomeningeal disease under an institutionally approved study (#NCT03275402). Radiation safety precautions were tailored for individual patients, enabling outpatient treatment based on in-depth, evidence-based recommendations for such precautions. The imperative advancement of streamlined therapeutic administration procedures, eliminating the necessity for inpatient isolation and resource-intensive measures, holds pivotal significance. This development bears broader implications for analogous therapies within the pediatric patient demographic. Methods: Intraventricular radioimmunotherapy (RIT) with 925-1850 MBq (25-50 mCi) of 131I-omburtamab was administered via the Ommaya reservoir, in designated rooms within the pediatric ambulatory care center. Dosimeters were provided to staff involved in patient care to evaluate exposure during injection and post-administration. Post-administration exposure rate readings from the patient on contact, at 0.3 m, and at 1 m were taken within the first 30 minutes, and the room was surveyed after patient discharge. Duration of radiation exposure was calculated using standard U.S. Nuclear Regulatory Commission (US NRC) regulatory guidance recommendations combined with mean exposure rates and whole-body clearance estimates. Exposure rate measurements and clearance data provided patient-specific precautions for four cohorts by age: < 3 y/o, 3-10 y/o, 10-18 y/o, and 18+. Results: Post-administration exposure rates for patients ranged from 0.16-0.46 µSv/hr/MBq at 1 ft and 0.03-0.08 µSv/hr/MBq at 1 m. Radiation exposure duration ranged from 1-10 days after release for the four evaluated cohorts. Based on the highest measured exposure rates and slowest whole-body clearance, the longest precautions were approximately 78% lower than the regulatory guidance recommendations. Radiation exposure to staff associated with 131I-omburtamab per administration was substantially below the annual regulatory threshold for individual exposure monitoring. Conclusion: 131I-omburtamab can be administered on an outpatient basis, using appropriate patient-based radiation safety precautions that employ patient-specific exposure rate and biological clearance parameters. This trial is registered with the National Library of Medicine's ClinicalTrials.gov. The registration number is NCT03275402, and it was registered on 7 September 2017. The web link is included here. https://clinicaltrials.gov/study/NCT03275402.

15.
Am J Orthod Dentofacial Orthop ; 143(6): 784-92, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23726328

RESUMEN

INTRODUCTION: With the advent of cone-beam computed tomography (CBCT) scans, there has been a transition toward these scans' replacing traditional radiographs for orthodontic diagnosis and treatment planning. Children represent a significant proportion of orthodontic patients. Similar CBCT exposure settings are predicted to result in higher equivalent doses to the head and neck organs in children than in adults. The purpose of this study was to measure the difference in equivalent organ doses from different scanners under similar settings in children compared with adults. METHODS: Two phantom heads were used, representing a 33-year-old woman and a 5-year-old boy. Optically stimulated dosimeters were placed at 8 key head and neck organs, and equivalent doses to these organs were calculated after scanning. The manufacturers' predefined exposure settings were used. RESULTS: One scanner had a pediatric preset option; the other did not. Scanning the child's phantom head with the adult settings resulted in significantly higher equivalent radiation doses to children compared with adults, ranging from a 117% average ratio of equivalent dose to 341%. Readings at the cervical spine level were decreased significantly, down to 30% of the adult equivalent dose. When the pediatric preset was used for the scans, there was a decrease in the ratio of equivalent dose to the child mandible and thyroid. CONCLUSIONS: CBCT scans with adult settings on both phantom heads resulted in higher radiation doses to the head and neck organs in the child compared with the adult. In practice, this might result in excessive radiation to children scanned with default adult settings. Collimation should be used when possible to reduce the radiation dose to the patient. While CBCT scans offer a valuable tool, use of CBCT scans should be justified on a specific case-by-case basis.


Asunto(s)
Tomografía Computarizada de Haz Cónico/instrumentación , Cabeza/efectos de la radiación , Cuello/efectos de la radiación , Dosis de Radiación , Adulto , Encéfalo/efectos de la radiación , Vértebras Cervicales/efectos de la radiación , Preescolar , Ojo/efectos de la radiación , Femenino , Humanos , Cristalino/efectos de la radiación , Masculino , Mandíbula/efectos de la radiación , Maxilar/efectos de la radiación , Glándula Parótida/efectos de la radiación , Fantasmas de Imagen , Radiometría/instrumentación , Cráneo/efectos de la radiación , Glándula Tiroides/efectos de la radiación
16.
Int J Radiat Biol ; 99(4): 702-711, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35930470

RESUMEN

PURPOSE: This article summarizes a number of presentations from a session on "Radiation and Circulatory Effects" held during the Radiation Research Society Online 67th Annual Meeting, October 3-6 2021. MATERIALS AND METHODS: Different epidemiological cohorts were analyzed with various statistical means common in epidemiology. The cohorts included the one from the U.S. Million Person Study and the Canadian Fluoroscopy Cohort Study. In addition, one of the contributions in our article relies on results from analyses of the Japanese atomic bomb survivors, Russian emergency and recovery workers and cohorts of nuclear workers. The Canadian Fluoroscopy Cohort Study data were analyzed with a larger series of linear and nonlinear dose-response models in addition to the linear no-threshold (LNT) model. RESULTS AND CONCLUSIONS: The talks in this symposium showed that low/moderate acute doses at low/moderate dose rates can be associated with an increased risk of CVD, although some of the epidemiological results for occupational cohorts are equivocal. The usually only limited availability of information on well-known risk factors for circulatory disease (e.g. smoking, obesity, hypertension, diabetes, physical activity) is an important limiting factor that may bias any observed association between radiation exposure and detrimental health outcome, especially at low doses. Additional follow-up and careful dosimetric and outcome assessment are necessary and more epidemiological and experimental research is required. Obtaining reliable information on other risk factors is especially important.


Asunto(s)
Enfermedades Cardiovasculares , Neoplasias Inducidas por Radiación , Exposición Profesional , Humanos , Canadá/epidemiología , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/etiología , Estudios de Cohortes , Neoplasias Inducidas por Radiación/etiología , Exposición Profesional/efectos adversos , Dosis de Radiación
17.
Int J Radiat Biol ; 99(2): 183-207, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-34731066

RESUMEN

BACKGROUND: Estimates of radiation risks following prolonged exposures at low doses and low-dose rates are uncertain. Medical radiation workers are a major component of the Million Person Study (MPS) of low-dose health effects. Annual personal dose equivalents, HP(10), for individual workers are available to facilitate dose-response analyses for lung cancer, leukemia, ischemic heart disease (IHD) and other causes of death. MATERIALS AND METHODS: The Landauer, Inc. dosimetry database identified 109,019 medical and associated radiation workers first monitored 1965-1994. Vital status and cause of death were determined through 2016. Mean absorbed doses to red bone marrow (RBM), lung, heart, and other organs were estimated by adjusting the recorded HP(10) for each worker by scaling factors, accounting for exposure geometry, the energy of the incident photon radiation, sex of the worker and whether an apron was worn. There were 4 exposure scenarios: general radiology characterized by low-energy x-ray exposure with no lead apron use, interventional radiologists/cardiologists who wore aprons, nuclear medicine personnel and radiation oncologists exposed to high-energy photon radiation, and other workers. Standardized mortality ratio (SMR) analyses were performed. Cox proportional hazards models were used to estimate organ-specific radiation risks. RESULTS: Overall, 11,433 deaths occurred (SMR 0.60; 95%CI 0.59,0.61), 126 from leukemia other than chronic lymphocytic leukemia (CLL), 850 from lung cancer, and 1654 from IHD. The mean duration of monitoring was 23.7 y. The excess relative rate (ERR) per 100 mGy was estimated as 0.10 (95% CI -0.34, 0.54) for leukemia other than CLL, 0.15 (0.02, 0.27) for lung cancer, and -0.10 (-0.27, 0.06) for IHD. The ERR for lung cancer was 0.16 (0.01, 0.32) among the 55,218 male workers and 0.09 (-0.19, 0.36) among the 53,801 female workers; a difference that was not statistically significant (p-value = 0.23). CONCLUSIONS: Medical radiation workers were at increased risk for lung cancer that was higher among men than women, although this difference was not statistically significant. In contrast, the study of Japanese atomic bomb survivors exposed briefly to radiation in 1945 found females to be nearly 3 times the radiation risk of lung cancer compared with males on a relative scale. For medical workers, there were no statistically significant radiation associations with leukemia excluding CLL, IHD or other specific causes of death. Combining these data with other cohorts within the MPS, such as nuclear power plant workers and nuclear submariners, will enable more precise estimates of radiation risks at relatively low cumulative doses.


Asunto(s)
Leucemia Linfocítica Crónica de Células B , Leucemia , Neoplasias Pulmonares , Neoplasias Inducidas por Radiación , Exposición Profesional , Protección Radiológica , Masculino , Humanos , Femenino , Estados Unidos/epidemiología , Radiometría , Exposición Profesional/efectos adversos , Exposición Profesional/análisis , Neoplasias Inducidas por Radiación/epidemiología , Neoplasias Inducidas por Radiación/etiología
18.
Int J Radiat Biol ; 99(2): 208-228, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-35758985

RESUMEN

BACKGROUND: There are few occupational studies of women exposed to ionizing radiation. During World War II, the Tennessee Eastman Corporation (TEC) operated an electromagnetic field separation facility of 1152 calutrons to obtain enriched uranium (235U) used for the Hiroshima atomic bomb. Thousands of women were involved in these operations. MATERIALS AND METHODS: A new study was conducted of 13,951 women and 12,699 men employed at TEC between 1943 and 1947 for at least 90 days. Comprehensive dose reconstruction techniques were used to estimate lung doses from the inhalation of uranium dust based on airborne measurements. Vital status through 2018/2019 was obtained from the National Death Index, Social Security Death Index, Tennessee death records and online public record databases. Analyses included standardized mortality ratios (SMRs) and Cox proportional hazards models. RESULTS: Most workers were hourly (77.7%), white (95.6%), born before 1920 (58.3%), worked in dusty environments (57.0%), and had died (94.9%). Vital status was confirmed for 97.4% of the workers. Women were younger than men when first employed: mean ages 25.0 years and 33.0 years, respectively. The estimated mean absorbed dose to the lung was 32.7 mGy (max 1048 mGy) for women and 18.9 mGy (max 501 mGy) for men. The mean dose to thoracic lymph nodes (TLNs) was 127 mGy. Statistically significant SMRs were observed for lung cancer (SMR 1.25; 95% CI 1.19, 1.31; n = 1654), nonmalignant respiratory diseases (NMRDs) (1.23; 95% CI 1.19, 1.28; n = 2585), and cerebrovascular disease (CeVD) (1.13; 95% CI 1.08, 1.18; n = 1945). For lung cancer, the excess relative rate (ERR) at 100 mGy (95% CI) was 0.01 (-0.10, 0.12; n = 652) among women, and -0.15 (-0.38, 0.07; n = 1002) among men based on a preferred model for men with lung doses <300 mGy. NMRD and non-Hodgkin lymphoma were not associated with estimated absorbed dose to the lung or TLN. CONCLUSIONS: There was little evidence that radiation increased the risk of lung cancer, suggesting that inhalation of uranium dust and the associated high-LET alpha particle exposure to lung tissue experienced over a few years is less effective in causing lung cancer than other types of exposures. There was no statistically significant difference in the lung cancer risk estimates between men and women. The elevation of certain causes of death such as CeVD is unexplained and will require additional scrutiny of workplace or lifestyle factors given that radiation is an unlikely contributor since only the lung and lymph nodes received appreciable dose.


Asunto(s)
Neoplasias Pulmonares , Enfermedades Profesionales , Exposición Profesional , Uranio , Masculino , Humanos , Femenino , Adulto , Uranio/efectos adversos , Tennessee , Exposición Profesional/efectos adversos , Enfermedades Profesionales/etiología , Estudios de Cohortes , Neoplasias Pulmonares/etiología , Polvo
19.
Int J Radiat Biol ; 99(9): 1332-1342, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36318723

RESUMEN

This article summarizes a Symposium on 'Radiation risks of the central nervous system' held virtually at the 67th Annual Meeting of the Radiation Research Society, 3-6 October 2021. Repeated low-dose radiation exposure over a certain period could lead to reduced neuronal proliferation, altered neurogenesis, neuroinflammation and various neurological complications, including psychological consequences, necessitating further research in these areas. Four speakers from radiation biology, genetics and epidemiology presented the latest data from their studies seeking insights into this important topic. This symposium highlighted new and important directions for further research on mental health disorders, neurodegenerative conditions and cognitive impairment. Future studies will examine risks of mental and behavioral disorders and neurodegenerative diseases following protracted radiation exposures to better understand risks of occupational exposures as well as provide insights into risks from exposures to galactic cosmic rays.


Asunto(s)
Radiación Cósmica , Exposición Profesional , Exposición a la Radiación , Exposición Profesional/efectos adversos , Sistema Nervioso Central
20.
Radiat Res ; 200(4): 331-339, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37590492

RESUMEN

Over 4 million survivors of breast cancer live in the United States, 35% of whom were treated before 2009. Approximately half of patients with breast cancer receive radiation therapy, which exposes the untreated contralateral breast to radiation and increases the risk of a subsequent contralateral breast cancer (CBC). Radiation oncology has strived to reduce unwanted radiation dose, but it is unknown whether a corresponding decline in actual dose received to the untreated contralateral breast has occurred. The purpose of this study was to evaluate trends in unwanted contralateral breast radiation dose to inform risk assessment of second primary cancer in the contralateral breast for long-term survivors of breast cancer. Individually estimated radiation absorbed doses to the four quadrants and areola central area of the contralateral breast were estimated for 2,132 women treated with radiation therapy for local/regional breast cancers at age <55 years diagnosed between 1985 and 2008. The two inner quadrant doses and two outer quadrant doses were averaged. Trends in dose to each of the three areas of the contralateral breast were evaluated in multivariable models. The population impact of reducing contralateral breast dose on the incidence of radiation-associated CBC was assessed by estimating population attributable risk fraction (PAR) in a multivariable model. The median dose to the inner quadrants of the contralateral breast was 1.70 Gy; to the areola, 1.20 Gy; and to the outer quadrants, 0.72 Gy. Ninety-two percent of patients received ≥1 Gy to the inner quadrants. For each calendar year of diagnosis, dose declined significantly for each location, most rapidly for the inner quadrants (0.04 Gy/year). Declines in dose were similar across subgroups defined by age at diagnosis and body mass index. The PAR for CBC due to radiation exposure >1 Gy for women <40 years of age was 17%. Radiation dose-reduction measures have reduced dose to the contralateral breast during breast radiation therapy. Reducing the dose to the contralateral breast to <1 Gy could prevent an estimated 17% of subsequent radiation-associated CBCs for women treated under 40 years of age. These dose estimates inform CBC surveillance for the growing number of breast cancer survivors who received radiation therapy as young women in recent decades. Continued reductions in dose to the contralateral breast could further reduce the incidence of radiation-associated CBC.


Asunto(s)
Neoplasias de la Mama , Neoplasias Inducidas por Radiación , Neoplasias Primarias Secundarias , Femenino , Humanos , Estados Unidos , Persona de Mediana Edad , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/epidemiología , Neoplasias Inducidas por Radiación/epidemiología , Neoplasias Inducidas por Radiación/etiología , Factores de Riesgo , Neoplasias Primarias Secundarias/etiología , Neoplasias Primarias Secundarias/complicaciones , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA