Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Blood Press ; 31(1): 288-296, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36266938

RESUMEN

PURPOSE: Obesity is a clear risk factor for hypertension. Blood pressure (BP) measurement in obese patients may be biased by cuff size and upper arm shape which may affect the accuracy of measurements. This study aimed to assess the accuracy of the OptiBP smartphone application for three different body mass index (BMI) categories (normal, overweight and obese). MATERIALS AND METHODS: Participants with a wide range of BP and BMI were recruited at Lausanne University Hospital's hypertension clinic in Switzerland. OptiBP estimated BP by recording an optical signal reflecting light from the participants' fingertips into a smartphone camera. Age, sex and BP distribution were collected to fulfil the AAMI/ESH/ISO universal standards. Both auscultatory BP references and OptiBP BP were measured and compared using the simultaneous opposite arms method, as described in the 81060-2:2018 ISO norm. Subgroup analyses were performed for each BMI category. RESULTS: We analyzed 414 recordings from 95 patients: 34 were overweight and 15 were obese. The OptiBP application had a performance acceptance rate of 82%. The mean and standard deviation (SD) differences between the optical BP estimations and the auscultatory reference rates (criterion 1) were respected in all subgroups: SBP mean value was 2.08 (SD 7.58); 1.32 (6.44); -2.29 (5.62) respectively in obese, overweight and normal weight subgroup. For criterion 2, which investigates the precision errors on an individual level, the threshold for systolic BP in the obese group was slightly above the requirement for this criterion. CONCLUSION: This study demonstrated that the OptiBP application is easily applicable to overweight and obese participants. Differences between the reference measure and the OptiBP estimation were within ISO limits (criterion 1). In obese participants, the SD of mean error was outside criterion 2 limits. Whether auscultatory measurement, due to arm morphology or the OptiBP is associated with increasing bias in obese still needs to be studied.


What is the context? • Hypertension and obesity have a major impact on population health and costs. • Obesity is a chronic disease characterized by abnormal or excessive fat accumulation. • Obesity, in combination with other diseases like hypertension, is a major risk factor for cardiovascular and total death. • In Europe, the obesity rate is 21.5% for men and 24.5% for women. • Hypertension, which continues to increase in the population, is a factor that can be modified when well managed. • Blood pressure measurement by the usual method may be complicated in obese patients due to fat accumulation and the shape of the arm and can lead to measurement errors. In addition, the non-invasive blood pressure measurement can be constraining and uncomfortable.What is new? • Smartphone apps are gradually appearing and allow the measurement of blood pressure without a pressure cuff using photoplethysmography. • OptiBP is a smartphone application that provides an estimate of blood pressure that has been evaluated in the general population. • The objective of this study is to assess whether OptiBP is equally effective in obese and overweight patients.What is the impact? • The use of smartphones to estimate BP in overweight and obese patients may be a solution to the known bias associated with cuff measurement. • The acquisition of more and more data with a larger number of patients will allow the continuous improvement of the application's algorithm.


Asunto(s)
Hipertensión , Aplicaciones Móviles , Humanos , Presión Sanguínea/fisiología , Índice de Masa Corporal , Sobrepeso/complicaciones , Determinación de la Presión Sanguínea/métodos , Obesidad/complicaciones
2.
J Clin Monit Comput ; 36(5): 1525-1533, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-34978654

RESUMEN

We compared blood pressure (BP) values obtained with a new optical smartphone application (OptiBP™) with BP values obtained using a non-invasive automatic oscillometric brachial cuff (reference method) during the first 2 h of surveillance in a post-anesthesia care unit in patients after non-cardiac surgery. Three simultaneous BP measurements of both methods were recorded every 30 min over a 2-h period. The agreement between measurements was investigated using Bland-Altman and error grid analyses. We also evaluated the performance of the OptiBP™ using ISO81060-2:2018 standards which requires the mean of the differences ± standard deviation (SD) between both methods to be less than 5 mmHg ± 8 mmHg. Of 120 patients enrolled, 101 patients were included in the statistical analysis. The Bland-Altman analysis demonstrated a mean of the differences ± SD between the test and reference methods of + 1 mmHg ± 7 mmHg for mean arterial pressure (MAP), + 2 mmHg ± 11 mmHg for systolic arterial pressure (SAP), and + 1 mmHg ± 8 mmHg for diastolic arterial pressure (DAP). Error grid analysis showed that the proportions of measurement pairs in risk zones A to E were 90.3% (no risk), 9.7% (low risk), 0% (moderate risk), 0% (significant risk), 0% (dangerous risk) for MAP and 89.9%, 9.1%, 1%, 0%, 0% for SAP. We observed a good agreement between BP values obtained by the OptiBP™ system and BP values obtained with the reference method. The OptiBP™ system fulfilled the AAMI validation requirements for MAP and DAP and error grid analysis indicated that the vast majority of measurement pairs (≥ 99%) were in risk zones A and B.Trial Registration ClinicalTrials.gov Identifier: NCT04262323.


Asunto(s)
Anestesia , Teléfono Inteligente , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Monitores de Presión Sanguínea , Humanos , Oscilometría
3.
Blood Press Monit ; 26(6): 441-448, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-34139747

RESUMEN

OBJECTIVE: The aim of this study was to assess the accuracy of the OptiBP mobile application based on an optical signal recorded by placing the patient's fingertip on a smartphone's camera to estimate blood pressure (BP). Measurements were carried out in a general population according to existing standards of the Association for the Advancement of Medical Instrumentation (AAMI), the European Society of Hypertension (ESH) and the International Organization for Standardization (ISO). METHODS: Participants were recruited during a scheduled appointment at the hypertension clinic of Lausanne University Hospital in Switzerland. Age, gender and BP distribution were collected to fulfill AAMI/ESH/ISO universal standards. Both auscultatory BP references and OptiBP were measured and compared using the opposite arm simultaneous method as described in the 81060-2:2018 ISO norm. RESULTS: A total of 353 paired recordings from 91 subjects were analyzed. For validation criterion 1, the mean ± SD between OptiBP and reference BP recordings was respectively 0.5 ± 7.7 mmHg and 0.4 ± 4.6 mmHg for SBP and DBP. For validation criterion 2, the SD of the averaged BP differences between OptiBP and reference BP per subject was 6.3 mmHg and 3.5 mmHg for SBP and DBP. OptiBP acceptance rate was 85%. CONCLUSION: The smartphone embedded OptiBP cuffless mobile application fulfills the validation requirements of AAMI/ESH/ISO universal standards in a general population for the measurement of SBP and DBP.


Asunto(s)
Hipertensión , Aplicaciones Móviles , Presión Sanguínea , Determinación de la Presión Sanguínea , Monitores de Presión Sanguínea , Humanos , Hipertensión/diagnóstico , Estándares de Referencia , Teléfono Inteligente
4.
Sci Rep ; 10(1): 17827, 2020 10 20.
Artículo en Inglés | MEDLINE | ID: mdl-33082436

RESUMEN

Mobile health diagnostics have been shown to be effective and scalable for chronic disease detection and management. By maximizing the smartphones' optics and computational power, they could allow assessment of physiological information from the morphology of pulse waves and thus estimate cuffless blood pressure (BP). We trained the parameters of an existing pulse wave analysis algorithm (oBPM), previously validated in anaesthesia on pulse oximeter signals, by collecting optical signals from 51 patients fingertips via a smartphone while simultaneously acquiring BP measurements through an arterial catheter. We then compared smartphone-based measurements obtained on 50 participants in an ambulatory setting via the OptiBP app against simultaneously acquired auscultatory systolic blood pressure (SBP), diastolic blood pressure (DBP) and mean blood pressure (MBP) measurements. Patients were normotensive (70.0% for SBP versus 61.4% for DBP), hypertensive (17.1% vs. 13.6%) or hypotensive (12.9% vs. 25.0%). The difference in BP (mean ± standard deviation) between both methods were within the ISO 81,060-2:2018 standard for SBP (- 0.7 ± 7.7 mmHg), DBP (- 0.4 ± 4.5 mmHg) and MBP (- 0.6 ± 5.2 mmHg). These results demonstrate that BP can be measured with accuracy at the finger using the OptiBP smartphone app. This may become an important tool to detect hypertension in various settings, for example in low-income countries, where the availability of smartphones is high but access to health care is low.


Asunto(s)
Auscultación/métodos , Determinación de la Presión Sanguínea/métodos , Aplicaciones Móviles , Teléfono Inteligente , Algoritmos , Humanos , Hipertensión/fisiopatología , Análisis de la Onda del Pulso
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA