RESUMEN
Rationale: Respiratory resistance (Rrs) and reactance (Xrs) as measured by oscillometry and their intrabreath changes have emerged as sensitive parameters for detecting early pathological impairments during tidal breathing. Objectives: This study evaluates the prevalence and association of abnormal oscillometry parameters with respiratory symptoms and respiratory diseases in a general adult population. Methods: A total of 7,560 subjects in the Austrian LEAD (Lung, hEart, sociAl, boDy) Study with oscillometry measurements (computed with the Resmon Pro FULL; Restech Srl) were included in this study. The presence of respiratory symptoms and doctor-diagnosed respiratory diseases was assessed using an interview-based questionnaire. Rrs and Xrs at 5 Hz, their inspiratory and expiratory components, the area above the Xrs curve, and the presence of tidal expiratory flow limitation were analyzed. Normality ranges for oscillometry parameters were defined. Measurements and Main Results: The overall prevalence of abnormal oscillometry parameters was 20%. The incidence of abnormal oscillometry increased in the presence of symptoms or diagnoses: 17% (16-18%) versus 27% (25-29%), P < 0.0001. All abnormal oscillometry parameters except Rrs at 5 Hz were significantly associated with respiratory symptoms/diseases. Significant associations were found, even in subjects with normal spirometry, with abnormal oscillometry incidence rates increasing by 6% (4-8%; P < 0.0001) in subjects with symptoms or diagnoses. Conclusions: Abnormal oscillometry parameters are present in one-fifth of this adult population and are significantly associated with respiratory symptoms and disease. Our findings underscore the potential of oscillometry as a tool for detecting and evaluating respiratory impairments, even in individuals with normal spirometry.
Asunto(s)
Pulmón , Enfermedades Respiratorias , Adulto , Humanos , Oscilometría , Respiración , Espiración , Espirometría , Volumen Espiratorio Forzado , Resistencia de las Vías RespiratoriasRESUMEN
This study investigated the relationship between three respiratory support approaches on lung volume recruitment during the first 2 h of postnatal life in preterm lambs. We estimated changes in lung aeration, measuring respiratory resistance and reactance by oscillometry at 5 Hz. We also measured intratracheal pressure in subsets of lambs. The first main finding is that sustained inflation (SI) applied noninvasively (Mask SI; n = 7) or invasively [endotracheal tube (ETT) SI; n = 6] led to similar rapid lung volume recruitment (â¼6 min). In contrast, Mask continuous positive airway pressure (CPAP) without SI (n = 6) resuscitation took longer (â¼30-45 min) to reach similar lung volume recruitment. The second main finding is that, in the first 15 min of postnatal life, the Mask CPAP without SI group closed their larynx during custom ventilator-driven expiration, leading to intratracheal positive end-expiratory pressure of â¼17 cmH2O (instead of 8 cmH2O provided by the ventilator). In contrast, the Mask SI group used the larynx to limit inspiratory pressure to â¼26 cmH2O (instead of 30 cmH2O provided by the ventilator). These different responses affected tidal volume, being larger in the Mask CPAP without SI group [8.4 mL/kg; 6.7-9.3 interquartile range (IQR)] compared to the Mask SI (5.0 mL/kg; 4.4-5.2 IQR) and ETT SI groups (3.3 mL/kg; 2.6-3.7 IQR). Distinct physiological responses suggest that spontaneous respiratory activity of the larynx of preterm lambs at birth can uncouple pressure applied by the ventilator to that applied to the lung, leading to unpredictable lung pressure and tidal volume delivery independently from the ventilator settings.NEW & NOTEWORTHY We compared invasive and noninvasive resuscitation on lambs at birth, including or not sustained inflation (SI). Lung volume recruitment was faster in those receiving SI. During noninvasive resuscitation, larynx modulation reduced tracheal pressure from that applied to the mask in lambs receiving SI, while it led to increased auto-positive end-expiratory pressure and very large tidal volumes in lambs not receiving SI. Our results highlight the need for individualizing pressures and monitoring tidal volumes during resuscitation at birth.
Asunto(s)
Animales Recién Nacidos , Pulmón , Volumen de Ventilación Pulmonar , Tráquea , Animales , Volumen de Ventilación Pulmonar/fisiología , Ovinos , Pulmón/fisiología , Tráquea/fisiología , Mecánica Respiratoria/fisiología , Presión de las Vías Aéreas Positiva Contínua/métodos , Resucitación/métodos , Intubación Intratraqueal/métodos , Presión , Respiración con Presión Positiva/métodosRESUMEN
Novel therapies are needed for bronchopulmonary dysplasia (BPD) because no effective treatment exists. Mesenchymal stromal cell extracellular vesicles (MSC-sEVs) have therapeutic efficacy in a mouse pup neonatal hyperoxia BPD model. We tested the hypothesis that MSC-sEVs will improve lung functional and structural development in mechanically ventilated preterm lambs. Preterm lambs (â¼129 days; equivalent to human lung development at â¼28 wk gestation) were exposed to antenatal steroids, surfactant, caffeine, and supported by mechanical ventilation for 6-7 days. Lambs were randomized to blinded treatment with either MSC-sEVs (human bone marrow MSC-derived; 2 × 1011 particles iv; n = 8; 4 F/4 M) or vehicle control (saline iv; 4 F/4 M) at 6 and 78 h post delivery. Physiological targets were pulse oximetry O2 saturation 90-94% ([Formula: see text] 60-90 mmHg), [Formula: see text] 45-60 mmHg (pH 7.25-7.35), and tidal volume 5-7 mL/kg. MSC-sEVs-treated preterm lambs tolerated enteral feedings compared with vehicle control preterm lambs. Differences in weight patterns were statistically significant. Respiratory severity score, oxygenation index, A-a gradient, distal airspace wall thickness, and smooth muscle thickness around terminal bronchioles and pulmonary arterioles were significantly lower for the MSC-sEVs group. S/F ratio, radial alveolar count, secondary septal volume density, alveolar capillary surface density, and protein abundance of VEGF-R2 were significantly higher for the MSC-sEVs group. MSC-sEVs improved respiratory system physiology and alveolar formation in mechanically ventilated preterm lambs. MSC-sEVs may be an effective and safe therapy for appropriate functional and structural development of the lung in preterm infants who require mechanical ventilation and are at risk of developing BPD.NEW & NOTEWORTHY This study focused on potential treatment of preterm infants at risk of developing bronchopulmonary dysplasia (BPD), for which no effective treatment exists. We tested treatment of mechanically ventilated preterm lambs with human mesenchymal stromal cell extracellular vesicles (MSC-sEVs). The results show improved respiratory gas exchange and parenchymal growth of capillaries and epithelium that are necessary for alveolar formation. Our study provides new mechanistic insight into potential efficacy of MSC-sEVs for preterm infants at risk of developing BPD.
Asunto(s)
Animales Recién Nacidos , Displasia Broncopulmonar , Vesículas Extracelulares , Pulmón , Células Madre Mesenquimatosas , Respiración Artificial , Animales , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/trasplante , Células Madre Mesenquimatosas/metabolismo , Pulmón/metabolismo , Pulmón/patología , Respiración Artificial/efectos adversos , Respiración Artificial/métodos , Ovinos , Displasia Broncopulmonar/patología , Displasia Broncopulmonar/terapia , Displasia Broncopulmonar/metabolismo , Humanos , FemeninoRESUMEN
OBJECTIVE: This multicenter, international, retrospective study aims to investigate whether respiratory system reactance (Xrs) assessed by respiratory oscillometry on the 7th day of life is associated with respiratory outcomes in preterm infants below 32 weeks' gestation. METHODS: Sinusoidal pressure oscillations (2-5â cmH2O peak-to-peak, 10â Hz) were superimposed on the positive end-expiratory pressure (PEEP). We assessed the association of Xrs z-score with the duration of respiratory support using linear regression and with bronchopulmonary dysplasia (BPD, according to Jensen et al. 2019) using logistic regression. We used the likelihood ratio test to evaluate whether Xrs z-score adds significantly to clinical predictors, including gestational age (GA), birth weight (BW) and the National Institute of Child Health and Human Development (NICHD) BPD prediction model. RESULTS: One hundred and thirty-seven infants (median (Q1, Q3) GA=28.43 (26.11, 30.29) weeks) were included; 44 (32%) developed BPD. Xrs z-score was significantly associated with the duration of respiratory support (R2=0.35). Xrs z-score was significantly higher in infants who developed BPD (p<0.001); the optimal cut-off value was 2.6, associated with 77% sensitivity and 80% specificity. In univariable analysis, per z-score increase in Xrs, the OR for BPD increased by 60% and the respiratory support by eight days. In multivariable analysis, Xrs z-score added significantly to the NICHD model and to GA and BW z-score to predict respiratory support duration (p=0.016 and p=0.014, respectively) and BPD development (p=0.003 and p<0.001, respectively). CONCLUSION: Xrs z-score on the 7th day after birth improves the prediction of respiratory outcome in preterm infants.
RESUMEN
RATIONALE: Lung recruitment and continuous distending pressure (CDP) titration are critical for assuring the efficacy of high-frequency ventilation (HFOV) in preterm infants. The limitation of oxygenation (peripheral oxygen saturation, SpO2) in optimizing CDP calls for evaluating other non-invasive bedside measurements. Respiratory reactance (Xrs) at 10 Hz measured by oscillometry reflects lung volume recruitment and tissue strain. In particular, lung volume recruitment and decreased tissue strain result in increased Xrs values. OBJECTIVES: In extremely preterm infants treated with HFOV as first intention, we aimed to measure the relationship between CDP and Xrs during SpO2-driven CDP optimization. METHODS: In this prospective observational study, extremely preterm infants born before 28 weeks of gestation undergoing SpO2-guided lung recruitment maneuvers were included in the study. SpO2 and Xrs were recorded at each CDP step. The optimal CDP identified by oxygenation (CDPOpt_SpO2) was compared to the CDP providing maximal Xrs on the deflation limb of the recruitment maneuver (CDPXrs). RESULTS: We studied 40 infants (gestational age at birth = 22+ 6-27+ 5 wk; postnatal age = 1-23 days). Measurements were well tolerated and provided reliable results in 96% of cases. On average, Xrs decreased during the inflation limb and increased during the deflation limb. Xrs changes were heterogeneous among the infants for the amount of decrease with increasing CDP, the decrease at the lowest CDP of the deflation limb, and the hysteresis of the Xrs vs. CDP curve. In all but five infants, the hysteresis of the Xrs vs. CDP curve suggested effective lung recruitment. CDPOpt_SpO2 and CDPXrs were highly correlated (ρ = 0.71, p < 0.001) and not statistically different (median difference [range] = -1 [-3; 9] cmH2O). However, CDPXrs were equal to CDPOpt_SpO2 in only 6 infants, greater than CDPOpt_SpO2 in 10, and lower in 24 infants. CONCLUSIONS: The Xrs changes described provide complementary information to oxygenation. Further investigation is warranted to refine recruitment maneuvers and CPD settings in preterm infants.
Asunto(s)
Ventilación de Alta Frecuencia , Recien Nacido Extremadamente Prematuro , Humanos , Recién Nacido , Oscilometría , Pulmón , Mediciones del Volumen Pulmonar/métodos , Ventilación de Alta Frecuencia/métodosRESUMEN
BACKGROUND: We investigated whether combining lung ultrasound scores (LUSs) and respiratory system reactance (Xrs) measured by respiratory oscillometry explains the severity of lung disease better than individual parameters alone. METHODS: We performed a prospective observational study in very preterm infants. Forced oscillations (10 Hz) were applied using a neonatal mechanical ventilator (Fabian HFOi, Vyaire). We used the simultaneous respiratory severity score (RSS = mean airway pressure × FIO2) as a primary outcome. We built linear mixed-effect models to assess the relationship between Xrs z-score, LUS and RSS and compared nested models using the likelihood ratio test (LRT). RESULTS: We enrolled 61 infants (median (Q1, Q3) gestational age = 30.00 (26.86, 31.00) weeks) and performed 243 measurements at a postnatal age of 26 (13, 41) days and postmenstrual age of 33.14 (30.46, 35.86) weeks. Xrs z-score and LUS were independently associated with simultaneous RSS (p < 0.001 for both). The model including Xrs and LUS explained the RSS significantly better than Xrs (p value LRT < 0.001) or LUS alone (p value LRT < 0.001). CONCLUSIONS: Combining LUS and Xrs z-score explains the severity of lung disease better than each parameter alone and has the potential to improve the understanding of the underlying pathophysiology. IMPACT: Combining respiratory system reactance by oscillometry and lung ultrasound score explains the respiratory support requirement (e.g., proxy of the severity of lung disease) significantly better than each parameter alone. We assessed the relationship between lung ultrasound and respiratory system reactance in very preterm infants for the first time. Combining respiratory oscillometry and lung ultrasound has the potential to improve the understanding of respiratory pathophysiology.
Asunto(s)
Enfermedades del Prematuro , Enfermedades Pulmonares , Humanos , Recién Nacido , Adulto , Recien Nacido Prematuro , Pulmón/diagnóstico por imagen , Recién Nacido de muy Bajo Peso , Enfermedades Pulmonares/diagnóstico por imagen , UltrasonografíaRESUMEN
OBJECTIVES: To identify short-term repeatability of forced oscillation technique (FOT) measurement of lung function, assess the lung function response to bronchodilators (BDs) by FOT, and prove the concept that only some very preterm infants manifest a change in lung mechanics in response to BD. STUDY DESIGN: We retrospectively analyzed respiratory system resistance and respiratory system reactance measured by FOT (Fabian HFOi). The measurement short-term repeatability was assessed in 43 patients on 60 occasions; BD responsiveness was assessed using a different data set, including 38 measurements in 18 infants. The coefficient of repeatability was calculated as twice the SD of differences between measurements performed 15 minutes apart. We assessed BD responsiveness by measuring respiratory system resistance and respiratory system reactance before and 15 minutes after administering 200 mcg/kg of nebulized salbutamol. A positive response was defined as an improvement in respiratory system resistance or respiratory system reactance greater than the identified coefficient of repeatability. RESULTS: The coefficient of repeatability was 7.5 cmH2O∗s/L (21%) for respiratory system resistance and 6.3 cmH2O∗s/L (21%) for respiratory system reactance. On average, respiratory system resistance did not change significantly following BD administration, though respiratory system reactance increased significantly (from -32.0 [-50.2, -24.4] to -27.9 [-38.1, -22.0] cmH2O∗s/L, P < .001). Changes in respiratory system resistance or respiratory system reactance after BD were greater than the identified coefficient of repeatability in 8 infants (44%) on 13 (34%) occasions. CONCLUSIONS: We identified a threshold to assess BD responsiveness by FOT in preterm infants. We speculate that FOT could be used to assess and personalize treatment with BD.
Asunto(s)
Resistencia de las Vías Respiratorias , Broncodilatadores , Lactante , Humanos , Recién Nacido , Broncodilatadores/uso terapéutico , Estudios Retrospectivos , Resistencia de las Vías Respiratorias/fisiología , Recien Nacido Prematuro , Pruebas de Función Respiratoria/métodos , Mecánica RespiratoriaRESUMEN
BACKGROUND: Although high-frequency percussive ventilation (HFPV) improves gas exchange, concerns remain about tissue overdistension caused by the oscillations and consequent lung damage. We compared a modified percussive ventilation modality created by superimposing high-frequency oscillations to the conventional ventilation waveform during expiration only (eHFPV) with conventional mechanical ventilation (CMV) and standard HFPV. METHODS: Hypoxia and hypercapnia were induced by decreasing the frequency of CMV in New Zealand White rabbits (n = 10). Following steady-state CMV periods, percussive modalities with oscillations randomly introduced to the entire breathing cycle (HFPV) or to the expiratory phase alone (eHFPV) with varying amplitudes (2 or 4 cmH2O) and frequencies were used (5 or 10 Hz). The arterial partial pressures of oxygen (PaO2) and carbon dioxide (PaCO2) were determined. Volumetric capnography was used to evaluate the ventilation dead space fraction, phase 2 slope, and minute elimination of CO2. Respiratory mechanics were characterized by forced oscillations. RESULTS: The use of eHFPV with 5 Hz superimposed oscillation frequency and an amplitude of 4 cmH2O enhanced gas exchange similar to those observed after HFPV. These improvements in PaO2 (47.3 ± 5.5 vs. 58.6 ± 7.2 mmHg) and PaCO2 (54.7 ± 2.3 vs. 50.1 ± 2.9 mmHg) were associated with lower ventilation dead space and capnogram phase 2 slope, as well as enhanced minute CO2 elimination without altering respiratory mechanics. CONCLUSIONS: These findings demonstrated improved gas exchange using eHFPV as a novel mechanical ventilation modality that combines the benefits of conventional and small-amplitude high-frequency oscillatory ventilation, owing to improved longitudinal gas transport rather than increased lung surface area available for gas exchange.
Asunto(s)
Infecciones por Citomegalovirus , Ventilación de Alta Frecuencia , Animales , Dióxido de Carbono , Oxígeno , Intercambio Gaseoso Pulmonar , Conejos , Respiración ArtificialRESUMEN
BACKGROUND: Abdominal compliance describes the ease of expansion of the abdominal cavity. Several studies highlighted the importance of monitoring abdominal compliance (Cab) during the creation of laparoscopic workspace to individualize the insufflation pressure. The lack of validated clinical monitoring tools for abdominal compliance prevents accurate tailoring of insufflation pressure. Oscillometry, also known as the forced oscillation technique (FOT), is currently used to measure respiratory mechanics and has the potential to be adapted for monitoring abdominal compliance. This study aimed to define, develop and evaluate a novel approach which can monitor abdominal compliance during laparoscopy using endoscopic oscillometry. MATERIALS AND METHODS: Endoscopic oscillometry was evaluated in a porcine model for laparoscopy. A custom-built insufflator was developed for applying an oscillatory pressure signal superimposed onto a mean intra-abdominal pressure. This insufflator was used to measure the abdominal compliance at insufflation pressures ranging from 5 to 20 hPa (3.75 to 15 mmHg). The measurements were compared to the static abdominal compliance, which was measured simultaneously with computed tomography imaging. RESULTS: Endoscopic oscillometry recordings and CT images were obtained in 10 subjects, resulting in 76 measurement pairs for analysis. The measured dynamic Cab ranged between 0.0216 and 0.261 L/hPa while the static Cab based on the CT imaging ranged between 0.0318 and 0.364 L/hPa. The correlation showed a polynomial relation and the adjusted R-squared was 97.1%. CONCLUSIONS: Endoscopic oscillometry can be used to monitor changes in abdominal compliance during laparoscopic surgery, which was demonstrated in this study with a comparison with CT imaging in a porcine laparoscopy model. Use of this technology to personalize the insufflation pressure could reduce the risk of applying excessive pressure and limit the drawbacks of insufflation.
Asunto(s)
Cavidad Abdominal , Insuflación , Laparoscopía , Cavidad Abdominal/cirugía , Animales , Dióxido de Carbono , Humanos , Insuflación/métodos , Laparoscopía/métodos , Neumoperitoneo Artificial/métodos , Presión , PorcinosRESUMEN
Invasive mechanical ventilation (IMV) and exposure to oxygen-rich gas during early postnatal life are contributing factors for long-term pulmonary morbidities faced by survivors of preterm birth and bronchopulmonary dysplasia. The duration of IMV that leads to long-term pulmonary morbidities is unknown. We compared two durations of IMV (3 h vs. 6 days) during the first 6-7 days of postnatal life in preterm lambs to test the hypothesis that minimizing the duration of IMV will improve long-term respiratory system mechanics and structural outcomes later in life. Moderately preterm (â¼85% gestation) lambs were supported by IMV for either 3 h or 6 days before weaning from all respiratory support to become former preterm lambs. Respiratory system mechanics and airway reactivity were assessed monthly from 1 to 6 mo of chronological postnatal age by the forced oscillation technique. Quantitative morphological measurements were made for smooth muscle accumulation around terminal bronchioles and indices of alveolar formation. Minimizing IMV to 3 h led to significantly better (P < 0.05) baseline respiratory system mechanics and less reactivity to methacholine in the first 3 mo of chronological age (2 mo corrected age), significantly less (P < 0.05) accumulation of smooth muscle around peripheral resistance airways (terminal bronchioles), and significantly better (P < 0.05) alveolarization at the end of 5 mo corrected age compared with continuous IMV for 6 days. We conclude that limiting the duration of IMV following preterm birth of fetal lambs leads to better respiratory system mechanics and structural outcomes later in life.
Asunto(s)
Pulmón/fisiopatología , Respiración Artificial/métodos , Respiración , Insuficiencia Respiratoria/terapia , Animales , Animales Recién Nacidos , Femenino , Masculino , Embarazo , OvinosRESUMEN
BACKGROUND: Current criteria for surfactant administration assume that hypoxia is a direct marker of lung-volume de-recruitment. We first introduced an early, non-invasive assessment of lung mechanics by the Forced Oscillation Technique (FOT) and evaluated its role in predicting the need for surfactant therapy. OBJECTIVES: To evaluate whether lung reactance (Xrs) assessment by FOT within 2 h of birth identifies infants who would need surfactant within 24 h; to eventually determine Xrs performance and a cut-off value for early detection of infants requiring surfactant. METHODS: We conducted a prospective, observational, non-randomized study in our tertiary NICU in Milan. Eligible infants were born between 27+0 and 34+6 weeks' gestation, presenting respiratory distress after birth. EXCLUSION CRITERIA: endotracheal intubation at birth, major malformations participation in other interventional trials, parental consent denied. We assessed Xrs during nasal CPAP at 5 cmH2O at 10 Hz within 2 h of life, recording flow and pressure tracing through a Fabian Ventilator for off-line analysis. Clinicians were blinded to FOT results. RESULTS: We enrolled 61 infants, with a median [IQR] gestational age of 31.9 [30.3; 32.9] weeks and birth weight 1490 [1230; 1816] g; 2 infants were excluded from the analysis for set-up malfunctioning. 14/59 infants received surfactant within 24 h. Xrs predicted surfactant need with a cut-off - 33.4 cmH2O*s/L and AUC-ROC = 0.86 (0.76-0.96), with sensitivity 0.85 and specificity 0.83. An Xrs cut-off value of - 23.3 cmH2O*s/L identified infants needing surfactant or respiratory support > 28 days with AUC-ROC = 0.89 (0.81-0.97), sensitivity 0.86 and specificity 0.77. Interestingly, 12 infants with Xrs < - 23.3 cmH2O*s/L (i.e. de-recruited lungs) did not receive surfactant and subsequently required prolonged respiratory support. CONCLUSION: Xrs assessed within 2 h of life predicts surfactant need and respiratory support duration in preterm infants. The possible role of Xrs in improving the individualization of respiratory management in preterm infants deserves further investigation.
Asunto(s)
Pulmón/fisiopatología , Surfactantes Pulmonares/administración & dosificación , Síndrome de Dificultad Respiratoria del Recién Nacido/terapia , Presión de las Vías Aéreas Positiva Contínua , Femenino , Estudios de Seguimiento , Edad Gestacional , Humanos , Recién Nacido , Recien Nacido Prematuro , Masculino , Proyectos Piloto , Estudios Prospectivos , Síndrome de Dificultad Respiratoria del Recién Nacido/fisiopatologíaRESUMEN
Despite recent insights into the dynamic processes during lung aeration at birth, several aspects remain poorly understood. We aimed to characterize changes in lung mechanics during the first inflation at birth and their relationship to changes in lung volume. Intubated preterm lambs (gestational age, 124-127 days; n = 17) were studied at birth. Lung volume changes were measured by electrical impedance tomography (VLEIT). Respiratory system resistance (R5) and oscillatory compliance (Cx5) were monitored with the forced oscillation technique at 5 Hz. Lambs received 3-7 s of 8 cmH2O of continuous distending pressure (CDP) before delivery of a sustained inflation (SI) of 40 cmH2O. The SI was then applied until either Cx5 or the VLEIT or the airway opening volume was stable. CDP was resumed for 3-7 s before commencement of mechanical ventilation. The exponential increases with time of Cx5 and VLEIT from commencement of the SI were characterized by estimating their time constants (τCx5 and τVLEIT, respectively). During SI, a fast decrease in R5 and an exponential increase in Cx5 and VLEIT were observed. Cx5 and VLEIT provided comparable information on the dynamics of lung aeration in all lambs, with τCx5 and τVLEIT being highly linearly correlated (r2 = 0.87, P < 0.001). Cx5 and VLEIT decreased immediately after SI. Despite the standardization of the animal model, changes in Cx5 and R5 both during and after SI were highly variable. Lung aeration at birth is characterized by a fast reduction in resistance and a slower increase in oscillatory compliance, the latter being a direct reflection of the amount of lung aeration.
Asunto(s)
Lesión Pulmonar/prevención & control , Pulmón/fisiopatología , Respiración con Presión Positiva/métodos , Nacimiento Prematuro/fisiopatología , Respiración Artificial/métodos , Mecánica Respiratoria , Animales , Animales Recién Nacidos , Femenino , Edad Gestacional , Masculino , Embarazo , Ovinos , Volumen de Ventilación PulmonarRESUMEN
BACKGROUND: Telemonitoring trials for early detection of acute exacerbations of chronic obstructive pulmonary disease (AECOPD) have provided mixed results. Day-to-day variations in lung function measured by the forced oscillation technique (FOT) may yield greater insight. We evaluated the clinical utility of home telemonitoring of variability in FOT measures in terms of 1) the relationship with symptoms and quality of life (QoL); and 2) the timing of variability of FOT measures and symptom changes prior to AECOPD. METHODS: Daily FOT parameters at 5â Hz (resistance (R) and reactance (X); Resmon Pro Diary, Restech Srl, Milan, Italy), daily symptoms (COPD Assessment Test (CAT)) and 4-weekly QoL data (St George's Respiratory Questionnaire (SGRQ)) were recorded over 8-9â months from chronic obstructive pulmonary disease (COPD) patients. Variability of R and X was calculated as the standard deviation (sd) over 7-day running windows and we also examined the effect of varying window size. The relationship of FOT versus CAT and SGRQ was assessed using linear mixed modelling, daily changes in FOT variability and CAT prior to AECOPD using one-way repeated measures ANOVA. RESULTS: Fifteen participants with a mean±sd age of 69±10â years and a % predicted forced expiratory volume in 1â s (FEV1) of 39±10% had a median (interquartile range (IQR)) adherence of 95.4% (79.0-98.8%). Variability of the inspiratory component of X (indicated by the standard deviation of inspiratory reactance (SDXinsp)) related to CAT and weakly to SGRQ (fixed effect estimates 1.57, 95% CI 0.65-2.49 (p=0.001) and 4.41, 95% CI -0.06 to 8.89 (p=0.05), respectively). SDXinsp changed significantly on the same day as CAT (1â day before AECOPD, both p=0.02) and earlier when using shorter running windows (3â days before AECOPD, p=0.01; accuracy=0.72 for 5-day windows). CONCLUSIONS: SDXinsp from FOT telemonitoring reflects COPD symptoms and may be a sensitive biomarker for early detection of AECOPD.
Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Calidad de Vida , Volumen Espiratorio Forzado , Humanos , Italia , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Pruebas de Función RespiratoriaRESUMEN
Oscillometry (also known as the forced oscillation technique) measures the mechanical properties of the respiratory system (upper and intrathoracic airways, lung tissue and chest wall) during quiet tidal breathing, by the application of an oscillating pressure signal (input or forcing signal), most commonly at the mouth. With increased clinical and research use, it is critical that all technical details of the hardware design, signal processing and analyses, and testing protocols are transparent and clearly reported to allow standardisation, comparison and replication of clinical and research studies. Because of this need, an update of the 2003 European Respiratory Society (ERS) technical standards document was produced by an ERS task force of experts who are active in clinical oscillometry research.The aim of the task force was to provide technical recommendations regarding oscillometry measurement including hardware, software, testing protocols and quality control.The main changes in this update, compared with the 2003 ERS task force document are 1) new quality control procedures which reflect use of "within-breath" analysis, and methods of handling artefacts; 2) recommendation to disclose signal processing, quality control, artefact handling and breathing protocols (e.g. number and duration of acquisitions) in reports and publications to allow comparability and replication between devices and laboratories; 3) a summary review of new data to support threshold values for bronchodilator and bronchial challenge tests; and 4) updated list of predicted impedance values in adults and children.
Asunto(s)
Pulmón , Respiración , Adulto , Pruebas de Provocación Bronquial , Broncodilatadores , Niño , Humanos , OscilometríaRESUMEN
BACKGROUND: Tidal expiratory flow limitation (EFLT) promotes intrinsic PEEP (PEEPi) in patients with chronic obstructive pulmonary disease (COPD). Applying non-invasive ventilation (NIV) with an expiratory positive airway pressure (EPAP) matching PEEPi improves gas exchange, reduces work of breathing and ineffective efforts. We aimed to evaluate the effects of a novel NIV mode that continuously adjusts EPAP to the minimum level that abolishes EFLT. METHODS: This prospective, cross-over, open-label study randomized patients to one night of fixed-EPAP and one night of EFLT-abolishing-EPAP. The primary outcome was transcutaneous carbon dioxide pressure (PtcCO2). Secondary outcomes were: peripheral oxygen saturation (SpO2), frequency of ineffective efforts, breathing patterns and oscillatory mechanics. RESULTS: We screened 36 patients and included 12 in the analysis (age 72 ± 8 years, FEV1 38 ± 14%Pred). The median EPAP did not differ between the EFLT-abolishing-EPAP and the fixed-EPAP night (median (IQR) = 7.0 (6.0, 8.8) cmH2O during night vs 7.5 (6.5, 10.5) cmH2O, p = 0.365). We found no differences in mean PtcCO2 (44.9 (41.6, 57.2) mmHg vs 54.5 (51.1, 59.0), p = 0.365), the percentage of night time with PtcCO2 > 45 mm Hg was lower (62(8,100)% vs 98(94,100)%, p = 0.031) and ineffective efforts were fewer (126(93,205) vs 261(205,351) events/hour, p = 0.003) during the EFLT-abolishing-EPAP than during the fixed-EPAP night. We found no differences in oxygen saturation and lung mechanics between nights. CONCLUSION: An adaptive ventilation mode targeted to abolish EFLT has the potential to reduce hypercapnia and ineffective efforts in stable COPD patients receiving nocturnal NIV. TRIAL REGISTRATION: ClicalTrials.gov, NCT04497090. Registered 29 July 2020-Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04497090 .
Asunto(s)
Espiración/fisiología , Hipercapnia/terapia , Ventilación no Invasiva/métodos , Respiración con Presión Positiva/métodos , Enfermedad Pulmonar Obstructiva Crónica/terapia , Volumen de Ventilación Pulmonar/fisiología , Anciano , Anciano de 80 o más Años , Enfermedad Crónica , Estudios Cruzados , Femenino , Humanos , Hipercapnia/complicaciones , Hipercapnia/fisiopatología , Masculino , Persona de Mediana Edad , Proyectos Piloto , Polisomnografía/métodos , Estudios Prospectivos , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Intercambio Gaseoso Pulmonar/fisiologíaRESUMEN
BACKGROUND: Earlier attempts to deliver effective lung doses of surfactant by aerosolization were unsuccessful, mostly because of technical shortcomings. We aimed at quantifying the lung deposition of poractant alfa with a new supraglottic delivery system for surfactant atomization in an experimental neonatal model. METHODS: The method involved six sedated 1-day-old piglets lying in the lateral decubitus, spontaneously breathing on nasal-mask continuous positive airway pressure (nCPAP). A pharyngeal cannula housing a multi-channel air-blasting atomization catheter was placed through the mouth with its tip above the glottis entrance. In all, 200 mg kg-1 of a 99mTc-surfactant mixture was atomized through the catheter synchronously with inspiration. Six intubated control piglets received an equal amount of intratracheally instilled 99mTc-surfactant mixture. The percentage of the 99mTc-surfactant mixture deposited in the lungs was estimated by scintigraphy. RESULTS: Median (range) deposition in the lungs was 40% (24-68%) after atomization and 87% (55-95%) after instillation (p < 0.001). Overall, almost 80% of the deposited surfactant was in the dependent lung. Effective atomization time (atomizer on) was 28 (17-52) min, yielding an output rate of 0.1-0.2 mL min-1. CONCLUSIONS: Without endotracheal intubation, in spontaneously breathing newborn piglets, this new supraglottic atomizer delivery system attained a median lung deposition of 40% of the nominal dose of surfactant.
Asunto(s)
Productos Biológicos/administración & dosificación , Catéteres , Sistemas de Liberación de Medicamentos/instrumentación , Pulmón/metabolismo , Nebulizadores y Vaporizadores , Fosfolípidos/administración & dosificación , Surfactantes Pulmonares/administración & dosificación , Administración por Inhalación , Aerosoles , Animales , Animales Recién Nacidos , Productos Biológicos/metabolismo , Composición de Medicamentos , Diseño de Equipo , Estudios de Factibilidad , Femenino , Pulmón/diagnóstico por imagen , Masculino , Fosfolípidos/metabolismo , Surfactantes Pulmonares/metabolismo , Sus scrofa , Tecnecio/administración & dosificación , Tecnecio/metabolismo , Distribución TisularRESUMEN
Rationale: The preterm lung is susceptible to injury during transition to air breathing at birth. It remains unclear whether rapid or gradual lung aeration at birth causes less lung injury.Objectives: To examine the effect of gradual and rapid aeration at birth on: 1) the spatiotemporal volume conditions of the lung; and 2) resultant regional lung injury.Methods: Preterm lambs (125 ± 1 d gestation) were randomized at birth to receive: 1) tidal ventilation without an intentional recruitment (no-recruitment maneuver [No-RM]; n = 19); 2) sustained inflation (SI) until full aeration (n = 26); or 3) tidal ventilation with an initial escalating/de-escalating (dynamic) positive end-expiratory pressure (DynPEEP; n = 26). Ventilation thereafter continued for 90 minutes at standardized settings, including PEEP of 8 cm H2O. Lung mechanics and regional aeration and ventilation (electrical impedance tomography) were measured throughout and correlated with histological and gene markers of early lung injury.Measurements and Main Results: DynPEEP significantly improved dynamic compliance (P < 0.0001). An SI, but not DynPEEP or No-RM, resulted in preferential nondependent lung aeration that became less uniform with time (P = 0.0006). The nondependent lung was preferential ventilated by 5 minutes in all groups, with ventilation only becoming uniform with time in the No-RM and DynPEEP groups. All strategies generated similar nondependent lung injury patterns. Only an SI caused greater upregulation of dependent lung gene markers compared with unventilated fetal controls (P < 0.05).Conclusions: Rapidly aerating the preterm lung at birth creates heterogeneous volume states, producing distinct regional injury patterns that affect subsequent tidal ventilation. Gradual aeration with tidal ventilation and PEEP produced the least lung injury.
Asunto(s)
Lesión Pulmonar/terapia , Nacimiento Prematuro/fisiopatología , Respiración Artificial/métodos , Animales , Animales Recién Nacidos , Femenino , Humanos , Recién Nacido , Masculino , Modelos Animales , Embarazo , Factores Protectores , Ovinos , Factores de TiempoRESUMEN
RATIONALE: Early detection of chronic obstructive pulmonary disease (COPD) exacerbations using telemonitoring of physiological variables might reduce the frequency of hospitalization. OBJECTIVES: To evaluate the efficacy of home monitoring of lung mechanics by the forced oscillation technique and cardiac parameters in older patients with COPD and comorbidities. METHODS: This multicenter, randomized clinical trial recruited 312 patients with Global Initiative for Chronic Obstructive Lung Disease grades II to IV COPD (median age, 71 yr [interquartile range, 66-76 yr]; 49.6% grade II, 50.4% grades III-IV), with a history of exacerbation in the previous year and at least one nonpulmonary comorbidity. Patients were randomized to usual care (n = 158) or telemonitoring (n = 154) and followed for 9 months. All telemonitoring patients self-assessed lung mechanics daily, and in a subgroup with congestive heart failure (n = 37) cardiac parameters were also monitored. An algorithm identified deterioration, triggering a telephone contact to determine appropriate interventions. MEASUREMENTS AND MAIN RESULTS: Primary outcomes were time to first hospitalization (TTFH) and change in the EuroQoL EQ-5D utility index score. Secondary outcomes included: rate of antibiotic/corticosteroid prescription; hospitalization; the COPD Assessment Tool, Patient Health Questionnaire-9, and Minnesota Living with Heart Failure questionnaire scores; quality-adjusted life years; and healthcare costs. Telemonitoring did not affect TTFH, EQ-5D utility index score, antibiotic prescriptions, hospitalization rate, or questionnaire scores. In an exploratory analysis, telemedicine was associated with fewer repeat hospitalizations (-54%; P = 0.017). CONCLUSIONS: In older patients with COPD and comorbidities, remote monitoring of lung function by forced oscillation technique and cardiac parameters did not change TTFH and EQ-5D. Clinical trial registered with www.clinicaltrials.gov (NCT 01960907).
Asunto(s)
Monitoreo Fisiológico/métodos , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Telemedicina/métodos , Anciano , Femenino , Humanos , Pulmón/fisiopatología , MasculinoRESUMEN
Respiratory transition at birth involves rapidly clearing fetal lung liquid and preventing efflux back into the lung while aeration is established. We have developed a sustained inflation (SIOPT) individualized to volume response and a dynamic tidal positive end-expiratory pressure (PEEP) (open lung volume, OLV) strategy that both enhance this process. We aimed to compare the effect of each with a group managed with PEEP of 8 cmH2O and no recruitment maneuver (No-RM), on gas exchange, lung mechanics, spatiotemporal aeration, and lung injury in 127 ± 1 day preterm lambs. Forty-eight fetal-instrumented lambs exposed to antenatal steroids were ventilated for 60 min after application of the allocated strategy. Spatiotemporal aeration and lung mechanics were measured with electrical impedance tomography and forced-oscillation, respectively. At study completion, molecular and histological markers of lung injury were analyzed. Mean (SD) aeration at the end of the SIOPT and OLV groups was 32 (22) and 38 (15) ml/kg, compared with 17 (10) ml/kg (180 s) in the No-RM (P = 0.024, 1-way ANOVA). This translated into better oxygenation at 60 min (P = 0.047; 2-way ANOVA) resulting from better distal lung tissue aeration in SIOPT and OLV. There was no difference in lung injury. Neither SIOPT nor OLV achieved homogeneous aeration. Histological injury and mRNA biomarker upregulation were more likely in the regions with better initial aeration, suggesting volutrauma. Tidal ventilation or an SI achieves similar aeration if optimized, suggesting that preventing fluid efflux after lung liquid clearance is at least as important as fluid clearance during the initial inflation at birth.