Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Vasc Access ; 24(1): 35-40, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34088245

RESUMEN

BACKGROUND: Proper securement of central venous catheters plays an important role in onco-hematological pediatric patients. A new subcutaneously anchored securement device has been recently introduced in the clinical practice, and it has been extensively used in children. METHOD: In our study, we have retrospectively investigated the safety and the effectiveness of such device, reviewing the experience of three Italian pediatric oncological units. We have considered only tunneled catheters (cuffed or non-cuffed) inserted in children with malignancy; all types of tunneled central catheters were included in the analysis (both centrally and peripherally inserted) as long as they were secured with a subcutaneously anchored device. We investigated the incidence of dislodgment and of other catheter-related complications, with special attention to local adverse effects potentially related to the securement device. RESULTS: We collected data from 311 tunneled catheters of different caliber: 80.4% were centrally inserted central catheters (CICC), 15.4% were peripherally inserted (PICC), and 4.2% were femorally inserted. Approximately half of the catheters (51%) were non-cuffed. Incidence of dislodgment was very low (2.6%) and the incidence of local pain or inflammation potentially related to the securement device was minimal (1.9%). Catheter related bacteremias were below 1 episode/1000 catheter days. No symptomatic catheter related thrombosis was reported. There was no significant difference in complications comparing cuffed versus non-cuffed catheters, or CICCs versus PICCs, or hematologic tumors versus solid tumors. CONCLUSION: In our retrospective analysis of a vast population of oncological pediatric patients with tunneled central catheters, the subcutaneously anchored securement device was tolerated very well, and it was highly effective in preventing dislodgment, both in cuffed and non-cuffed catheters.


Asunto(s)
Infecciones Relacionadas con Catéteres , Cateterismo Venoso Central , Cateterismo Periférico , Catéteres Venosos Centrales , Trombosis , Humanos , Niño , Catéteres Venosos Centrales/efectos adversos , Estudios Retrospectivos , Cateterismo Venoso Central/efectos adversos , Infecciones Relacionadas con Catéteres/etiología , Trombosis/etiología , Cateterismo Periférico/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA