1.
Eur J Pediatr ; 182(5): 1949-1963, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36809498

RESUMEN

Hybrid closed loop (HCL) systems are the combination of a pump for insulin delivery and a glucose sensor for continuous glucose monitoring. These systems are managed by an algorithm, which delivers insulin on the basis of the interstitial glucose levels. The MiniMed™ 670G system was the first HCL system available for clinical purpose. In this paper, we reviewed the literature about metabolic and psychological outcomes in children, adolescents and young adults with type 1 diabetes treated with MiniMed™ 670G. Only 30 papers responded to the inclusion criteria and thus were considered. All the papers show that the system is safe and effective in managing glucose control. Metabolic outcomes are available up to 12 months of follow-up; longer study period are lacking. This HCL system may improve HbA1c up to 7.1% and time in range up to 73%. The time spent in hypoglycaemia is almost neglectable. Better improvement in blood glucose control is observed in patients with higher HbA1c at HCL system start and larger daily use of auto-mode functionality.     Conclusion: The Medtronic MiniMed™ 670G is safe and well accepted, without any increase in the burden for patients. Some papers report an improvement in the psychological outcomes, but other papers do not confirm this finding. So far, it significantly improves the management of diabetes mellitus in children, adolescents and young adults. Proper training and support by the diabetes team are mandatory. Studies for a period longer than 1 year would be appreciated to better understand the potentiality of this system. What is Known: • The Medtronic MiniMedTM 670G is a hybrid closed loop system which combines a continuous glucose monitoring sensor with an insulin pump. • It has been the first hybrid closed loop system available for clinical purpose. Adequate training and patients support play a key role in diabetes management. What is New: • The Medtronic MiniMedTM 670G may improve HbA1c and CGM metrics up to 1-year of follow-up, but the improvement appears lower than advanced hybrid closed loop systems. This system is effective to prevent hypoglycaemia. • The psychosocial effects remain less understood in terms of improvement of psychosocial outcomes. The system has been considered to provide flexibility and independence by the patients and their caregivers. The workload required to use this system is perceived as a burden by the patients who decrease the use of auto-mode functionality over time.


Asunto(s)
Diabetes Mellitus Tipo 1 , Hipoglucemia , Humanos , Niño , Adolescente , Adulto Joven , Hipoglucemiantes/uso terapéutico , Hemoglobina Glucada , Glucemia , Automonitorización de la Glucosa Sanguínea , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Insulina/uso terapéutico , Hipoglucemia/tratamiento farmacológico
2.
Int J Mol Sci ; 24(6)2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36982665

RESUMEN

Diabetes mellitus constitutes a heterogeneous group of disorders characterized by chronic hyperglycaemia [...].


Asunto(s)
Diabetes Mellitus , Hiperglucemia , Humanos , Diabetes Mellitus/genética , Enfermedad Crónica
3.
J Endocrinol Invest ; 45(9): 1709-1717, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35567736

RESUMEN

PURPOSE: We aimed to evaluate the near-final height (nFHt) in a large cohort of pediatricpatients with growth hormone deficiency (GHD) and to elaborate a new predictive method of nFHt. METHODS: We recruited GHD patients diagnosed between 1987 and 2014 and followed-up until nFHt. To predict the values of nFHt, each predictor was run in a univariable spline. RESULTS: We enrolled 1051 patients. Pre-treatment height was -2.43 SDS, lower than parental height (THt) (-1.09 SDS, p < 0.001). The dose of recombinant human GH (rhGH) was 0.21mg/kg/week at start of treatment. nFHt was -1.08 SDS (height gain 1.27 SDS), higher than pre-treatment height (p < 0.001) and comparable to THt. 1.6% of the patients were shorter than -2 SDS from THt. The rhGH dose at nFHt was 0.19 mg/kg/week, lower than at the start (p < 0.001). The polynomial regression showed that nFHt was affected by gender, THt, age at puberty, height at puberty, age at the end of treatment (F = 325.37, p < 0.0001, R2 87.2%). CONCLUSION: This large national study shows that GHD children can reach their THt. The rhGH/kg/day dose significantly decreased from the start to the end of the treatment. Our model suggests the importance of a timely diagnosis, possibly before puberty, the beneficial effect of long-term treatment with rhGH, and the key-role of THt. Our prediction model has a very acceptable error compared to the majority of other published studies.


Asunto(s)
Enanismo Hipofisario , Hormona de Crecimiento Humana , Estatura , Niño , Estudios de Cohortes , Enanismo Hipofisario/diagnóstico , Enanismo Hipofisario/tratamiento farmacológico , Enanismo Hipofisario/epidemiología , Hormona del Crecimiento/uso terapéutico , Humanos , Pubertad
4.
Diabetes Obes Metab ; 23(11): 2484-2491, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34227214

RESUMEN

AIM: To evaluate the impact of a virtual educational camp (vEC) on glucose control in children and adolescents with type 1 diabetes using a closed-loop control (CLC) system. MATERIALS AND METHODS: This was a prospective multicentre study of children and adolescents with type 1 diabetes using the Tandem Basal-IQ system. Insulin pumps were upgraded to Control-IQ, and children and their parents participated in a 3-day multidisciplinary vEC. Clinical data, glucose metrics and HbA1c were evaluated over the 12 weeks prior to the Control-IQ update and over the 12 weeks after the vEC. RESULTS: Forty-three children and adolescents (aged 7-16 years) with type 1 diabetes and their families participated in the vEC. The median percentage of time in target range (70-180 mg/dL; TIR) increased from 64% (interquartile range [IQR] 56%-73%) with Basal-IQ to 76% (IQR 71%-81%) with Control-IQ (P < .001). After the vEC, more than 75% of participants achieved a TIR of more than 70%. The percentage of time between 180 and 250 mg/dL and above 250 mg/dL decreased by 5% (P < .01) and 6% (P < .01), respectively, while the time between 70 and 54 mg/dL and below 54 mg/dL remained low and unaltered. HbA1c decreased by 0.5% (P < .01). There were no episodes of diabetic ketoacidosis or severe hypoglycaemia. CONCLUSIONS: In this study of children managing their diabetes in a real-world setting, more than 75% of children who participated in a vEC after starting a CLC system could obtain and maintain a TIR of more than 70%. The vEC was feasible and resulted in a significant and persistent improvement in TIR in children and adolescents with type 1 diabetes.


Asunto(s)
Diabetes Mellitus Tipo 1 , Adolescente , Glucemia , Automonitorización de la Glucosa Sanguínea , Niño , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Humanos , Hipoglucemiantes/uso terapéutico , Insulina/uso terapéutico , Sistemas de Infusión de Insulina , Estudios Prospectivos
5.
Nutr Metab Cardiovasc Dis ; 31(7): 2033-2041, 2021 06 30.
Artículo en Inglés | MEDLINE | ID: mdl-34083127

RESUMEN

BACKGROUND AND AIM: Albuminuria and reduced eGFR are hallmarks of Diabetic Kidney Disease in adults. Our aim was to analyze factors associated with albuminuric and non-albuminuric mildly reduced eGFR phenotypes in youths with type 1 diabetes. METHODS AND RESULTS: This multicenter cross-sectional study included 1549 youths (age 5-17 years) with type 1 diabetes enrolled at 14 Italian Pediatric Diabetes Centers. Albuminuria, creatinine, glycosylated hemoglobin (HbA1c), lipids, blood pressure (BP), neutrophils (N) and lymphocytes (L) count were analyzed. Uric acid (UA) was available in 848 individuals. Estimated GFR (eGFR) was calculated using bedside Schwartz's equation. The sample was divided in three phenotypes: 1) normoalbuminuria and eGFR ≥90 mL/min/1.73 m2 (reference category, n = 1204), 2) albuminuric and normal GFR phenotype (n = 106), 3) non-albuminuric mildly reduced GFR (MRGFR) phenotype (eGFR 60-89 mL/min/1.73 m2, n = 239). Albuminuric and non-albuminuric reduced eGFR phenotypes were significantly associated with autoimmune thyroiditis (P =0.028 and P=0.044, respectively). Albuminuric phenotype showed high risk of high HbA1c (P=0.029), high BP (P < 0.001), and low HDL-C (P =0.045) vs reference category. Non-albuminuric MRGFR phenotype showed high risk of high BP (P < 0.0001), low HDL-C (P =0.042), high Triglycerides/HDL-C ratio (P =0.019), and high UA (P < 0.0001) vs reference category. CONCLUSION: Non albuminuric MRGFR phenotype is more prevalent than albuminuric phenotype and shows a worst cardiometabolic risk (CMR) profile). Both phenotypes are associated with autoimmune thyroiditis. Our data suggest to evaluate both albuminuria and eGFR earlier in type 1 diabetes to timely identify young people with altered CMR profile.


Asunto(s)
Albuminuria/epidemiología , Diabetes Mellitus Tipo 1/epidemiología , Nefropatías Diabéticas/epidemiología , Tasa de Filtración Glomerular , Riñón/fisiopatología , Adolescente , Factores de Edad , Albuminuria/diagnóstico , Albuminuria/fisiopatología , Biomarcadores/sangre , Factores de Riesgo Cardiometabólico , Niño , Preescolar , Estudios Transversales , Diabetes Mellitus Tipo 1/diagnóstico , Nefropatías Diabéticas/diagnóstico , Nefropatías Diabéticas/fisiopatología , Femenino , Humanos , Italia/epidemiología , Masculino , Fenotipo , Prevalencia , Estudios Retrospectivos , Medición de Riesgo , Tiroiditis Autoinmune/epidemiología , Población Blanca
6.
Int J Mol Sci ; 22(15)2021 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-34360843

RESUMEN

Wolfram syndrome is a rare autosomal recessive disorder characterized by optic atrophy and diabetes mellitus. Wolfram syndrome type 1 (WFS1) is caused by bi-allelic pathogenic variations in the wolframin gene. We described the first case of WFS1 due to a maternal inherited mutation with uniparental mero-isodisomy of chromosome 4. Diabetes mellitus was diagnosed at 11 years of age, with negative anti-beta cells antibodies. Blood glucose control was optimal with low insulin requirement. No pathogenic variations in the most frequent gene causative of maturity-onset diabetes of the young subtypes were detected. At 17.8 years old, a rapid reduction in visual acuity occurred. Genetic testing revealed the novel homozygous variant c.1369A>G; p.Arg457Gly in the exon 8 of wolframin gene. It was detected in a heterozygous state only in the mother while the father showed a wild type sequence. In silico disease causing predictions performed by Polyphen2 classified it as "likely damaging", while Mutation Tester and Sift suggested it was "polymorphism" and "tolerated", respectively. High resolution SNP-array analysis was suggestive of segmental uniparental disomy on chromosome 4. In conclusion, to the best of our knowledge, we describe the first patient with partial uniparental mero-isodisomy of chromosome 4 carrying a novel mutation in the wolframin gene. The clinical phenotype observed in the patient and the analysis performed suggest that the genetic variant detected is pathogenetic.


Asunto(s)
Cromosomas Humanos Par 4 , Proteínas de la Membrana/genética , Mutación Missense , Disomía Uniparental , Síndrome de Wolfram/genética , Femenino , Humanos , Adulto Joven
7.
Pediatr Diabetes ; 21(8): 1485-1492, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32935887

RESUMEN

BACKGROUND: No studies have assessed if 2-week of continuous glucose monitoring (CGM) data provide good estimation of long-term glycemic control and glucose variability (GV) in pediatric patients with type 1 diabetes (T1D) as in adults. METHODS: Six hundred fifty-four T1D pediatric patients were enrolled and 12-weeks of CGM data, before HbA1c measurement, were collected. Metrics of glycemic control and GV in incremental sampling periods were calculated. The agreement between metrics calculated in the sampling periods and the full 12-week period was assessed with correlation analysis (R2 ), median relative absolute difference (RAD) or absolute difference in the entire study populations and subjects stratified by age, pubertal status, insulin therapy (MDI,CSII), type of CGM (intermittently scanned [isCGM], real-time [rtCGM]), and HbA1c level. RESULTS: Correlations with metrics of the full 12-week period improved by extending the sampling periods. R2 values close to 0.90 using 4-week period were significantly higher than 2-week period, particularly for coefficient of variation, mean glucose SD, percentage of time below the range <70 mg/dL. A significant difference was found comparing the median RAD of 2- and 4-week, especially for mean glucose and coefficient of variation. Similar results were obtained analyzing subjects according to age and pubertal status, whereas in patients with HbA1c ≤7%, using rtCGM and CSII significant correlations were found for 2-week period. CONCLUSIONS: In T1D pediatric subjects, 4-week CGM data better reflects long-term glycemic control and GV in MDI and isCGM users. The 2-week period may be acceptably accurate in CSII and rtCGM users, especially in those with good glycometabolic control.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/metabolismo , Diabetes Mellitus Tipo 1/sangre , Hemoglobina Glucada/metabolismo , Insulina/administración & dosificación , Adolescente , Niño , Preescolar , Diabetes Mellitus Tipo 1/tratamiento farmacológico , Femenino , Estudios de Seguimiento , Humanos , Hipoglucemiantes/administración & dosificación , Inyecciones Subcutáneas , Masculino , Factores de Tiempo
8.
Am J Med Genet A ; 179(10): 2067-2074, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31361394

RESUMEN

This is a retrospective multicenter nationwide Italian study collecting neonatal anthropometric data of Caucasian subjects with Prader-Willi syndrome (PWS) born from 1988 to 2018. The aim of the study is to provide percentile charts for weight and length of singletons with PWS born between 36 and 42 gestational weeks. We collected the birth weight and birth length of 252 male and 244 female singleton live born infants with both parents of Italian origin and PWS genetically confirmed. Percentile smoothed curves of birth weight and length for gestational age were built through Cole's lambda, mu, sigma method. The data were compared to normal Italian standards. Newborns with PWS showed a lower mean birth weight, by 1/2 kg, and a shorter mean birth length, by 1 cm, than healthy neonates. Females with a 15q11-13 deletion were shorter than those with maternal uniparental maternal disomy of chromosome 15 (p < .0001). The present growth curves may be useful as further traits in supporting a suspicion of PWS in a newborn. Because impaired prenatal growth increases risk of health problems later in life, having neonatal anthropometric standards could be helpful to evaluate possible correlations between the presence or absence of small gestational age and some clinical and metabolic aspects of PWS.


Asunto(s)
Antropometría , Síndrome de Prader-Willi/patología , Peso al Nacer , Estatura , Femenino , Edad Gestacional , Humanos , Recién Nacido , Modelos Lineales , Masculino
12.
Circ J ; 80(4): 958-63, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26861187

RESUMEN

BACKGROUND: Small-for-gestational-age (SGA) children have increased cardiovascular risk, but the mediating factors are poorly understood. We hypothesized that birth size could affect the cardiovascular system since childhood in the absence of other risk factors. We investigated endothelial and myocardial function in SGA children with regular catch-up growth. METHODS AND RESULTS: Biochemical markers, blood pressure, flow-mediated vasodilation (FMD), common carotid intima-media thickness (cIMT), anteroposterior diameter of the infrarenal abdominal aorta (APAO) and echocardiographic parameters of left and right ventricular (LV and RV) function were studied in 27 SGA and 25 appropriate-for-gestational-age (AGA) subjects. SGA subjects had a higher homeostasis model assessment index than controls (2.61±1.27 vs. 1.56±0.40, P=0.01), higher cIMT (0.51±0.04 mm vs. 0.45±0.07 mm, P=0.007) and APAO (1.31±1.35 cm vs. 1.30±0.16 cm, P=0.005), and lower FMD (10.11±4.17% vs. 12.34±4.28, P=0.04) than controls. On echocardiography SGA had higher Tei index both at LV and RV than controls (P=0.001). Reduced RV systolic function was also observed in SGA subjects. CONCLUSIONS: SGA subjects had vascular morphological and function abnormalities compared with AGA, which increase their cardiovascular risk profile. Furthermore, a subtle cardiac alteration in both RV and LV functions was seen in SGA patients compared with AGA.


Asunto(s)
Presión Sanguínea , Grosor Intima-Media Carotídeo , Ecocardiografía , Recién Nacido Pequeño para la Edad Gestacional/crecimiento & desarrollo , Miocardio , Función Ventricular Izquierda , Función Ventricular Derecha , Adolescente , Niño , Femenino , Estudios de Seguimiento , Humanos , Masculino
13.
Am J Med Genet A ; 167A(2): 438-44, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25428890

RESUMEN

We provide a detailed clinical and molecular characterization of an 11-year-old female patient presenting with neurodevelopmental delay (NDD), intellectual disability (ID), seizures, stereotypies and dysmorphic features. Chromosomal microarrays analysis (CMA) detected a small, rare de novo deletion on chromosome 12q24.31 encompassing 31 protein-coding RefSeq genes and a microRNA. Phenotypic comparison with molecularly well-defined cases previously reported in the literature harboring an overlapping 12q24.31 microdeletion indicate that these patients shared common clinical features including neurodevelopmental delay, intellectual disability and behavioral problems. Also, seizures and dysmorphic features are frequent and a consistent pattern was recognized. Since there are remarkable resemblance between the patient described here and at least another one previously reported, our report is provides supportive evidence for the existence of an emerging syndrome caused by a microdeletion in 12q24.31. We propose a minimal region shared among patients contributing to the etiology of the common clinical features observed suggesting as candidate, for the first time, the gene SETD1B which is a component of a histone methyltransferase complex. In addition, we speculate on the possible contributive role of the MIR4304 to some clinical features observed in our patient. Evaluation of more patients with well-characterized deletions within 12q24.31, as well as careful clinical assessment of them, is needed to corroborate our hypothesis, to perform a more detailed genotype-phenotype correlation and, finally, to fully delineate this emerging microdeletion syndrome.


Asunto(s)
Deleción Cromosómica , Cromosomas Humanos Par 12 , Huesos Faciales/anomalías , Discapacidad Intelectual/genética , Convulsiones/genética , Conducta Estereotipada , Preescolar , Mapeo Cromosómico , Hibridación Genómica Comparativa , Variaciones en el Número de Copia de ADN , Facies , Femenino , Humanos , Discapacidad Intelectual/diagnóstico , Fenotipo , Convulsiones/diagnóstico
14.
Clin Mol Allergy ; 13(1): 2, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25954139

RESUMEN

BACKGROUND: In the latest decades, epidemiological studies on allergic disorders in children, including atopic dermatitis, rhinitis and asthma, demonstrated a continuous increase in prevalence. However, such studies are usually performed by questionnaires and, sometimes, by skin prick test or in vitro IgE tests, while the portion of allergy sustained by the cell-mediated mechanism is neglected, because the essential test, i.e. the atopy patch test is not performed. METHODS: This cross-sectional survey studied by a specific questionnaire, skin prick test and atopy patch test, an unselected population, represented by the entire scholastic population attending a Primary school and a Junior Secondary school in the rural town of San Marco in Lamis, 12.000 inhabitants (Puglia, Italy). RESULTS: Among the 456 subjects included, 78 (17.1 %) had a positive skin prick test and 57 (12.5 %) had a positive atopy patch test. In particular, 13.4 % of subjects were positive only to skin prick test and 8.8 % were positive only to atopy patch test. The allergen most frequently positive was the house dust mite, with 41 positive results to skin prick test and 55 to atopy patch test, while for pollen positive results concerned almost exclusively the skin prick test. CONCLUSIONS: This survey on an unselected population of children detected a prevalence of positive results to atopy patch test not so distant from the positive results to skin prick test, and in 8.8 % of subjects the atopy patch test was the only positive test. This would suggest to add the atopy patch test in future epidemiological studies on allergy, in order to avoid to overlook the not negligible portion of patients with T-cell-mediated allergy.

15.
Clin Mol Allergy ; 13(1): 18, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26155197

RESUMEN

[This corrects the article DOI: 10.1186/s12948-015-0011-2.].

16.
BMC Med Genet ; 15: 88, 2014 Jul 24.
Artículo en Inglés | MEDLINE | ID: mdl-25056293

RESUMEN

BACKGROUND: Wolfram Syndrome type 2 (WFS2) is considered a phenotypic and genotypic variant of WFS, whose minimal criteria for diagnosis are diabetes mellitus and optic atrophy. The disease gene for WFS2 is CISD2. The clinical phenotype of WFS2 differs from WFS1 for the absence of diabetes insipidus and psychiatric disorders, and for the presence of bleeding upper intestinal ulcers and defective platelet aggregation. After the first report of consanguineous Jordanian patients, no further cases of WFS2 have been reported worldwide. We describe the first Caucasian patient affected by WFS2. CASE PRESENTATION: The proband was a 17 year-old girl. She presented diabetes mellitus, optic neuropathy, intestinal ulcers, sensorineural hearing loss, and defective platelet aggregation to ADP. Genetic testing showed a novel homozygous intragenic deletion of CISD2 in the proband. Her brother and parents carried the heterozygous mutation and were apparently healthy, although they showed subclinical defective platelet aggregation. Long runs of homozygosity analysis from SNP-array data did not show any degree of parental relationship, but the microsatellite analysis confirmed the hypothesis of a common ancestor. CONCLUSION: Our patient does not show optic atrophy, one of the main diagnostic criteria for WFS, but optic neuropathy. Since the "asymptomatic" optic atrophy described in Jordanian patients is not completely supported, we could suppose that the ocular pathology in Jordanian patients was probably optic neuropathy and not optic atrophy. Therefore, as optic atrophy is required as main diagnostic criteria of WFS, it might be that the so-called WFS2 could not be a subtype of WFS. In addition, we found an impaired aggregation to ADP and not to collagen as previously reported, thus it is possible that different experimental conditions or inter-patient variability can explain different results in platelet aggregation. Further clinical reports are necessary to better define the clinical spectrum of this syndrome and to re-evaluate its classification.


Asunto(s)
Envejecimiento Prematuro/genética , Pérdida Auditiva Sensorineural/genética , Proteínas de la Membrana/genética , Enfermedades Mitocondriales/genética , Atrofia Óptica/genética , Enfermedades del Nervio Óptico/genética , Agregación Plaquetaria/genética , Eliminación de Secuencia , Adolescente , Exones , Femenino , Humanos
17.
J Pediatr ; 164(5): 1189-1194.e1, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24518168

RESUMEN

OBJECTIVE: To evaluate clinical and biochemical features of 115 children (98 female, mean age 11.3 ± 3.5 years) with Graves disease to identify possible determinants of remission. STUDY DESIGN: We defined as positive outcome the improvement of clinical features and restoration of euthyroidism or induction of hypothyroidism after antithyroid drug (ATD) therapy and as negative outcome hyperthyroidism persistent over 2 years of ATD therapy or relapsed after ATD withdrawal. RESULTS: Thirty-eight children (33%) had remission after 2 years of ATD therapy. The absence of goiter at diagnosis was correlated with a better outcome. Median thyroid-stimulating hormone receptor antibody (TRAb) values at diagnosis were significantly lower in patients with a positive outcome (P = .031). We found a significant relationship between the time required for TRAb normalization and the patient outcome; TRAb normalization within 1 year from time of Graves disease diagnosis was significantly more common among patients with a positive outcome (P < .0001), and the mean time for TRAb normalization was significantly shorter in patients with a positive outcome (1.3 ± 0.8 years) compared with that observed in patients with a negative outcome (2.5 ± 2.7 years, P = .026). CONCLUSIONS: Although no clinical variable investigated is constantly associated with a definite outcome, the absence of goiter at the diagnosis may be associated with a better outcome. The most relevant predictor of Graves disease outcome was serum level; TRAb at time of Graves disease diagnosis less than 2.5 times the upper reference limit, TRAb normalization during ATD, and TRAb normalization timing each may predict positive outcomes. These results may have a role in the empiric clinical management of pediatric patients with Graves disease.


Asunto(s)
Antitiroideos/uso terapéutico , Enfermedad de Graves/tratamiento farmacológico , Inmunoglobulinas Estimulantes de la Tiroides/sangre , Metimazol/uso terapéutico , Adolescente , Biomarcadores/sangre , Niño , Esquema de Medicación , Monitoreo de Drogas , Femenino , Estudios de Seguimiento , Enfermedad de Graves/sangre , Enfermedad de Graves/inmunología , Humanos , Modelos Logísticos , Masculino , Radioinmunoensayo , Recurrencia , Inducción de Remisión , Estudios Retrospectivos , Resultado del Tratamiento
18.
Diabetes Ther ; 15(2): 343-365, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38038896

RESUMEN

The MiniMed™ 780G is a second-generation automated insulin delivery system that implements a modified proportional-integral-derivative algorithm with some features of an MD-Logic artificial pancreas algorithm. The system may deliver automatic correction boluses up to every 5 min, and it allows the user to choose between three glucose target setpoints (100, 110 and 120 mg/dL). We aimed to review the current evidence on this device in children, adolescents, and young adults living with type 1 diabetes. We screened 783 papers, but only 31 manuscripts were included in this review. Data on metabolic outcomes show that this system is safe as regards severe hypoglycaemia and diabetic ketoacidosis. The glycated haemoglobin may drop to levels about 7%, with CGM reports showing a time in range of 75-80%. The time above range and the time below range are within the recommended target in most of the subjects. Few studies evaluated the psychological outcomes. This system seems to be more effective than the first-generation automated insulin delivery systems. The MiniMed™ 780G has been associated with an improvement in sleep quality in subjects living with diabetes and their caregivers, along with an improvement in treatment satisfaction. Psychological distress is as reduced as the glucose control is improved. We also discuss some case reports describing particular situations in clinical practice. Finally, we think that data show that this system is a further step towards the improvement of the treatment of diabetes as concerns both metabolic and psychological outcomes.

19.
Diabetes Ther ; 15(10): 2133-2149, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39008237

RESUMEN

The Tandem t:slim X2 insulin pump is a second-generation automated insulin delivery system with Control-IQ technology. It consists of an X2 insulin pump, an integrated Dexcom sensor, and an embedded 'Control-IQ' algorithm, which predicts glucose levels 30 min in the future, adapting the programmed basal insulin rates to get glucose levels between 112.5 and 160 mg/dl (8.9 mmol/l). The system delivers automatic correction boluses of insulin when glucose levels are predicted to rise > 180 mg/dl (10 mmol/l). It has been commercially available since 2016. We reviewed the current evidence about the psychological, safety, and exercise-related outcomes of this device in children, adolescents, and young adults living with type 1 diabetes. We screened 552 papers, but only 21 manuscripts were included in this review. Fear of hypoglycemia is significantly reduced in young people with diabetes and their parents. Interestingly, diabetes-related distress is decreased; thus, the system is well accepted by the users. The sleeping quality of subjects living with diabetes and their caregivers is improved to a lesser extent as well. Despite the small number of data, this system is associated with a low rate of exercise-related hypoglycemia. Finally, evidence from the literature shows that this system is safe and effective in improving psychological personal outcomes. Even if further steps toward the fully closed loop are still mandatory, this second-generation automated insulin delivery system reduces the burden of diabetes. It properly addresses most psychological issues in children, adolescents, and young adults with type 1 diabetes mellitus; thus, it appears to be well accepted.

20.
Diabetes Ther ; 2024 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-39292435

RESUMEN

Neonatal diabetes mellitus is a rare disorder of glucose metabolism with onset within the first 6 months of life. The initial treatment is based on insulin infusion. The technologies for diabetes treatment can be very helpful, even if guidelines are still lacking. The current study aimed to provide a comprehensive review of the literature about the safety and efficacy of insulin treatment with technology for diabetes to support clinicians in the management of infants with neonatal diabetes mellitus. A total of 22 papers were included, most of them case reports or case series. The first infants with neonatal diabetes mellitus treated with insulin pumps were described nearly two decades ago. Over the years, continuous glucose monitoring systems were added to treat these individuals, allowing for a better customization of insulin administration. Insulin was diluted in some cases to further minimize the doses. Improvement in technology for diabetes prompted clinicians to use new devices and algorithms for insulin delivery in infants with neonatal diabetes as well. These systems are safe and effective, may shorten hospital stay, and help clinicians weaning insulin during the remission phase in the transient forms or switching from insulin to sulfonylurea when suggested by the molecular diagnosis. New technologies for insulin delivery in infants with neonatal diabetes can be used safely and closed-loop algorithms can work properly in these situations, optimizing blood glucose control.