Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1305-1320, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37950755

RESUMEN

OBJECTIVE: To determine the association between pre-operative central subfield thickness (CST) and post-radiotherapy visual acuity (VA), cystoid macular edema (CME), and intravitreal anti-vascular endothelial growth factor (VEGF) requirement. DESIGN: Single-center retrospective study. PARTICIPANTS: Patients with plaque-irradiated extramacular choroidal melanoma treated between 11/11/2011 and 4/30/2021. Pre-operative CST difference between the affected and unaffected eye was used. Kaplan-Meier analysis and hazard ratios were calculated. RESULTS: Of 85 patients, pre-operative CST was greater in the melanoma-affected eye (vs. fellow eye) by mean of 20.4 µm (median 14.0, range - 60.0-182.0). Greater CST at presentation (vs. fellow eye) was associated with larger tumor diameter (p = 0.02), greater tumor thickness (p < 0.001), and more frequent tumor-related Bruch's membrane rupture (p = 0.006). On univariate analysis of outcome data, greater CST at presentation (vs. fellow eye) was associated with higher 5-year risk (1.09 [1.02-1.17], p = 0.02) of VA 20/200 or worse and increased (1.10 [1.01-1.20], p = 0.03) likelihood for anti-VEGF injections after plaque irradiation. There was no significant association with CME. The association between CST and VA outcome remained significant on multivariate analysis accounting for impact of tumor thickness and radiation dose to optic disc, while tumor distance to fovea was the only significant factor on multivariate analysis for anti-VEGF injections. CONCLUSION: Greater CST at presentation (vs. fellow eye) was associated with worse VA outcome following plaque radiotherapy for choroidal melanoma. Large-sized tumors may contribute to a higher intraocular VEGF burden, potentially leading to greater preoperative CST, which correlates with poor VA outcome post-plaque radiotherapy.


Asunto(s)
Neoplasias de la Coroides , Edema Macular , Melanoma , Neoplasias de la Úvea , Humanos , Estudios Retrospectivos , Factor A de Crecimiento Endotelial Vascular , Melanoma/diagnóstico , Melanoma/radioterapia , Edema Macular/tratamiento farmacológico , Neoplasias de la Coroides/diagnóstico , Neoplasias de la Coroides/radioterapia , Agudeza Visual , Inyecciones Intravítreas , Inhibidores de la Angiogénesis , Tomografía de Coherencia Óptica
2.
J Neuroophthalmol ; 42(1): e159-e172, 2022 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-34812759

RESUMEN

BACKGROUND: To determine risk factors for postradiation optic atrophy (PROA) after plaque radiotherapy for uveal melanoma. METHODS: A single center, retrospective cohort study of patients diagnosed with uveal melanoma involving choroid and/or ciliary body treated with plaque between January 1, 2008, and December 31, 2016. Outcomes included development of PROA with pallor alone or with concomitant neuroretinal rim thinning (NRT). Cox regression analysis was performed to identify risk factors for PROA. RESULTS: Of 78 plaque-irradiated patients, PROA developed in 41 (53%), with concomitant NRT in 15 (19%). Risk factors for PROA of any type included presentation with worse visual acuity (odds ratio [95% confidence interval] 5.6 [2.3-14.1], P < 0.001), higher baseline intraocular pressure (IOP; 14 vs 16 mm Hg) (1.1 [1.0-1.2], P = 0.03), shorter tumor distance to optic disc (1.3 [1.2-1.5], P < 0.001) and foveola (1.2 [1.1-1.3], P < 0.001), subfoveal subretinal fluid (3.8 [2.0-7.1], P < 0.001), greater radiation prescription depth (1.3 [1.1-1.6], P = 0.002), dose to fovea (point dose) (1.01 [1.01-1.02], P < 0.001), and mean (1.02 [1.02-1.03], P < 0.001) and maximum dose to optic disc per 1 Gy increase (1.02 [1.01-1.03], P < 0.001). On multivariate modeling, dose to disc, baseline IOP, and subfoveal fluid remained significant. Subanalysis revealed risk factors for pallor with NRT of greater mean radiation dose to disc (1.03 [1.01-1.05], P = 0.003), higher maximum IOP (17 vs 20 mm Hg) (1.4 [1.2-1.7], P < 0.001), and subfoveal fluid (12 [2-63], P = 0.004). CONCLUSION: PROA may result in NRT in addition to optic disc pallor. Risk factors for PROA included higher radiation dose to optic disc, higher baseline IOP, and subfoveal fluid. Higher maximum IOP contributed to concomitant NRT.


Asunto(s)
Atrofia Óptica , Disco Óptico , Humanos , Presión Intraocular , Melanoma , Disco Óptico/patología , Palidez/patología , Estudios Retrospectivos , Neoplasias de la Úvea
3.
J Appl Clin Med Phys ; 22(8): 72-82, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34231949

RESUMEN

PURPOSE: Eye plaques are widely used for ocular melanoma and provide an effective alternative to enucleation with adequate tumor control. A COMS plaque utilizes a Silastic insert for precise positioning of the radioactive seeds with respect to the scleral surface of the eye; however, due to manufacturing variability, the insert may unintentionally increase or decrease the distance between the sources and tumor. The purpose of this work is to provide guidance in measuring and identifying outliers in Silastic inserts. The importance of regular quality assurance (QA) is illustrated in an experience where a systematic problem was detected and the manufacturer's 22-mm mold was corrected. METHODS: A detailed description of the molds and manufacturing process used to produce Silastic inserts is provided, including photographs of the process steps. The variability in Silastic insert production was evaluated by measuring the thickness of 124 Silastic inserts. An estimate of how the observed Silastic thickness discrepancies impact the dose to the tumor and critical eye structures was performed using homogeneous dose calculations. A standard QA protocol was developed to guide the clinical user. RESULTS: Thickness of the measured Silastic inserts ranged from 1.22 to 2.67 mm, demonstrating variation from the 2.25 mm standard. Six of the 22-mm inserts were outliers (Δthickness >3 standard deviations) and were excluded from the statistics. The outliers were investigated with the help of the manufacturer, who discovered that a systematic error was accidentally introduced into the 22-mm mold. CONCLUSIONS: Due to manufacturing errors or variability, the Silastic inserts used in COMS eye plaques may be thicker or thinner than the design standard. Such variations may impact tumor control or increase the risk of normal tissue side effects. A standardized QA program is recommended to detect variations and communicate unusual findings to the manufacturer.


Asunto(s)
Braquiterapia , Neoplasias del Ojo , Dimetilpolisiloxanos , Neoplasias del Ojo/radioterapia , Humanos , Radioisótopos de Yodo , Método de Montecarlo , Dosificación Radioterapéutica
4.
Pract Radiat Oncol ; 14(1): e9-e19, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37652345

RESUMEN

PURPOSE: Quantitative bibliometrics are increasingly used to evaluate faculty research productivity. This study benchmarks publication rates for radiation oncologists from highly ranked National Cancer Institute-designated cancer centers and reveals how productivity changes over the arc of a career and of the field over time. METHODS AND MATERIALS: Peer-reviewed articles from 1970 to 2022 were obtained using Scopus for the 348 radiation oncologists listed as faculty for the top 10 cancer hospitals ranked by US News and World Report in 2022. Bibliometrics were analyzed for authorships (A˙), authorships where the individual was first or last author (F˙L), the monograph equivalent of authorships (M˙E), h-index, and ha-index (an analog to h-index using M˙E in place of publications). Career start was defined as the year of first publication. Bibliometric inflation was explored by analyzing authorship and bibliometric changes between 1990 and 2022. RESULTS: Publication rates peak, with as much as a 500% increase, 20 to 25 years from the start of a career before declining until retirement. At career ages of 1, 10, 20, and 30 years, the median bibliometrics were A˙ = (1.5, 4.1, 6.5, 7.0) year-1, F˙L = (0.5, 0.9, 1.2, 0.6) year-1, M˙E= (0.2, 0.5, 0.7, 0.8) year-1, h-index = (1, 12, 22, 47), and ha-index = (0.4, 4.4, 6.9, 18.4). With regards to authorship patterns across eras, the median number of authors listed per paper increased by 240% between 1990 and 2022. Meanwhile, research productivity per individual as measured by F˙L and M˙E was unchanged. CONCLUSIONS: The research publication rates of the median radiation oncologist change substantially over the course of their career. Productivity improves steadily for more than 2 decades before peaking and declining. The culture of authorship has also changed between 1990 and 2022. The number of authors listed per paper has trended upwards, which has an inflationary effect on the number of authorships and h-index. Meanwhile, the rate of manuscripts published per faculty has not changed.


Asunto(s)
Neoplasias , Oncólogos de Radiación , Humanos , Publicaciones , Bibliometría , Docentes , Autoria
5.
Brachytherapy ; 2024 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-39368901

RESUMEN

PURPOSE: To design, construct, and evaluate a system for image-guided placement of brachytherapy applicators using electromagnetic tracking (EMT) technology for improved procedure quality and efficiency. The system, named EMVision, provides a three-dimensional display of planned needle sites, visibility of the anatomy and needle position during placement, and reference tracking to account for generator or target anatomy shifts. METHODS: The EMVision EMT guidance system registers CT and EMT reference frames using an automated point-based algorithm according to tandem/ovoid locations. Subsequent needle placement and digitization is guided with an intraluminal EMT sensor and user interface that displays the needle's location in axial, coronal, sagittal, and 3D-volumetric CT views. The interface can overlay contours, preplanned needles, and provide 6DOF compensation for tandem movement during needle placement/manipulation. EMVision accuracy was evaluated in phantom and human cadaver by comparing EMVision's DICOM needle positions with a ground-truth, postimplant CT. RESULTS: Proof of concept was demonstrated for EMT-assisted placement of brachytherapy needles. EMVision accuracy in phantom (mean ± standard deviation) on a brachysuite CT table was 0.76 ± 0.13 mm for needle tips placed up to 75 mm from the tandem/ovoids and 0.52 ± 0.27 mm for needle shafts at distances up to 100 mm from the tandem/ovoids. Performance in human cadaver was similar, with tip and shaft accuracies of 0.77 ± 0.14 mm and 0.40 ± 0.21 mm, respectively. CONCLUSION: EMVision provides sub-millimeter accuracy for the placement of brachytherapy needles without repeated or continuous imaging. The technology can be used to reduce brachytherapy procedure times, improve the correspondence between intended and actual needle positions, or decrease the trainee learning curve.

6.
Med Phys ; 51(6): 4340-4350, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38629912

RESUMEN

BACKGROUND: High dose rate brachytherapy is commonly used in the treatment of prostate cancer. Treatment planning is often performed under transrectal ultrasound (US) guidance, but brachytherapy needles can be challenging to digitize due to the presence of poor US conspicuity and imaging artifacts. The plan accuracy and quality, however, are dependent on the proper visualization of the needles with millimeter accuracy. PURPOSE: This work describes a technique for generating a color overlay of needle locations atop the grayscale US image. Prototype devices were developed to produce vibrations in the brachytherapy needles that generate a high contrast color Doppler (CD) signal that highlights the needle locations with superior contrast and reduced artifacts. Denoted by the acronym color VISION (Vibrationally Induced Shimmering for Identifying an Object's Nature), the technology has the potential to improve applicator conspicuity and facilitate automated applicator digitization. METHODS: Three prototype vibrational devices with frequencies between 200-450 Hz were designed in-house and evaluated with needle implants in a phantom and cadaveric male pelvis using: (1) an actuator attached to the front of a prostate needle template; (2) an actuator attached to the top of the needle template; and (3) a hand-held actuator with a stylet, inserted directly into a needle's inner lumen. Acquired images were postprocessed in MATLAB to evaluate the potential for automated digitization. RESULTS: All prototype devices produced localized shimmering in implanted brachytherapy needles in both the axial and sagittal planes. The template mounted actuators provided better vibrational coupling and ease of operation than the stylet prototype. The Michelson contrast, or visibility, of the shimmering CD signal was 100% compared with ≤40% for B-mode imaging of a single needle. Proof-of-principle for automated applicator digitization using only the CD signal was demonstrated. CONCLUSIONS: The color VISION prototype devices successfully coupled mechanical vibrations into brachytherapy needles to generate US CD shimmering and accurately highlight brachytherapy needle locations. The high contrast and natively registered signal are promising for future work to automate the needle digitization and provide a real-time visual overlay of the applicator on the B-mode US image.


Asunto(s)
Braquiterapia , Agujas , Braquiterapia/instrumentación , Braquiterapia/métodos , Humanos , Masculino , Ultrasonografía/instrumentación , Fantasmas de Imagen , Vibración/uso terapéutico , Radioterapia Guiada por Imagen/instrumentación , Radioterapia Guiada por Imagen/métodos , Color
7.
Med Phys ; 51(10): 7378-7392, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39031886

RESUMEN

BACKGROUND: The pancreas is a complex abdominal organ with many anatomical variations, and therefore automated pancreas segmentation from medical images is a challenging application. PURPOSE: In this paper, we present a framework for segmenting individual pancreatic subregions and the pancreatic duct from three-dimensional (3D) computed tomography (CT) images. METHODS: A multiagent reinforcement learning (RL) network was used to detect landmarks of the head, neck, body, and tail of the pancreas, and landmarks along the pancreatic duct in a selected target CT image. Using the landmark detection results, an atlas of pancreases was nonrigidly registered to the target image, resulting in anatomical probability maps for the pancreatic subregions and duct. The probability maps were augmented with multilabel 3D U-Net architectures to obtain the final segmentation results. RESULTS: To evaluate the performance of our proposed framework, we computed the Dice similarity coefficient (DSC) between the predicted and ground truth manual segmentations on a database of 82 CT images with manually segmented pancreatic subregions and 37 CT images with manually segmented pancreatic ducts. For the four pancreatic subregions, the mean DSC improved from 0.38, 0.44, and 0.39 with standard 3D U-Net, Attention U-Net, and shifted windowing (Swin) U-Net architectures, to 0.51, 0.47, and 0.49, respectively, when utilizing the proposed RL-based framework. For the pancreatic duct, the RL-based framework achieved a mean DSC of 0.70, significantly outperforming the standard approaches and existing methods on different datasets. CONCLUSIONS: The resulting accuracy of the proposed RL-based segmentation framework demonstrates an improvement against segmentation with standard U-Net architectures.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagenología Tridimensional , Aprendizaje Automático , Páncreas , Conductos Pancreáticos , Tomografía Computarizada por Rayos X , Humanos , Conductos Pancreáticos/diagnóstico por imagen , Páncreas/diagnóstico por imagen , Páncreas/anatomía & histología , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos
8.
Phys Med Biol ; 69(7)2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38422544

RESUMEN

Objective. An algorithm was developed for automated positioning of lattice points within volumetric modulated arc lattice radiation therapy (VMAT LRT) planning. These points are strategically placed within the gross tumor volume (GTV) to receive high doses, adhering to specific separation rules from adjacent organs at risk (OARs). The study goals included enhancing planning safety, consistency, and efficiency while emulating human performance.Approach. A Monte Carlo-based algorithm was designed to optimize the number and arrangement of lattice points within the GTV while considering placement constraints and objectives. These constraints encompassed minimum spacing between points, distance from OARs, and longitudinal separation along thez-axis. Additionally, the algorithm included an objective to permit, at the user's discretion, solutions with more centrally placed lattice points within the GTV. To validate its effectiveness, the automated approach was compared with manually planned treatments for 24 previous patients. Prior to clinical implementation, a failure mode and effects analysis (FMEA) was conducted to identify potential shortcomings.Main results.The automated program successfully met all placement constraints with an average execution time (over 24 plans) of 0.29 ±0.07 min per lattice point. The average lattice point density (# points per 100 c.c. of GTV) was similar for automated (0.725) compared to manual placement (0.704). The dosimetric differences between the automated and manual plans were minimal, with statistically significant differences in certain metrics like minimum dose (1.9% versus 1.4%), D5% (52.8% versus 49.4%), D95% (7.1% versus 6.2%), and Body-GTV V30% (20.7 c.c. versus 19.7 c.c.).Significance.This study underscores the feasibility of employing a straightforward Monte Carlo-based algorithm to automate the creation of spherical target structures for VMAT LRT planning. The automated method yields similar dose metrics, enhances inter-planner consistency for larger targets, and requires fewer resources and less time compared to manual placement. This approach holds promise for standardizing treatment planning in prospective patient trials and facilitating its adoption across centers seeking to implement VMAT LRT techniques.


Asunto(s)
Algoritmos , Benchmarking , Humanos , Estudios Prospectivos , Método de Montecarlo , Órganos en Riesgo
9.
Artículo en Inglés | MEDLINE | ID: mdl-39299551

RESUMEN

PURPOSE: The optimal approach for partial breast irradiation (PBI) is unknown. We investigated a novel de-intensified 3-fraction PBI regimen for photons, protons, and brachytherapy. METHODS AND MATERIALS: A multicenter nonrandomized controlled trial with the primary outcome of adverse cosmesis at 3 years versus before PBI. Eligibility criteria were age ≥50 years treated with breast-conserving surgery for node-negative estrogen receptor-positive (ER+) invasive breast cancer or any ductal carcinoma in situ (DCIS) measuring ≤2.5 cm. Photon and proton PBI were prescribed 21.9 Gy (relative biological effectiveness) and brachytherapy 21 Gy in 3 fractions. Radiation therapy technique and adjuvant endocrine therapy were selected at physician and patient discretion. RESULTS: Between June 17, 2015, and July 13, 2017, 161 eligible patients were treated with photons (56), protons (49), or brachytherapy (56). Median patient age was 66.8 years. One hundred twenty-six (78.3%) had invasive breast cancer (all ER+) and 35 (21.7%) had DCIS (88.6% ER+). Fifty-four percent of patients with invasive breast cancer and 25.8% of patients with ER+ DCIS initiated and adhered to the prescribed endocrine therapy. The proportion of patients with adverse cosmesis (by trained nurse assessment) was 14.5% at baseline and 2.3% at 3 years (difference, -12.2%; 95% CI, -100% to -6.4%). Adverse cosmesis at the last follow-up, with a median follow-up of 5 years, was 5.7% by nurse assessment, 5.6% by panel assessment of digital photographs, and 5.2% by patient self-report. There were no observed clinically meaningful changes in other patient-reported outcomes, and just 2 grade 2 or higher adverse events, both grade 2, in the brachytherapy cohort. Five-year local recurrence-free survival and progression-free survival were 98.0% and 95.5%, respectively. There were no local recurrences among 60 patients with invasive breast cancer and Ki67 ≤13.25%. CONCLUSIONS: Deintensified 3-day PBI provided favorable disease control, tolerability, and cosmetic outcomes, meeting the prespecified criteria for acceptability. This approach is an attractive option for patients with small node-negative ER+ breast cancer and DCIS.

10.
J Appl Clin Med Phys ; 14(5): 115-26, 2013 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-24036864

RESUMEN

A total skin electron (TSE) floor technique is presented for treating patients who are unable to safely stand for extended durations. A customized flattening filter is used to eliminate the need for field junctioning, improve field uniformity, and reduce setup time. The flattening filter is constructed from copper and polycarbonate, fits into the linac's accessory slot, and is optimized to extend the useful height and width of the beam such that no field junctions are needed during treatment. A TSE floor with flattening filter (TSE FF) treatment course consisted of six patient positions: three supine and three prone. For all treatment fields, electron beam energy was 6 MeV; collimator settings were an x of 30 cm, y of 40 cm, and θcoll of 0°; and a 0.4 cm thick polycarbonate spoiler was positioned in front of the patient. Percent depth dose (PDD) and photon contamination for the TSE FF technique were compared with our standard technique, which is similar to the Stanford technique. Beam profiles were measured using radiochromic film, and dose uniformity was verified using an anthropomorphic radiological phantom. The TSE FF technique met field uniformity requirements specified by the American Association of Physicists in Medicine Task Group 30. TSE FF R80 ranges from 4 to 4.8 mm. TSE FF photon contamination was ~ 3%. Anthropomorphic radiological phantom verification demonstrated that dose to the entire skin surface was expected to be within about ±15% of the prescription dose, except for the perineum, scalp vertex, top of shoulder, and soles of the feet. The TSE floor technique presented herein eliminates field junctioning, is suitable for patients who cannot safely stand during treatment, and provides comparable quality and uniformity to the Stanford technique.


Asunto(s)
Electrones/uso terapéutico , Planificación de la Radioterapia Asistida por Computador , Enfermedades de la Piel/radioterapia , Humanos , Método de Montecarlo , Aceleradores de Partículas , Fantasmas de Imagen , Posición Prona , Dosificación Radioterapéutica
11.
Med Phys ; 50(3): 1418-1427, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36511174

RESUMEN

BACKGROUND: Applicator conspicuity in ultrasound-guided brachytherapy procedures is commonly impaired by imaging artifacts or non-ideal imaging geometry, which can slow down applicator position digitization and increase the geometric uncertainty of the delivered dose distribution. PURPOSE: The purpose of this study was to improve the conspicuity of high-dose rate (HDR) brachytherapy needles under B-mode ultrasound imaging by applying an echogenic surface coating. Our hypothesis was that an echogenic coating would reduce artifacts and improve needle visualization within regions of signal degradation. METHODS: In this study, 17-gauge, 25-cm long titanium HDR brachytherapy needles were coated with acoustically reflective microspheres over a 2.5 cm region starting from the needle tip. Three coating thicknesses (27 µm, 40 µm, 64 µm) were compared against an uncoated control needle. The coated and uncoated needles were imaged using B-mode ultrasound in a tissue-equivalent prostate phantom and in a cadaverous male pelvis using a transrectal probe. Needle conspicuity was assessed under multiple conditions: a single needle implant, an implant with multiple needles between the probe and the needle of interest, and an angled needle implant. All images were assessed qualitatively for needle conspicuity and the presence of artifacts and quantitatively using grey-scale image intensity values. RESULTS: The 64 µm echogenic coating reduced the magnitude of reverberation artifacts by 31 ± 14% and comet tail artifacts by 40%-70%. The echogenic coating also improved needle contrast, measured by the relative differences in signal intensity compared with the adjacent environment, when needles were angled up to 30° with respect to the transducer probe in the cadaver. The improvements in conspicuity and artifact reduction increased with increasing coating thickness. The performance of the needles coated with the 64 µm thickness was qualitatively superior and yielded high-contrast, well-circumscribed signals in the cadaverous male pelvis, even under situations where a needle was acoustically shadowed by multiple other needles. CONCLUSIONS: An echogenic surface coating reduced imaging artifacts and improved needle conspicuity under realistic clinical conditions for ultrasound-based prostate or gynecological brachytherapy. The improved conspicuity has the potential to improve the efficiency of needle placement and the accuracy of needle position digitization during brachytherapy procedures.


Asunto(s)
Braquiterapia , Neoplasias de la Próstata , Masculino , Humanos , Braquiterapia/métodos , Ultrasonografía , Agujas , Próstata/diagnóstico por imagen , Fantasmas de Imagen , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia
12.
Brachytherapy ; 22(6): 761-768, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37652777

RESUMEN

PURPOSE: Suboptimal ultrasound conspicuity of the brachytherapy applicator can lead to inaccurate image reconstructions of the applicator resulting in decreased tumor control or increased normal tissue dose. This feasibility study aims to improve ultrasound conspicuity of high-dose rate (HDR) brachytherapy needles by modifying the surface of the needles to produce a color Doppler twinkling signature. MATERIALS AND METHODS: Surface modifications of standard 17-gauge titanium HDR brachytherapy needles included laser-scribing, application of polymethyl methacrylate (PMMA), and coating with a commercially available echogenic coating. Laser-scribing was performed with variable widths (0.1-1 mm) and depths (10-100 µm). The echogenic coating was applied with 3 different thicknesses (27, 40, and 64 µm). Unmodified and modified needles were imaged under B-mode and color Doppler ultrasound in phantom and cadaver, and the signal strength was recorded. RESULTS: Laser-scribed, PMMA-coated, and echogenic-coated brachytherapy needles produced a twinkling signature along the needle shaft on color Doppler ultrasound. Twinkling was observed with laser-scribe depths >20 µm and widths >0.1 mm and from echogenic coatings 40 µm and 64 µm thick. Twinkling was not observed with unmodified needles. The twinkling signature had a spectral composition with a uniform magnitude between the velocities of 2 to 16 cm/s. CONCLUSIONS: Color Doppler ultrasound of surface-modified brachytherapy applicators may improve applicator conspicuity aiding applicator placement and digitization. HDR brachytherapy needles may be modified to produce the twinkling signature via laser-scribing, PMMA rings, or applying an echogenic coating.


Asunto(s)
Braquiterapia , Masculino , Humanos , Braquiterapia/métodos , Polimetil Metacrilato , Próstata , Ultrasonografía , Agujas
13.
Adv Radiat Oncol ; 8(6): 101289, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37457824

RESUMEN

Purpose: Purpose: Subtotal skin electron beam therapy may be an option for patients with cutaneous lymphoma receiving radiation therapy to treat large areas of their skin but may benefit from sparing specific areas that may have had previous radiation therapy, are of specific cosmetic concern, and/or show no evidence of disease. We report here on the design, implementation, and dosimetric characteristics of a reusable and transparent customizable shield for use with the large fields used to deliver total skin electron beam therapy at extended distance with a conventional linear accelerator. Methods and Materials: A shield was designed and manufactured consisting of acrylic blocks that can be mounted on a steel frame to allow patient-specific shielding. The dosimetry of the device was measured using radiochromic film. Results: The shield is easy to use and well-tolerated for patient treatment, providing minimal electron transmission through the shield with a sharp penumbra at the field edge, with no increase in x-ray dose. We report on the dosimetry of a commercial device that has been used to treat more than 30 patients to date. Conclusions: The customizable shield is well suited to providing patient-specific shielding for subtotal skin electron beam therapy.

14.
Phys Med ; 111: 102616, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37311338

RESUMEN

PURPOSE: To provide clinical guidance for centers wishing to implement photon spatially fractionated radiation therapy (SFRT) treatments using either a brass grid or volumetric modulated arc therapy (VMAT) lattice approach. METHODS: We describe in detail processes which have been developed over the course of a 3-year period during which our institution treated over 240 SFRT cases. The importance of patient selection, along with aspects of simulation, treatment planning, quality assurance, and treatment delivery are discussed. Illustrative examples involving clinical cases are shown, and we discuss safety implications relevant to the heterogeneous dose distributions. RESULTS: SFRT can be an effective modality for tumors which are otherwise challenging to manage with conventional radiation therapy techniques or for patients who have limited treatment options. However, SFRT has several aspects which differ drastically from conventional radiation therapy treatments. Therefore, the successful implementation of an SFRT treatment program requires the multidisciplinary expertise and collaboration of physicians, physicists, dosimetrists, and radiation therapists. CONCLUSIONS: We have described methods for patient selection, simulation, treatment planning, quality assurance and delivery of clinical SFRT treatments which were built upon our experience treating a large patient population with both a brass grid and VMAT lattice approach. Preclinical research and patient trials aimed at understanding the mechanism of action are needed to elucidate which patients may benefit most from SFRT, and ultimately expand its use.


Asunto(s)
Neoplasias , Radioterapia de Intensidad Modulada , Humanos , Fraccionamiento de la Dosis de Radiación , Neoplasias/radioterapia , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos
15.
Clin Transl Radiat Oncol ; 41: 100639, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37251618

RESUMEN

Background and purpose: To evaluate the long-term outcome of accelerated partial breast irradiation utilizing intraoperatively placed applicator-based brachytherapy (ABB) in early-stage breast cancer. Materials and methods: From our prospective registry, 223 patients with pTis-T2, pN0/pN1mic breast cancer were treated with ABB. The median treatment duration including surgery and ABB was 7 days. The prescribed doses were 32 Gy/8 fx BID (n = 25), 34 Gy/10 fx BID (n = 99), and 21 Gy/3 fx QD (n = 99). Endocrine therapy (ET) adherence was defined as completion of planned ET or ≥ 80% of the follow-up (FU) period. Cumulative incidence of ipsilateral breast tumor recurrence (IBTR) was estimated and influencing factors for IBTR-free survival rate (IBTRFS) were analyzed. Results: 218/223 patients had hormone receptor-positive tumors, including 38 (17.0%) with Tis and 185 (83.0%) with invasive cancer. After a median FU of 63 months, 19 (8.5%) patients had recurrence [17 (7.6%) with an IBTR]. Rates of 5-year IBTRFS and DFS were 92.2% and 91.1%, respectively. The 5-year IBTRFS rates were significantly higher for post-menopausal women (93.6% vs. 66.4%, p = 0.04), BMI < 30 kg/m2 (97.4% vs. 88.1%, p = 0.02), and ET-adherence (97.5% vs. 88.6%, p = 0.02). IBTRFS did not differ with dose regimens. Conclusions: Postmenopausal status, BMI < 30 kg/m2, and ET- adherence predicted favorable IBTRFS. Our results highlight the importance of careful patient selection for ABB and encouragement of ET compliance.

16.
Brachytherapy ; 21(4): 520-531, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35422402

RESUMEN

PURPOSE: To automate the segmentation of treatment applicators on computed tomography (CT) images for high-dose-rate (HDR) brachytherapy prostate patients implanted with titanium needles with the goals of improving plan quality and reducing the patient's time under anesthesia. METHODS: The investigation was performed using 57 retrospective, interstitial prostate treatments randomly assigned to training (n = 27), validation (n = 10), and testing (n = 20). Unique to this work, the CT image set was reformatted into 2D sagittal slices instead of the default axial orientation. A deep learning-based segmentation was performed using a 2D U-Net architecture followed by a density-based linkage clustering algorithm to classify individual catheters in 3D. Potential confounders, such as gold seeds and conjoined applicators with intersecting needle geometries, were corrected using a customized polynomial fitting algorithm. The geometric agreement of the automated digitization was evaluated against the clinically treated manual digitization to measure tip and shaft errors in the reconstruction. RESULTS: The proposed algorithm achieved tip and shaft agreements of -0.1 ± 0.6 mm (range -1.8 mm to 1.4 mm) and 0.13 ± 0.09 mm (maximum 0.96 mm), respectively on a data set with 20 patients and 353 total needles. Our method was able to separate all intersecting applicators reliably. The time to generate the automated applicator digitization averaged approximately 1 min. CONCLUSIONS: Using sagittal instead of axial images for 2D segmentation of interstitial brachytherapy applicators produced submillimeter agreement with manual segmentation. The automated digitization of interstitial applicators in prostate brachytherapy has the potential to improve quality and consistency while reducing the patient's time under anesthesia.


Asunto(s)
Braquiterapia , Aprendizaje Profundo , Braquiterapia/métodos , Humanos , Masculino , Próstata , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
17.
Brachytherapy ; 21(1): 120-127, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34706854

RESUMEN

PURPOSE: This is a multi-institutional report on inter-observer and inter-instrument variation in the calibration of the absorbed dose rate for a planar 32P beta emitting brachytherapy source. Measurement accuracy is essential since the dose profile is steep and the source is used for the treatment of tumors that are located in close proximity to healthy nervous system structures. METHODS AND MATERIALS: An RIC-100 32P source was calibrated by three institutions using their own equipment and following their standard procedures. The first institution calibrated the source with an electron diode and EBT3 film. The second institution used an electron diode. The third institution used HD810 film. Additionally, each institution was asked to calibrate the source using an electron diode and procedure that was shared among all institutions and shipped along with the radiation source. The dose rate was reported in units of cGy*min-1 at a water equivalent depth of 1 mm. RESULTS: Close agreement was observed in the measurements from different users and equipment. The variation across all diode detectors and institutions had a standard deviation of 1.8% and maximum difference of 4.6%. The observed variation among two different diode systems used within the same institution had a mean difference of 1.6% and a maximum variation of 1.8%. The variations among film and diode systems used within the same institution had a mean difference of 2.9% and a maximum variation of 4.3% CONCLUSIONS: The absorbed dose rate measurement protocol of the planar beta-emitting 32P source permits consistent dosimetry across three institutions and five different electron diode and radiochromic film systems. The methodologies presented herein should enable measurement consistency among other clinical users, which will help ensure high quality patient treatments and outcomes analysis.


Asunto(s)
Braquiterapia , Braquiterapia/métodos , Calibración , Dosimetría por Película , Humanos , Radiometría/métodos , Dosificación Radioterapéutica , Agua
18.
Brachytherapy ; 21(1): 63-74, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34732290

RESUMEN

PURPOSE: Brachytherapy is an essential technique to deliver radiation therapy and is involved in the treatment of multiple disease sites as monotherapy or as an adjunct to external beam radiation therapy. With a growing focus on the cost and value of cancer treatments as well as new payment models, it is essential that standardized quality measures and metrics exist to allow for straightforward assessment of brachytherapy quality and for the development of clinically significant and relevant clinical data elements. We present the American Brachytherapy Society consensus statement on quality measures and metrics for brachytherapy as well as suggested clinical data elements. METHODS AND MATERIALS: Members of the American Brachytherapy Society with expertise in disease site specific brachytherapy created a consensus statement based on a literature review and clinical experience. RESULTS: Key quality measures (ex. workup, clinical indications), dosimetric metrics, and clinical data elements for brachytherapy were evaluated for each modality including breast cancer, cervical cancer, endometrial cancer, prostate cancer, keratinocyte carcinoma, soft tissue sarcoma, and uveal melanoma. CONCLUSIONS: This consensus statement provides standardized quality measures and dosimetric quality metrics as well as clinical data elements for each disease site to allow for standardized assessments of brachytherapy quality. Moving forward, a similar paradigm can be considered for external beam radiation therapy as well, providing comprehensive radiation therapy quality measures, metrics, and clinical data elements that can be incorporated into new payment models.


Asunto(s)
Braquiterapia , Oncología por Radiación , Neoplasias de la Úvea , Benchmarking , Braquiterapia/métodos , Humanos , Masculino , Indicadores de Calidad de la Atención de Salud , Estados Unidos
19.
Biophys J ; 101(2): L5-7, 2011 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-21767475

RESUMEN

DNA experiences torsional stress resulting from the activities of motor enzymes and bound proteins. The mechanisms by which this torsional stress is dissipated to maintain DNA structural integrity are not fully known. Here, we show that a Holliday junction can limit torsion by coupling rotation to translocation and torque to force. The torque required to mechanically migrate through individual junctions was found to be an order of magnitude smaller than that required to melt DNA. We also directly show that substantially more torque was required to migrate through even a single-base sequence heterology, which has important implications for the activity of junction-migrating enzymes.


Asunto(s)
Biofisica/métodos , ADN Cruciforme/metabolismo , Torque , Secuencia de Bases , Pinzas Ópticas , Recombinación Genética
20.
Brachytherapy ; 20(1): 189-199, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33187821

RESUMEN

PURPOSE: Radiation side effects and visual outcome for uveal melanoma patients managed with plaque radiotherapy are dependent on the radiation dose administered to the tumor and nearby healthy tissues. We have developed an open-source software tool, EyeDose, to simplify and standardize tumor and critical structure dose reporting for Collaborative Ocular Melanoma Study eye plaques. METHODS AND MATERIALS: EyeDose is a MATLAB-based program that calculates point dose and volume dose metrics for standard models of the tumor and critical ocular structures. It uses published three-dimensional dose distributions for eye plaques, calculated with Monte Carlo methods, which are oriented with respect to the eye using the tumor's position on a fundus diagram. A standard model for the ocular structures was created using published measurements and patient CT scans. EyeDose reports radiation statistics for the fovea, optic disc, lens, lacrimal gland, retina, and tumor. The dosimetric margin for implant placement uncertainty is also calculated. RESULTS: EyeDose calculations were validated against previously published Monte Carlo results for eight different tumor positions, including the dose to the fovea, optic disc, lacrimal gland, lens, and along the central axis. EyeDose accepts a spreadsheet input for rapidly processing large retrospective patient data sets, with an average run time of <40 s per patient. EyeDose is published as an open-source tool for easy adaptation at different institutions. CONCLUSIONS: EyeDose calculates radiation statistics for Collaborative Ocular Melanoma Study eye plaque patients with Monte Carlo accuracy and without a treatment planning system. EyeDose streamlines data collection for large retrospective studies and can also be used prospectively to assess plaque applicability.


Asunto(s)
Braquiterapia , Neoplasias del Ojo , Melanoma , Disco Óptico , Braquiterapia/métodos , Neoplasias del Ojo/radioterapia , Humanos , Radioisótopos de Yodo , Melanoma/radioterapia , Método de Montecarlo , Dosis de Radiación , Radiometría , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA