Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Blood Purif ; 49(3): 356-363, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31812967

RESUMEN

BACKGROUND/AIMS: Trajectory of heart rate variability (HRV) represents a noninvasive real-time measure of autonomous nervous system (ANS) and carries the capability of providing new insights into the hemodynamic compensation reserve during hemodialysis (HD). However, studies on HRV reproducibility during HD are scarce and did not refer to different reading periods. In this observational study, we aimed to establish the best suited and most reliable and reproducible HRV index in routine HD treatments including different reading rates. METHODS: HRV was characterized by standardized mathematical variation expressions of R/R' intervals: SD of all R/R' intervals (ms), square root of the root mean square of the sum of all differences between adjacent R/R' intervals (ms), percentage of consecutive R/R' intervals that differ by >50 ms (%), low-frequency spectral analysis HRV (LF, expressing sympathetic activity), and high-frequency HRV (HF, expressing parasympathetic activity). To compare robustness of these HRV indices during HD procedures, we compared HRV indices means between different HD sessions and controlled for association with clinical parameters. RESULTS: In 72 HD treatments of 34 patients, we detected the highest reproducibility (89%) of HRV measures when analyzing the low-frequency to high-frequency (LF/HF) ratio in long-term (3 h) readings. Long-term LF/HF was able to discriminate -between patients with and without heart failure NYHA classes ≥3 (p = 0.009) and type 2 diabetes (p = 0.023). We were unable to study relationships between ANS and intradialytic complications because they did not appear in our cohort. Short-term readings of HRV indices did not show any significance of pattern change during HD. CONCLUSION: In summary, our data provide evidence for high robustness of long-term LF/HF in analyzing HRV in HD patients using future automated monitoring systems. For short-term analysis, mathematical real-time analysis must evolve.


Asunto(s)
Frecuencia Cardíaca , Diálisis Renal , Adulto , Anciano , Diabetes Mellitus Tipo 2/diagnóstico , Femenino , Insuficiencia Cardíaca/diagnóstico , Humanos , Fallo Renal Crónico/terapia , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA