Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Methods ; 201: 65-73, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-33812016

RESUMEN

A candidate digital PCR (dPCR)-based reference measurement procedure for quantification of human cytomegalovirus (hCMV) was evaluated in 10 viral load comparison schemes (seven external quality assessment (EQA) and three additional training schemes) organized by INSTAND e.V. over four years (between September 2014 and March 2018). Four metrology institutes participated in these schemes using the same extraction method and dPCR measurement procedure for the hCMV specific target sequence of UL54 gene. The calibration independent reference measurement procedure results from the metrology institutes were compared to the results of the clinical diagnostic laboratories applying hCMV qPCR measurement procedures calibrated to reference materials. While the criteria for the acceptable deviation from the target value interval for INSTAND's EQA schemes is from -0.8 log10 to +0.8 log10, the majority of dPCR results were between -0.2 log10 to +0.2 log10. Only 4 out of 45 results exceeded this interval with the maximum deviation of -0.542 log10. In the training schemes containing samples with lower hCMV concentrations, more than half of the results deviated less than ±0.2 log10 from the target value, while more than 95% deviated less than ±0.4 log10 from the target value. Evaluation of intra- and inter-laboratory variation of dPCR results confirmed high reproducibility and trueness of the method. This work demonstrates that dPCR has the potential to act as a calibration independent reference measurement procedure for the value assignment of hCMV calibration and reference materials to support qPCR calibration as well as ultimately for routine hCMV load testing.


Asunto(s)
Citomegalovirus , Calibración , Citomegalovirus/genética , Humanos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Reproducibilidad de los Resultados
2.
Clin Chem ; 64(9): 1296-1307, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29903874

RESUMEN

BACKGROUND: Genetic testing of tumor tissue and circulating cell-free DNA for somatic variants guides patient treatment of many cancers. Such measurements will be fundamental in the future support of precision medicine. However, there are currently no primary reference measurement procedures available for nucleic acid quantification that would support translation of tests for circulating tumor DNA into routine use. METHODS: We assessed the accuracy of digital PCR (dPCR) for copy number quantification of a frequently occurring single-nucleotide variant in colorectal cancer (KRAS c.35G>A, p.Gly12Asp, from hereon termed G12D) by evaluating potential sources of uncertainty that influence dPCR measurement. RESULTS: Concentration values for samples of KRAS G12D and wild-type plasmid templates varied by <1.2-fold when measured using 5 different assays with varying detection chemistry (hydrolysis, scorpion probes, and intercalating dyes) and <1.3-fold with 4 commercial dPCR platforms. Measurement trueness of a selected dPCR assay and platform was validated by comparison with an orthogonal method (inductively coupled plasma mass spectrometry). The candidate dPCR reference measurement procedure showed linear quantification over a wide range of copies per reaction and high repeatability and interlaboratory reproducibility (CV, 2%-8% and 5%-10%, respectively). CONCLUSIONS: This work validates dPCR as an SI-traceable reference measurement procedure based on enumeration and demonstrates how it can be applied for assignment of copy number concentration and fractional abundance values to DNA reference materials in an aqueous solution. High-accuracy measurements using dPCR will support the implementation and traceable standardization of molecular diagnostic procedures needed for advancements in precision medicine.


Asunto(s)
Reacción en Cadena de la Polimerasa/métodos , Medicina de Precisión , Variaciones en el Número de Copia de ADN , Humanos , Espectrometría de Masas , Reproducibilidad de los Resultados
3.
Anal Chem ; 89(3): 1724-1733, 2017 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-27935690

RESUMEN

This study tested the claim that digital PCR (dPCR) can offer highly reproducible quantitative measurements in disparate laboratories. Twenty-one laboratories measured four blinded samples containing different quantities of a KRAS fragment encoding G12D, an important genetic marker for guiding therapy of certain cancers. This marker is challenging to quantify reproducibly using quantitative PCR (qPCR) or next generation sequencing (NGS) due to the presence of competing wild type sequences and the need for calibration. Using dPCR, 18 laboratories were able to quantify the G12D marker within 12% of each other in all samples. Three laboratories appeared to measure consistently outlying results; however, proper application of a follow-up analysis recommendation rectified their data. Our findings show that dPCR has demonstrable reproducibility across a large number of laboratories without calibration. This could enable the reproducible application of molecular stratification to guide therapy and, potentially, for molecular diagnostics.


Asunto(s)
Proteínas Proto-Oncogénicas p21(ras)/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , ADN/química , ADN/metabolismo , Humanos , Polimorfismo de Nucleótido Simple , Reproducibilidad de los Resultados , Análisis de Secuencia de ADN
4.
Anal Bioanal Chem ; 409(10): 2601-2614, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28124757

RESUMEN

Quantitative PCR (qPCR) is an important tool in pathogen detection. However, the use of different qPCR components, calibration materials and DNA extraction methods reduces comparability between laboratories, which can result in false diagnosis and discrepancies in patient care. The wider establishment of a metrological framework for nucleic acid tests could improve the degree of standardisation of pathogen detection and the quantification methods applied in the clinical context. To achieve this, accurate methods need to be developed and implemented as reference measurement procedures, and to facilitate characterisation of suitable certified reference materials. Digital PCR (dPCR) has already been used for pathogen quantification by analysing nucleic acids. Although dPCR has the potential to provide robust and accurate quantification of nucleic acids, further assessment of its actual performance characteristics is needed before it can be implemented in a metrological framework, and to allow adequate estimation of measurement uncertainties. Here, four laboratories demonstrated reproducibility (expanded measurement uncertainties below 15%) of dPCR for quantification of DNA from human cytomegalovirus, with no calibration to a common reference material. Using whole-virus material and extracted DNA, an intermediate precision (coefficients of variation below 25%) between three consecutive experiments was noted. Furthermore, discrepancies in estimated mean DNA copy number concentrations between laboratories were less than twofold, with DNA extraction as the main source of variability. These data demonstrate that dPCR offers a repeatable and reproducible method for quantification of viral DNA, and due to its satisfactory performance should be considered as candidate for reference methods for implementation in a metrological framework.


Asunto(s)
Infecciones por Citomegalovirus/diagnóstico , Citomegalovirus/genética , ADN Viral/análisis , Ensayos de Aptitud de Laboratorios/normas , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Citomegalovirus/aislamiento & purificación , Infecciones por Citomegalovirus/genética , Infecciones por Citomegalovirus/virología , ADN Viral/genética , Humanos , Reproducibilidad de los Resultados
6.
BMC Infect Dis ; 16: 366, 2016 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-27487852

RESUMEN

BACKGROUND: Real-time PCR (qPCR) based methods, such as the Xpert MTB/RIF, are increasingly being used to diagnose tuberculosis (TB). While qualitative methods are adequate for diagnosis, the therapeutic monitoring of TB patients requires quantitative methods currently performed using smear microscopy. The potential use of quantitative molecular measurements for therapeutic monitoring has been investigated but findings have been variable and inconclusive. The lack of an adequate reference method and reference materials is a barrier to understanding the source of such disagreement. Digital PCR (dPCR) offers the potential for an accurate method for quantification of specific DNA sequences in reference materials which can be used to evaluate quantitative molecular methods for TB treatment monitoring. METHODS: To assess a novel approach for the development of quality assurance materials we used dPCR to quantify specific DNA sequences in a range of prototype reference materials and evaluated accuracy between different laboratories and instruments. The materials were then also used to evaluate the quantitative performance of qPCR and Xpert MTB/RIF in eight clinical testing laboratories. RESULTS: dPCR was found to provide results in good agreement with the other methods tested and to be highly reproducible between laboratories without calibration even when using different instruments. When the reference materials were analysed with qPCR and Xpert MTB/RIF by clinical laboratories, all laboratories were able to correctly rank the reference materials according to concentration, however there was a marked difference in the measured magnitude. CONCLUSIONS: TB is a disease where the quantification of the pathogen could lead to better patient management and qPCR methods offer the potential to rapidly perform such analysis. However, our findings suggest that when precisely characterised materials are used to evaluate qPCR methods, the measurement result variation is too high to determine whether molecular quantification of Mycobacterium tuberculosis would provide a clinically useful readout. The methods described in this study provide a means by which the technical performance of quantitative molecular methods can be evaluated independently of clinical variability to improve accuracy of measurement results. These will assist in ultimately increasing the likelihood that such approaches could be used to improve patient management of TB.


Asunto(s)
ADN Bacteriano/aislamiento & purificación , Mycobacterium tuberculosis/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Tuberculosis Pulmonar/diagnóstico , Adulto , Femenino , Humanos , Masculino , Microscopía , Técnicas de Diagnóstico Molecular , Patología Molecular , Sensibilidad y Especificidad
7.
Anal Chem ; 87(7): 3706-13, 2015 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-25646934

RESUMEN

Digital PCR (dPCR) offers absolute quantification through the limiting dilution of template nucleic acid molecules and has the potential to offer high reproducibility. However, the robustness of dPCR has yet to be evaluated using complex genomes to compare different dPCR methods and platforms. We used DNA templates from the pathogen Mycobacterium tuberculosis to evaluate the impact of template type, master mixes, primer pairs and, crucially, extraction methods on dPCR performance. Performance was compared between the chip (BioMark) and droplet (QX100) formats. In the absence of any external calibration, dPCR measurements were generally consistent within ∼2-fold between different master mixes and primers. Template DNA integrity could influence dPCR performance: high molecular weight gDNA resulted in underperformance of one master mix, while restriction digestion of a low molecular weight sample also caused underestimation. Good concordance (≤1.5-fold difference) was observed between chip and droplet formats. Platform precision was in agreement with predicted Poisson error based on partition number, but this was a minor component (<10%) of the total variance when extraction was included. dPCR offers a robust reproducible method for DNA measurement; however, as a predominant source of error, the process of DNA extraction will need to be controlled with suitable calibrators to maximize agreement between laboratories.


Asunto(s)
ADN Bacteriano/análisis , Infecciones por Mycobacterium/microbiología , Mycobacterium bovis/genética , Mycobacterium tuberculosis/genética , Reacción en Cadena de la Polimerasa/métodos , Animales , ADN Bacteriano/genética , Humanos , Plásmidos/genética , Reproducibilidad de los Resultados
8.
J Clin Microbiol ; 53(7): 2008-14, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25392365

RESUMEN

Nucleic acid-based tests for infectious diseases currently used in the clinical laboratory and in point-of-care devices are diverse. Measurement challenges associated with standardization of quantitative viral load testing are discussed in relation to human cytomegalovirus, BK virus, and Epstein-Barr virus, while the importance of defining the performance of qualitative methods is illustrated with Mycobacterium tuberculosis and influenza virus. The development of certified reference materials whose values are traceable to higher-order standards and reference measurement procedures, using, for instance, digital PCR, will further contribute to the understanding of analytical performance characteristics and promote clinical data comparability.


Asunto(s)
Bacterias/aislamiento & purificación , Carga Bacteriana/normas , Técnicas de Diagnóstico Molecular/normas , Carga Viral/normas , Virus/aislamiento & purificación , Infecciones Bacterianas/microbiología , Carga Bacteriana/métodos , Humanos , Técnicas de Diagnóstico Molecular/métodos , Estándares de Referencia , Carga Viral/métodos , Virosis/virología
9.
BMC Genomics ; 15: 1174, 2014 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-25539843

RESUMEN

BACKGROUND: DNA methylation is an important epigenetic mechanism in several human diseases, most notably cancer. The quantitative analysis of DNA methylation patterns has the potential to serve as diagnostic and prognostic biomarkers, however, there is currently a lack of consensus regarding the optimal methodologies to quantify methylation status. To address this issue we compared five analytical methods: (i) MethyLight qPCR, (ii) MethyLight digital PCR (dPCR), methylation-sensitive and -dependent restriction enzyme (MSRE/MDRE) digestion followed by (iii) qPCR or (iv) dPCR, and (v) bisulfite amplicon next generation sequencing (NGS). The techniques were evaluated for linearity, accuracy and precision. RESULTS: MethyLight qPCR displayed the best linearity across the range of tested samples. Observed methylation measured by MethyLight- and MSRE/MDRE-qPCR and -dPCR were not significantly different to expected values whilst bisulfite amplicon NGS analysis over-estimated methylation content. Bisulfite amplicon NGS showed good precision, whilst the lower precision of qPCR and dPCR analysis precluded discrimination of differences of < 25% in methylation status. A novel dPCR MethyLight assay is also described as a potential method for absolute quantification that simultaneously measures both sense and antisense DNA strands following bisulfite treatment. CONCLUSIONS: Our findings comprise a comprehensive benchmark for the quantitative accuracy of key methods for methylation analysis and demonstrate their applicability to the quantification of circulating tumour DNA biomarkers by using sample concentrations that are representative of typical clinical isolates.


Asunto(s)
Metilación de ADN , Epigenómica/métodos , Marcadores Genéticos/genética , Enzimas de Restricción del ADN/metabolismo , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Reacción en Cadena de la Polimerasa , Análisis de Secuencia de ADN , Sulfitos/farmacología
10.
Anal Biochem ; 452: 103-13, 2014 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-24631519

RESUMEN

High-throughput quantitative polymerase chain reaction (qPCR) approaches enable profiling of multiple genes in single cells, bringing new insights to complex biological processes and offering opportunities for single cell-based monitoring of cancer cells and stem cell-based therapies. However, workflows with well-defined sources of variation are required for clinical diagnostics and testing of tissue-engineered products. In a study of neural stem cell lines, we investigated the performance of lysis, reverse transcription (RT), preamplification (PA), and nanofluidic qPCR steps at the single cell level in terms of efficiency, precision, and limit of detection. We compared protocols using a separate lysis buffer with cell capture directly in RT-PA reagent. The two methods were found to have similar lysis efficiencies, whereas the direct RT-PA approach showed improved precision. Digital PCR was used to relate preamplified template copy numbers to Cq values and reveal where low-quality signals may affect the analysis. We investigated the impact of calibration and data normalization strategies as a means of minimizing the impact of inter-experimental variation on gene expression values and found that both approaches can improve data comparability. This study provides validation and guidance for the application of high-throughput qPCR workflows for gene expression profiling of single cells.


Asunto(s)
Reacción en Cadena de la Polimerasa/métodos , Análisis de la Célula Individual/métodos , Calibración , Línea Celular , Límite de Detección , Nanotecnología , ARN Mensajero/genética , Transcripción Reversa
11.
Methods ; 59(1): 89-100, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22841564

RESUMEN

Recent years have seen the emergence of new high-throughput PCR and sequencing platforms with the potential to bring analysis of transcriptional biomarkers to a broader range of clinical applications and to provide increasing depth to our understanding of the transcriptome. We present an overview of how to process clinical samples for RNA biomarker analysis in terms of RNA extraction and mRNA enrichment, and guidelines for sample analysis by RT-qPCR and digital PCR using nanofluidic real-time PCR platforms. The options for quantitative gene expression profiling and whole transcriptome sequencing by next generation sequencing are reviewed alongside the bioinformatic considerations for these approaches. Considering the diverse technologies now available for transcriptome analysis, methods for standardising measurements between platforms will be paramount if their diagnostic impact is to be maximised. Therefore, the use of RNA standards and other reference materials is also discussed.


Asunto(s)
Secuenciación de Nucleótidos de Alto Rendimiento/normas , ARN Mensajero/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/normas , Animales , Biomarcadores/metabolismo , División del ADN , Biblioteca de Genes , Humanos , Técnicas Analíticas Microfluídicas , ARN Mensajero/aislamiento & purificación , ARN Mensajero/metabolismo , Estándares de Referencia
12.
Anal Bioanal Chem ; 406(26): 6499-512, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24853859

RESUMEN

Circulating cell-free DNA (cfDNA) is becoming an important clinical analyte for prenatal testing, cancer diagnosis and cancer monitoring. The extraction stage is critical in ensuring clinical sensitivity of analytical methods measuring minority nucleic acid fractions, such as foetal-derived sequences in predominantly maternal cfDNA. Consequently, quality controls are required for measurement of extraction efficiency, fragment size bias and yield for validation of cfDNA methods. We evaluated the utility of an external DNA spike for monitoring these parameters in a study comparing three specific cfDNA extraction methods [QIAamp circulating nucleic acid (CNA) kit, NucleoSpin Plasma XS (NS) kit and FitAmp plasma/serum DNA isolation (FA) kit] with the commonly used QIAamp DNA blood mini (DBM) kit. We found that the extraction efficiencies of the kits ranked in the order CNA kit > DBM kit > NS kit > FA kit, and the CNA and NS kits gave a better representation of smaller DNA fragments in the extract than the DBM kit. We investigated means of improved reporting of cfDNA yield by comparing quantitative PCR measurements of seven different reference gene assays in plasma samples and validating these with digital PCR. We noted that the cfDNA quantities based on measurement of some target genes (e.g. TERT) were, on average, more than twofold higher than those of other assays (e.g. ERV3). We conclude that analysis and averaging of multiple reference genes using a GeNorm approach gives a more reliable estimate of total cfDNA quantity.


Asunto(s)
ADN/sangre , ADN/aislamiento & purificación , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Femenino , Humanos , Persona de Mediana Edad , Juego de Reactivos para Diagnóstico/normas , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Estándares de Referencia , Reproducibilidad de los Resultados
13.
N Biotechnol ; 78: 13-21, 2023 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-37730172

RESUMEN

Analysis of circulating cell-free DNA (ccfDNA) isolated from liquid biopsies is rapidly being implemented into clinical practice. However, diagnostic accuracy is significantly impacted by sample quality and standardised approaches for assessing the quality of ccfDNA are not yet established. In this study we evaluated the application of nucleic acid "spike-in" control materials to aid quality control (QC) and standardisation of cfDNA isolation for use in in vitro diagnostic assays. We describe an approach for the design and characterisation of in-process QC materials, illustrating it with a spike-in material containing an exogenous Arabidopsis sequence and DNA fragments approximating to ccfDNA and genomic DNA lengths. Protocols for inclusion of the spike-in material in plasma ccfDNA extraction and quantification of its recovery by digital PCR (dPCR) were assessed for their suitability for process QC in an inter-laboratory study between five expert laboratories, using a range of blood collection devices and ccfDNA extraction methods. The results successfully demonstrated that spiking plasmid-derived material into plasma did not deleteriously interfere with endogenous ccfDNA recovery. The approach performed consistently across a range of commonly-used extraction protocols and was able to highlight differences in efficiency and variability between the methods, with the dPCR quantification assay performing with good repeatability (generally CV <5%). We conclude that initial findings demonstrate that this approach appears "fit for purpose" and spike-in recovery can be combined with other extraction QC metrics for monitoring the performance of a process over time, or in the context of external quality assessment.


Asunto(s)
Ácidos Nucleicos Libres de Células , Ácidos Nucleicos Libres de Células/análisis , Biopsia Líquida/métodos , Control de Calidad , ADN , Reacción en Cadena de la Polimerasa/métodos
14.
Anal Biochem ; 427(2): 178-86, 2012 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-22617801

RESUMEN

Single cell gene expression analysis can provide insights into development and disease progression by profiling individual cellular responses as opposed to reporting the global average of a population. Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) is the "gold standard" for the quantification of gene expression levels; however, the technical performance of kits and platforms aimed at single cell analysis has not been fully defined in terms of sensitivity and assay comparability. We compared three kits using purification columns (PicoPure) or direct lysis (CellsDirect and Cells-to-CT) combined with a one- or two-step RT-qPCR approach using dilutions of cells and RNA standards to the single cell level. Single cell-level messenger RNA (mRNA) analysis was possible using all three methods, although the precision, linearity, and effect of lysis buffer and cell background differed depending on the approach used. The impact of using a microfluidic qPCR platform versus a standard instrument was investigated for potential variability introduced by preamplification of template or scaling down of the qPCR to nanoliter volumes using laser-dissected single cell samples. The two approaches were found to be comparable. These studies show that accurate gene expression analysis is achievable at the single cell level and highlight the importance of well-validated experimental procedures for low-level mRNA analysis.


Asunto(s)
ARN Mensajero/análisis , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Transcripción Reversa , Análisis de la Célula Individual/métodos , Extractos Celulares/química , Fibroblastos/citología , Fibroblastos/metabolismo , Perfilación de la Expresión Génica , Humanos , Masculino , Técnicas Analíticas Microfluídicas , ARN Mensajero/biosíntesis , Estándares de Referencia , Análisis de Regresión , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/instrumentación
15.
N Biotechnol ; 72: 97-106, 2022 Dec 25.
Artículo en Inglés | MEDLINE | ID: mdl-36202346

RESUMEN

Cerebrospinal fluid (CSF) is a source of diagnostic biomarkers for a range of neurological conditions. Cell-free DNA (cfDNA) is detected in CSF and differences in the concentration of cell-free mitochondrial DNA have been reported in studies of neurodegenerative disorders including Alzheimer's disease (AD). However, the influence of pre-analytical steps has not been investigated for cfDNA in CSF and there is no standardised approach for quantification of total cfDNA (copies of nuclear genome or mitochondria-derived gene targets). In this study, the suitability of four extraction methods was evaluated: QIAamp Circulating Nucleic Acid (Qiagen), Quick-cfDNA Serum & Plasma (Zymo), NucleoSnap® DNA Plasma (Macherey-Nagel) and Plasma/Serum Circulating DNA Purification Mini (Norgen) kits, for cfDNA extraction from CSF of controls and AD dementia patients, utilising a spike-in control for extraction efficiency and fragment size. One of the optimal extraction methods was applied to a comparison of cfDNA concentrations in CSF from control subjects, AD dementia and primary and secondary brain tumour patients. Extraction efficiency based on spike-in recovery was similar in all three groups whilst both endogenous mitochondrial and nucleus-derived cfDNA was significantly higher in CSF from cancer patients compared to control and AD groups, which typically contained < 100 genome copies/mL. This study shows that it is feasible to measure low concentration nuclear and mitochondrial gene targets in CSF and that normalisation of extraction yield can help control pre-analytical variability influencing biomarker measurements.


Asunto(s)
Enfermedad de Alzheimer , Neoplasias Encefálicas , Ácidos Nucleicos Libres de Células , Humanos , Enfermedad de Alzheimer/diagnóstico , Biomarcadores
16.
BMC Genomics ; 12: 118, 2011 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-21332979

RESUMEN

The availability of diverse RT-qPCR assay formats and technologies hinder comparability of data between platforms. Reference standards to facilitate platform evaluation and comparability are needed. We have explored using universal RNA standards for comparing the performance of a novel qPCR platform (Fluidigm® BioMark™) against the widely used ABI 7900HT system. Our results show that such standards may form part of a toolkit to evaluate the key performance characteristics of platforms.


Asunto(s)
ARN/análisis , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/métodos , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa/normas , Límite de Detección , Estándares de Referencia
17.
BMC Genomics ; 11: 662, 2010 Nov 24.
Artículo en Inglés | MEDLINE | ID: mdl-21106083

RESUMEN

BACKGROUND: Gene expression profiling is an important approach for detecting diagnostic and prognostic biomarkers, and predicting drug safety. The development of a wide range of technologies and platforms for measuring mRNA expression makes the evaluation and standardization of transcriptomic data problematic due to differences in protocols, data processing and analysis methods. Thus, universal RNA standards, such as those developed by the External RNA Controls Consortium (ERCC), are proposed to aid validation of research findings from diverse platforms such as microarrays and RT-qPCR, and play a role in quality control (QC) processes as transcriptomic profiling becomes more commonplace in the clinical setting. RESULTS: Panels of ERCC RNA standards were constructed in order to test the utility of these reference materials (RMs) for performance characterization of two selected gene expression platforms, and for discrimination of biomarker profiles between groups. The linear range, limits of detection and reproducibility of microarray and RT-qPCR measurements were evaluated using panels of RNA standards. Transcripts of low abundance (≤ 10 copies/ng total RNA) showed more than double the technical variability compared to higher copy number transcripts on both platforms. Microarray profiling of two simulated 'normal' and 'disease' panels, each consisting of eight different RNA standards, yielded robust discrimination between the panels and between standards with varying fold change ratios, showing no systematic effects due to different labelling and hybridization runs. Also, comparison of microarray and RT-qPCR data for fold changes showed agreement for the two platforms. CONCLUSIONS: ERCC RNA standards provide a generic means of evaluating different aspects of platform performance, and can provide information on the technical variation associated with quantification of biomarkers expressed at different levels of physiological abundance. Distinct panels of standards serve as an ideal quality control tool kit for determining the accuracy of fold change cut-off threshold and the impact of experimentally-derived noise on the discrimination of normal and disease profiles.


Asunto(s)
Biomarcadores/análisis , Perfilación de la Expresión Génica/métodos , Perfilación de la Expresión Génica/normas , ARN/normas , Secuencia de Bases , Enfermedad/genética , Humanos , Límite de Detección , Análisis de Secuencia por Matrices de Oligonucleótidos , Estándares de Referencia , Reproducibilidad de los Resultados , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa
19.
Methods Mol Biol ; 1768: 45-65, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29717437

RESUMEN

Cell-free DNA is an accessible source of genetic material found naturally in plasma that could be used in many diagnostic applications. Translation of cfDNA analysis methods from research laboratories into the clinic would benefit from controls for monitoring the efficiency of patient sample purification and for quality control of the whole workflow from extraction through to analysis. Here we describe two types of control materials that can be "spiked" into plasma samples to monitor and evaluate different aspects of the workflow. The first control material is an internal control that enables evaluation of extraction efficiency, fragment size bias, and sample inhibition. The second control material serves as a parallel quality control material for measurement of specific genetic targets such as tumor mutations.


Asunto(s)
Ácidos Nucleicos Libres de Células/aislamiento & purificación , Reacción en Cadena de la Polimerasa/métodos , Calibración/normas , Ácidos Nucleicos Libres de Células/sangre , Humanos , Reacción en Cadena de la Polimerasa/instrumentación , Reacción en Cadena de la Polimerasa/normas , Estándares de Referencia
20.
PLoS One ; 13(3): e0194630, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29547634

RESUMEN

INTRODUCTION: Detection and monitoring of circulating tumor DNA (ctDNA) is rapidly becoming a diagnostic, prognostic and predictive tool in cancer patient care. A growing number of gene targets have been identified as diagnostic or actionable, requiring the development of reliable technology that provides analysis of multiple genes in parallel. We have developed the InVision™ liquid biopsy platform which utilizes enhanced TAm-Seq™ (eTAm-Seq™) technology, an amplicon-based next generation sequencing method for the identification of clinically-relevant somatic alterations at low frequency in ctDNA across a panel of 35 cancer-related genes. MATERIALS AND METHODS: We present analytical validation of the eTAm-Seq technology across two laboratories to determine the reproducibility of mutation identification. We assess the quantitative performance of eTAm-Seq technology for analysis of single nucleotide variants in clinically-relevant genes as compared to digital PCR (dPCR), using both established DNA standards and novel full-process control material. RESULTS: The assay detected mutant alleles down to 0.02% AF, with high per-base specificity of 99.9997%. Across two laboratories, analysis of samples with optimal amount of DNA detected 94% mutations at 0.25%-0.33% allele fraction (AF), with 90% of mutations detected for samples with lower amounts of input DNA. CONCLUSIONS: These studies demonstrate that eTAm-Seq technology is a robust and reproducible technology for the identification and quantification of somatic mutations in circulating tumor DNA, and support its use in clinical applications for precision medicine.


Asunto(s)
Biomarcadores de Tumor/análisis , Ácidos Nucleicos Libres de Células/análisis , Análisis Mutacional de ADN/métodos , Mutación , Neoplasias/diagnóstico , Células Neoplásicas Circulantes/patología , Adulto , Alelos , Biomarcadores de Tumor/genética , ADN Tumoral Circulante/análisis , ADN de Neoplasias/genética , Femenino , Secuenciación de Nucleótidos de Alto Rendimiento/métodos , Humanos , Biopsia Líquida/métodos , Masculino , Células Neoplásicas Circulantes/química , Reacción en Cadena de la Polimerasa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA