Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Pharm Bioallied Sci ; 16(Suppl 1): S254-S257, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595510

RESUMEN

Background: Maxillary molar endodontic treatments require the right post and core system. This study tested cast metal, glass fiber with composite resin, carbon fiber with composite resin, and zirconia post and core materials. Materials and Methods: Sixty removed human maxillary teeth were randomly divided into four post and core material groups (n = 15 per group). The teeth acquired their post and core system after normal endodontic treatment. Fracture resistance, cyclic fatigue resistance, and microleakage analyses were statistically assessed. Results: The zirconia post and core material had the highest fracture resistance (mean: 900 N), followed by carbon fiber with composite resin, cast metal, and glass fiber with composite resin. Zirconia had the highest mean cycles to failure (120,000), followed by carbon fiber with composite resin (100,000), cast metal (110,000), and glass fiber with composite resin (90,000). Zirconia had the lowest mean microleakage score (1.8), and glass fiber with composite resin, the highest (3.0). Conclusion: The zirconia post and core material outperformed the others in fracture resistance, cyclic fatigue resistance, and sealing. The cast metal has better fracture and cycle fatigue resistance than glass fiber with composite resin. These findings help doctors choose maxillary molar endodontic post and core materials.

2.
J Pharm Bioallied Sci ; 16(Suppl 1): S174-S176, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595539

RESUMEN

Introduction: Polyetheretherketone (PEEK) has a long history of usage in implant abutments, but it has not seen much applications in tooth-supported prosthetics. The purpose of this research was to examine the clinical performance of PEEK crowns as well as the level of patient satisfaction with them. The pilot study was designed as an in vivo longitudinal examination. Material and Methods: Twenty patients each received a PEEK crown during the procedure. In total, 22 implants were inserted, with 11 going into the maxilla and 9 into the mandible. One operator was responsible for carrying out each phase of the procedure. The resin cement was used to lute the crowns that were produced. Baseline, 3 months, 6 months, and 1 year after the crowns were placed, they were evaluated for various parameters using Modified Ryge's Criteria. These evaluations were performed at intervals of 3 months, 6 months, and 1 year. In addition, a questionnaire was used at the same time to assess the level of satisfaction felt by patients. Fisher's exact test was utilized in the process of analyzing the data that were gathered. Results: According to the findings, 92.5% of the crowns met the modified version of Ryge's criterion for a satisfactory rating. Three crowns had a fracture recorded. There was some chipping off observed in five of the crowns. There was not any significant difference in the other factors that were examined. The periodontal health of these three patients showed a slight degree of variance (P = 0.02). Conclusion: The capacity of PEEK crowns to create high-quality prostheses that were deemed satisfactory with a reasonably low rate of fracture during the relative mean duration of 1 year was established by the application of Modified Ryge's Criteria. The PEEK crowns demonstrated their ability to produce quality prostheses.

3.
J Pharm Bioallied Sci ; 16(Suppl 1): S171-S173, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595552

RESUMEN

Introduction: Many adjuvant methods have been researched to enhance the immediate implant success in the recent times. The study's goal was to compare the aesthetic and biological results of immediate dental implants in the aesthetic zone to standard tapered root form implants that had not undergone pre-treatment with platelet-rich plasma or photofunctionalization. Materials and Methods: The study used a randomized controlled trial as its design. Ninety subjects were chosen at random and placed into three groups: a control group, a case group, and a group that needed replacement of their maxillary anterior teeth right away following extraction. The interventional groups received the "Platelet-Rich Plasma (PRP)" or "Photofunctionalization (PF)" group before the implant placement. After the delayed loading approach, the prosthesis was given after 6 months. At the second and fourth weeks, as well as 2, 4, 6, and 12 months (P 0.05), follow-up was conducted. The success and survival rate, aesthetic, and biological outcomes were assessed. One-way ANOVA was used to compare outcomes, and repeated-measures ANOVA was used to assess intragroup variations over baseline and follow-up. Results: The distal, mesial, and mean marginal bone loss as well as the aesthetic scores for pink and white did not differ significantly between groups. The implant stability however was significantly higher in the PF and PRP groups as compared to the controls. A single implant failed in all the three groups. The success percentage was similar for all the groups. Conclusion: The stability of immediate dental implants pre-treated with PRP or PF differed statistically significantly than the subjects in the control group, while other parameters remained the similar between the groups.

4.
J Pharm Bioallied Sci ; 16(Suppl 1): S177-S179, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595557

RESUMEN

Introduction: Surface roughness of the crowns is dependent on the pattern material used for the making as well as the procedure of investing. The study was aimed to examine the impact of various pattern materials and investment procedures on the surface roughness of nickel-chromium alloy raw castings. Materials and Methods: An in-vitro study was piloted at a tertiary care hospital. Eighty samples of inlay wax and pattern resin were divided equally. They were invested in phosphate-bonded investment material and kept under normal atmospheric pressure as well as invested under a pressure of 3 bars. The surface roughness was calculated with a Profilometer. The values obtained were compared using statistical tools keeping P < 0.05 as significant. Results: Lowest surface roughness was seen for the wax pattern invested under positive pressure. While the highest was seen for the resin patterns invested at room pressure. A significant variance between the wax 1 and wax 2 (P < 0.01); as well as between the wax 2 vs. Resin 2 specimens (P < 0.01) was noted. Conclusions: Wax patterns can be suggested as the material and method of choice because they showed the least amount of surface roughness when placed under pressure. Resin patterns when invested under pressure can also be suggested as an alternate as they also exhibited similar surface roughness as that of the wax.

5.
J Pharm Bioallied Sci ; 16(Suppl 1): S268-S271, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38595511

RESUMEN

Objective: This study's goal was to assess the failure rate and peri-implant complications of single-piece implant systems over the course of a one-year follow-up. Materials and Methods: Patient records were examined retrospectively. 150 single-piece dental implants were analyzed. Clinical results, implant features, and demographic information were gathered. Implant failure, which is characterized as the total loss of osseointegration, served as the key outcome indicator. Patient satisfaction and peri-implant problems were secondary outcomes. Data analysis employed descriptive statistics. Results: During the one-year follow-up period, the failure rate for single-piece implant systems was 6.7%. The two main factors leading to implant failure were found to be poor osseointegration (60%) and biomechanical overload (40%). 20% of the cases had peri-implant problems, such as peri-implantitis. 85% of the panelists felt that single-piece implants had satisfied their patients. Conclusion: A 6.7% failure rate in single-piece implant systems was seen in this one-year follow-up investigation. The major causes of implant failure were found to be poor osseointegration and biomechanical loading. In 20% of the cases, peri-implant problems such as peri-implantitis, were noted. There was great patient satisfaction. These results highlight the significance of regulating occlusal forces, optimizing osseointegration, and applying preventive measures to ensure the long-term viability of single-piece implant systems.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA