Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 622
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38751010

RESUMEN

INTRODUCTION: Both atrial fibrillation (AF) and amyloidosis increase stroke risk. We evaluated the best anticoagulation strategy in AF patients with coexistent amyloidosis. METHODS: Consecutive AF patients with concomitant amyloidosis were divided into two groups based on the postablation stroke-prophylaxis approach; group 1: left atrial appendage occlusion (LAAO) in eligible patients and group 2: oral anticoagulation (OAC). Group 1 patients were further divided into Gr. 1A: LAAO + half-does NOAC (HD-NOAC) for 6 months followed by aspirin 81 mg/day and Gr. 1B: LAAO + HD-NOAC. In group 1 patients, with complete occlusion at the 45-day transesophageal echocardiogram, patients were switched to aspirin, 81 mg/day at 6 months. In case of leak, or dense "smoke" in the left atrium (LA) or enlarged LA, they were placed on long-term half-dose (HD) NOAC. Group 2 patients remained on full-dose NOAC during the whole study period. RESULTS: A total of 92 patients were included in the analysis; group 1: 56 and group 2: 36. After the 45-day TEE, 31 patients from group 1 remained on baby-aspirin and 25 on HD NOAC. At 1-year follow-up, four stroke, one TIA and six device-thrombus were reported in group 1A, compared to none in patients in group 1B (5/31 vs. 0/25, p = .03). No bleeding events were reported in group 1, whereas group 2 had five bleeding events (one subdural hematoma, one retinal hemorrhage, and four GI bleedings). Additionally, one stroke was reported in group 2 that happened during brief discontinuation of OAC. CONCLUSION: In patients with coexistent AF and amyloidosis, half-dose NOAC following LAAO was observed to be the safest stroke-prophylaxis strategy.

2.
Europace ; 26(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38266130

RESUMEN

AIMS: Different disease processes can combine to cause atrial fibrillation (AF). Their contribution to recurrent AF after ablation in patients is not known. Cardiovascular processes associated with recurrent AF after AF ablation were determined by quantifying biomolecules related to inflammation, metabolism, proliferation, fibrosis, shear stress, atrial pressure, and others in the AXAFA biomolecule study. METHODS AND RESULTS: Twelve circulating cardiovascular biomolecules (ANGPT2, BMP10, CA125, hsCRP, ESM1, FABP3, FGF23, GDF15, IGFBP7, IL6, NT-proBNP, and hsTnT) were quantified in plasma samples obtained prior to a first AF ablation using high-throughput, high-precision assays. Cox regression was used to identify biomolecules associated with recurrent AF during the first 3 months after AF ablation. In 433 patients (64 years [58, 70]; 33% women), baseline concentrations of ANGPT2, BMP10, hsCRP, FGF23, FABP3, GDF15, and NT-proBNP were elevated in patients with recurrent AF (120/433; 28%). After adjustment for 11 clinical features and randomized treatment, elevated NT-proBNP [hazard ratio (HR) 1.58, 95% confidence interval (1.29, 1.94)], ANGPT2 [HR 1.37, (1.12, 1.67)], and BMP10 [HR 1.24 (1.02, 1.51)] remained associated with recurrent AF. Concentrations of ANGPT2, BMP10, and NT-proBNP decreased in patients who remained arrhythmia free, but not in patients with recurrent AF, highlighting their connection to AF. The other eight biomarkers showed unchanged concentrations. CONCLUSION: Elevated concentrations of ANGPT2, BMP10, and NT-proBNP are associated with recurrent AF after a first AF ablation, suggesting that processes linked to disturbed cardiomyocyte metabolism, altered atrial shear stress, and increased load contribute to AF after AF ablation in patients.


Asunto(s)
Fibrilación Atrial , Humanos , Femenino , Masculino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Proteína C-Reactiva , Atrios Cardíacos , Péptido Natriurético Encefálico , Biomarcadores , Modelos de Riesgos Proporcionales , Fragmentos de Péptidos , Proteínas Morfogenéticas Óseas
3.
Europace ; 26(5)2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38696701

RESUMEN

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica , Puntaje de Propensión , Sistema de Registros , Humanos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Factores Sexuales , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Factores de Riesgo , Resultado del Tratamiento , Arritmias Cardíacas/terapia , Medición de Riesgo , Europa (Continente) , Factores de Tiempo , Muerte Súbita Cardíaca/prevención & control
4.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584394

RESUMEN

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Asunto(s)
Ablación por Catéter , Desfibriladores Implantables , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Cardioversión Eléctrica/efectos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
5.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38584423

RESUMEN

Electrical storm (ES) is a state of electrical instability, manifesting as recurrent ventricular arrhythmias (VAs) over a short period of time (three or more episodes of sustained VA within 24 h, separated by at least 5 min, requiring termination by an intervention). The clinical presentation can vary, but ES is usually a cardiac emergency. Electrical storm mainly affects patients with structural or primary electrical heart disease, often with an implantable cardioverter-defibrillator (ICD). Management of ES requires a multi-faceted approach and the involvement of multi-disciplinary teams, but despite advanced treatment and often invasive procedures, it is associated with high morbidity and mortality. With an ageing population, longer survival of heart failure patients, and an increasing number of patients with ICD, the incidence of ES is expected to increase. This European Heart Rhythm Association clinical consensus statement focuses on pathophysiology, clinical presentation, diagnostic evaluation, and acute and long-term management of patients presenting with ES or clustered VA.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Taquicardia Ventricular , Humanos , Factores de Riesgo , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Incidencia , Insuficiencia Cardíaca/complicaciones , Asia/epidemiología , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicaciones
6.
Europace ; 26(4)2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38587017

RESUMEN

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , América Latina , Resultado del Tratamiento , Catéteres , Asia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
7.
Pacing Clin Electrophysiol ; 47(2): 185-194, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38010836

RESUMEN

BACKGROUND: Despite its clinical benefits, patient compliance to remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) varies and remains under-studied in diverse populations. OBJECTIVE: We sought to evaluate RM compliance, clinical outcomes, and identify demographic and socioeconomic factors affecting RM in a diverse urban population in New York. METHODS: This retrospective cohort study included patients enrolled in CIED RM at Montefiore Medical Center between December 2017 and May 2022. RM compliance was defined as the percentage of days compliant to RM transmission divided by the total prescribed days of RM. Patients were censored when they were lost to follow-up or at the time of death. The cohorts were categorized into low (≤30%), intermediate (31-69%), and high (≥70%) RM compliance groups. Statistical analyses were conducted accordingly. RESULTS: Among 853 patients, median RM compliance was 55%. Age inversely affected compliance (p < .001), and high compliance was associated with guideline-directed medical therapy (GDMT) usage and implantable cardioverter defibrillator (ICD)/cardiac resynchronization defibrillator (CRTD) devices. The low-compliance group had a higher mortality rate and fewer regular clinic visits (p < .001) than high-compliance group. Socioeconomic factors did not significantly impact compliance, while Asians showed higher compliance compared with Whites (OR 3.67; 95% CI 1.08-12.43; p = .04). Technical issues were the main reason for non-compliance. CONCLUSION: We observed suboptimal compliance to RM, which occurred most frequently in older patients. Clinic visit compliance, optimal medical therapy, and lower mortality were associated with higher compliance, whereas insufficient understanding of RM usage was the chief barrier to compliance.


Asunto(s)
Desfibriladores Implantables , Tecnología de Sensores Remotos , Humanos , Anciano , Estudios Retrospectivos , Dispositivos de Terapia de Resincronización Cardíaca , Demografía
8.
Circulation ; 145(12): 906-915, 2022 03 22.
Artículo en Inglés | MEDLINE | ID: mdl-35135308

RESUMEN

BACKGROUND: We aimed to assess the prevalence of ischemic brain lesions detected by magnetic resonance imaging and their association with cognitive function 3 months after first-time ablation using continuous oral anticoagulation in patients with paroxysmal atrial fibrillation (AF). METHODS: We performed a prespecified analysis of the AXAFA-AFNET 5 trial (Anticoagulation Using the Direct Factor Xa Inhibitor Apixaban During Atrial Fibrillation Catheter Ablation: Comparison to Vitamin K Antagonist Therapy), which randomized 674 patients with AF 1:1 to uninterrupted apixaban or vitamin K antagonist therapy before first-time ablation. Brain magnetic resonance imaging using fluid-attenuated inversion recovery and high-resolution diffusion-weighted imaging was obtained within 3 to 48 hours after AF ablation in all eligible patients enrolled in 25 study centers in Europe and the United States. Patients underwent cognitive assessment 3 to 6 weeks before ablation and 3 months after ablation using the Montreal Cognitive Assessment (MoCA). RESULTS: In 84 (26.1%) of 321 patients with analyzable magnetic resonance imaging, high-resolution diffusion-weighted imaging detected at least 1 acute brain lesion, including 44 (27.2%) patients treated with apixaban and 40 (24.8%) patients treated with vitamin K antagonist (P=0.675). Median MoCA score was similar in patients with or without acute brain lesions at 3 months after ablation (28 [interquartile range (IQR), 26-29] versus 28 [IQR, 26-29]; P=0.948). Cerebral chronic white matter damage (defined as Wahlund score ≥4 points) detected by fluid-attenuated inversion recovery was present in 130 (40.5%) patients and associated with lower median MoCA scores before ablation (27 [IQR, 24-28] versus 27 [IQR, 25-29]; P=0.026) and 3 months after ablation (27 [IQR, 25-29] versus 28 [IQR, 26-29]; P=0.011). This association was no longer significant when adjusted for age and sex. Age was associated with lower MoCA scores before ablation (relative risk, 1.02 per 10 years [95% CI, 1.01-1.03]) and 3 months after ablation (relative risk, 1.02 per 10 years [95% CI, 1.01-1.03]). CONCLUSIONS: Chronic white matter damage as well as acute ischemic lesions detected by brain magnetic resonance imaging were found frequently after first-time ablation for paroxysmal AF using uninterrupted oral anticoagulation. Acute ischemic brain lesions detected by high-resolution diffusion-weighted imaging were not associated with cognitive function at 3 months after ablation. Lower MoCA scores before and after ablation were associated only with older age, highlighting the safety of AF ablation on uninterrupted oral anticoagulation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02227550.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anticoagulantes/uso terapéutico , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/cirugía , Encéfalo/diagnóstico por imagen , Ablación por Catéter/efectos adversos , Cognición , Humanos , Imagen por Resonancia Magnética , Resultado del Tratamiento , Vitamina K
9.
J Cardiovasc Electrophysiol ; 34(12): 2621-2625, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37987539

RESUMEN

INTRODUCTION: Catheter ablation of atrial fibrillation (AF) has emerged as the most effective therapy. However, rare anatomical abnormalities such as situs inversus totalis, dextrocardia, or interrupted inferior vena cava can make ablation challenging. METHODS AND RESULTS: We report a case of a 55-year-old woman with situs inversus totalis, dextrocardia, surgical atrial septal defect repair, left-sided dual chamber pacemaker in place, and symptomatic recurrent persistent AF who underwent successful pulmonary vein and posterior wall isolation by the superior access from the left internal jugular vein. CONCLUSIONS: It is a feasible and safe approach with support of transesophageal echocardiography and multiple emerging technologies.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Dextrocardia , Cardiopatías Congénitas , Situs Inversus , Femenino , Humanos , Persona de Mediana Edad , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/diagnóstico por imagen , Situs Inversus/complicaciones , Situs Inversus/diagnóstico por imagen , Situs Inversus/cirugía , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/cirugía , Dextrocardia/complicaciones , Dextrocardia/diagnóstico por imagen , Cardiopatías Congénitas/cirugía
10.
J Cardiovasc Electrophysiol ; 34(2): 327-334, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36511480

RESUMEN

INTRODUCTION: Electrical isolation of pulmonary veins (PVI) is a cornerstone for atrial fibrillation (AF) ablation. The overall effect of AF ablation, and especially lesions beyond PVI, on left atrial (LA) function is currently poorly understood. Our aim was to determine if LA function is different in patients after extensive LA ablation compared to PVI only. We performed non-inferiority analysis of LA function after PVI with additional nonpulmonary vein ablation lesions in LA (PVI+) and PVI alone. METHODS: We studied 68 patients consecutive patients who underwent AF ablation and who had complete transthoracic echocardiogram (TTE) within 12 months before AF ablation and 1-12 months after the procedure. Patients were stratified into two groups: PVI only and PVI+. Primary outcome was change in LA reservoir strain (LASr). Noninferiority margin was defined at 6%. RESULTS: The PVI only group had a higher proportion of patients with paroxysmal AF (70% vs. 30%). The PVI+ group was observed to have a slightly higher increase in LASr compared to PVI alone (5.0% vs. 4.3%, p < .01 for noninferiority). LASr noninferiority was confirmed when adjusted for age, sex, coronary artery disease, hyperlipidemia, and AF type, rhythm at preprocedure TTE in a multivariable linear regression model, 90% CI (-5.46 to 2.04), p < .01. CONCLUSION: LA functional improvement evaluated by LASr was noninferior after PVI with additional LA ablation lesions compared to PVI alone. These findings were confirmed when adjusted for confounding clinical variables, suggesting that more extensive ablation does not negatively affect LA function.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Función del Atrio Izquierdo , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Recurrencia
11.
J Cardiovasc Electrophysiol ; 34(4): 1024-1032, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36786513

RESUMEN

INTRODUCTION: Capsulectomy is recommended in patients with cardiac implantable electronic device (CIED) infection after transvenous lead extraction (TLE) but is time-consuming and requires extensive tissue debridement. In this study, we describe the outcomes of chlorhexidine gluconate (CHG) lavage in lieu of capsulectomy for the treatment of CIED infections. METHODS: This retrospective study included patients who underwent TLE for CIED-related infections in two institutions in Colombia. In the capsulectomy group, complete capsulectomy was performed after hardware removal. In the CHG group, exhaustive lavage of the generator pocket with 20 cc of CHG at 2% followed by irrigation with approximately 500 cc of normal saline (0.9% sodium chloride) was performed. The primary outcomes included reinfection and hematoma formation in the generator pocket. Secondary outcomes included the occurrence of any adverse reaction to chlorhexidine, the need for reintervention, infection-related mortality, and total procedural time. RESULTS: A total of 102 patients (mean age 67.2 ± 13 years, 32.4% female) underwent CIED extraction with either total capsulectomy (n = 54) or CHG (n = 48) lavage. Hematoma formation was significantly higher in the capsulectomy group versus the CHG group (13% vs. 0%, p = .014), with no significant differences in the reinfection rate. Capsulectomy was associated with longer procedural time (133.7 ± 78.5 vs. 89.9 ± 51.8 min, p = .002). No adverse reactions to CHG were found. Four patients (4.3%) died from worsening sepsis: three in the capsulectomy group and one in the CHG group (p = .346). CONCLUSIONS: In patients with CIED infections, the use of CHG without capsulectomy resulted in a lower risk of hematoma formation and shorter procedural times without an increased risk of reinfection or adverse events associated with CHG use.


Asunto(s)
Cardiopatías , Marcapaso Artificial , Humanos , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Masculino , Clorhexidina , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Irrigación Terapéutica , Reinfección/etiología , Cardiopatías/etiología
12.
J Cardiovasc Electrophysiol ; 34(12): 2493-2503, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37870157

RESUMEN

INTRODUCTION: The prospective, nonrandomized, multicenter Q-FFICIENCY study demonstrated the safety and 12-month efficacy of paroxysmal atrial fibrillation (AF) ablation with the novel QDOT MICRO temperature-controlled, contact force-sensing, radiofrequency (RF) catheter. Participants underwent pulmonary vein isolation with very high-power short-duration (vHPSD) mode (90 W, ≤4 s) alone or combined with conventional-power temperature-controlled (CPTC) mode (25-50 W). This study aimed to assess quality-of-life (QOL) and healthcare utilization (HCU) benefits experienced by Q-FFICIENCY study participants. METHODS: Besides evaluating procedural efficiency, QOL and HCU were assessed through 12 months postablation via Atrial Fibrillation Effect on Quality-of-Life Tool (AFEQT) score, antiarrhythmic drug (AAD) use, and incidence of cardioversion and cardiovascular hospitalization. RESULTS: Of 191 participants enrolled, 166 were ablated with the new catheter. Compared to baseline, statistically significant, clinically meaningful improvements in composite and subcategories of AFEQT scores were observed at 3 months and sustained through 12 months (12-month increase, 29.3-44.2 points). Class I/III AAD use decreased from 97.6% (162/166) at baseline to 19.6% (31/158) during Months 6-12, representing a significant 79.9% reduction. The cardioversion rate significantly declined by 93.9% from 31.3% (12 months preablation) to 1.9% (evaluation period). One-year Kaplan-Meier estimates of freedom from all-cause and cardiovascular hospitalization were 80.9% (95% confidence interval [CI], 74.8%-86.9%) and 88.8% (95% CI, 84.0%-93.7%), respectively. CONCLUSIONS: Paroxysmal AF ablation with the novel temperature-controlled RF catheter in vHPSD mode, alone or with CPTC mode, led to clinically meaningful improvement in QOL and significant reduction in AAD use, cardioversion, and cardiovascular hospitalization.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/tratamiento farmacológico , Estudios Prospectivos , Calidad de Vida , Temperatura , Resultado del Tratamiento , Catéteres , Antiarrítmicos/uso terapéutico , Venas Pulmonares/cirugía , Aceptación de la Atención de Salud , Ablación por Catéter/efectos adversos
13.
J Cardiovasc Electrophysiol ; 34(1): 147-152, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36378783

RESUMEN

INTRODUCTION: Atrial fibrillation (AF) and premature ventricular complexes (PVC) are common arrhythmias. We aimed to investigate AF prevalence in patients with PVC and its impact on PVC ablation outcomes. METHODS: Consecutive patients undergoing PVC ablation at a single institution between 2016 and 2019 were included and prospectively followed for 2 years. Patients with severe valvular heart disease, hyperthyroidism, malignancy, alcohol use disorder and advanced renal/hepatic diseases were excluded. Twelve-lead electrocardiograms were used to diagnose AF and assess PVC morphology. All PVCs were targeted for ablation using 4-mm irrigated-tip catheters at standardized radiofrequency power guided by 3-D mapping and intracardiac echocardiography. Patients were followed with remote monitoring, device interrogations and office visits every 6 months for 2 years. Detection of any PVCs in follow-up was considered as recurrence. RESULTS: A total of 394 patients underwent PVC ablation and 96 (24%) had concurrent AF. Patients with PVC and AF were significantly older (68.2 ± 10.8 vs. 58.3 ± 15.8 years, p < .001), had lower LV ejection fraction (43.3 ± 13.3% vs. 49.6 ± 12.4%, p < .001), higher CHA2 DS2 -VASc (2.8 ± 1.3 vs. 2.0 ± 1.3, p < .001) than those without. PVCs with ≥2 morphologies were detected in 60.4% and 13.7% patients with vs without AF (p < .001). At 2-year follow-up, PVC recurrence rate was significantly higher in patients with vs without AF (17.7% vs. 9.4%, p = .02). CONCLUSION: AF was documented in 1/4 of patients undergoing PVC ablation and was associated with lower procedural success at long-term follow-up. This was likely attributed to older age, worse LV function and higher prevalence of multiple PVC morphologies in patients with concurrent AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Complejos Prematuros Ventriculares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Prevalencia , Volumen Sistólico , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/epidemiología , Complejos Prematuros Ventriculares/cirugía , Ablación por Catéter/efectos adversos
14.
J Cardiovasc Electrophysiol ; 34(12): 2527-2534, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37746923

RESUMEN

INTRODUCTION: Earlier studies have shown a clear association between severity of human immunodeficiency virus (HIV) infection and incident atrial fibrillation (AF). We present the long-term outcome of catheter ablation (CA) and electrophysiological characteristics in HIV+ AF patients. METHODS: This study evaluated 1438 consecutive AF patients [31 (2.15%) with HIV and 1407 (97.8%) without HIV diagnosis] undergoing their first CA at our center. A total of 31 HIV patients and 31 controls were generated by propensity matching, based on calculated risk factor scores, using a logistic model. During first procedure, all received isolation of pulmonary vein (PV) + posterior wall and superior vena cava. Non-PV triggers, defined as ectopic triggers originating from sites other than PVs, were identified at the redo ablation with high-dose isoproterenol challenge. RESULTS: Clinical characteristics were not different between the groups. When compared to the control, by the end of 5 years after the first procedure, recurrence was significantly greater in HIV group [100% vs. 54%, p < .001]. Among patients that underwent redo ablation non-PV triggers were higher in HIV group [93.5% vs. 54%, p < .001], and most frequently originated from the coronary sinus [67.7% vs. 45.2%, p < .001] and left atrial appendage [41.9% vs. 25.8%, p < .001]. After focal ablation of non-PV trigger, no difference in arrhythmia recurrence between two groups [80.6% vs. 87.1%, p = .753] at 1-year follow up was found. CONCLUSION: Our findings suggest that non-PV triggers are highly prevalent in HIV+ AF patients resulting in higher rate of the mid- and long-term arrhythmia recurrence.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Infecciones por VIH , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Resultado del Tratamiento , Infecciones por VIH/complicaciones , Infecciones por VIH/diagnóstico , Vena Cava Superior , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia
15.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37622589

RESUMEN

This article will discuss the past, present, and future of ventricular tachycardia ablation and the continuing contribution of the Europace journal as the platform for publication of milestone research papers in this field of ventricular tachycardia ablation.


Asunto(s)
Ablación por Catéter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Ablación por Catéter/efectos adversos
16.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37503957

RESUMEN

AIMS: Left atrial appendage occlusion (LAAO) with WATCHMAN device is being used for patients with atrial fibrillation (AFB) and, as an off-label use, atrial flutter (AFL) who can't comply with long-term anticoagulation. We aim to study the differences in outcomes between sexes in patients undergoing Watchman device implantation. METHODOLOGY: The National Inpatient Sample was queried between 2016 and 2019 using ICD-10 clinical modification codes I48x for AFB and AFL. Patients who underwent LAAO were identified using the procedural code 02L73DK. Comorbidities and complications were identified using ICD procedure and diagnosis codes. Differences in primary outcomes were analyzed using multivariable regression and propensity score matching. RESULTS: 38 105 admissions were identified, of which 16 795 (44%) were females (76 ± 7.6 years) and 21 310 (56%) were males (75 ± 8 years). Females were more likely to have cardiac (frequencies: 5.8% vs 3.75%, aOR: 1.5 [1.35-1.68], p1 day inpatient (1.79 [1.67-1.93], P < 0.01) and be discharged to a facility (1.54 [1.33-1.80], P < 0.01). CONCLUSION: Females are more likely to develop cardiac, renal, bleeding, pulmonary and TEE-related complications following LAAO procedure, while concurrently showing higher mortality, length of stay and discharge to facilities.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Enfermedades Vasculares , Masculino , Humanos , Femenino , Resultado del Tratamiento , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Hemorragia , Hospitales , Enfermedades Vasculares/etiología , Cateterismo Cardíaco , Accidente Cerebrovascular/etiología
17.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37712644

RESUMEN

AIMS: Since their introduction in 1958, traditional cardiac pacemakers have undergone considerable upgrades over the years, but they continue to have a complication rate of ∼3.8%-12.4%. There are no randomized controlled trials comparing outcomes of leadless pacemakers (LPM) with single-chamber transvenous pacemakers (TV-VVI). The aim is to assess the differences in the procedural complications and in-hospital outcomes between LPM and TV-VVI implants. METHODS AND RESULTS: We queried the national inpatient database from 2016 to 2019 to include adult patients undergoing LPM and TV-VVI. Admissions for leadless and single-lead transvenous pacemakers were identified by their appropriate ICD-10 codes. Complications were identified using ICD-10 codes that mostly represent initial encounter. The difference in outcomes was assessed using multivariable logistic regression and 1:1 propensity score matching between the two cohorts. Thirty-five thousand four hundred thirty expanded samples of admissions were retrieved of which 27 650 (78%) underwent TV-VVI with a mean age 81.3 ± 9.4 years and 7780 (22%) underwent LPM with a mean age of 77.1 ± 12.1 years. The LPM group had a higher likelihood of in-hospital mortality [adjusted odds ratio (aOR): 1.63, 95% CI (1.29-2.05), P < 0.001], vascular complications [aOR: 7.54, 95% CI (3.21-17.68), P < 0.001], venous thromboembolism [aOR: 3.67, 95% CI (2.68-5.02), P < 0.001], cardiac complications [aOR: 1.79, 95% CI (1.59-2.03), P < 0.001], device thrombus formation [aOR: 5.03, 95% CI (2.55-9.92), P < 0.001], and need for a blood transfusion [aOR: 1.54, 95% CI (1.14-2.07), P < 0.005]. The TV-VVI group had higher likelihood of in-hospital pulmonary complications [aOR:0.68, 95% CI (0.54-0.87), P < 0.002] and had a need for device revisions [aOR:0.42, 95% CI (0.23-0.76), P < 0.004]. CONCLUSION: There is a higher likelihood of all-cause in-hospital mortality and complications following LPM implantation in comparison to TV-VVI. This could be related to higher co-morbidities in the LPM group. Clinical trials aimed to accurately compare these two groups should be undertaken.


Asunto(s)
Arritmias Cardíacas , Marcapaso Artificial , Adulto , Humanos , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Puntaje de Propensión , Hospitales , Resultado del Tratamiento
18.
Europace ; 25(5)2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37078691

RESUMEN

AIMS: Prevalent atrial fibrillation (AF) is associated with excess cardiovascular (CV) death (D) and hospitalizations (H) in heart failure (HF) with preserved ejection fraction (pEF). We evaluated if it had an independent role in excess CVD in HFpEF and studied its impact on cause-specific mortality and HF morbidity. METHODS AND RESULTS: We used propensity score-matched (PSM) cohorts from the TOPCAT Americas trial to account for confounding by other co-morbidities. Two prevalent AF presentations at study entry were compared: (i) subjects with Any AF event by history or on electrocardiogram (ECG) with PSM subjects without an AF event and (ii) subjects in AF on ECG with PSM subjects in sinus rhythm. We analyzed cause-specific modes of death and HF morbidity during a mean follow-up period of 2.9 years. A total of 584 subjects with Any AF event and 418 subjects in AF on ECG were matched. Any AF was associated with increased CVH [hazard ratio (HR) 1.33, 95% confidence interval (CI) 1.11-1.61, P = 0.003], HFH (HR 1.44, 95% CI 1.12-1.86, P = 0.004), pump failure death (PFD) (HR 1.95, 95% CI 1.05-3.62, P = 0.035), and HF progression from New York Heart Association (NYHA) classes I/II to III/IV (HR 1.30, 95% CI 1.04-1.62, P = 0.02). Atrial fibrillation on ECG was associated with increased risk of CVD (HR 1.46, 95% CI 1.02-2.09, P = 0.039), PFD (HR 2.21, 95% CI 1.11-4.40, P = 0.024), and CVH and HFH (HR 1.37, 95% CI 1.09-1.72, P = 0.006 and HR 1.65, 95% CI 1.22-2.23, P = 0.001, respectively). Atrial fibrillation was not associated with risk of sudden death. Both Any AF and AF on ECG cohorts were associated with PFD in NYHA class III/IV HF. CONCLUSION: Prevalent AF can be an independent risk factor for adverse CV outcomes by its selective association with worsening HF, HFH, and PFD in HFpEF. Prevalent AF was not associated with excess sudden death risk in HFpEF. Atrial fibrillation was also associated with HF progression in early symptomatic HFpEF and PFD in advanced HFpEF. TRIAL REGISTRATION: TOPCAT trial is registered at www.clinicaltrials.gov:identifier NCT00094302.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Humanos , Fibrilación Atrial/epidemiología , Volumen Sistólico/fisiología , Puntaje de Propensión , Comorbilidad , Pronóstico
19.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37477946

RESUMEN

AIMS: Intracardiac echocardiography (ICE) is a useful but operator-dependent tool for left atrial (LA) anatomical rendering during atrial fibrillation (AF) ablation. The CARTOSOUND FAM Module, a new deep learning (DL) imaging algorithm, has the potential to overcome this limitation. This study aims to evaluate feasibility of the algorithm compared to cardiac computed tomography (CT) in patients undergoing AF ablation. METHODS AND RESULTS: In 28 patients undergoing AF ablation, baseline patient information was recorded, and three-dimensional (3D) shells of LA body and anatomical structures [LA appendage/left superior pulmonary vein/left inferior pulmonary vein/right superior pulmonary vein/right inferior pulmonary vein (RIPV)] were reconstructed using the DL algorithm. The selected ultrasound frames were gated to end-expiration and max LA volume. Ostial diameters of these structures and carina-to-carina distance between left and right pulmonary veins were measured and compared with CT measurements. Anatomical accuracy of the DL algorithm was evaluated by three independent electrophysiologists using a three-anchor scale for LA anatomical structures and a five-anchor scale for LA body. Ablation-related characteristics were summarized. The algorithm generated 3D reconstruction of LA anatomies, and two-dimensional contours overlaid on ultrasound input frames. Average calculation time for LA reconstruction was 65 s. Mean ostial diameters and carina-to-carina distance were all comparable to CT without statistical significance. Ostial diameters and carina-to-carina distance also showed moderate to high correlation (r = 0.52-0.75) except for RIPV (r = 0.20). Qualitative ratings showed good agreement without between-rater differences. Average procedure time was 143.7 ± 43.7 min, with average radiofrequency time 31.6 ± 10.2 min. All patients achieved ablation success, and no immediate complications were observed. CONCLUSION: DL algorithm integration with ICE demonstrated considerable accuracy compared to CT and qualitative physician assessment. The feasibility of ICE with this algorithm can potentially further streamline AF ablation workflow.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Inteligencia Artificial , Estudios de Factibilidad , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Imagenología Tridimensional/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Algoritmos , Ablación por Catéter/métodos
20.
Europace ; 25(1): 175-184, 2023 02 08.
Artículo en Inglés | MEDLINE | ID: mdl-36196043

RESUMEN

AIMS: The aim of this study is to provide guidance for the clinical interpretation of electrocardiograms (ECGs) in prone position and to establish the electroanatomic explanations for the possible differences to supine position ECGs that may be observed. Additionally, to determine if prone back ECG can be used as an alternative to standard ECG in patients who may benefit from prone position. METHODS AND RESULTS: The ECG in supine (standard ECG), prone back (precordial leads placed on the patient's back), and prone anterior position (precordial leads placed in the standard position with the subjects in prone position) were prospectively examined on 85 subjects. Comparisons of ECG parameters between these positions were performed. Computed tomography (CT) scans were performed in both positions to determine possible electroanatomic aetiologies for prone-associated ECG changes. There were significant differences in QRS amplitude in Leads V1-V5 between supine and prone positions. Q waves were more frequently observed in prone back position vs. supine position (V1: 74.1 vs. 10.6%, P < 0.0001; V2: 23.5 vs. 0%, P < 0.0001, respectively). Flat and inverted T waves were more common in prone back leads (V1: 98 vs. 66%, P < 0.0001; V2: 96 vs. 8%, P < 0.0001; V3: 45 vs. 7%, P < 0.0001). The 3D-CT reconstructions measurements corroborated the significant inverse correlation between QRS amplitude and the distance from the centre of the heart to the estimated lead positions. CONCLUSION: In prone back position ECG, low QRS amplitude should not be misinterpreted as low voltage conditions, neither should Q waves and abnormal T waves are considered anteroseptal myocardial infarction. These changes can be explained by an increased impedance (due to interposing lung tissue) and by the increased distance between the electrodes to the centre of the heart.


Asunto(s)
Electrocardiografía , Posicionamiento del Paciente , Humanos , Posición Prona , Estudios Prospectivos , Electrocardiografía/métodos , Corazón
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA