Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
J Perinat Med ; 52(1): 114-116, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-37851901

RESUMEN

OBJECTIVES: The primary objective was to evaluate the effects of fetal sex on fetal cortical development in low-risk pregnancies. Secondary objective was the evaluate the impact of gestational age. METHODS: This was a secondary analysis of a prospective cross-sectional study on low-risk fetuses undergoing fetal neurosonography between 19 and 34 weeks of gestation. The depth of Sylvian Fissure (SF), Parieto Occipital Fissure (POF) and Calcarine Fissure (CF) were evaluated and related to fetal sex. Neurosonographic variables were normalized for fetal head circumference and expressed as multiple of the median (MoM). RESULTS: A total of 344 fetuses were considered (173 male, 171 female). The baseline characteristic of the two groups were similar except a higher birthweight present in male fetuses (p=0.044). The depth SF (p=0.023) CF (p=0.014) and POF (p=0.046) showed significantly higher values in male fetuses when all the gestational age range was considered. However, when data were controlled for gestational age, these differences resulted significant only after 28 weeks. CONCLUSIONS: Differences in cortical development related to gender occur after 28 weeks of gestation with an increase depth of SF, POF and CF in male fetuses.


Asunto(s)
Desarrollo Fetal , Ultrasonografía Prenatal , Embarazo , Humanos , Masculino , Femenino , Lactante , Estudios Transversales , Estudios Prospectivos , Ultrasonografía Prenatal/métodos , Edad Gestacional
2.
J Perinat Med ; 52(5): 457-466, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38651628

RESUMEN

OBJECTIVES: To report the outcome of fetuses with a prenatal diagnosis of congenital lung malformation (CLM) diagnosed on ultrasound by performing a comprehensive assessment of these outcomes through a systematic review and meta-analysis. CONTENT: CLMs are a heterogeneous group of anomalies that involve the lung parenchyma and its bronchovascular structures. Their presentation and evolution are variable, from entirely asymptomatic lesions with sonographic regression in utero to hydropic fetuses requiring fetal therapy, intrauterine death or neonatal morbidity. A systematic review was conducted in Medline, Embase and Cochrane databases including studies on fetuses with CLM diagnosed prenatally in order to report the in-utero natural history of these lesions. Thirty-nine studies (2,638 fetuses) were included in the final review. SUMMARY: Regression/reduction in size of the lung lesion during pregnancy was reported in 31 % of cases, while its increase in 8.5 % of cases. Intra-uterine death complicated 1.5 % of pregnancies with fetal CLM, while neonatal and perinatal death were 2.2 and 3 %, respectively. Neonatal morbidity occurred in 20.6 % of newborns with CLM; 46 % had surgery, mainly elective. In fetuses with CLM and hydrops, fetal/perinatal loss occurred in 42 %. Assessment of the role of fetal therapy in improving the outcomes of pregnancies complicated by CLM was hampered by the small number of included cases and heterogeneity of type of interventions. OUTLOOK: Fetuses with CLM prenatally diagnosed have a generally favorable outcome. Conversely, there is a low quality of evidence on the actual role of fetal therapy in improving the outcome of fetuses presenting with these anomalies.


Asunto(s)
Ultrasonografía Prenatal , Humanos , Embarazo , Femenino , Recién Nacido , Pulmón/anomalías , Pulmón/diagnóstico por imagen , Resultado del Embarazo/epidemiología
3.
Am J Obstet Gynecol ; 229(4): 377-387, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37044237

RESUMEN

OBJECTIVE: This study aimed to evaluate the rate of adverse neonatal or maternal outcomes in parturients with fetal heart rate tracings categorized as I, II or, III within the last 30 to 120 minutes of delivery. DATA SOURCES: The MEDLINE Ovid, Scopus, Embase, CINAHL, and Clinicaltrials.gov databases were searched electronically up to May 2022, using combinations of the relevant medical subject heading terms, keywords, and word variants that were considered suitable for the topic. STUDY ELIGIBILITY CRITERIA: Only observational studies of term infants reporting outcomes of interest with category I, II, or III fetal heart rate tracings were included. STUDY APPRAISAL AND SYNTHESIS METHODS: The coprimary outcome was the rate of either Apgar score <7 at 5 minutes or umbilical artery pH <7.00. Secondary outcomes were divided into neonatal and maternal adverse outcomes. Quality assessment of the included studies was performed using the Newcastle-Ottawa Scale. Random-effect meta-analyses of proportions were used to estimate the pooled rates of each categorical outcome in fetal heart rate tracing category I, II, and III patterns, and random-effect head-to-head meta-analyses were used to directly compare fetal heart rate tracings category I vs II and fetal heart rate tracing category II vs III, expressing the results as summary odds ratio or as mean differences with relative 95% confidence intervals. RESULTS: Of the 671 articles reviewed, 3 publications met the inclusion criteria. Among them were 47,648 singletons at ≥37 weeks' gestation. Fetal heart rate tracings in the last 30 to 120 minutes before delivery were characterized in the following manner: 27.0% of deliveries had category I tracings, 72.9% had category II tracings, and 0.1% had category III tracings. A single study, which was rated to be of poor quality, contributed 82.1% of the data and it did not provide any data for category III fetal heart rate tracings. When compared with category I fetal heart rate tracings (0.74%), the incidence of an Apgar score <7 at 5 minutes were significantly higher among deliveries with category II fetal heart rate tracings (1.51%) (odds ratio, 1.56; 95% confidence interval, 1.23-1.99) and among those with category III tracings (14.63%) (odds ratio, 14.46; 95% confidence interval, 2.77-75.39). When compared with category II tracings, category III tracings also had a significantly higher likelihood of a low Apgar score at 5 minutes (odds ratio, 14.46; 95% confidence interval, 2.77-75.39). The incidence of an umbilical artery pH <7.00 were similar among those with category I and those with category II tracings (0.08% vs 0.24%; odds ratio, 2.85; 95% confidence interval, 0.41-19.55). When compared with category I tracings, the incidence of an umbilical artery pH <7.00 was significantly more common among those with category III tracings (31.04%; odds ratio, 161.56; 95% confidence interval, 25.18-1036.42); likewise, when compared with those with category II tracings, those with category III tracings had a significantly higher likelihood of having an umbilical artery pH <7.00 (odds ratio, 42.29; 95% confidence interval, 14.29-125.10). Hypoxic-ischemic encephalopathy occurred with similar frequency among those with categories I and those with category II tracings (0 vs 0.81%; odds ratio, 5.86; 95% confidence interval, 0.75-45.89) but was significantly more common among those with category III tracings (0 vs 18.97%; odds ratio, 61.43; 95% confidence interval, 7.49-503.50). Cesarean delivery occurred with similar frequency among those with category I (13.41%) and those with category II tracings (11.92%) (odds ratio, 0.87; 95% confidence interval, 0.72-1.05) but was significantly more common among those with with category III tracings (14.28%) (odds ratio, 3.97; 95% confidence interval, 1.62-9.75). When compared with those with category II tracings, cesarean delivery was more common among those with category III tracings (odds ratio, 4.55; 95% confidence interval, 1.88-11.01). CONCLUSION: Although the incidence of an Apgar score <7 at 5 minutes and umbilical artery pH <7.00 increased significantly with increasing fetal heart rate tracing category, about 98% of newborns with category II tracings do not have these adverse outcomes. The 3-tiered fetal heart rate tracing interpretation system provides an approximate but imprecise measurement of neonatal prognosis.


Asunto(s)
Frecuencia Cardíaca Fetal , Enfermedades del Recién Nacido , Embarazo , Lactante , Femenino , Recién Nacido , Humanos , Cardiotocografía/métodos , Cesárea , Enfermedades del Recién Nacido/epidemiología , Pronóstico
4.
Prenat Diagn ; 43(11): 1425-1432, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37684739

RESUMEN

To evaluate obstetrical outcomes for women having late amniocentesis (on or after 24 weeks). Electronic databases were searched from inception to January 1st, 2023. The obstetrical outcomes evaluated were gestational age at delivery, preterm birth (PTB) < 37 weeks, PTB within 1 week from amniocentesis, premature prelabor rupture of membranes (pPROM), chorionamnionitis, placental abruption, intrauterine fetal demise (IUFD) and termination of pregnancy (TOP). The incidence of PTB <37 weeks was 4.85% (95% CI 3.48-6.56), while the incidence of PTB within 1 week was 1.42% (95% CI 0.66-2.45). The rate of pPROM was 2.85% (95% CI 1.21-3.32). The incidence of placental abruption was 0.91% (95% CI 0.16-2.25), while the rate of IUFD was 3.66% (95% CI 0.00-14.04). The rate of women who underwent TOP was 6.37% (95%CI 1.05-15.72). When comparing amniocentesis performed before or after 32 weeks, the incidence of PTB within 1 week was 1.48% (95% CI 0.42-3.19) and 2.38% (95% CI 0.40-5.95). Amniocentesis performed late after 24 weeks of gestation is an acceptable option for patients needing prenatal diagnosis in later gestation.


Asunto(s)
Desprendimiento Prematuro de la Placenta , Rotura Prematura de Membranas Fetales , Nacimiento Prematuro , Embarazo , Femenino , Recién Nacido , Humanos , Lactante , Nacimiento Prematuro/epidemiología , Nacimiento Prematuro/etiología , Amniocentesis/efectos adversos , Placenta , Rotura Prematura de Membranas Fetales/epidemiología , Rotura Prematura de Membranas Fetales/etiología , Mortinato , Edad Gestacional
5.
J Perinat Med ; 51(1): 102-110, 2023 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-35993868

RESUMEN

OBJECTIVES: To identify predictors of adverse perinatal outcome in congenital cytomegalovirus (CMV) infection. METHODS: In a multicenter study fetuses with congenital CMV infection diagnosed by PCR on amniotic fluid and normal prenatal imaging at the time of diagnosis were included. Primary outcome was the occurrence of structural anomalies at follow-up ultrasound or prenatal magnetic resonance imaging (MRI). Secondary outcomes were the occurrence of anomalies detected exclusively postnatally and the rate of symptomatic infection. RESULTS: One hundred and four fetuses with congenital CMV were included in the study. Anomalies were detected at follow-up ultrasound or MRI in 18.3% (19/104) cases. Additional anomalies were found after birth in 11.9% (10/84) of cases and 15.5% (13/85) of newborns showed clinical symptoms related to CMV infection. There was no difference in either maternal age (p=0.3), trimester (p=0.4) of infection and prenatal therapy (p=0.4) between fetuses with or whiteout anomalies at follow-up. Conversely, median viral load in the amniotic fluid was higher in fetuses with additional anomalies at follow-up (p=0.02) compared to those without. At multivariate logistic regression analysis, high viral load in the amniotic fluid, defined as ≥100,000 copies/mL was the only independent predictor for the occurrence of anomalies detected exclusively at follow-up ultrasound assessment or MRI, with an OR of 3.12. CONCLUSIONS: Viral load in the amniotic fluid is a strong predictor of adverse perinatal outcome in congenital CMV infection. The results of this study emphasize the importance of adequate follow up even in case of negative neurosonography to better predict postnatal adverse outcomes of infected newborns, especially in amniotic fluid high viral load.


Asunto(s)
Infecciones por Citomegalovirus , Enfermedades Fetales , Complicaciones Infecciosas del Embarazo , Embarazo , Femenino , Recién Nacido , Humanos , Complicaciones Infecciosas del Embarazo/diagnóstico , Complicaciones Infecciosas del Embarazo/epidemiología , Ultrasonografía Prenatal/métodos , Enfermedades Fetales/diagnóstico , Enfermedades Fetales/epidemiología , Infecciones por Citomegalovirus/diagnóstico , Infecciones por Citomegalovirus/diagnóstico por imagen , Líquido Amniótico/diagnóstico por imagen
6.
J Perinat Med ; 51(9): 1212-1219, 2023 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-37596832

RESUMEN

OBJECTIVES: To develop charts for fetal brain cortical structures following a proposed standardized methodology and using quantile regression. METHODS: Prospective cross-sectional study including 344 low-risk singleton pregnancies between 19 and 34 weeks of gestation. The depth of Sylvian (SF), Parieto-occipital (POF) and Calcarine fissures (CF) were measured on ultrasound images using a standardized technique and their changes were evaluated by quantile regression as a function of gestational age (GA) interval or head circumference (HC). RESULTS: The measurements of SF, POF and CF depth significantly increased with gestation. Linear models better described the changes of cortical variables with GA and HC. When the fit of sulci depth with GA and HC were compared, a close relationship was highlighted for the latter variable. CONCLUSIONS: We provided prospective charts of fetal cortical development using quantile regression and following a strict standardized methodology These new charts may help in better identifying cases at higher risk of abnormal cortical neurodevelopment.


Asunto(s)
Desarrollo Fetal , Ultrasonografía Prenatal , Embarazo , Femenino , Humanos , Edad Gestacional , Estudios Transversales , Estudios Prospectivos , Ultrasonografía Prenatal/métodos , Valores de Referencia
7.
Fetal Diagn Ther ; 50(1): 1-7, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36623501

RESUMEN

INTRODUCTION: The aim of the study was to report the prognostic value of cytomegalovirus (CMV) viral load in the amniotic fluid (AF) in predicting the outcome of infected pregnancies. METHODS: Multicenter retrospective study involving 11 Italian referral centers from 2012 to 2021 was conducted. Inclusion criteria were fetuses with confirmed congenital CMV infection. The primary outcome was the prognostic value accuracy of CMV quantitative polymerase chain reaction (qPCR) in AF in predicting the risk of additional anomalies detected either at follow-up ultrasound or fetal magnetic resonance imaging (MRI). The secondary outcome was prediction of postnatal clinical symptoms related to CMV infection. Multivariate logistic regression and area under the curve (AUC) analyses were used to analyze the data. RESULTS: 104 fetuses were included. Associated anomalies detected at follow-up ultrasound or fetal MRI were detected in 14.4% of cases (15/104). Mean AF CMV viral load was significantly higher in fetuses with additional anomalies compared to those without additional anomalies at follow-up ultrasound or fetal MRI (3,346,634.27 ± 402,582.95 vs. 761,934 ± 222513,2 p < 0.001). At multivariate logistic regression analysis, CMV AF viral load was independently associated with the presence of additional anomalies at follow-up ultrasound or MRI, with an OR of 1.07 (p = 0.010), while maternal age (p = 0.24), trimester at maternal infection (p = 0.97), and type of infection (primary vs. non-primary) (p = 0.12) were not. CMV AF viral load had AUC of 0.755 for the occurrence of anomalies due to CMV infection, with an optimal cut-off point of >1,310,520 copies/mL, a sensitivity of 66.7%, a specificity of 84.3%, and a positive likelihood ratio of 4.24. Once excluding fetuses with anomalies at ultrasound or MRI, the diagnostic performance of qPCR in identifying fetuses with symptomatic infection after birth was low, with an AUC of 0.586. CONCLUSION: CMV viral load at second trimester amniocentesis has a moderate accuracy for the occurrence of CMV-related anomalies in fetuses with congenital infection and normal ultrasound at the initial diagnosis. Conversely, prediction of symptomatic infection is low.


Asunto(s)
Infecciones por Citomegalovirus , Complicaciones Infecciosas del Embarazo , Embarazo , Femenino , Humanos , Líquido Amniótico/diagnóstico por imagen , Pronóstico , Citomegalovirus , Complicaciones Infecciosas del Embarazo/diagnóstico , Carga Viral , Estudios Retrospectivos , Infecciones por Citomegalovirus/diagnóstico , Infecciones por Citomegalovirus/diagnóstico por imagen
8.
J Clin Ultrasound ; 51(7): 1172-1178, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37553773

RESUMEN

Echogenic fetal bowel (EB) is a prenatal ultrasound finding (0.2%-1.4% of all pregnancies) defined as bowel of similar or greater echogenicity than surrounding bone. In fact, the ultrasound assessment is strongly subjective with inter-observer variability. The pathophysiology depends on the underlying condition, apparently related with meconium stasis and hypercellularity. It is often an isolated finding, with possible association with other structural anomalies. About the origin, it was observed in fetuses with cystic fibrosis, congenital infections, thalassemia, intraamniotic bleeding, fetal growth restriction. Fetuses with EB are at increased risk of adverse perinatal outcome, such as intrauterine growth restriction, placental dysfunction and perinatal death, highlighting the need for a thorough antenatal management and post-natal follow-up. It seems to be associated with a plenty of conditions, such as a poor fetal outcome, fetal growth restriction and placental dysfunction. Therefore management requires a multidisciplinary approach with different specialties' involvement and the prognosis is influenced by the underlying pathophysiology. In this complex scenario, the present review aims to define the clinical pathway which should be offered to pregnant women in case of finding of fetal EB ultrasound marker, to rule out any suspected pathological cause.


Asunto(s)
Intestino Ecogénico , Resultado del Embarazo , Embarazo , Femenino , Humanos , Retardo del Crecimiento Fetal/diagnóstico por imagen , Ultrasonografía Prenatal , Placenta/diagnóstico por imagen , Diagnóstico Prenatal , Feto
9.
Am J Obstet Gynecol ; 226(4): 499-509, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34492220

RESUMEN

OBJECTIVE: This study aimed to assess the efficacy of sonographic assessment of fetal occiput position before operative vaginal delivery to decrease the number of failed operative vaginal deliveries. DATA SOURCES: The search was conducted in MEDLINE, Embase, Web of Science, Scopus, ClinicalTrial.gov, Ovid, and Cochrane Library as electronic databases from the inception of each database to April 2021. No restrictions for language or geographic location were applied. STUDY ELIGIBILITY CRITERIA: Selection criteria included randomized controlled trails of pregnant women randomized to either sonographic or clinical digital diagnosis of fetal occiput position during the second stage of labor before operative vaginal delivery. METHODS: The primary outcome was failed operative vaginal delivery, defined as a failed fetal operative vaginal delivery (vacuum or forceps) extraction requiring a cesarean delivery or forceps after failed vacuum. The summary measures were reported as relative risks or as mean differences with 95% confidence intervals using the random effects model of DerSimonian and Laird. An I2 (Higgins I2) >0% was used to identify heterogeneity. RESULTS: A total of 4 randomized controlled trials including 1007 women with singleton, term, cephalic fetuses randomized to either the sonographic (n=484) or clinical digital (n=523) diagnosis of occiput position during the second stage of labor before operative vaginal delivery were included. Before operative vaginal delivery, fetal occiput position was diagnosed as anterior in 63.5% of the sonographic diagnosis group vs 69.5% in the clinical digital diagnosis group (P=.04). There was no significant difference in the rate of failed operative vaginal deliveries between the sonographic and clinical diagnosis of occiput position groups (9.9% vs 8.2%; relative risk, 1.14; 95% confidence interval, 0.77-1.68). Women randomized to sonographic diagnosis of occiput position had a significantly lower rate of occiput position discordance between the evaluation before operative vaginal delivery and the at birth evaluation when compared with those randomized to the clinical diagnosis group (2.3% vs 17.7%; relative risk, 0.16; 95% confidence interval, 0.04-0.74; P=.02). There were no significant differences in any of the other secondary obstetrical and perinatal outcomes assessed. CONCLUSION: Sonographic knowledge of occiput position before operative vaginal delivery does not seem to have an effect on the incidence of failed operative vaginal deliveries despite better sonographic accuracy in the occiput position diagnosis when compared with clinical assessment. Future studies should evaluate how a more accurate sonographic diagnosis of occiput position or other parameters can lead to a safer and more effective operative vaginal delivery technique.


Asunto(s)
Presentación en Trabajo de Parto , Ultrasonografía Prenatal , Parto Obstétrico , Femenino , Humanos , Recién Nacido , Embarazo , Ensayos Clínicos Controlados Aleatorios como Asunto , Ultrasonografía
10.
Am J Perinatol ; 39(3): 243-251, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-32722824

RESUMEN

OBJECTIVE: This study was aimed to report the incidence of neonatal morbidity in monochorionic monoamniotic (MCMA) twin pregnancies according to gestational age at birth and type of management adopted (inpatient or outpatient). STUDY DESIGN: Medline and Embase databases were searched. Inclusion criteria were nonanomalous MCMA twins. The primary outcome was a composite score of neonatal morbidity, defined as the occurrence of at least one of the following outcomes: respiratory morbidity, overall neurological morbidity, severe neurological morbidity, and infectious morbidity, necrotizing enterocolitis at different gestational age windows (24-30, 31-32, 33-34, and 35-36 weeks). Secondary outcomes were the individual components of the primary outcome and admission to neonatal intensive care unit (NICU). Subanalysis according to the type of surveillance strategy (inpatient compared with outpatient) was also performed. Random effect meta-analyses were used to analyze the data. RESULTS: A total of 14 studies including 685 MCMA twin pregnancies without fetal anomalies were included. At 24 to 30, 31 to 32, 33 to 34, and 35 to 36 weeks of gestation, the rate of composite morbidity was 75.4, 65.5, 37.6, and 18.5%, respectively, the rate of respiratory morbidity was 74.2, 59.1, 35.5, and 12.2%, respectively, while overall neurological morbidity occurred in 15.3, 10.2, 4.3, and 0% of the cases, respectively. Infectious morbidity complicated 13, 4.2, 3.1, and 0% of newborns while 92.1, 81.6, 58.7, and 0% of cases required admission to NICU. Morbidity in pregnancies delivered between 35 and 36 weeks of gestation was affected by the very small sample size of cases included. When comparing the occurrence of overall morbidity according to the type of management (inpatient or outpatient), there was no difference between the two surveillance strategies (p = 0.114). CONCLUSION: MCMA pregnancies are at high risk of composite neonatal morbidity, mainly respiratory morbidity that gradually decreases with increasing gestational age at delivery with a significant reduction for pregnancies delivered between 33 and 34 weeks. We found no difference in the occurrence of neonatal morbidity between pregnancies managed as inpatient or outpatient. KEY POINTS: · MCMA pregnancies are at high risk of composite neonatal morbidity, mainly respiratory morbidity.. · Neonatal morbidity gradually decreases with increasing GA at delivery, mostly between 33 and 34 weeks.. · There is no difference in the occurrence of neonatal morbidity between in- or outpatient management..


Asunto(s)
Enfermedades del Recién Nacido/epidemiología , Embarazo Gemelar , Trastornos Respiratorios/epidemiología , Gemelos Monocigóticos , Femenino , Edad Gestacional , Humanos , Incidencia , Recién Nacido , Embarazo , Estudios en Gemelos como Asunto
11.
Fetal Diagn Ther ; 49(4): 145-158, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35462359

RESUMEN

INTRODUCTION: Several fetal brain charts have been published in the literature and are commonly used in the daily clinical practice. However, the methodological quality of these charts has not been critically appraised. MATERIAL AND METHODS: MEDLINE, EMBASE, CINAHL, and the Web of Science databases were searched electronically up to December 31, 2020. The primary outcome was to evaluate the methodology of the studies assessing the growth of fetal brain structures throughout gestation. A list of 28 methodological quality criteria divided into three domains according to "study design," "statistical and reporting methods," and "specific relevant neurosonography aspects" was developed in order to assess the methodological appropriateness of the included studies. The overall quality score was defined as the sum of low risk of bias marks, with the range of possible scores being 0-28. This quality assessment was applied to each individual study reporting reference ranges for fetal brain structures. Furthermore, we performed a subgroup analysis according to the different brain structures (ventricular and periventricular, fore-brain and midbrain cerebral and posterior fossa). RESULTS: Sixty studies were included in the systematic review. The overall mean quality score of the studies included in this review was 51.3%. When focusing on each of the assessed domains, the mean quality score was 53.7% for "study design," 54.2% for "statistical and reporting methods," and 38.6% for "specific relevant neurosonography aspects." The sample size calculation, the correlation with a postnatal imaging evaluation, and the whole fetal brain assessment were the items at the highest risk of bias for each domain assessed, respectively. The subgroup analysis according to different anatomical location showed the lowest quality score for ventricular and periventricular structures and the highest for cortical structures. CONCLUSIONS: Most previously published studies reporting fetal brain charts suffer from poor methodology and are at high risk of biases, mostly when focusing on neurosonography issues. Further prospective longitudinal studies aiming at constructing specific growth charts for fetal brain structures should follow rigorous methodology to minimize the risk of biases, guarantee higher levels of reproducibility, and improve the standard of care.


Asunto(s)
Feto , Ultrasonografía Prenatal , Encéfalo/diagnóstico por imagen , Femenino , Humanos , Embarazo , Estudios Prospectivos , Reproducibilidad de los Resultados , Ultrasonografía Prenatal/métodos
12.
Acta Obstet Gynecol Scand ; 100(2): 210-219, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32979219

RESUMEN

INTRODUCTION: The role of prenatal ultrasound in correctly identifying the level of the lesion in fetuses with open spina bifida has yet to be determined. The primary aim of this systematic review was to report the diagnostic accuracy of ultrasound in determining the level of the lesion in fetuses with open spina bifida. The secondary aim was to elucidate whether prenatal magnetic resonance imaging (MRI) improves the diagnostic performance of prenatal imaging in correctly identifying the level of the lesion. MATERIAL AND METHODS: Inclusion criteria were studies reporting the agreement between ultrasound, MRI and postnatal or postmortem assessment of fetuses with spina bifida. Agreement was defined as: complete (when the upper level of the lesion detected prenatally was the same recorded at postnatal or postmortem evaluation), within one (when the upper level of the lesion recorded prenatally was within one vertebral body higher or lower than that reported postnatally) and within two vertebral bodies (when the upper level of the lesion recorded prenatally was within two vertebral bodies higher or lower than that reported postnatally or postmortem evaluation). Meta-analyses of proportions were used to combine data. RESULTS: Fourteen studies (655 fetuses) were included. Ultrasound was able to identify the correct level of the lesion in 40.9% (95% confidence interval [CI] 26.9-55.6) of cases. The upper level of the lesion recorded on ultrasound was within one vertebral body in 76.2% (95% CI 65.0-85.9) of cases and within two segments in 92.4% (95% CI 84.3-97.7). Fetal MRI detected the exact level of the lesion in 42.5% (95% CI 35.9-45.2) of cases; the level of the lesion recorded on MRI was higher in 26.4% (95% CI 20.0-33.3) of cases and lower in 32.4% (95% CI 25.5-39.7) than that confirmed postnatally. The upper level of the lesion recorded on MRI was within one vertebral body in 76.2% (95% CI 65.9-85.2) of cases and within two segments in 94.2% (95% CI 90.2-97.2). CONCLUSIONS: Both ultrasound and MRI have a moderate diagnostic accuracy in identify the upper level of the lesion in fetuses with open spina bifida.


Asunto(s)
Feto/diagnóstico por imagen , Espina Bífida Quística/diagnóstico por imagen , Ultrasonografía Prenatal , Femenino , Humanos , Imagen por Resonancia Magnética , Embarazo , Diagnóstico Prenatal
13.
Acta Obstet Gynecol Scand ; 100(7): 1313-1321, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33792924

RESUMEN

INTRODUCTION: The aim of this study was to compare vaginal dinoprostone and mechanical methods for induction of labor (IOL) in pregnancies complicated by late fetal growth restriction. MATERIAL AND METHODS: Multicenter, retrospective, cohort study involving six referral centers in Italy and Spain. Inclusion criteria were pregnancies complicated by late fetal growth restriction as defined by Delphi consensus criteria. The primary outcome was the occurrence of uterine tachysystole; secondary outcomes were either cesarean delivery or operative vaginal delivery for non-reassuring fetal status, a composite score of adverse neonatal outcome and admission to neonatal intensive care unit (NICU). Univariate and multivariate logistic regression analysis was used to analyze the data. RESULTS: A total of 571 pregnancies complicated by late fetal growth restriction undergoing IOL (391 with dinoprostone and 180 with mechanical methods) were included in the analysis. The incidence of uterine tachysystole (19.2% vs. 5.6%; p = 0.001) was higher in women undergoing IOL with dinoprostone than in those undergoing IOL with mechanical methods. Similarly, the incidence of cesarean delivery or operative delivery for non-reassuring fetal status (25.6% vs. 17.2%; p = 0.027), composite adverse neonatal outcome (26.1% vs. 16.7%; p = 0.013) and NICU admission (16.9% vs. 5.6%; p < 0.001) was higher in women undergoing IOL with dinoprostone than in those undergoing IOL with mechanical methods. At logistic regression analysis, IOL with mechanical methods was associated with a significantly lower risk of uterine tachysystole (odds ratio 0.26, 95% confidence interval 0.13-0.54; p < 0.001). CONCLUSIONS: In pregnancies complicated by late fetal growth restriction, IOL with mechanical methods is associated with a lower risk of uterine tachysystole, cesarean delivery or operative delivery for non-reassuring fetal status, and adverse neonatal outcome compared with pharmacological methods.


Asunto(s)
Cateterismo/métodos , Dinoprostona/efectos adversos , Retardo del Crecimiento Fetal/terapia , Trabajo de Parto Inducido/métodos , Oxitócicos/efectos adversos , Administración Intravaginal , Adulto , Cesárea/métodos , Estudios de Cohortes , Femenino , Humanos , Recién Nacido , Italia , Embarazo , Resultado del Embarazo , España , Cateterismo Urinario/métodos
14.
Acta Obstet Gynecol Scand ; 100(1): 7-16, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32652537

RESUMEN

INTRODUCTION: Corpus callosum agenesis (ACC) is frequently diagnosed during fetal life; its prognosis depends also on additional anomalies. The additional value of fetal magnetic resonance imaging (MRI) in fetuses with "isolated" complete (cACC) and partial (pACC) agenesis of the corpus callosum on ultrasound is still debated. MATERIAL AND METHODS: We performed a systematic literature review and meta-analysis including fetuses with a prenatal diagnosis of cACC and pACC without associated structural anomalies on ultrasound, undergoing fetal MRI. The primary outcome was the rate of additional anomalies detected at fetal MRI. Further analyses assessed the effect of type of ultrasound assessment (neurosonography vs standard axial assessment), gestational age at fetal MRI and rate of postnatally detected brain anomalies. Random-effect meta-analyses of proportions were used to analyze the data. RESULTS: Fourteen studies (798 fetuses) were included. In cases with isolated cACC, 10.9% (95% CI 4.1-20.6) and 4.3% (95% CI 1.4-8.8) additional anomalies were detected by fetal MRI and postnatally, respectively. Stratifying according to the type of ultrasound assessment, the rate of associated anomalies detected only on fetal MRI was 5.7% (95% CI 0.5-16.0) with dedicated neurosonography and 18.5% (95% CI 7.8-32.4) with a standard axial assessment. In fetuses with isolated pACC, 13.4% (95% CI 4.0-27.0) and 16.2% (95% CI 5.9-30.3) additional anomalies were detected by fetal MRI or postnatally, respectively. Stratifying according to the type of ultrasound assessment, the rate of associated anomalies detected only on fetal MRI was 11.4% (95% CI 2.7-25.0) when dedicated neurosonography was performed. Cortical and posterior fossa anomalies represented the most common anomalies missed at ultrasound with both cACC and pACC. Due to the very small number of included cases, stratification according to early (<24 weeks of gestation) and late (>24 weeks) fetal MRI could not be done for either cACC or pACC. CONCLUSIONS: The rate of associated anomalies detected exclusively at fetal MRI in isolated ACC undergoing neurosonography is lower than previously reported. Cortical and posterior fossa anomalies are among the most common anomalies detected exclusively at MRI, thus confirming the crucial role of fetal MRI in determining the prognosis of these fetuses. However, some anomalies still go undetected prenatally and this should be stressed during parental counseling.


Asunto(s)
Agenesia del Cuerpo Calloso/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Diagnóstico Prenatal/métodos , Adulto , Femenino , Humanos , Embarazo , Ultrasonografía Prenatal
15.
J Perinat Med ; 49(3): 327-332, 2021 Mar 26.
Artículo en Inglés | MEDLINE | ID: mdl-33095754

RESUMEN

OBJECTIVES: Congenital cytomegalovirus (cCMV) infection can negatively affect pregnancy outcomes, but may be prevented by simple precautions. Literature suggests that gynaecologists do not always adequately inform about preventive behaviour and most pregnant women have a low-level knowledge regarding cCMV infection. The aim of this study is to evaluate knowledge and risk behaviours related to cCMV infection in an unselected group of pregnant women. METHODS: An institutional based cross-sectional study was conducted in three Maternal and Fetal Divisions in Rome between November and February 2019 on 296 pregnant women, their knowledge on cCMV was measured using six cytomegalovirus (CMV) related questions. RESULTS: Out of the 296 respondents, 59.1% had heard, read or seen information about cCMV infection. Regarding the way of transmission, 96/296 (32.4%) correctly recognize children as a potential source of the infection but only 25/296 (8.44%) knew all prevention practices, 28/296 (9.5%) of women reported that they have never performed cCMV test during pregnancy. CONCLUSIONS: The results of this survey show that knowledge on cCMV infection among pregnant women is poor. This highlights the need to improve counselling on all preventive practices for cCMV infection during perinatal care consultation.


Asunto(s)
Infecciones por Citomegalovirus , Transmisión Vertical de Enfermedad Infecciosa/prevención & control , Complicaciones Infecciosas del Embarazo , Mujeres Embarazadas , Conducta de Reducción del Riesgo , Adulto , Estudios Transversales , Citomegalovirus/aislamiento & purificación , Infecciones por Citomegalovirus/congénito , Infecciones por Citomegalovirus/prevención & control , Femenino , Conocimientos, Actitudes y Práctica en Salud , Humanos , Italia/epidemiología , Evaluación de Necesidades , Educación del Paciente como Asunto/métodos , Embarazo , Complicaciones Infecciosas del Embarazo/diagnóstico , Complicaciones Infecciosas del Embarazo/prevención & control , Complicaciones Infecciosas del Embarazo/psicología , Mujeres Embarazadas/educación , Mujeres Embarazadas/psicología
16.
Fetal Diagn Ther ; 48(6): 448-456, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34130275

RESUMEN

INTRODUCTION: The role of cerebroplacental ratio (CPR) or umbilicocerebral ratio (UCR) to predict adverse intrapartum and perinatal outcomes in pregnancies complicated by late fetal growth restriction (FGR) remains controversial. METHODS: This was a multicenter, retrospective cohort study involving 5 referral centers in Italy and Spain, including singleton pregnancies complicated by late FGR, as defined by Delphi consensus criteria, with a scan 1 week prior to delivery. The primary objective was to compare the diagnostic accuracy of the CPR and UCR for the prediction of a composite adverse outcome, defined as the presence of either an adverse intrapartum outcome (need for operative delivery/cesarean section for suspected fetal distress) or an adverse perinatal outcome (intrauterine death, Apgar score <7 at 5 min, arterial pH <7.1, base excess of >-11 mEq/mL, or neonatal intensive care unit admission). RESULTS: Median CPR absolute values (1.11 vs. 1.22, p = 0.018) and centiles (3 vs. 4, p = 0.028) were lower in pregnancies with a composite adverse outcome than in those without it. Median UCR absolute values (0.89 vs. 0.82, p = 0.018) and centiles (97 vs. 96, p = 0.028) were higher. However, the area under the curve, 95% confidence interval for predicting the composite adverse outcome showed a poor predictive value: 0.580 (0.512-0.646) for the raw absolute values of CPR and UCR, and 0.575 (0.507-0.642) for CPR and UCR centiles adjusted for gestational age. The use of dichotomized values (CPR <1, UCR >1 or CPR <5th centile, UCR >95th centile) did not improve the diagnostic accuracy. CONCLUSION: The CPR and UCR measured in the week prior delivery are of low predictive value to assess adverse intrapartum and perinatal outcomes in pregnancies with late FGR.


Asunto(s)
Cesárea , Retardo del Crecimiento Fetal , Femenino , Retardo del Crecimiento Fetal/diagnóstico por imagen , Humanos , Recién Nacido , Arteria Cerebral Media/diagnóstico por imagen , Valor Predictivo de las Pruebas , Embarazo , Resultado del Embarazo , Flujo Pulsátil , Estudios Retrospectivos , Mortinato , Ultrasonografía Prenatal , Arterias Umbilicales/diagnóstico por imagen
17.
Am J Obstet Gynecol ; 223(2): 189-203, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32067972

RESUMEN

OBJECTIVE: The aim of this systematic review and meta-analysis of randomized controlled trials was to evaluate the effect of delayed versus immediate pushing in the second stage of labor on mode of delivery and other outcomes in women with neuraxial analgesia. DATA SOURCES: The research was conducted using MEDLINE, EMBASE, Web of Sciences, Scopus, ClinicalTrial.gov, OVID, and the Cochrane Library as electronic databases, from the inception of each database to August 2019. No restrictions for language or geographic location were applied. STUDY ELIGIBILITY CRITERIA: Selection criteria included only randomized controlled trials in pregnant women randomized to either delayed or immediate pushing during the second stage of labor. STUDY APPRAISAL AND SYNTHESIS METHODS: The primary outcome was mode of delivery. The summary measures were reported as relative risk or as mean difference with 95% confidence intervals using the random effects model of DerSimonian and Laird. An I2 (Higgins I2) value of greater than 0% was used to identify heterogeneity. RESULTS: Twelve randomized controlled trials, including 5445 women with neuraxial analgesia randomized to delayed versus immediate pushing during the second stage of labor, were included in the meta-analysis. Of the 5445 women included in the meta-analysis, 2754 were randomized to the delayed pushing group and 2691 to the immediate pushing group. No significant difference between delayed and immediate pushing was found for spontaneous vaginal delivery (80.9% versus 78.3%; relative risk, 1.05; 95% confidence interval, 1.00-1.10; 12 randomized controlled trials, 5540 women), operative vaginal delivery (12.8% versus 14.6%; relative risk, 0.89; 95% confidence interval, 0.75-1.08; 11 randomized controlled trials, 5395 women), and cesarean delivery (6.9% versus 7.9%; relative risk, 0.89; 95% confidence interval, 0.73-1.07; 11 randomized controlled trials; 5395 women). Women randomized to the delayed pushing group had a significantly shorter length of active pushing (mean difference, -27.54 minutes; 95% confidence interval, -43.04 to -12.04; 7 randomized controlled trials, 4737 women) at the expense of a significantly longer overall duration of the second stage of labor (mean difference, 46.17 minutes; 95% confidence interval, 32.63-59.71; 8 studies; 4890 women). The incidence of chorioamnionitis (9.1% versus 6.6%; relative risk, 1.37, 95% confidence interval, 1.04-1.81; 1 randomized controlled trial, 2404 women) and low umbilical cord pH (2.7% versus 1.3%; relative risk, 2.00; 95% confidence interval, 1.30-3.07; 5 randomized controlled trials, 4549 women) were significantly higher in the delayed pushing group. CONCLUSION: In women with spontaneous or induced labor at term with neuraxial analgesia, delayed pushing in the second stage does not affect the mode of delivery, although it reduces the time of active pushing at the expense of a longer second stage. This prolongation of labor was associated with a higher incidence of chorioamnionitis and low umbilical cord pH. Based on these findings, delayed pushing cannot be routinely advocated for the management of the second stage.


Asunto(s)
Analgesia Epidural , Parto Obstétrico/métodos , Segundo Periodo del Trabajo de Parto/fisiología , Femenino , Humanos , Manejo del Dolor , Embarazo , Ensayos Clínicos Controlados Aleatorios como Asunto , Factores de Tiempo
18.
J Perinat Med ; 48(9): 950-958, 2020 11 26.
Artículo en Inglés | MEDLINE | ID: mdl-32975205

RESUMEN

Objectives To evaluate the strength of association between maternal and pregnancy characteristics and the risk of adverse perinatal outcomes in pregnancies with laboratory confirmed COVID-19. Methods Secondary analysis of a multinational, cohort study on all consecutive pregnant women with laboratory-confirmed COVID-19 from February 1, 2020 to April 30, 2020 from 73 centers from 22 different countries. A confirmed case of COVID-19 was defined as a positive result on real-time reverse-transcriptase-polymerase-chain-reaction (RT-PCR) assay of nasal and pharyngeal swab specimens. The primary outcome was a composite adverse fetal outcome, defined as the presence of either abortion (pregnancy loss before 22 weeks of gestations), stillbirth (intrauterine fetal death after 22 weeks of gestation), neonatal death (death of a live-born infant within the first 28 days of life), and perinatal death (either stillbirth or neonatal death). Logistic regression analysis was performed to evaluate parameters independently associated with the primary outcome. Logistic regression was reported as odds ratio (OR) with 95% confidence interval (CI). Results Mean gestational age at diagnosis was 30.6±9.5 weeks, with 8.0% of women being diagnosed in the first, 22.2% in the second and 69.8% in the third trimester of pregnancy. There were six miscarriage (2.3%), six intrauterine device (IUD) (2.3) and 5 (2.0%) neonatal deaths, with an overall rate of perinatal death of 4.2% (11/265), thus resulting into 17 cases experiencing and 226 not experiencing composite adverse fetal outcome. Neither stillbirths nor neonatal deaths had congenital anomalies found at antenatal or postnatal evaluation. Furthermore, none of the cases experiencing IUD had signs of impending demise at arterial or venous Doppler. Neonatal deaths were all considered as prematurity-related adverse events. Of the 250 live-born neonates, one (0.4%) was found positive at RT-PCR pharyngeal swabs performed after delivery. The mother was tested positive during the third trimester of pregnancy. The newborn was asymptomatic and had negative RT-PCR test after 14 days of life. At logistic regression analysis, gestational age at diagnosis (OR: 0.85, 95% CI 0.8-0.9 per week increase; p<0.001), birthweight (OR: 1.17, 95% CI 1.09-1.12.7 per 100 g decrease; p=0.012) and maternal ventilatory support, including either need for oxygen or CPAP (OR: 4.12, 95% CI 2.3-7.9; p=0.001) were independently associated with composite adverse fetal outcome. Conclusions Early gestational age at infection, maternal ventilatory supports and low birthweight are the main determinants of adverse perinatal outcomes in fetuses with maternal COVID-19 infection. Conversely, the risk of vertical transmission seems negligible.


Asunto(s)
Aborto Espontáneo/epidemiología , Betacoronavirus , Infecciones por Coronavirus/complicaciones , Muerte Fetal , Muerte Perinatal , Neumonía Viral/complicaciones , Complicaciones Infecciosas del Embarazo/virología , Betacoronavirus/genética , Betacoronavirus/aislamiento & purificación , COVID-19 , Prueba de COVID-19 , Vacunas contra la COVID-19 , Técnicas de Laboratorio Clínico , Estudios de Cohortes , Infecciones por Coronavirus/diagnóstico , Infecciones por Coronavirus/epidemiología , Femenino , Edad Gestacional , Humanos , Recién Nacido , Recien Nacido Prematuro , Transmisión Vertical de Enfermedad Infecciosa/estadística & datos numéricos , Pandemias , Neumonía Viral/diagnóstico , Neumonía Viral/epidemiología , Embarazo , Complicaciones Infecciosas del Embarazo/epidemiología , Resultado del Embarazo , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Factores de Riesgo , SARS-CoV-2
19.
Breast Cancer Res Treat ; 178(3): 485-492, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31451975

RESUMEN

PURPOSE: Potential risk of adverse obstetrical outcomes has been shown among breast cancer survivors. Therefore, the aim of this systematic review and meta-analysis was to evaluate the relationship between history of breast cancer (BC) and obstetrical outcomes. METHODS: PubMed, EMBASE, and Medline were searched from the inception of each database to April 2019. Selection criteria included prospective and retrospective cohort studies of BC pregnant survivors. The meta-analysis was performed by computing odds ratios (ORs) using both fixed and random-effects models. Quality assessment of the included studies was performed using the Newcastle-Ottawa Scale and the review was registered with PROSPERO number CRD42019127716. RESULTS: Four studies, including 1466 cases of BC survivors and 6,912,485 controls, were included. Compared with controls, a higher incidence of obstetrical complication was found in women with history of BC. The incidence of preterm birth (PTB) in the study group was 11.05% compared with 7.79% in the control group (1.68, 95% confidence interval 1.43-1.99). Breast cancer history was also associated with low birth weight (LBW) (study group: 9.26% vs. control group: 5.54%, 1.88, CI 95% 1.55-2.27), cesarean section (CS) (study group: 19.76% vs. control group 10.81%, 1.78, CI 95% 1.39-2.27), intrauterine fetal death (IUFD) (study group: 0.004% vs. control group 0.36%, of 1.25 CI 95% 0.36-4.35), and fetal anomalies (study group: 5.8% vs. control group: 4.26%, 1.45 CI 95% 1.01-2.09). CONCLUSIONS: History of BC was associated with adverse obstetrical outcomes.


Asunto(s)
Neoplasias de la Mama/epidemiología , Supervivientes de Cáncer , Resultado del Embarazo/epidemiología , Cesárea , Femenino , Humanos , Incidencia , Recién Nacido de Bajo Peso , Recién Nacido , Oportunidad Relativa , Embarazo , Complicaciones del Embarazo/epidemiología
20.
Acta Obstet Gynecol Scand ; 98(1): 11-17, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30252939

RESUMEN

INTRODUCTION: Fetal femur length below the expected value has been described as a marker of aneuploidy, skeletal dysplasia, intrauterine growth restriction and small-for-gestational-age neonate. The aim of this systematic review and meta-analysis was to evaluate the strength of association between isolated short femur length and intrauterine growth restriction or small-for-gestational-age, and perinatal adverse outcomes. MATERIAL AND METHODS: PubMed, EMBASE and Medline were searched from the inception of each database to May 2018. Selection criteria included prospective and retrospective cohort studies of singleton pregnancies between 18 and 28 weeks of gestation, with sonographic finding of isolated short femur length, without any structural chromosomal abnormality. The meta-analysis was performed by computing odds ratios using both fixed and random-effects models. Quality assessment of the included studies was performed using the Newcastle-Ottawa Scale. RESULTS: Six studies including 3078 cases of isolated short femur length (study group) and 222 303 normal femur length (control group) were included. The prevalence of intrauterine growth restriction or small-for-gestational-age in the study group was 14.2%, compared with 5.2% in the control group (odds ratio of 4.04, 95% confidence interval 3.63-4.50). Isolated short femur length was associated with a higher incidence of low birthweight (study group: 22.10% vs control group: 8.57%, odds ratio 3.24, 95% confidence interval 2.34-4.48), Apgar <7 at 5 minutes (study group: 3.98% vs control group: 1.79%, odds ratio 3.56, 95% confidence interval 1.87-6.77), preterm birth (study group: 12.16% vs control group: 8.16%, odds ratio 3.09, 95% confidence interval 1.57-6.08), fetal death (study group: 1.83% vs control group: 0.44%, odds ratio 6.48, 95% confidence interval 3.70-11.35) and neonatal intensive care unit admission (study group: 15.34% vs control group: 14.81%, odds ratio 2.11, 95% confidence interval 0.56-7.93). CONCLUSIONS: There is a significant association between isolated short femur length and intrauterine growth restriction or small-for-gestational-age and poor perinatal outcome.


Asunto(s)
Fémur/anomalías , Fémur/diagnóstico por imagen , Retardo del Crecimiento Fetal/diagnóstico por imagen , Segundo Trimestre del Embarazo , Femenino , Humanos , Embarazo , Nacimiento Prematuro/prevención & control , Estudios Prospectivos , Estudios Retrospectivos , Ultrasonografía Prenatal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA