1.
Ann Surg Oncol ; 18(2): 453-8, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-20737219

RESUMEN

BACKGROUND: Accelerated partial breast irradiation (APBI) is emerging as a valid alternative to whole-breast radiation therapy (WBRT) in breast-conserving therapy (BCT) for early-stage breast cancer. Axxent electronic brachytherapy (EBX) is a form of portable, balloon-based APBI that utilizes an electronic source of kilovoltage irradiation delivery with minimal shielding requirements. As such, EBX becomes a logical and convenient modality for delivery of intraoperative radiation therapy (IORT). We report 1-year results and clinical outcomes of a trial that utilizes EBX to deliver IORT for patients with early-stage breast cancer. METHODS: Eleven patients were enrolled on an institutional review board (IRB)-approved protocol. Inclusion criteria were patient age >45 years, unifocal tumors with infiltrating ductal or ductal carcinoma in situ (DCIS) histology, tumors ≤3 cm, and uninvolved lymph nodes. Preloaded radiation plans were used to deliver radiation prescription dose of 20 Gy to the balloon surface. RESULTS: The mean time for radiation delivery was 22 min; the total mean procedure time was 1 h 39 min. All margins of excision were negative on final pathology. At mean follow-up of 12 months, overall cosmesis was excellent in 10 of 11 patients. No infection, fat necrosis, desquamation, rib fracture or cancer recurrence has been observed. There was no evidence of fibrosis at last follow-up. CONCLUSION: IORT utilizing EBX is emerging as a feasible, well-tolerated alternative to postsurgical APBI. Further research and longer follow-up data on EBX and other IORT methods are needed to establish the clinical efficacy and safety of this treatment.


Asunto(s)
Braquiterapia , Neoplasias de la Mama/radioterapia , Carcinoma Ductal de Mama/radioterapia , Carcinoma Intraductal no Infiltrante/radioterapia , Monitoreo Intraoperatorio , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/patología , Carcinoma Ductal de Mama/cirugía , Carcinoma Intraductal no Infiltrante/patología , Carcinoma Intraductal no Infiltrante/cirugía , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Mamografía , Persona de Mediana Edad , Invasividad Neoplásica , Estadificación de Neoplasias , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
2.
Nat Clin Pract Oncol ; 6(3): 138-42, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19174776

RESUMEN

Balloon-based brachytherapy was developed to simplify the brachytherapy technique and make accelerated partial breast irradiation more accessible to patients with breast cancer who are suitable candidates for this technique. Xoft Axxent (Xoft, Inc., Sunnyvale, CA) electronic brachytherapy is a novel method of accelerated partial breast irradiation that uses an electronic source to produce X-rays. Xoft Axxent treatment does not require a high-dose-rate afterloader unit or a shielded vault, unlike other brachytherapy techniques that use iridium-192, such as MammoSite brachytherapy. Xoft Axxent is associated with the delivery of less radiation to normal tissues, and increased high radiation dose regions or 'hot spots' to the target volume compared with treatment with the MammoSite device. Further research will be needed to determine subgroups of patients who might benefit from treatment with Xoft Axxent electronic brachytherapy.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias de la Mama/radioterapia , Electrónica , Relación Dosis-Respuesta en la Radiación , Electrónica/instrumentación , Femenino , Humanos , Resultado del Tratamiento
3.
Brachytherapy ; 8(1): 14-8, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-18955018

RESUMEN

PURPOSE: A new form of partial breast irradiation (PBI), ClearPath (CP) breast brachytherapy, has been introduced. We present our results of a dosimetric comparison of MammoSite (MS) and CP PBI. METHODS AND MATERIALS: The dimensions of the CP device were reconstructed onto the MS planning CT scans for 15 previously treated patients. The mean %V(100), %V(150), %V(200) (percent of the PTV that received 100%, 150%, and 200% of the prescription dose, respectively), ipsilateral breast %V(50) (percent of the ipsilateral normal breast that received 50% of the prescription dose), ipsilateral lung %V(30) (percent of the ipsilateral lung that received 30% of the prescription dose), the heart %V(5) (percent of the heart that received 5% of the prescription dose), and the maximum skin point dose per fraction were then determined for each patient using the two methods of balloon-based PBI. RESULTS: The mean %V(100) was 96.5% vs. 96.5%, the mean %V(150) was 42.1% vs. 42.9% (p=ns), and the mean V(200) was 11.4% vs. 15.2% (p<.05) for the MS and CP methods, respectively. The mean ipsilateral breast %V(50) was 19.8% vs.18.0% (p<.05), the mean ipsilateral lung %V(30) was 3.7% vs. 2.8% (p<.05), the mean heart %V(5) was 57.0% vs. 54.3% (p<.05), and the maximum skin point dose per fraction was 312.2 and 273.6cGy (p<.05) for the MS and CP methods, respectively. CONCLUSIONS: The MS and CP methods of PBI offer comparable target volume coverage; however, the CP device achieves increased normal tissue sparing.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias de la Mama/radioterapia , Radioisótopos de Iridio/administración & dosificación , Femenino , Humanos , Radiometría , Dosificación Radioterapéutica
4.
World J Surg Oncol ; 7: 24, 2009 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-19254369

RESUMEN

BACKGROUND: In an effort to overcome the barriers to BCT, alternative methods of delivering radiation therapy have been explored. APBI allows the radiation treatment to be accomplished in one week or less. XB is a form of balloon-based APBI that uses an electronic source generated by a mobile controller unit. Investigators have also explored IORT treatment that delivers a single fraction of radiation in the operating suite at the time of surgery. METHODS: We report on the first patient treated with XB to deliver IORT. RESULTS: IORT treatment utilizing XB is feasible and can be accomplished with a total procedure time of approximately 2 hours. CONCLUSION: Further research on XB and other methods of IORT is needed to establish clinical efficacy and safety for patients with early-stage breast cancer.


Asunto(s)
Braquiterapia , Neoplasias de la Mama/radioterapia , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Electrónica , Estudios de Factibilidad , Femenino , Humanos , Periodo Intraoperatorio , Persona de Mediana Edad , Recurrencia Local de Neoplasia/prevención & control , Estadificación de Neoplasias , Dosificación Radioterapéutica , Resultado del Tratamiento
5.
Int J Radiat Oncol Biol Phys ; 71(5): 1460-4, 2008 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-18234435

RESUMEN

PURPOSE: Heterotopic ossification (HO), or abnormal bone formation, is a common sequela of total hip arthroplasty. This abnormal bone can impair joint function and must be surgically removed to restore mobility. HO can be prevented by postoperative nonsteroidal anti-inflammatory drug (NSAID) use or radiotherapy (RT). NSAIDs are associated with multiple toxicities, including gastrointestinal bleeding. Although RT has been shown to be more efficacious than NSAIDs at preventing HO, its cost-effectiveness has been questioned. METHODS AND MATERIALS: We performed an analysis of the cost of postoperative RT to the hip compared with NSAID administration, taking into account the costs of surgery for HO formation, treatment-induced morbidity, and productivity loss from missed work. The costs of RT, surgical revision, and treatment of gastrointestinal bleeding were estimated using the 2007 Medicare Fee Schedule and inpatient diagnosis-related group codes. The cost of lost wages was estimated using the 2006 median salary data from the U.S. Census Bureau. RESULTS: The cost of administering RT was estimated at $899 vs. $20 for NSAID use. After accounting for the additional costs associated with revision total hip arthroplasty and gastrointestinal bleeding, the corresponding estimated costs were $1,208 vs. $930. CONCLUSION: If the costs associated with treatment failure and treatment-induced morbidity are considered, the cost of NSAIDs approaches that of RT. Other NSAID morbidities and quality-of-life differences that are difficult to quantify add to the cost of NSAIDs. These considerations have led us to recommend RT as the preferred modality for use in prophylaxis against HO after total hip arthroplasty, even when the cost is considered.


Asunto(s)
Antiinflamatorios no Esteroideos/economía , Artroplastia de Reemplazo de Cadera/efectos adversos , Hemorragia Gastrointestinal/economía , Osificación Heterotópica/prevención & control , Radioterapia/economía , Antiinflamatorios no Esteroideos/efectos adversos , Artroplastia de Reemplazo de Cadera/economía , Análisis Costo-Beneficio , Eficiencia , Hemorragia Gastrointestinal/etiología , Costos de la Atención en Salud , Hospitalización/economía , Humanos , Medicare Assignment , Persona de Mediana Edad , Osificación Heterotópica/economía , Reoperación/economía , Estados Unidos
6.
Brachytherapy ; 7(4): 351-4, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18783991

RESUMEN

PURPOSE: This analysis was undertaken to dosimetrically compare iridium-192 high-dose-rate brachytherapy (IB) and Xoft Axxent Electronic Brachytherapy (XB; Xoft Inc., Sunnyvale, CA) in the treatment of endometrial cancer. METHODS AND MATERIALS: The planning CT scans from 11 patients previously treated with IB were used to construct hypothetical treatment plans using the source characteristics of the XB device. The mean V95, V100, and V150 (percent of the planning target volume that received 95%, 100%, and 150% of the prescription dose) were calculated. For both the bladder and rectum, the V35 (percent of the organ that received 35% of the prescription dose) and V50 (percent of the organ that received 50% of the prescription dose) were calculated for each patient using both methods of vaginal brachytherapy. RESULTS: The mean %V95 was 99.7% vs. 99.6% (p = ns) and the mean %V100 was 99.0% vs. 99.1% (p = ns) for the IB and XB methods, respectively. The mean %V150 was 35.8% vs. 58.9% (p < 0.05) for the IB and XB methods, respectively. The mean bladder %V35 was 47.7% vs. 27.4% (p < 0.05) and the mean bladder %V50 was 26.5% vs. 15.9% (p < 0.05) for the IB and XB methods, respectively. The mean rectal %V35 was 48.3% vs. 28.3% (p < 0.05) and the mean rectal %V50 was 27.8% vs. 17.0% (p < 0.05) for the IB and XB methods, respectively. CONCLUSIONS: The IB and XB methods of vaginal brachytherapy offer equivalent target volume coverage; however, the XB method allows increased sparing of the bladder and rectum.


Asunto(s)
Braquiterapia/efectos adversos , Braquiterapia/instrumentación , Neoplasias Endometriales/radioterapia , Radioisótopos de Iridio/administración & dosificación , Braquiterapia/métodos , Relación Dosis-Respuesta en la Radiación , Femenino , Humanos , Recto/efectos de la radiación , Vejiga Urinaria/efectos de la radiación
7.
Nat Clin Pract Oncol ; 4(3): 190-6, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17327859

RESUMEN

The MammoSite (Cytyc Corporation, Marlborough, MA) breast brachytherapy applicator was designed to overcome the logistic problems created by external-beam radiation therapy (EBRT) and the technical difficulties associated with multicatheter-based interstitial brachytherapy. The MammoSite catheter has been shown to treat a volume of tissue equivalent to that treated by multicatheter-based brachytherapy. Using ultrasound guidance, the MammoSite applicator can be placed using an open technique at the time of lumpectomy or post-lumpectomy. Initial results have shown favorable cosmesis and few significant side effects. NSABP B-39/RTOG 0413 randomizes patients between EBRT and partial-breast irradiation (PBI). The PBI arm consists of interstitial brachytherapy, MammoSite brachytherapy, or 3D conformal EBRT. This trial has the potential to provide a definitive answer regarding the benefits of PBI for certain subgroups of patients, and hence lead to more women undergoing breast conservation therapy.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias de la Mama/radioterapia , Mastectomía Segmentaria , Radioterapia Adyuvante/instrumentación , Braquiterapia/tendencias , Neoplasias de la Mama/cirugía , Carcinoma Ductal de Mama/radioterapia , Carcinoma Ductal de Mama/cirugía , Carcinoma Intraductal no Infiltrante , Cateterismo , Terapia Combinada , Estética , Femenino , Estudios de Seguimiento , Predicción , Humanos , Recurrencia Local de Neoplasia/epidemiología , Neoplasias Primarias Secundarias , Aceptación de la Atención de Salud , Estudios Prospectivos , Radioterapia Conformacional , Ensayos Clínicos Controlados Aleatorios como Asunto , Resultado del Tratamiento , Ultrasonografía Intervencional
8.
Int J Radiat Oncol Biol Phys ; 69(1): 25-31, 2007 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-17707264

RESUMEN

PURPOSE: To report the results of a detailed analysis of treatment failures after MammoSite breast brachytherapy for partial breast irradiation from our single-institution experience. METHODS AND MATERIALS: Between October 14, 2002 and October 23, 2006, 78 patients with early-stage breast cancer were treated with breast-conserving surgery and accelerated partial breast irradiation using the MammoSite brachytherapy applicator. We identified five treatment failures in the 70 patients with >6 months' follow-up. Pathologic data, breast imaging, and radiation treatment plans were reviewed. For in-breast failures more than 2 cm away from the original surgical bed, the doses delivered to the areas of recurrence by partial breast irradiation were calculated. RESULTS: At a median follow-up time of 26.1 months, five treatment failures were identified. There were three in-breast failures more than 2 cm away from the original surgical bed, one failure directly adjacent to the original surgical bed, and one failure in the axilla with synchronous distant metastases. The crude failure rate was 7.1% (5 of 70), and the crude local failure rate was 5.7% (4 of 70). Estimated progression-free survival at 48 months was 89.8% (standard error = 4.5%). CONCLUSIONS: Our case series of 70 patients with >6 months' follow-up and a median follow-up of 26 months is the largest single-institution report to date with detailed failure analysis associated with MammoSite brachytherapy. Our failure data emphasize the importance of patient selection when offering partial breast irradiation.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Adulto , Anciano , Braquiterapia/instrumentación , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Carcinoma in Situ/diagnóstico por imagen , Carcinoma in Situ/patología , Carcinoma in Situ/radioterapia , Carcinoma in Situ/cirugía , Carcinoma Ductal de Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/patología , Carcinoma Ductal de Mama/radioterapia , Carcinoma Ductal de Mama/cirugía , Carcinoma Lobular/diagnóstico por imagen , Carcinoma Lobular/patología , Carcinoma Lobular/radioterapia , Carcinoma Lobular/cirugía , Supervivencia sin Enfermedad , Femenino , Humanos , Mastectomía Segmentaria , Persona de Mediana Edad , Radiografía , Dosificación Radioterapéutica , Insuficiencia del Tratamiento
9.
Brachytherapy ; 6(2): 164-8, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-17434111

RESUMEN

PURPOSE: Over 20,000 patients have been treated with partial breast irradiation (PBI) using the MammoSite balloon brachytherapy applicator (IBB). Recently, a new form of balloon-based PBI, Xoft Axxent electronic brachytherapy (KVB), which uses a 50-kV x-ray source, has been introduced. This analysis was undertaken to dosimetrically compare the results of treatment using these two methods of PBI. METHODS AND MATERIALS: The study population consisted of 15 patients previously treated with IBB. The planning CT scans from these 15 patients were used to construct hypothetical treatment plans using the source characteristics of the KVB device. The plans were then compared using the dosimetric parameters discussed below. RESULTS: The mean %V(90) was 99.6% vs. 99.0% (p=nonsignificant [ns]), the mean %V(100) was 96.5% vs. 96.5%, the mean %V(150) was 41.8% vs. 59.4% (p<0.05), the mean %V(200) was 11.3% vs. 32.0% (p<0.05), and the mean %V(300) was 0.4% vs. 6.7% (p<0.05) for the IBB and KVB methods, respectively. The mean ipsilateral breast %V(50) was 19.8% vs. 13.0% (p<0.05), the mean ipsilateral lung %V(30) was 3.7% vs. 1.1% (p<0.05), and the mean heart %V(5) was 59.2% vs. 9.4% (p<0.05) for the IBB and KVB methods, respectively. CONCLUSIONS: The IBB and KVB methods of PBI offer comparable target volume coverage; however, the KVB method is associated with an increased volume of breast tissue in the high-dose regions and a decreased dose to the adjacent normal tissues.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Electrónica , Braquiterapia/instrumentación , Mama/efectos de la radiación , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Relación Dosis-Respuesta en la Radiación , Femenino , Corazón/efectos de la radiación , Irradiación de Hemicuerpo/instrumentación , Irradiación de Hemicuerpo/métodos , Humanos , Radioisótopos de Iridio/uso terapéutico , Pulmón/efectos de la radiación , Radiometría , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X , Carga Tumoral/efectos de la radiación
10.
Brachytherapy ; 5(3): 183-8, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16864070

RESUMEN

PURPOSE: Limited information is available comparing target volume and normal tissue dosimetry with the different techniques of partial breast irradiation (PBI). We present results of a dosimetric comparison of single catheter, balloon-based brachytherapy using the MammoSite catheter (BRT), 3D conformal radiation therapy (3DCRT), and intensity-modulated radiation therapy (IMRT). METHODS AND MATERIALS: Fifteen patients were treated using the BRT device. With the use of CT scans with balloons in inflated and deflated states, plans were developed for each patient using each of the methods of PBI, for a total of 45 plans. The plans were then compared using the below dosimetric parameters. RESULTS: The mean V100 was 95%, 92%, and 94% for the BRT, 3DCRT, and IMRT techniques, respectively. The mean ipsilateral breast V50 was 29%, 56%, and 46% (p < 0.0001) and the mean ipsilateral lung V30 was 5%, 7%, and 2% (p < 0.001 for IMRT vs. others) for the BRT, 3DCRT, and IMRT methods, respectively. For the 10 patients with left-sided breast tumors, the mean heart V5 was 12%, 4%, and 1% for the BRT, 3DCRT, and IMRT methods, respectively (p < 0.01). CONCLUSIONS: With increasing interest in PBI, our data may help clinicians individualize patient treatment decisions.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias de la Mama/radioterapia , Imagenología Tridimensional , Radioterapia de Intensidad Modulada/métodos , Neoplasias de la Mama/diagnóstico por imagen , Relación Dosis-Respuesta en la Radiación , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
11.
Semin Radiat Oncol ; 15(4): 235-44, 2005 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16183477

RESUMEN

Inherently, treating pancreatic adenocarcinoma with chemotherapy is limited by the marginal sensitivity of this tumor to available drugs and drug combinations. For radiotherapy, a similar therapeutic insensitivity is adversely combined with a compromised ability to escalate biologic dose within relevant target volumes because of an intertwining and surrounding matrix of dose-limiting critical normal organs and tissues. The need for effective adjuvant therapy has been intensified by an increase in the safety, applicability, and availability of surgical resection even though such resections remain largely inadequate for producing long-term disease-free survival. The need for improved treatments for locally unresectable tumors remains self-evident based on limited prognosis and the frequency of this presentation. Studies in both domains have attempted to incorporate technical advances in radiotherapy planning and delivery (3-dimensional conformal, intensity modulation) as well as the systemic promise and radiosensitizing properties of gemcitabine-based approaches. The challenges of clinical research are well reflected by the controversies resulting from available studies and the difficulties in successfully designing and executing future trials.


Asunto(s)
Adenocarcinoma/tratamiento farmacológico , Adenocarcinoma/radioterapia , Neoplasias Pancreáticas/tratamiento farmacológico , Neoplasias Pancreáticas/radioterapia , Adenocarcinoma/cirugía , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Quimioterapia Adyuvante , Ensayos Clínicos como Asunto , Humanos , Inmunoterapia , Recurrencia Local de Neoplasia , Neoplasias Pancreáticas/cirugía , Pancreaticoduodenectomía , Radioterapia Adyuvante/métodos
12.
Int J Radiat Oncol Biol Phys ; 62(2): 366-72, 2005 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-15890576

RESUMEN

PURPOSE: We present a technique to optimize the dwell times and positions of a high-dose-rate (192)Ir source using the MammoSite breast brachytherapy applicator. The surface optimization method used multiple dwell positions and optimization points to conform the 100% isodose line to the surface of the planning target volume (PTV). METHODS AND MATERIALS: The study population consisted of 20 patients treated using the MammoSite device between October 2002 and February 2004. Treatment was delivered in 10 fractions of 3.4 Gy/fraction, twice daily, with a minimum of 6 h between fractions. The treatment of each patient was planned using three optimization techniques. The dosimetric characteristics of the single-point, six-point, and surface optimization techniques were compared. RESULTS: The surface optimization technique increased the PTV coverage compared with the single- and six-point methods (mean percentage of PTV receiving 100% of the prescription dose was 94%, 85%, and 91%, respectively). The surface method, single-point, and six-point method had a mean dose homogeneity index of 0.62, 0.68, and 0.63 and a mean full width at half maximum value of 189, 190, and 192 cGy/fraction, respectively. CONCLUSION: The surface technique provided greater coverage of the PTV than did the single- and six-point methods. Using the FWHM method, the surface, single-, and six-point techniques resulted in equivalent dose homogeneity.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias de la Mama/radioterapia , Radioisótopos de Iridio/uso terapéutico , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Femenino , Humanos , Mastectomía Segmentaria , Dosificación Radioterapéutica
13.
Brachytherapy ; 4(2): 130-6, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15893266

RESUMEN

The MammoSite breast brachytherapy device was designed to overcome the potential scheduling problems associated with external beam radiotherapy (EBRT) and the technical difficulties of multi-catheter-based interstitial brachytherapy. The device consists of a silicone balloon connected to a catheter which contains an inflation channel and a port for passage of a high-dose-rate brachytherapy source. The American Brachytherapy Society and American Society of Breast Surgeons have published partial breast irradiation (PBI) patient selection guidelines. The MammoSite applicator has been shown in two dosimetric studies to treat a comparable volume to multicatheter-based interstitial implants. The MammoSite catheter can be placed at the time of lumpectomy or in a separate procedure using ultrasound guidance. Four optimization methods have been described: the single point method, the six prescription point method (RUSH Technique), the University of Southern California Norris Cancer Center Method, and the Surface Optimization Technique. An excellent or good cosmetic outcome has been reported in 80% to 93% of patients at 1 year in most studies. Cosmetic results appear highly related to skin spacing. The MammoSite applicator has been associated with early side effects comparable with traditional breast conserving therapy. A NSABP trial will randomize patients to either whole breast irradiation or PBI consisting of interstitial brachytherapy, MammoSite brachytherapy, or 3D conformal radiation.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias de la Mama/radioterapia , Diseño de Equipo , Estudios de Evaluación como Asunto , Femenino , Humanos , Persona de Mediana Edad , Dosificación Radioterapéutica , Resultado del Tratamiento
14.
Brachytherapy ; 4(3): 236-40, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-16182225

RESUMEN

PURPOSE: In vaginal intracavitary brachytherapy using cylindrical applicators, it is common to prescribe dose to a depth of 0.5 cm to cover the lymphatic channels. However, the actual depth of the lymphatics within the vaginal wall has never been determined. In this study, we examined the depth distribution of lymphatics lying beneath the mucosal surface of the vagina. METHODS AND MATERIALS: Between January 24, 1996 and October 27, 2003, 31 patients underwent full-thickness vaginal biopsy or partial resection for both benign and malignant disease. In addition, in February 2004, vaginal samples from two autopsy specimens were stretched and pinned for formalin fixation and slide production. Forty-five slides of both stretched and nonstretched vaginal tissue were stained with D2-40 monoclonal antibody lymphatic endothelium marker. The percentages of lymphatics located within 1, 1-2, 2-3, and 3-4mm were calculated for all slides. RESULTS: For the nonstretched samples, the percentages of lymphatics located within 1, 1-2, 2-3, and 3-4mm were 50.5%, 30.7%, 11.9%, and 6.9%, respectively. For the stretched samples, the percentages of lymphatics located within 1, 1-2, 2-3, and 3-4mm were 44.0%, 33.8%, 18.8%, and 3.4%, respectively. The differences of lymphatic percentages within and superficial to 1mm (p=0.60), 1-2mm (p=0.85), 2-3mm (p=0.89), and 3-4mm (p=0.99) were not statistically significant between the stretched and nonstretched states. CONCLUSIONS: Our results show that approximately 95% of vaginal lymphatic channels are located within a 3mm depth from the vaginal surface. This suggests that dose prescribed to a depth less than 0.5 cm may be adequate and could permit treatment with less normal tissue toxicity in certain clinical situations.


Asunto(s)
Braquiterapia/métodos , Neoplasias Endometriales/patología , Neoplasias Endometriales/radioterapia , Ganglios Linfáticos/patología , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias Vaginales/patología , Neoplasias Vaginales/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Persona de Mediana Edad , Dosificación Radioterapéutica , Resultado del Tratamiento
15.
Int J Radiat Oncol Biol Phys ; 59(2): 469-74, 2004 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-15145164

RESUMEN

PURPOSE: Limited information has been reported on the dosimetry achieved with the MammoSite breast brachytherapy applicator. We present our results regarding the volume of treatment and a comparison of a single prescription point, single dwell position optimization technique with a six prescription point, multiple dwell position method. METHODS AND MATERIALS: Between October 14, 2002 and February 28, 2003, 21 patients with early-stage breast cancer were treated using the MammoSite device. The treatment was delivered in 10 fractions of 3.4 Gy/fraction, b.i.d., with a minimum of 6 hours between the daily fractions. CT of the lumpectomy cavity was obtained both with and without the inflated balloon. A planning target volume was constructed using a three-dimensional planning system. A three-dimensional expansion of the balloon surface was performed using the chest wall and skin as limiting structures. The volume of the inflated balloon was removed from this volume, and the volume of tissue treated in each patient was determined. A sequential expansion in 1-mm increments around the empty lumpectomy cavity was performed until the closest equivalent volume to the planning target volume was obtained. The treatment for the patients in this study was planned using both a single prescription point, single dwell position optimization technique and a six-prescription point, multiple dwell position technique. The single prescription point method has been described in a previous publication. The six-prescription point method used six points placed 1 cm from the balloon surface. Four points are in a plane transverse to the balloon axis perpendicular to the axis of the catheter, and two points are placed along the axis of the catheter. The prescription points along the catheter axis are used to compensate for the decreased dose coverage owing to anisotropy dose distribution of the source. The Nucletron HDR Plato Brachytherapy planning system was used to optimize the source positions and dwell times. RESULTS: The volume of breast tissue treated by the MammoSite device was equal to the volume encompassed by a mean 1.6-cm (SD, 0.1) margin around the empty lumpectomy cavity. Compared with the single prescription point optimization method, the six prescription point method provided better dose coverage, with a mean percentage of volume receiving 90% of the prescription dose of 97.2% (SD = 2.1) vs. 89.5% (SD = 4.6) for the single-point method. The mean percentage of volume receiving 100% of the prescription dose was 88.9% (SD = 3.3) for the six-point method vs. 77.6% (SD = 6.1) for the single-point method. However, compared with the single-point method, the six-point optimization method resulted in treatment that was less uniform, with a mean dose homogeneity index of 0.62 (SD =.07) vs. 0.66 (SD =.08) for the single-point method. CONCLUSION: The volume of normal breast tissue treated by the MammoSite device is comparable to other methods of interstitial brachytherapy that treat a 1-2-cm margin of tissue around the excision cavity. The six-prescription point, multiple dwell position method improved dose coverage with a slight decrease in dose homogeneity. The six-point method offers greater reliability of dose coverage compared with the single-point method by providing an increased number of reference points.


Asunto(s)
Braquiterapia/instrumentación , Neoplasias de la Mama/radioterapia , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Fraccionamiento de la Dosis de Radiación , Femenino , Humanos , Mastectomía Segmentaria , Persona de Mediana Edad
16.
Med Phys ; 31(5): 1219-24, 2004 May.
Artículo en Inglés | MEDLINE | ID: mdl-15191312

RESUMEN

Phantom measurements and Monte Carlo calculations have been performed for the purpose of characterizing the dose perturbation caused by radiographic contrast inside the MammoSite breast brachytherapy applicator. Specifically, the dose perturbation is quantified as a heterogeneity correction factor (HCF) for various balloon radii and contrast concentration levels. The dose perturbation is larger for larger balloon radii and higher contrast concentrations. Based on a validated Monte Carlo simulation, the calculated HCF values are 0.99 for a 2 cm radius balloon and 0.98 for a 3 cm radius balloon at 6% contrast concentration levels, and 0.89 and 0.87 for 2 and 3 cm radius balloons, respectively, at 100% contrast concentrations. For a typical implanted balloon radius of 2.4 cm, the HCF values decrease from 0.99 at 6% contrast concentration to 0.90 at 100% contrast concentration. For balloons implanted in patients at our institution, the mean HCF is 0.99, corresponding to a dose reduction of approximately 1%. The contrast effect results in a systematic reduction in the delivered dose, therefore the minimal amount of radiographic contrast necessary should be used.


Asunto(s)
Braquiterapia/métodos , Cateterismo/métodos , Medios de Contraste , Radiometría/métodos , Angiografía/métodos , Humanos , Fantasmas de Imagen , Dosificación Radioterapéutica
18.
Radiat Oncol ; 5: 67, 2010 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-20646289

RESUMEN

BACKGROUND: A modified form of high dose rate (HDR) brachytherapy has been developed called Axxent Electronic Brachytherapy (EBT). EBT uses a kilovolt X-ray source and does not require treatment in a shielded vault or a HDR afterloader unit. A multi-center clinical study was carried out to evaluate the success of treatment delivery, safety and toxicity of EBT in patients with endometrial cancer. METHODS: A total of 15 patients with stage I or II endometrial cancer were enrolled at 5 sites. Patients were treated with vaginal EBT alone or in combination with external beam radiation. RESULTS: The prescribed doses of EBT were successfully delivered in all 15 patients. From the first fraction through 3 months follow-up, there were 4 CTC Grade 1 adverse events and 2 CTC Grade II adverse events reported that were EBT related. The mild events reported were dysuria, vaginal dryness, mucosal atrophy, and rectal bleeding. The moderate treatment related adverse events included dysuria, and vaginal pain. No Grade III or IV adverse events were reported. The EBT system performed well and was associated with limited acute toxicities. CONCLUSIONS: EBT shows acute results similar to HDR brachytherapy. Additional research is needed to further assess the clinical efficacy and safety of EBT in the treatment of endometrial cancer.


Asunto(s)
Braquiterapia/métodos , Neoplasias Endometriales/radioterapia , Adulto , Anciano , Femenino , Humanos , Persona de Mediana Edad , Estadificación de Neoplasias
19.
Int J Radiat Oncol Biol Phys ; 78(1): 104-10, 2010 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-20004529

RESUMEN

PURPOSE: For patients with left-sided breast cancers, radiation treatment to the intact breast results in high doses to significant volumes of the heart, increasing the risk of cardiac morbidity, particularly in women with unfavorable cardiac anatomy. We compare helical tomotherapy (TOMO) and inverse planned intensity modulated radiation therapy (IMRT) with three-dimensional conformal radiotherapy using opposed tangents (3D-CRT) for reductions in cardiac volumes receiving high doses. METHODS AND MATERIALS: Fifteen patients with left-sided breast cancers and unfavorable cardiac anatomy, determined by a maximum heart depth (MHD) of >or=1.0 cm within the tangent fields, were planned for TOMO and IMRT with five to seven beam angles, in addition to 3D-CRT. The volumes of heart and left ventricle receiving >or=35 Gy (V35) were compared for the plans, as were the mean doses to the contralateral breast and the volume receiving >or=20 Gy (V20) for the ipsilateral lung. RESULTS: The mean MHD was 1.7 cm, and a significant correlation was observed between MHD and both heart and left ventricle V35. The V35s for IMRT (0.7%) and TOMO (0.5%) were significantly lower than for 3D-CRT (3.6%). The V20 for IMRT (22%) was significantly higher than for 3D-CRT (15%) or TOMO (18%), but the contralateral breast mean dose for TOMO (2.48 Gy) was significantly higher than for 3D-CRT (0.93 Gy) or IMRT (1.38 Gy). CONCLUSIONS: Both TOMO and IMRT can significantly reduce cardiac doses, with modest increases in dose to other tissues in left-sided breast cancer patients with unfavorable cardiac anatomy.


Asunto(s)
Neoplasias de la Mama/radioterapia , Corazón/efectos de la radiación , Traumatismos por Radiación/prevención & control , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Femenino , Corazón/anatomía & histología , Corazón/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/efectos de la radiación , Humanos , Radiografía , Dosificación Radioterapéutica , Radioterapia Conformacional/métodos
20.
Am J Clin Oncol ; 33(4): 327-35, 2010 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-20375833

RESUMEN

OBJECTIVES: Phase IV study evaluated the safety and device performance of an electronic brachytherapy system (Axxent Electronic Brachytherapy System) as adjuvant therapy for early-stage breast cancer. METHODS: Patients were > or =50 years of age and had completely resected invasive ductal carcinoma or ductal carcinoma in situ (<2.0 cm), with N0 M0 and negative microscopic margins of > or =1 mm. The balloon applicator was placed in a closed cavity with a balloon surface to skin distance of > or =7 mm. The prescribed dose was 3.4 Gy/fraction prescribed to 1 cm beyond the balloon surface twice daily (BID) for 10 fractions. RESULTS: Of 65 patients consented, 21 (32%) were not eligible for treatment, and 44 (68%) were treated, with 6-months follow-up in 43 and 1-year follow-up in 36. The prescribed radiation treatment was successfully delivered in 42/44 (95.4%) patients; one was unsuccessful due to a controller issue and the other declined the final fraction following a balloon deflation. Side effects were as anticipated and generally manageable. Four CTCAE v3 grade 3 toxicities were reported: blistering (1), breast tenderness (1), and moist desquamation (2); all have resolved. The most common grade 2 toxicity was erythema. There were no device-related serious adverse events. CONCLUSIONS: Early experience demonstrates that the electronic brachytherapy system performed as expected. Electronic brachytherapy has similar acute toxicity profiles to other high dose rate approaches for accelerated partial breast irradiation and offers the convenience of having the treatment in an unshielded room.


Asunto(s)
Braquiterapia/métodos , Neoplasias de la Mama/radioterapia , Anciano , Braquiterapia/efectos adversos , Braquiterapia/instrumentación , Mama/patología , Mama/efectos de la radiación , Neoplasias de la Mama/patología , Electrónica , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Estadificación de Neoplasias , Dosificación Radioterapéutica , Seguridad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA