Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Pediatr Cardiol ; 42(2): 361-369, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33165623

RESUMEN

Atrial flutter (AFL) in children and adolescents beyond the neonatal period in the absence of any underlying myocardial disease ("lone AFL") is rare and data is limited. Our study aims to present clinical and electrophysiological data of presumed "lone AFL" in pediatric patients and discuss the role of endomyocardial biopsy (EMB) and further follow-up. Since July 2005, eight consecutive patients at a median age of 12.7 (range 10.4-16.7) years presenting with presumed "lone AFL" after negative non-invasive diagnostic work-up had electrophysiological study (EPS) and induction of cavotricuspid isthmus (CTI) conduction block by radiofrequency (RF) current application. In 6/8 patients EMB could be taken. Induction of CTI conduction block was achieved in all patients. Histopathological examination of EMB from the right ventricular septum exhibited myocarditis or cardiomyopathy in 4/6 patients, respectively. During follow-up, 4/8 patients had recurrent arrhythmia (AFL n = 2, wide QRS complex tachycardia n = 1, monomorphic premature ventricular contractions n = 1) after the ablation procedure. 3/4 patients with recurrent arrhythmia had pathological EMB results. The remaining patient with recurrent arrhythmia had a negative EMB but was diagnosed with Brugada syndrome during further follow-up. Taking together results of EMB and further clinical course, only 3/8 patients finally turned out to have true "lone AFL". Our study demonstrates that true "lone AFL" in children and adolescents is rare. EMB and clinical course revealed an underlying cardiac pathology in the majority of the individuals studied. EMB was very helpful in order to timely establish the diagnosis of myocarditis or cardiomyopathy.


Asunto(s)
Aleteo Atrial/diagnóstico , Adolescente , Aleteo Atrial/etiología , Aleteo Atrial/terapia , Ablación por Catéter , Niño , Fenómenos Electrofisiológicos , Femenino , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento
2.
Pediatr Cardiol ; 42(3): 685-691, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33454819

RESUMEN

Transseptal puncture (TSP) is a standard procedure to obtain access to the left heart. However, data on TSP in infants and children particularly with congenital heart defects (CHD) is sparse. Safety and efficacy of TSP in infants and children < 18 years with normal cardiac anatomy and with CHD were assessed. 327 TSP were performed in a total of 300 individuals < 18 years from 10/2002 to 09/2018 in our tertiary pediatric referral center. Median age at TSP was 11.9 years (IQR 7.8-15; range: first day of life to 17.9 years). 13 subjects were < 1 year. Median body weight was 43.8 kg (IQR 26.9-60; range: 1.8-121 kg). CHD was present in 28/327 (8.6%) procedures. TSP could be successfully performed in 323/327 (98.8%) procedures and was abandoned in 4 procedures due to imminent or incurred complications. Major complications occurred in 4 patients. 3 of these 4 subjects were ≤ 1 year of age and required TSP for enlargement of a restrictive atrial septal defect in complex CHD. Two of these babies deceased within 48 h after TSP attempt. The third baby needed urgent surgery in the cath lab. Pericardial effusion requiring drainage was noted in the forth patient (> 1 year) who was discharged well later. Minor complications emerged in 5 patients. The youngest of these individuals (0.3 years, 5.8 kg) developed small pericardial effusion after anterograde ballon valvuloplasty for critical aortic stenosis. The remaining 4/5 patients developed small pericardial effusion after ablation of a left-sided accessory atrioventricular pathway (6.1-12.2 years, 15.6-34.0 kg). TSP for access to the left heart was safe and effective in children and adolescents > 1 year of age. However, TSP was a high-risk procedure in small infants with a restrictive interatrial septum with need for enlargement of interatrial communication.


Asunto(s)
Tabique Interatrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Cardiopatías Congénitas/cirugía , Punciones/métodos , Adolescente , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Estudios de Casos y Controles , Niño , Preescolar , Femenino , Atrios Cardíacos/cirugía , Humanos , Lactante , Recién Nacido , Masculino , Punciones/efectos adversos , Estudios Retrospectivos
3.
Harm Reduct J ; 18(1): 122, 2021 12 07.
Artículo en Inglés | MEDLINE | ID: mdl-34872586

RESUMEN

BACKGROUND: Worldwide, alcohol-related road traffic accidents represent a major avoidable health risk. The aim of this study was to evaluate the accuracy of self-estimating the degree of acute alcohol intoxication regarding the legal driving limit, and to identify risk factors for misjudgement. METHODS: In this prospective randomised controlled crossover trial, 90 social drinkers (mean age 23.9 ± 3.5 years, 50% female) consumed either beer or wine. Study group subjects were made aware when exceeding the legal driving limit (BrAC = 0.05%). Controls received no information about their BrAC. For crossover, beer or wine were consumed in the opposite order. RESULTS: 39-53% of all participants exceeded the legal driving limit whilst under the impression to be still permitted to drive. Self-estimation was significantly more accurate on study day 2 (p = 0.009). Increasing BrAC positively correlated with self-estimation inaccuracy, which was reproducible during crossover. Multiple regression analysis revealed fast drinking and higher alcohol levels as independent risk factors for inaccurate self-estimation. CONCLUSIONS: Social drinkers are commonly unaware of exceeding the legal driving limit when consuming alcohol. Self-estimating alcohol intoxication can be improved through awareness. Dedicated awareness programs, social media campaigns and government advice communications should be utilised to address this avoidable hazard. Trial registration The trial was registered prospectively at the Witten/Herdecke University Ethics Committee (trial registration number 140/2016 on 04/11/2016) and at the DRKS-German Clinical Trials Register (trial registration number DRKS00015285 on 08/22/2018-Retrospectively registered). Trial protocol can be accessed online.


Asunto(s)
Intoxicación Alcohólica , Conducción de Automóvil , Adulto , Consumo de Bebidas Alcohólicas , Femenino , Humanos , Masculino , Percepción , Estudios Prospectivos , Adulto Joven
4.
Pediatr Cardiol ; 37(3): 459-64, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26538211

RESUMEN

Experience of catheter ablation of pediatric focal atrial tachycardia (FAT) is still limited. There are data which were gathered prior to the introduction of modern 3D mapping and navigation systems into the clinical routine. Accordingly, procedures were associated with significant fluoroscopy and low success rates. The aim of this study was to present clinical and electrophysiological details of catheter ablation of pediatric FAT using modern mapping systems. Since March 2003, 17 consecutive patients <20 years underwent electrophysiological study (EPS) for FAT using the NavX(®) system (n = 7), the non-contact mapping system (n = 6) or the LocaLisa(®) system (n = 4), respectively. Radiofrequency was the primary energy source; cryoablation was performed in selected patients with a focus close to the AV node. In 16 patients, a total number of 19 atrial foci (right-sided n = 13, left-sided n = 6) could be targeted. In the remaining patient, FAT was not present/inducible during EPS. On an intention-to-treat basis, acute success was achieved in 14/16 patients (87.5 %) with a median number of 11 (1-31) energy applications. Ablation was unsuccessful in two patients due to an epicardial location of a right atrial focus (n = 1) and a focus close to the His bundle (n = 1), respectively. Median procedure time was 210 (84-332) min, and median fluoroscopy time was 13.1 (4.5-22.5) min. In pediatric patients with FAT, 3D mapping and catheter ablation provided improved clinical quality of care. Catheter ablation may be considered early in the course of treatment of this tachyarrhythmia in symptomatic patients.


Asunto(s)
Ablación por Catéter/métodos , Criocirugía/métodos , Atrios Cardíacos/cirugía , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/cirugía , Adolescente , Niño , Preescolar , Electrocardiografía , Femenino , Estudios de Seguimiento , Alemania , Humanos , Masculino , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
5.
Sci Rep ; 12(1): 8940, 2022 05 27.
Artículo en Inglés | MEDLINE | ID: mdl-35624305

RESUMEN

Head development is a surrogate for brain development in infants and is related to neurocognitive outcome. There is only limited knowledge on early extra-uterine head shape and size assessment in very preterm infants. Here, 26 very preterm infants with a mean gestational age of 29.1 ± 2.2 weeks and a mean birth weight of 1273.8 ± 427.7 g underwent serial stereophotogrammetric 3D head imaging in weekly intervals from birth to term-equivalent age. The main outcome was the longitudinal assessment of the 'physiological' preterm head development with cephalometric size (head circumference, cranial volume) and shape parameters (cranial index, cranial vault asymmetry index) according to chronological and postmenstrual age (PMA). Potential clinical risk factors for the development of an abnormal low cranial index (dolichocephaly) were analysed. In serial measurements of 26 infants, the estimated head volume (95% confidence interval) increased from 244 (226-263) cm3 at 28 weeks PMA to 705 (688-721) cm3 at 40 weeks PMA. Moderate or severe dolichocephaly occurred in 21/26 infants (80.8%). Cranial index decreased over time (72.4%; 70.7-74 95% confidence interval). Brachycephaly and plagiocephaly were uncommon. No risk factors for severe dolichocephaly were identified. Our study shows that early detection of head shape and size anomalies utilizing 3D stereophotogrammetry is feasible and safe even in very preterm infants < 1500 g and/or < 32 weeks. 3D stereophotogrammetry could be used for timely identification of infants at risk for head shape anomalies. No specific risk factors for head shape anomalies were identified, especially not mode and duration of respiratory support.


Asunto(s)
Craneosinostosis , Enfermedades del Prematuro , Craneosinostosis/diagnóstico , Femenino , Edad Gestacional , Humanos , Lactante , Recién Nacido , Recien Nacido Prematuro , Recién Nacido de muy Bajo Peso , Fotogrametría
6.
J Interv Card Electrophysiol ; 54(2): 151-159, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30255451

RESUMEN

BACKGROUND: Implantable cardioverter defibrillators (ICD) protect from sudden cardiac death (SCD). In infants and young children, ICD implantation and programming is challenging due to small body size, elevated heart rates, and high physical activity. PURPOSE: We report our experience applying a non-transvenous ICD (NT-ICD) system to infants and children < 12 years of age and < 45-kg body weight. METHODS: Between 07/2004 and 07/2016, NT-ICD had been implanted in 36 patients. Nine out of 36 patients (25%) had NT-ICD implantation for primary and 27/36 (75%) for secondary prevention. Underlying diseases included inherited primary electrical arrhythmogenic diseases (n = 26; 72%), cardiomyopathies (n = 8; 22%), and congenital heart defects (n = 2; 6%). The median (interquartile range) age at implantation was 6 (1.9-8.4) years, and the median body weight was 21.7 (11.2-26.8) kg. Three different NT-ICD implantation techniques had been applied over time: (1) abdominal device/subcutaneous shock coil, (2) abdominal device/pleural shock coil, and (3) subcardiac device/pleural shock coil. RESULTS: During median follow-up of 5.2 (2.7-7.2) years, appropriate ICD discharges were documented in 12 (33.3%) and inappropriate shocks in 4 patients (11.1%). In 12/36 individuals (33.3%), a total of 25 surgical revisions were required due to NT-ICD malfunction. Eighteen out of 25 (72%) surgical revisions were necessary in patients with subcutaneous shock coil/abdominal device position. Surgical revisions (3/25, 12%) were significantly reduced (p < 0.001) after modifying the implantation technique to subcardiac device/pleural shock coil. CONCLUSIONS: NT-ICD was safe and effective in infants and young children. Appropriate ICD discharges occurred in a considerable number of patients. After modifying the implantation technique, the need for surgical revision could significantly be decreased.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/métodos , Factores de Edad , Niño , Preescolar , Estudios de Cohortes , Cardioversión Eléctrica/instrumentación , Diseño de Equipo , Seguridad de Equipos , Femenino , Estudios de Seguimiento , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/cirugía , Humanos , Lactante , Estimación de Kaplan-Meier , Masculino , Seguridad del Paciente/estadística & datos numéricos , Estudios Retrospectivos , Medición de Riesgo , Factores Sexuales , Tasa de Supervivencia , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA