Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Bases de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
J Endovasc Ther ; : 15266028231215212, 2023 Dec 06.
Artículo en Inglés | MEDLINE | ID: mdl-38053508

RESUMEN

PURPOSE: to assess the safety and efficacy of APERTO-Paclitaxel-coated balloon angioplasty versus standard angioplasty for the treatment of dysfunctional hemodialysis shunts and native arteriovenous fistulae. METHODS: consecutive patients with dysfunctional dialysis related to underlying efferent vein stenosis were included and randomized 1:1 to either APERTO-paclitaxel drug-coated balloon (study arm) or standard percutaneous transluminal angioplasty (control arm). Primary endpoint is time from treatment until dialysis access dysfunction according to standardized Kidney Disease Outcomes Quality Initiative (KDOQI)-guidelines and assessed by Kaplan-Meier survival curves and tested for significance with log-rank analysis. Secondary endpoints include device, technical, and clinical success of the index angioplasty procedure. RESULTS: The study included 103 patients (n=51 study-group) with a de novo (n=33) dysfunctional native arteriovenous fistula (n=79) in the forearm (n=60). The majority of included patients were male with a mean age of 69.8 years, presenting with a dysfunctioning autologous arteriovenous fistula in the forearm. Device-related complications did not occur in any of the included patients. Functional hemodialysis access without need for re-intervention at 1 year after index procedure was found in n=10 (19.6%) and n=5 (9.6%) of patients treated with, respectively, paclitaxel drug-coated balloon and percutaneous transluminal angioplasty (p=0.612). A nonsignificant benefit of paclitaxel drug-coated balloon (n=5; 25%) over percutaneous transluminal angioplasty (n=1; 11%) was found (p=0.953) in de novo lesions in autologous fistulas. CONCLUSION: APERTO-paclitaxel drug-coated balloon is a safe balloon catheter to manage dysfunctional hemodialysis access; however, longer period of adequate hemodialysis circuit functioning after endovascular index stenosis treatment, using APERTO-paclitaxel drug-coated balloon versus percutaneous transluminal angioplasty could not be demonstrated. CLINICAL IMPACT: APERTO-paclitaxel drug-coated balloon catheter is a safe device to manage dysfunctional hemodialysis access. Compared to conventional angioplasty balloon, the APERTO drug-coated balloon will not result in longer period of adequate hemodialysis circuit functioning. A non-significant benefit of APERTO drug-coated balloon was found in de novo lesions in autologous fistulas.

2.
J Endovasc Ther ; 13(6): 770-4, 2006 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-17154709

RESUMEN

PURPOSE: To present a case of successful emergency endovascular repair of a ruptured, probably mycotic, thoracoabdominal aortic aneurysm (TAAA) with a stent-graft deliberately covering the celiac axis. CASE REPORT: A 79-year-old woman with significant pulmonary comorbidity presented with a ruptured mycotic TAAA extending to the celiac axis. The aneurysm was excluded with a stent-graft soaked in rifampicin and deployed to deliberately occlude the celiac axis for effective distal sealing and fixation. The patient recovered well and was prescribed antibiotic treatment for up to 6 months. CONCLUSION: Endovascular repair of a ruptured TAAA may be a life-saving option. In emergency situations when poor distal anatomy is present, covering the celiac artery with the stent-graft should be considered.


Asunto(s)
Aneurisma Infectado/terapia , Angioplastia de Balón/métodos , Aneurisma de la Aorta Abdominal/terapia , Aneurisma de la Aorta Torácica/terapia , Rotura de la Aorta/terapia , Implantación de Prótesis Vascular/métodos , Arteria Celíaca , Stents , Dolor Abdominal/etiología , Anciano , Aneurisma Infectado/complicaciones , Aneurisma Infectado/diagnóstico por imagen , Angiografía , Antibacterianos/uso terapéutico , Antibióticos Antituberculosos , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Rotura de la Aorta/complicaciones , Rotura de la Aorta/diagnóstico por imagen , Diarrea/etiología , Urgencias Médicas , Fatiga/etiología , Femenino , Fiebre/etiología , Humanos , Selección de Paciente , Diseño de Prótesis , Rifampin , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA