1.
N Engl J Med ; 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38767244

RESUMEN

BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (ICD) is associated with fewer lead-related complications than a transvenous ICD; however, the subcutaneous ICD cannot provide bradycardia and antitachycardia pacing. Whether a modular pacing-defibrillator system comprising a leadless pacemaker in wireless communication with a subcutaneous ICD to provide antitachycardia and bradycardia pacing is safe remains unknown. METHODS: We conducted a multinational, single-group study that enrolled patients at risk for sudden death from ventricular arrhythmias and followed them for 6 months after implantation of a modular pacemaker-defibrillator system. The safety end point was freedom from leadless pacemaker-related major complications, evaluated against a performance goal of 86%. The two primary performance end points were successful communication between the pacemaker and the ICD (performance goal, 88%) and a pacing threshold of up to 2.0 V at a 0.4-msec pulse width (performance goal, 80%). RESULTS: We enrolled 293 patients, 162 of whom were in the 6-month end-point cohort and 151 of whom completed the 6-month follow-up period. The mean age of the patients was 60 years, 16.7% were women, and the mean (±SD) left ventricular ejection fraction was 33.1±12.6%. The percentage of patients who were free from leadless pacemaker-related major complications was 97.5%, which exceeded the prespecified performance goal. Wireless-device communication was successful in 98.8% of communication tests, which exceeded the prespecified goal. Of 151 patients, 147 (97.4%) had pacing thresholds of 2.0 V or less, which exceeded the prespecified goal. The percentage of episodes of arrhythmia that were successfully terminated by antitachycardia pacing was 61.3%, and there were no episodes for which antitachycardia pacing was not delivered owing to communication failure. Of 162 patients, 8 died (4.9%); none of the deaths were deemed to be related to arrhythmias or the implantation procedure. CONCLUSIONS: The leadless pacemaker in wireless communication with a subcutaneous ICD exceeded performance goals for freedom from major complications related to the leadless pacemaker, for communication between the leadless pacemaker and subcutaneous ICD, and for the percentage of patients with a pacing threshold up to 2.0 V at a 0.4-msec pulse width at 6 months. (Funded by Boston Scientific; MODULAR ATP ClinicalTrials.gov NCT04798768.).

2.
N Engl J Med ; 388(25): 2360-2370, 2023 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37212442

RESUMEN

BACKGROUND: Single-chamber ventricular leadless pacemakers do not support atrial pacing or consistent atrioventricular synchrony. A dual-chamber leadless pacemaker system consisting of two devices implanted percutaneously, one in the right atrium and one in the right ventricle, would make leadless pacemaker therapy a treatment option for a wider range of indications. METHODS: We conducted a prospective, multicenter, single-group study to evaluate the safety and performance of a dual-chamber leadless pacemaker system. Patients with a conventional indication for dual-chamber pacing were eligible for participation. The primary safety end point was freedom from complications (i.e., device- or procedure-related serious adverse events) at 90 days. The first primary performance end point was a combination of adequate atrial capture threshold and sensing amplitude at 3 months. The second primary performance end point was at least 70% atrioventricular synchrony at 3 months while the patient was sitting. RESULTS: Among the 300 patients enrolled, 190 (63.3%) had sinus-node dysfunction and 100 (33.3%) had atrioventricular block as the primary pacing indication. The implantation procedure was successful (i.e., two functioning leadless pacemakers were implanted and had established implant-to-implant communication) in 295 patients (98.3%). A total of 35 device- or procedure-related serious adverse events occurred in 29 patients. The primary safety end point was met in 271 patients (90.3%; 95% confidence interval [CI], 87.0 to 93.7), which exceeded the performance goal of 78% (P<0.001). The first primary performance end point was met in 90.2% of the patients (95% CI, 86.8 to 93.6), which exceeded the performance goal of 82.5% (P<0.001). The mean (±SD) atrial capture threshold was 0.82±0.70 V, and the mean P-wave amplitude was 3.58±1.88 mV. Of the 21 patients (7%) with a P-wave amplitude of less than 1.0 mV, none required device revision for inadequate sensing. At least 70% atrioventricular synchrony was achieved in 97.3% of the patients (95% CI, 95.4 to 99.3), which exceeded the performance goal of 83% (P<0.001). CONCLUSIONS: The dual-chamber leadless pacemaker system met the primary safety end point and provided atrial pacing and reliable atrioventricular synchrony for 3 months after implantation. (Funded by Abbott Medical; Aveir DR i2i ClinicalTrials.gov number, NCT05252702.).


Asunto(s)
Arritmias Cardíacas , Estimulación Cardíaca Artificial , Marcapaso Artificial , Humanos , Fibrilación Atrial/terapia , Fibrilación Atrial/etiología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estudios de Seguimiento , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Arritmias Cardíacas/terapia
3.
Circulation ; 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38973458

RESUMEN

BACKGROUND: A dual-chamber leadless pacemaker system has been designed for AV synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The AV synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of AV synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between AV synchrony and i2i success, posture/activity, implantation indication, AV event, and heart rate were calculated. RESULTS: In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean AV synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrium-to-ventricle i2i (94%) and ventricle-to-atrium i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. AV synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, AV paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS: This dual-chamber leadless pacemaker system demonstrated AV synchrony in 98% of evaluable beats at 3 months after implantation. AV synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.

4.
J Cardiovasc Electrophysiol ; 34(2): 348-355, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36448428

RESUMEN

INTRODUCTION: Early and safe ambulation can facilitate same-day discharge (SDD) following catheter ablation, which can reduce resource utilization and healthcare costs and improve patient satisfaction. This study evaluated procedure success and safety of the VASCADE MVP venous vascular closure system in patients with atrial fibrillation (AF). METHODS: The AMBULATE SDD Registry is a two-stage series of postmarket studies in patients with paroxysmal or persistent AF undergoing catheter ablation followed by femoral venous access-site closure with VASCADE MVP. Efficacy endpoints included SDD success, defined as the proportion of patients discharged the same day who did not require next-day hospital intervention for procedure/access site-related complications, and access site sustained success within 15 days of the procedure. RESULTS: Overall, 354 patients were included in the pooled study population, 151 (42.7%) treated for paroxysmal AF and 203 (57.3%) for persistent AF. SDD was achieved in 323 patients (91.2%) and, of these, 320 (99.1%) did not require subsequent hospital intervention based on all study performance outcomes. Nearly all patients (350 of 354; 98.9%) achieved total study success, with no subsequent hospital intervention required. No major access-site complications were recorded. Patients who had SDD were more likely to report procedure satisfaction than patients who stayed overnight. CONCLUSION: In this study, 99.7% of patients achieving SDD required no additional hospital intervention for access site-related complications during follow-up. SDD appears feasible and safe for eligible patients after catheter ablation for paroxysmal or persistent AF in which the VASCADE MVP is used for venous access-site closure.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Humanos , Alta del Paciente , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Satisfacción del Paciente , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Sistema de Registros , Resultado del Tratamiento
5.
Am Heart J ; 251: 35-42, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35526570

RESUMEN

BACKGROUND: For patients with symptomatic atrial fibrillation (AF), physicians typically offer AF ablation for symptom relief; however, patients often anticipate/expect a life free from anticoagulation. This belief puts patients at increased risk of stroke due to the potential for asymptomatic AF postablation if anticoagulation is ceased contrary to clinical guidelines. Although the WATCHMAN device has been FDA-approved to decrease the risk of thromboembolism from the left atrial appendage (LAA) in patients with an appropriate rationale to avoid oral anticoagulation, it has not been well-studied following AF ablation. Additionally, there are limited data comparing the WATCHMAN device to direct oral anticoagulants. The OPTION study will investigate whether LAA closure with the WATCHMAN FLX device is a reasonable alternative to oral anticoagulation following percutaneous catheter ablation for nonvalvular AF. TRIAL DESIGN: OPTION is a multinational, multicenter, prospective randomized clinical trial. Patients with a CHA2DS2-VASc of ≥2 in men or ≥3 in women and who underwent a AF catheter ablation procedure between 90 and 180 days prior to randomization (sequential) or are planning to have catheter ablation within 10 days of randomization (concomitant) will be randomized in a 1:1 allocation of WATCHMAN FLX vs control. Control patients will start or continue market-approved oral anticoagulation for the duration of the trial. A total of 1600 patients were randomized from 130 global investigational sites. Follow-up for both device and control patients will occur at 3, 12, 24, and 36 months. The primary effectiveness noninferiority endpoint is stroke (ischemic or hemorrhagic), all-cause death, or systemic embolism at 36 months. The primary safety superiority endpoint is nonprocedural bleeding through 36 months (International Society on Thrombosis and Haemostasis [ISTH] major bleeding or clinically relevant nonmajor bleeding). The secondary noninferiority endpoint is ISTH major bleeding through 36 months (including procedural bleeding). CONCLUSIONS: This trial will assess the safety and efficacy of WATCHMAN FLX in a postablation contemporary clinical AF patient population at risk of stroke.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Anticoagulantes/uso terapéutico , Apéndice Atrial/cirugía , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Femenino , Hemorragia/inducido químicamente , Humanos , Masculino , Estudios Prospectivos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
6.
J Cardiovasc Electrophysiol ; 33(5): 831-842, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35174572

RESUMEN

INTRODUCTION: A wearable cardioverter defibrillator (WCD) is indicated in appropriate patients to reduce the risk for sudden cardiac death. Challenges for patients wearing a WCD have been frequent false shock alarms primarily due to electrocardiogram noise and wear discomfort. The objective of this study was to test a contemporary WCD designed for reduced false shock alarms and improved comfort. METHODS: One hundred and thirty patients with left ventricular ejection fraction ≤40% and an active implantable cardioverter defibrillator (ICD) were fitted with the ASSURE WCD (Kestra Medical Technologies) and followed for 30 days. WCD detection was enabled and shock alarm markers recorded, but shocks and shock alarms were disabled. All WCD episodes and ICD ventricular tachycardia/ventricular fibrillation (VT/VF) episodes were adjudicated. The primary endpoint was the false-positive shock alarm rate with a performance goal of 1 every 3.4 days (0.29 per patient-day). RESULTS: Of 163 WCD episodes, 4 were VT/VF and 159 non-VT/VF (121 rhythms with noise, 32 uncertain with noise, 6 atrial flutter without noise). Only three false-positive shock alarm markers were recorded; one false-positive shock alarm every 1333 patient-days (0.00075 per patient-day, 95% confidence interval: 0.00015-0.00361; p < .001). No ICD recorded VT/VF episodes meeting WCD detection criteria (≥170 bpm for ≥20 s) were missed by the WCD during 3501 patient-days of use. Median wear was 31.0 days (interquartile range [IQR] 2.0) and median daily use 23.0 h (IQR 1.7). Adverse events were mostly mild: skin irritation (19.4%) and musculoskeletal discomfort (8.5%). CONCLUSION: The ASSURE WCD demonstrated a low false-positive shock alarm rate, low patient-reported discomfort, and no serious adverse events.


Asunto(s)
Desfibriladores Implantables , Dispositivos Electrónicos Vestibles , Arritmias Cardíacas , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores , Cardioversión Eléctrica/efectos adversos , Electrocardiografía , Humanos , Volumen Sistólico , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/terapia , Función Ventricular Izquierda
7.
JAMA ; 324(16): 1620-1628, 2020 10 27.
Artículo en Inglés | MEDLINE | ID: mdl-33107945

RESUMEN

Importance: Catheter ablation of persistent atrial fibrillation (AF) has limited success. Procedural strategies beyond pulmonary vein isolation have failed to consistently improve results. The vein of Marshall contains innervation and AF triggers that can be ablated by retrograde ethanol infusion. Objective: To determine whether vein of Marshall ethanol infusion could improve ablation results in persistent AF when added to catheter ablation. Design, Setting, and Participants: The Vein of Marshall Ethanol for Untreated Persistent AF (VENUS) trial was an investigator-initiated, National Institutes of Health-funded, randomized, single-blinded trial conducted in 12 centers in the United States. Patients (N = 350) with persistent AF referred for first ablation were enrolled from October 2013 through June 2018. Follow-up concluded in June 2019. Interventions: Patients were randomly assigned to catheter ablation alone (n = 158) or catheter ablation combined with vein of Marshall ethanol infusion (n = 185) in a 1:1.15 ratio to accommodate for 15% technical vein of Marshall ethanol infusion failures. Main Outcomes and Measures: The primary outcome was freedom from AF or atrial tachycardia for longer than 30 seconds after a single procedure, without antiarrhythmic drugs, at both 6 and 12 months. Outcome assessment was blinded to randomization treatment. There were 12 secondary outcomes, including AF burden, freedom from AF after multiple procedures, perimitral block, and others. Results: Of the 343 randomized patients (mean [SD] age, 66.5 [9.7] years; 261 men), 316 (92.1%) completed the trial. Vein of Marshall ethanol was successfully delivered in 155 of 185 patients. At 6 and 12 months, the proportion of patients with freedom from AF/atrial tachycardia after a single procedure was 49.2% (91/185) in the catheter ablation combined with vein of Marshall ethanol infusion group compared with 38% (60/158) in the catheter ablation alone group (difference, 11.2% [95% CI, 0.8%-21.7%]; P = .04). Of the 12 secondary outcomes, 9 were not significantly different, but AF burden (zero burden in 78.3% vs 67.9%; difference, 10.4% [95% CI, 2.9%-17.9%]; P = .01), freedom from AF after multiple procedures (65.2% vs 53.8%; difference, 11.4% [95% CI, 0.6%-22.2%]; P = .04), and success achieving perimitral block (80.6% vs 51.3%; difference, 29.3% [95% CI, 19.3%-39.3%]; P < .001) were significantly improved in vein of Marshall-treated patients. Adverse events were similar between groups. Conclusions and Relevance: Among patients with persistent AF, addition of vein of Marshall ethanol infusion to catheter ablation, compared with catheter ablation alone, increased the likelihood of remaining free of AF or atrial tachycardia at 6 and 12 months. Further research is needed to assess longer-term efficacy. Trial Registration: ClinicalTrials.gov Identifier: NCT01898221.


Asunto(s)
Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Etanol/administración & dosificación , Vena Cava Superior , Anciano , Terapia Combinada/métodos , Femenino , Humanos , Infusiones Intravenosas/efectos adversos , Infusiones Intravenosas/métodos , Estimación de Kaplan-Meier , Masculino , Método Simple Ciego , Taquicardia/terapia , Resultado del Tratamiento , Vena Cava Superior/embriología , Vena Cava Superior/inervación
8.
Pacing Clin Electrophysiol ; 42(9): 1243-1245, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-31390079

RESUMEN

We present a case of an 89-year-old man with a left ventricular assist device and cardiac resynchronization therapy device (CRT-D) who presented with multiple presyncopal events. On the night of admission, telemetry revealed a 13-s pause with appropriately timed pacing spikes but with failure to capture, followed by intermittent ventricular contraction with different QRS morphology. What was the mechanism for his ventricular asystole?


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Paro Cardíaco , Corazón Auxiliar , Anciano de 80 o más Años , Paro Cardíaco/diagnóstico , Ventrículos Cardíacos , Humanos , Masculino
9.
N Engl J Med ; 373(12): 1125-35, 2015 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-26321198

RESUMEN

BACKGROUND: Cardiac pacemakers are limited by device-related complications, notably infection and problems related to pacemaker leads. We studied a miniaturized, fully self-contained leadless pacemaker that is nonsurgically implanted in the right ventricle with the use of a catheter. METHODS: In this multicenter study, we implanted an active-fixation leadless cardiac pacemaker in patients who required permanent single-chamber ventricular pacing. The primary efficacy end point was both an acceptable pacing threshold (≤2.0 V at 0.4 msec) and an acceptable sensing amplitude (R wave ≥5.0 mV, or a value equal to or greater than the value at implantation) through 6 months. The primary safety end point was freedom from device-related serious adverse events through 6 months. In this ongoing study, the prespecified analysis of the primary end points was performed on data from the first 300 patients who completed 6 months of follow-up (primary cohort). The rates of the efficacy end point and safety end point were compared with performance goals (based on historical data) of 85% and 86%, respectively. Additional outcomes were assessed in all 526 patients who were enrolled as of June 2015 (the total cohort). RESULTS: The leadless pacemaker was successfully implanted in 504 of the 526 patients in the total cohort (95.8%). The intention-to-treat primary efficacy end point was met in 270 of the 300 patients in the primary cohort (90.0%; 95% confidence interval [CI], 86.0 to 93.2, P=0.007), and the primary safety end point was met in 280 of the 300 patients (93.3%; 95% CI, 89.9 to 95.9; P<0.001). At 6 months, device-related serious adverse events were observed in 6.7% of the patients; events included device dislodgement with percutaneous retrieval (in 1.7%), cardiac perforation (in 1.3%), and pacing-threshold elevation requiring percutaneous retrieval and device replacement (in 1.3%). CONCLUSIONS: The leadless cardiac pacemaker met prespecified pacing and sensing requirements in the large majority of patients. Device-related serious adverse events occurred in approximately 1 in 15 patients. (Funded by St. Jude Medical; LEADLESS II ClinicalTrials.gov number, NCT02030418.).


Asunto(s)
Arritmias Cardíacas/terapia , Marcapaso Artificial , Adulto , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/mortalidad , Electrocardiografía Ambulatoria , Electrodos Implantados , Diseño de Equipo , Falla de Equipo , Femenino , Estudios de Seguimiento , Humanos , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Estudios Prospectivos
10.
J Cardiovasc Electrophysiol ; 28(4): 416-422, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-28128491

RESUMEN

AIMS: Antitachycardia pacing (ATP) is an effective treatment for ventricular tachycardia (VT) and can reduce the frequency of shocks in patients with an implantable cardioverter defibrillator (ICD). The association between survival and ATP, as compared to a shock, has not been confirmed in a large patient population. This study aims to determine if patients with an ICD receiving ATP have lower mortality, as compared to those receiving shock. METHODS: Sixty-nine thousand three hundred and sixty-eight patients underwent ICD implantation between October 2008 and May 2013 and were enrolled in the remote monitoring network Merlin.net™ (St. Jude Medical, St. Paul, MN, USA). Patients were categorized into three groups based on the type of ICD therapy received during follow-up: no therapy (N = 47,927), ATP (N = 8,049), and shock (N = 13,392) groups. Survival was determined by linking implant records to the Social Security Death Index. RESULTS: The no therapy (hazard ratio [HR] 0.60, 95% confidence interval [CI] 0.56-0.64, P < 0.001) and ATP (HR 0.70, 95% CI 0.64-0.77, P < 0.001) groups were associated with a lower mortality risk than the shock group. These results were unaffected by age, gender, device type, atrial fibrillation (AF) burden, or ventricular rate. ATP was effective in 85% of episodes and ATP effectiveness was dependent on the ventricular rate. CONCLUSIONS: Mortality rates were higher in ICD patients who received only ATP compared to no therapy, but ICD patients who received a shock had higher mortality compared to both groups. Furthermore, the data suggest that age, gender, device type, AF burden, and rate of arrhythmia do not change the trend of higher mortality in patients receiving ICD shock compared to ATP alone.


Asunto(s)
Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Taquicardia Ventricular/terapia , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Femenino , Frecuencia Cardíaca , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Falla de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
12.
J Cardiovasc Electrophysiol ; 26(5): 520-6, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25651872

RESUMEN

BACKGROUND: The ubiquitous presence of internet-connected phones and tablets presents a new opportunity for cost-effective and efficient electrocardiogram (ECG) screening and on-demand diagnosis. Wireless, single-lead real-time ECG monitoring supported by iOS and android devices can be obtained quickly and on-demand. ECGs can be immediately downloaded and reviewed using any internet browser. OBJECTIVE: We compared the standard 12-lead ECG to the smartphone ECG in healthy young adults, elite athletes, and cardiology clinic patients. Accuracy for determining baseline ECG intervals and rate and rhythm was assessed. METHODS: In 381 participants, 30-second lead I ECG waveforms were obtained using an iPhone case or iPad. Standard 12-lead ECGs were acquired immediately after the smartphone tracing was obtained. De-identified ECGs were interpreted by automated algorithms and adjudicated by two board-certified electrophysiologists. RESULTS: Both smartphone and standard ECGs detected atrial rate and rhythm, AV block, and QRS delay with equal accuracy. Sensitivities ranged from 72% (QRS delay) to 94% (atrial fibrillation). Specificities were all above 94% for both modalities. CONCLUSION: Smartphone ECG accurately detects baseline intervals, atrial rate, and rhythm and enables screening in diverse populations. Efficient ECG analysis using automated discrimination and an enhanced smartphone application with notification capabilities are features that can be easily incorporated into the acquisition process.


Asunto(s)
Arritmias Cardíacas/diagnóstico , Electrocardiografía/métodos , Frecuencia Cardíaca , Tamizaje Masivo/instrumentación , Aplicaciones Móviles , Teléfono Inteligente , Telemedicina/instrumentación , Telemetría/instrumentación , Tecnología Inalámbrica/instrumentación , Adolescente , Adulto , Anciano , Algoritmos , Arritmias Cardíacas/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/fisiopatología , Actitud hacia los Computadores , Automatización , Estudios de Casos y Controles , Femenino , Conocimientos, Actitudes y Práctica en Salud , Humanos , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Procesamiento de Señales Asistido por Computador , Encuestas y Cuestionarios , Adulto Joven
13.
Cureus ; 16(4): e57835, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38590983

RESUMEN

Atrial fibrillation (AF) is widely accepted to be the most common sustained arrhythmia, with an increasing incidence over time. This is thought to be due to the aging population across the world. AF occurs when abnormal electrical foci result in disorganization of atrial depolarization, though the exact pathophysiology leading to these abnormal foci is not well understood. A range of interventions exist for AF - pharmacological therapies (anti-arrhythmic or negative chronotropic medications), cardioversion, or ablations to interrupt the abnormal conduction pathways. Ablation may be via a catheter-based approach, via a surgical approach using the "Maze" procedure (Cox-Maze IV), or more recently, via a hybrid approach. This first involves a surgical epicardial ablation, with catheter-based endocardial ablation following a few weeks later to ensure durable transmural lesion sets via the "Convergent" procedure. We describe the use of the Da Vinci Xi™ robotic platform to improve the procedure, allowing continuous and improved visualization of the anatomy without the need for potentially harmful retraction of the atrial appendage or the back of the left atrium, as well as increased precision with our mapping tools and more complete ablation. Here, we highlight the advantages over a non-robotic (subxiphoid) Convergent procedure, while outlining the key operative steps in undertaking the "Robotic Convergent Plus" procedure using the Da Vinci Xi™ robotic surgical system.

14.
Heart Rhythm ; 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38697271

RESUMEN

BACKGROUND: The first dual-chamber leadless pacemaker (DC-LP) system consists of 2 separate atrial and ventricular devices that communicate to maintain synchronous atrioventricular pacing and sensing. The initial safety and efficacy were previously reported. OBJECTIVE: The purpose of this study was to evaluate the chronic electrical performance of the DC-LP system. METHODS: Patients meeting standard dual-chamber pacing indications were enrolled and implanted with the DC-LP system (Aveir DR, Abbott), including right atrial and ventricular helix-fixation LPs (atrial leadless pacemaker [ALP], ventricular leadless pacemaker [VLP]). Pacing capture threshold, sensed amplitude, and pacing impedance were collected using the device programmer at prespecified timepoints from 0-6 months postimplant. RESULTS: De novo devices were successfully implanted in 381 patients with complete 6-month data (62% male; age 69 ± 14 years; weight 82 ± 20 kg; 65% sinus nodal dysfunction, 30% atrioventricular block). ALPs were implanted predominantly in the right atrial appendage anterior base and VLPs primarily at the mid-to-apical right ventricular septum. From implant to 1 month, pacing capture thresholds (0.4-ms pulse width) improved in both ALPs (2.4 ± 1.5 V to 0.8 ± 0.8 V; P <.001) and VLPs (0.8 ± 0.6 V to 0.6 ± 0.4 V; P <.001). Sensed amplitudes improved in both ALPs (1.8 ± 1.3 mV to 3.4 ± 1.9 mV; P <.001) and VLPs (8.8 ± 4.0 mV to 11.7 ± 4.2 mV; P <.001). Impedances were stable in ALPs (334 ± 68 Ω to 329 ± 52 Ω; P = .17) and reduced in VLPs (789 ± 351 Ω to 646 ± 190 Ω; P <.001). Electrical measurements remained relatively stable from 1-6 months postimplant. No differences in electrical metrics were observed among ALP or VLP implant locations. CONCLUSION: This first in-human evaluation of the new dual-chamber leadless pacemaker system demonstrated reliable electrical performance throughout the initial 6-month evaluation period.

15.
PLoS One ; 18(3): e0281340, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36917566

RESUMEN

INTRODUCTION: The wearable cardioverter defibrillator (WCD) is used to protect patients at risk for sudden cardiac arrest. We examined defibrillation efficacy and safety of a biphasic truncated exponential waveform designed for use in a contemporary WCD in three animal studies and a human study. METHODS: Animal (swine) studies: #1: Efficacy comparison of a 170J BTE waveform (SHOCK A) to a 150J BTE waveform (SHOCK B) that approximates another commercially available waveform. Primary endpoint first shock success rate. #2: Efficacy comparison of the two waveforms at attenuated charge voltages in swine at three prespecified impedances. Primary endpoint first shock success rate. #3: Safety comparison of SHOCK A and SHOCK B in swine. Primary endpoint cardiac biomarker level changes baseline to 6 and 24 hours post-shock. Human Study: Efficacy comparison of SHOCK A to prespecified goal and safety evaluation. Primary endpoint cumulative first and second shock success rate. Safety endpoint adverse events. RESULTS: Animal Studies #1: 120 VF episodes in six swine. First shock success rates for SHOCK A and SHOCK B were 100%; SHOCK A non-inferior to SHOCK B (entire 95% CI of rate difference above -10% margin, p < .001). #2: 2,160 VF episodes in thirty-six swine. Attenuated SHOCK A was non-inferior to attenuated SHOCK B at each impedance (entire 95% CI of rate difference above -10% margin, p < .001). #3: Ten swine, five shocked five times each with SHOCK A, five shocked five times each with SHOCK B. No significant difference in troponin I (p = 0.658) or creatine phosphokinase (p = 0.855) changes from baseline between SHOCK A and SHOCK B. Human Study: Thirteen patients, 100% VF conversion rate. Mild skin irritation from adhesive defibrillation pads in three patients. CONCLUSIONS: The BTE waveform effectively and safely terminated induced VF in swine and a small sample in humans. TRIAL REGISTRATION: Human study clinical trial registration: URL: https://clinicaltrials.gov; Unique identifier: NCT04132466.


Asunto(s)
Fibrilación Ventricular , Dispositivos Electrónicos Vestibles , Humanos , Porcinos , Animales , Fibrilación Ventricular/terapia , Resultado del Tratamiento , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/métodos , Desfibriladores
16.
Heart Rhythm ; 20(8): 1146-1155, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37075958

RESUMEN

BACKGROUND: Dual-chamber leadless pacemakers (LPs) require robust communication between distinct right atrial (RA) and right ventricular (RV) LPs to achieve atrioventricular (AV) synchrony. OBJECTIVE: The purpose of this preclinical study was to evaluate a novel, continuous implant-to-implant (i2i™) communication methodology for maintaining AV-synchronous, dual-chamber DDD(R) pacing by the 2 LPs. METHODS: RA and RV LPs were implanted and paired in 7 ovine subjects (4 with induced complete heart block). AV synchrony (% AV intervals <300 ms) and i2i communication success (% successful i2i transmissions between LPs) were evaluated acutely and chronically. During acute testing, 12-lead electrocardiographic and LP diagnostic data were collected from 5-minute recordings, in 4 postures and 2 rhythms (AP-VP and AS-VP, or AP-VS and AS-VS) per subject. Chronic i2i performance was evaluated through 23 weeks postimplant (final i2i evaluation period: week 16-23). RESULTS: Acute AV synchrony and i2i communication success across multiple postures and rhythms were median [interquartile range] 100.0% [100.0%-100.0%] and 99.9% [99.9%-99.9%], respectively. AV synchrony and i2i success rates did not differ across postures (P = .59, P = .11) or rhythms (P = 1, P = .82). During the final i2i evaluation period, the overall i2i success was 98.9% [98.1%-99.0%]. CONCLUSION: Successful AV-synchronous, dual-chamber DDD(R) leadless pacing using a novel, continuous, wireless communication modality was demonstrated across variations in posture and rhythm in a preclinical model.


Asunto(s)
Bloqueo Atrioventricular , Marcapaso Artificial , Humanos , Animales , Ovinos , Estimulación Cardíaca Artificial/métodos , Lipopolisacáridos , Bloqueo Atrioventricular/terapia , Frecuencia Cardíaca
17.
Circ Arrhythm Electrophysiol ; 16(10): e012232, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37767710

RESUMEN

BACKGROUND: The clinical utilization of leadless pacemakers (LPs) as an alternative to traditional transvenous pacemakers is likely to increase with the advent of dual-chamber LP systems. Since device retrieval to allow LP upgrade or replacement will become an important capability, the first such dual-chamber, helix-fixation LP system (Aveir DR; Abbott, Abbott Park, IL) was specifically designed to allow catheter-based retrieval. In this study, the preclinical performance and safety of retrieving chronically implanted dual-chamber LPs was evaluated. METHODS: Atrial and ventricular LPs were implanted in the right atrial appendage and right ventricular apex of 9 healthy ovine subjects. After ≈2 years, the LPs were retrieved using a dedicated transvenous retrieval catheter (Aveir Retrieval Catheter; Abbott) by snaring, docking, and unscrewing from the myocardium. Comprehensive necropsy/histopathology studies were conducted to evaluate device- and procedure-related outcomes. RESULTS: At a median of 1.9 years postimplant (range, 1.8-2.6), all 18 of 18 (100%) LPs were retrieved from 9 ovine subjects without complications. The median retrieval procedure duration for both LPs, from first-catheter-in to last-catheter-out, was 13.3 minutes (range, 2.5-36.4). Postretrieval, all right atrial, and right ventricular implant sites demonstrated minimal tissue disruption, with intact fibrous tissue limited to the distal device body. No significant device-related trauma, perforation, pericardial effusion, right heart or tricuspid valve injury, or chronic pulmonary thromboembolism were observed at necropsy. CONCLUSIONS: This preclinical study demonstrated the safe and effective retrieval of chronically implanted, helix-fixation, dual-chamber LP systems, paving the way for clinical studies of LP retrieval.


Asunto(s)
Fibrilación Atrial , Marcapaso Artificial , Humanos , Ovinos , Animales , Lipopolisacáridos , Oveja Doméstica , Ventrículos Cardíacos , Diseño de Equipo
18.
Heart Rhythm O2 ; 4(7): 448-456, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37520021

RESUMEN

Background: The subcutaneous implantable cardioverter-defibrillator (S-ICD) has demonstrated safety and efficacy for the treatment of malignant ventricular arrhythmias. However, a limitation of the S-ICD lies in the inability to either pace-terminate ventricular tachycardia or provide prolonged bradycardia pacing support. Objective: The rationale and design of a prospective, single-arm, multinational trial of an intercommunicative leadless pacing system integrated with the S-ICD will be presented. Methods: A technical description of the modular cardiac rhythm management (mCRM) system (EMPOWER leadless pacemaker and EMBLEM S-ICD) and the implantation procedure is provided. MODULAR ATP (Effectiveness of the EMPOWER™ Modular Pacing System and EMBLEM™ Subcutaneous ICD to Communicate Antitachycardia Pacing) is a multicenter, international trial enrolling up to 300 patients at risk of sudden cardiac death at up to 60 centers trial design. The safety endpoint of freedom from major complications related to the mCRM system or implantation procedure at 6 months and 2 years are significantly higher than 86% and 81%, respectively, and all-cause survival is significantly >85% at 2 years. Results: Efficacy endpoints are that at 6 months mCRM communication success is significantly higher than 88% and the percentage of subjects with low and stable thresholds is significantly higher than 80%. Substudies to evaluate rate-responsive features and performance of the pacing module are also described. Conclusion: The MODULAR ATP global clinical trial will prospectively test the safety and efficacy of the first intercommunicating leadless pacing system with the S-ICD. This trial will allow for robust validation of device-device communication, pacing performance, rate responsiveness, and system safety.

19.
J Cardiovasc Electrophysiol ; 23(8): 820-6, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22509886

RESUMEN

INTRODUCTION: The Hansen Robotic system has been utilized in ablation procedures for atrial fibrillation (AF). However, because of the lack of tactile feedback and the rigidity of the robotic sheath, this approach could result in higher risk of complications. This worldwide survey reports a multicenter experience on the methodology, efficacy, and safety of the Hansen system in AF ablations. METHODS AND RESULTS: A questionnaire addressing questions on patient's demographics, procedural parameters, ablation success rate and safety information was sent to all centers where more than 50 robotic AF ablation cases have been performed. From June 2007 to December 2009, 1,728 procedures were performed at 12 centers utilizing the Hansen robotic navigation technology. The overall complication rate was 4.7% and the success rate was 67.1% after 18 ± 4 months of follow-up. In 5 low volume centers there appeared to be a learning curve of about 50 cases (complication rate 11.2% for the first 50 cases vs 3.7% for the 51-100 cases; P = 0.044) and a trend showing a decrease of complication rate with increasing case volume. However, in the remaining 7 centers no learning curve was present and the complication rate was stable over time (3.7% for the first 50 cases vs 3.6% for the 51st case thereafter; P = 0.942). CONCLUSION: The Hansen robotic system can be used for AF ablation safely. In low volume centers, there appeared to be a learning curve of the first 50 cases after which the complication rate decreased. With a higher case volume, the success rate increased.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/estadística & datos numéricos , Seguridad del Paciente/estadística & datos numéricos , Pautas de la Práctica en Medicina/estadística & datos numéricos , Robótica/estadística & datos numéricos , Cirugía Asistida por Computador/estadística & datos numéricos , Adulto , Anciano , Anciano de 80 o más Años , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Competencia Clínica/estadística & datos numéricos , Diseño de Equipo , Femenino , Encuestas de Atención de la Salud , Hospitales de Alto Volumen/estadística & datos numéricos , Humanos , Curva de Aprendizaje , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Robótica/instrumentación , Cirugía Asistida por Computador/efectos adversos , Cirugía Asistida por Computador/instrumentación , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento
20.
Pacing Clin Electrophysiol ; 35(3): 348-56, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22150299

RESUMEN

INTRODUCTION: Automatic pacing threshold (AT) testing may simplify device follow-up and improve device longevity. This study's objective was to evaluate the performance of a left ventricular (LV) evoked response sensing-based AT algorithm, for cardiac resynchronization therapy (CRT) devices. METHODS: Patients scheduled for CRT-D/P implant were enrolled. A manual step-down threshold test and a Left Ventricular Automatic Threshold (LVAT) test in each of four pacing vectors-LVTip→Can, LVTip→right ventricle (RV), = LVRing→Can, and LVRing→RV-were conducted. Patients were randomized to either 0.4-ms or 1.0-ms pacing pulse width and in the manual and LVAT test order. A blinded core lab electrophysiologist (EP) determined the threshold using the surface electrocardiogram (gold standard). RESULTS: Data from 70 patients were analyzed. Bipolar LV leads from three major manufacturers were used. A total of 273 AT tests were performed; 12 AT tests did not result in a threshold due to improper testing conditions. Of 261 eligible tests, 234 AT tests (89.6%) returned a threshold measurement. Of the 234 tests, in 233 tests (99.5%) the algorithm-determined threshold matched the EP-determined threshold for that test. A total of 16,689 capture and 526 noncapture beats were collected and the accuracy for detecting capture and noncapture were 98.5% and 99.7% with a two-sided 95% confidence level of (98.4%, 98.7%) and (99.4%, 100%), respectively. No AT threshold measurement was lower than the EP-determined threshold. CONCLUSION: In this study, the results suggest that the LVAT algorithm is accurate at determining pacing thresholds in multiple pacing configurations and a wide range of LV leads in CRT-D/P patients.


Asunto(s)
Algoritmos , Estimulación Cardíaca Artificial/métodos , Dispositivos de Terapia de Resincronización Cardíaca , Ventrículos Cardíacos/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Electrocardiografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad