Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Medicina (Kaunas) ; 59(7)2023 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-37512026

RESUMEN

Background and Objectives: Minimally invasive surgeries for acetabulum fracture fixation are gaining popularity due to their known advantages versus open reduction and internal fixation. Antegrade or retrograde screw fixation along the long axis of the posterior column of the acetabulum is increasingly applied in surgical practice. While there is sufficient justification in the literature for the application of the anterior approach, there is a deficit of reports related to the posterior approach. The aim of this study was to evaluate the biomechanical competence of posterior column acetabulum fracture fixation through antegrade screw placement using either a standard cannulated screw or a cannulated compression headless screw (CCHS) via posterior approach. Materials and Methods: Eight composite pelvises were used, and a posterior column acetabulum fracture according to the Letournel Classification was simulated on both their left and right sides via an osteotomy. The sixteen hemi-pelvic specimens were assigned to two groups (n = 8) for either posterior column standard screw (group PCSS) or posterior column CCHS (group PCCH) fixation. Biomechanical testing was performed by applying steadily increased cyclic load until failure. Interfragmentary movements were investigated by means of motion tracking. Results: Initial stiffness demonstrated significantly higher values in PCCH (163.1 ± 14.9 N/mm) versus PCSS (133.1 ± 27.5 N/mm), p = 0.024. Similarly, cycles and load at failure were significantly higher in PCCH (7176.7 ± 2057.0 and 917.7 ± 205.7 N) versus PCSS (3661.8 ± 1664.5 and 566.2 ± 166.5 N), p = 0.002. Conclusion: From a biomechanical perspective, CCHS fixation demonstrates superior stability and could be a valuable alternative option to the standard cannulated screw fixation of posterior column acetabulum fractures, thus increasing the confidence in postoperative full weight bearing for both the patient and treating surgeon. Whether uneventful immediate postoperative full weight bearing can be achieved with CCHS fixation should primarily be investigated in further human cadaveric studies with a larger sample size.


Asunto(s)
Fracturas Óseas , Fracturas de Cadera , Fracturas de la Columna Vertebral , Humanos , Fracturas Óseas/cirugía , Acetábulo/cirugía , Fijación Interna de Fracturas , Tornillos Óseos , Fenómenos Biomecánicos
2.
Medicina (Kaunas) ; 59(11)2023 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-38004092

RESUMEN

Background and Objectives: The surgical treatment of proximal humeral shaft fractures usually considers application of either long straight plates or intramedullary nails. By being able to spare the rotator cuff and avoid the radial nerve distally, the implementation of helical plates might overcome the downsides of common fixation methods. The aims of the current study were (1) to explore the biomechanical competence of different plate designs and (2) to compare their performance versus the alternative treatment option of using intramedullary nails. Materials and Methods: Twenty-four artificial humeri were assigned to the following four groups for simulation of an unstable proximal humeral shaft fracture and instrumentation: Group 1 (Straight-PHILOS), Group 2 (MULTILOC-Nail), Group 3 (45°-Helical-PHILOS), and Group 4 (90°-Helical-PHILOS). All specimens underwent non-destructive, quasi-static biomechanical testing under loading in axial compression, torsion in internal/external rotation, and pure bending in four directions, accompanied by motion tracking. Results: Axial stiffness/displacement in Group 2 was significantly higher/smaller than in all other groups (p ≤ 0.010). Torsional displacement in Group 2 was significantly bigger than in all other groups (p ≤ 0.017). Significantly smaller coronal plane displacement was identified in Group 2 versus all other groups (p < 0.001) and in Group 4 versus Group 1 (p = 0.022). Significantly bigger sagittal plane displacement was detected in Group 4 versus all other groups (p ≤ 0.024) and in Group 1 versus Group 2 (p < 0.001). Conclusions: Intramedullary nails demonstrated higher axial stiffness and smaller axial interfragmentary movements compared with all investigated plate designs. However, they were associated with bigger torsional movements at the fracture site. Although 90°-helical plates revealed bigger interfragmentary movements in the sagittal plane, they demonstrated improved resistance against displacements in the coronal plane when compared with straight lateral plates. In addition, 45°-helical plates manifested similar biomechanical competence to straight plates and may be considered a valid alternative to the latter from a biomechanical standpoint.


Asunto(s)
Fijación Intramedular de Fracturas , Humanos , Fijación Intramedular de Fracturas/métodos , Clavos Ortopédicos , Fenómenos Biomecánicos , Fijación Interna de Fracturas , Húmero , Placas Óseas
3.
Sensors (Basel) ; 21(1)2020 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-33375087

RESUMEN

This manuscript introduces a programable active bone fixator system that enables systematic investigation of bone healing processes in a sheep animal model. In contrast to previous systems, this solution combines the ability to precisely control the mechanical conditions acting within a fracture with continuous monitoring of the healing progression and autonomous operation of the system throughout the experiment. The active fixator system was implemented on a double osteotomy model that shields the experimental fracture from the influence of the animal's functional loading. A force sensor was integrated into the fixator to continuously measure stiffness of the repair tissue as an indicator for healing progression. A dedicated control unit was developed that allows programing of different loading protocols which are later executed autonomously by the active fixator. To verify the feasibility of the system, it was implanted in two sheep with different loading protocols, mimicking immediate and delayed weight-bearing, respectively. The implanted devices operated according to the programmed protocols and delivered seamless data over the whole course of the experiment. The in vivo trial confirmed the feasibility of the system. Hence, it can be applied in further preclinical studies to better understand the influence of mechanical conditions on fracture healing.


Asunto(s)
Fijadores Externos , Fracturas Óseas , Animales , Técnicas Biosensibles , Curación de Fractura , Osteotomía , Ovinos , Estrés Mecánico
4.
J Orthop Res ; 42(4): 886-893, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37975265

RESUMEN

Dual plating of comminuted distal femoral fractures allows for early patient mobilization. An additional helically shaped medial plate avoids the medial vital structures of the thigh. The aim of this study is to investigate the biomechanical competence of an augmented lateral locking compression plate distal femur (LCP-DF) using an additional straight versus a helically shaped medial LCP of the same length. Ten pairs of human cadaveric femora were instrumented with a lateral anatomical 15-hole LCP-DF. Following, they were pairwise instrumented with either an additional medial straight 14-hole LCP (group 1) or a 90°-helical shape LCP (group 2). All specimens were biomechanically tested under quasi-static and progressively increasing combined cyclic axial and torsional loading until failure. Initial interfragmentary axial displacement and flexion under static compression were significantly smaller in group 1 (0.11 ± 0.12 mm and 0.21 ± 0.10°) versus group 2 (0.31 ± 0.14 mm and 0.68 ± 0.16°), p ≤ 0.007. Initial varus deformation under static compression remained not significantly different between group 1 (0.57 ± 0.23°) and group 2 (0.75 ± 0.34°), p = 0.085. Flexion movements during dynamic loading were significantly bigger in group 2 (2.51 ± 0.54°) versus group 1 (1.63 ± 1.28°), p = 0.015; however, no significant differences were observed in terms of varus, internal rotation, and axial and shear displacements between the groups, p ≥ 0.204. Cycles to failure and load at failure were higher in group 2 (25,172 ± 6376 and 3017 ± 638 N) compared to group 1 (22,277 ± 4576 and 2728 ± 458 N) with no significant differences between them, p = 0.195. From a biomechanical perspective, helical double plating may be considered a useful alternative to straight double plating, demonstrating ameliorated damping capacities during flexion deformation and safer application as the medial neurovascular structures of the thigh are avoided.


Asunto(s)
Fracturas del Fémur , Fijación Interna de Fracturas , Humanos , Fenómenos Biomecánicos , Fémur/cirugía , Placas Óseas , Extremidad Inferior
5.
PLoS One ; 19(6): e0300256, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38829845

RESUMEN

PURPOSE: Due to the increase in life expectancy and high-energy traumas, anterior column acetabular fractures (ACFs) are also increasing. While open reduction and internal fixation (ORIF) is still the standard surgical procedure, minimally invasive, percutaneous fixation of osteoporotic acetabulum fractures (AF) are growing in popularity. The aim of this biomechanical study was to evaluate the biomechanical competence following antegrade fixation with a standard screw versus a cannulated compression headless screw. METHODS: Eight anatomical osteoporotic composite pelvises were given an anterior column fracture. Two groups of eight specimens each (n = 8) for fixation with either a 6.5 mm cannulated compression headless screw in group Anterior Acetabulum Canulated Compression Headless Screw (AACCH), or with a 6.5 mm partially threaded cannulated screw in group Anterior Acetabulum Standard Screw (AASS) where compared. Each specimen was biomechanically loaded cyclically at a rate of 2 Hz with monotonically increasing compressive load until failure. Motions were assessed by means of optical motion tracking. RESULTS: Initial construct stiffness trended higher in group AACCH at 152.4 ± 23.1 N/mm compared to group AASS at 118.5 ± 34.3 N/mm, p = 0.051. Numbers of cycles and corresponding peak load at failure, were significantly higher in group AACCH at 6734 ± 1669 cycles and 873.4 ± 166.9 N versus group AASS at 4440 ± 2063 cycles and 644.0 ± 206.3 N, p = 0.041. Failure modes were breakout of the screws around the proximal entry point. CONCLUSION: From a biomechanical perspective, group AACCH was associated with superior biomechanical competence compared to standard partially threaded cannulated screws and could therefore be considered as valid alternative for fixation of anterior acetabulum fractures.


Asunto(s)
Acetábulo , Tornillos Óseos , Fijación Interna de Fracturas , Acetábulo/cirugía , Acetábulo/lesiones , Humanos , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/instrumentación , Fenómenos Biomecánicos , Fracturas Óseas/cirugía , Osteoporosis/cirugía , Osteoporosis/fisiopatología , Osteoporosis/complicaciones
6.
Data Brief ; 50: 109489, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37645448

RESUMEN

This data article presents the experimental data of the wear behavior of four types of open-cell AlSi10Mg materials and open-cell AlSi10Mg-Al2O3 composites with different pore sizes under dry sliding conditions tested by pin-on-disk method. The data include the coefficient of friction (COF) as a function of time for each material, as well as the predictions of COF using a machine learning model - Extreme Gradient Boosting. The data were generated to investigate the effect of pore size and reinforcement on the friction and wear properties of open-cell AlSi10Mg-Al2O3 composites, which are promising materials for lightweight and wear-resistant applications. The data can also be used to validate theoretical models or numerical simulations of wear mechanisms in porous materials, as well as to optimize the material design and processing parameters to enhance the wear resistance of open-cell AlSi10Mg materials. The data are available in DWF and XLSX format and can be opened by any text editor or spreadsheet software. The data article is related to an original research article entitled "Production and Tribological Characterization of Advanced Open-Cell AlSi10Mg-Al2O3 Composites", where the details of the experimental methods, the microstructural characterization, and the analysis of the wear mechanisms are provided [1].

7.
Materials (Basel) ; 16(18)2023 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-37763486

RESUMEN

Open-cell AMMCs are high-strength and lightweight materials with applications in different types of industries. However, one of the main goals in using these materials is to enhance their tribological behavior, which improves their durability and performance under frictional conditions. This study presents an approach for fabricating and predicting the wear behavior of open-cell AlSn6Cu-SiC composites, which are a type of porous AMMCs with improved tribological properties. The composites were fabricated using liquid-state processing, and their tribological properties are investigated by the pin-on-disk method under different loads (50 N and 100 N) and with dry-sliding friction. The microstructure and phase composition of the composites were investigated by scanning electron microscopy, energy-dispersive X-ray spectroscopy, and X-ray diffraction. The mass wear and coefficient of friction (COF) of the materials were measured as quantitative indicators of their tribological behavior. The results showed that the open-cell AlSn6Cu-SiC composite had an enhanced tribological behavior compared to the open-cell AlSn6Cu material in terms of mass wear (38% decrease at 50 N and 31% decrease at 100 N) while maintaining the COF at the same level. The COF of the composites was predicted by six different machine learning methods based on the experimental data. The performance of these models was evaluated by various metrics (R2, MSE, RMSE, and MAE) on the validation and test sets. Based on the results, the open-cell AlSn6Cu-SiC composite outperformed the open-cell AlSn6Cu material in terms of mass loss under different loads with similar COF values. The ML models that were used can predict the COF accurately and reliably based on features, but they are affected by data quality and quantity, overfitting or underfitting, and load change.

8.
Data Brief ; 49: 109461, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37577731

RESUMEN

This data article describes the stress-strain curves, energy absorption and energy absorption efficiency of open-cell AlSi10Mg materials and open-cell AlSi10Mg-SiC composites with different pore sizes and strain rates. The data were obtained by quasi-static compression loading up to 60% strain at strain rates of 0.01 and 0.001 s-1 according to ISO 13,314:2011 standard. The data can be used to compare the effects of pore size and strain rate on the compressive properties of the materials. The data are related to the research article entitled "Fabrication, Experimental Investigation and Prediction of Wear Behavior of Open-Cell AlSi10Mg-SiC Composite Materials" (Kolev, M., Drenchev, L., & Petkov, V. (2023). Fabrication, Experimental Investigation and Prediction of Wear Behavior of Open-Cell AlSi10Mg-SiC Composite Materials. Metals, 13(4), 814. MDPI AG. Retrieved from http://dx.doi.org/10.3390/met13040814).

9.
Front Bioeng Biotechnol ; 11: 1170977, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37064234

RESUMEN

Pancarpal canine arthrodesis (PCA) sets immobilization of all three carpal joints via dorsal plating to result in bony fusion. Whereas the first version of the plate uses a round hole (RH) for the radiocarpal (RC) screw region, its modification into an oval hole (OH) in a later version improves versatility in surgical application. The aim of this study was to mechanically investigate the fatigue life of the PCA plate types implementing these two features-PCA-RH and PCA-OH. Ten PCA-RH and 20 PCA-OH stainless steel (316LVM) plates were assigned to three study groups (n = 10). All plates were pre-bent at 20° and fixed to a canine forelimb model with simulated radius, RC bone and third metacarpal bone. The OH plates were fixed with an RC screw inserted either most proximal (OH-P) or most distal (OH-D). All specimens were cyclically tested at 8 Hz under 320 N loading until failure. Fatigue life outcome measures were cycles to failure and failure mode. Cycles to failure were higher for RH plate fixation (695,264 ± 344,023) versus both OH-P (447,900 ± 176,208) and OH-D (391,822 ± 165,116) plate configurations, being significantly different between RH and OH-D, p = 0.03. No significant difference was detected between OH-P and OH-D configurations, p = 0.09. Despite potential surgical advantages, the shorter fatigue life of the PCA-OH plate design may mitigate its benefits compared to the plate design with a round radiocarpal screw hole. Moreover, the failure risk of plates with an oval hole is increased regardless from the screw position in this hole. Based on these findings, the PCA plate with the current oval radiocarpal screw hole configuration cannot be recommended for clinical use.

10.
Clin Biomech (Bristol, Avon) ; 110: 106119, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37832469

RESUMEN

BACKGROUND: Distal femoral fractures are commonly treated with lateral straight plates. However, the lateral approach may not always be desirable, and 180°-helical plates may be an alternative. AIM: To investigate the biomechanical competence of 180°-helical plating versus standard straight lateral plating of unstable fractures at the distal femur. METHODS: Twelve left artificial femora were instrumented with a 15-hole Locking Compression Plate-Distal Femur, using either 180°-helical plates (group 1) or conventional straight lateral plates (group 2). An unstable distal femoral fracture AO/OTA 33-A3.3 was simulated. All specimens were biomechanically tested under quasi-static and progressively increasing combined cyclic axial and torsional loading in internal rotation until failure. FINDINGS: Initial axial stiffness (N/mm) was significantly higher in group 1 (185.6 ± 50.1) compared to group 2 (56.0 ± 14.4), p < 0.001. Group 1 demonstrated significantly higher initial interfragmentary flexion (°) and significantly lower initial varus/valgus deformation (°) under 500 N static axial compression versus group 2 (2.76 ± 1.02 versus 0.87 ± 0.77 and 4.08 ± 1.49 versus 6.60 ± 0.47), p ≤ 0.005. Shear displacement (mm) under 6 Nm static torsion was significantly higher in group 1 versus group 2 in both internal (1.23 ± 0.28 versus 0.40 ± 0.42) and external (1.21 ± 0.40 versus 0.57 ± 0.33) rotation, p ≤ 0.013. Cycles to failure and failure load (N) (clinical/catastrophic) were significantly higher in group 1 (12,484 ± 2116/13,752 ± 1518 and 1748.4 ± 211.6/1875.2 ± 151.8) compared to group 2 (7853 ± 1262/9727 ± 836 and 1285.3 ± 126.2/1472.7 ± 83.6), p ≤ 0.001. INTERPRETATION: Although 180°-helical plating using a pre-contoured standard straight lateral plate was associated with higher shear and flexion movements, it demonstrated improved initial axial stability and resistance against varus/valgus deformation compared to straight lateral plating. Moreover, the helical plates were associated with significantly higher endurance to failure. From a biomechanical perspective, 180°-helical plating may be considered as a valuable alternative to standard straight lateral plating of unstable distal femoral fractures.


Asunto(s)
Fracturas Femorales Distales , Fracturas del Fémur , Humanos , Fracturas del Fémur/cirugía , Fenómenos Biomecánicos , Fijación Interna de Fracturas , Placas Óseas
11.
Biomedicines ; 9(8)2021 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-34440192

RESUMEN

It is well known that mechanical stimulation promotes indirect fracture healing by triggering callus formation. We investigated the short-term response of healing tissue to mechanical stimulation to compare the changes in tissue stiffness during stimulation and resting phases in a preclinical case-series. Four sheep underwent a tibial osteotomy and were instrumented with a custom-made active fixator which applied a mechanical stimulation protocol of 1000 cycles/day, equally distributed over 12 h, followed by 12 h of rest. During each cycle, a surrogate metric for tissue stiffness was measured, enabling a continuous real-time monitoring of the healing progression. A daily stiffness increase during stimulation and an increase during resting were evaluated for each animal. One animal had to be excluded from the evaluation due to technical reasons. For all included animals, the stiffness began to increase within the second week post-op. A characteristic pattern was observed during daily measurements: the stiffness dropped considerably within the first stimulation cycles followed by a steady rise throughout the rest of the stimulation phase. However, for all included animals, the average daily stiffness increase within the first three weeks post operation was larger during resting than during stimulation (Sheep I: 16.9% vs. -5.7%; Sheep II: 14.7% vs. -1.8%; Sheep III: 8.9% vs. 1.6%). A continuous measurement of tissue stiffness together with a controlled fracture stimulation enabled the investigation of the short-term effects of specific stimulatory parameters, such as resting periods. Resting was identified as a potentially determining factor for bone healing progression. Optimizing the ratio between stimulation and resting may contribute to more robust fracture healing in the future.

12.
Biomed Res Int ; 2021: 2526879, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34513988

RESUMEN

Hybrid locking pancarpal arthrodesis plates were designed with either a round (RH) or an oval (OH) radiocarpal hole, the latter allowing varied screw positioning. Due to concerns about potential decreased structural properties of the OH design, our aim was to compare the mechanical behavior of the contrasting plates using combined finite element analysis (FEA) and mechanical testing. Pancarpal arthrodesis plates with RH or OH design were assigned to three fixation techniques (n = 6), prebent at 20°, and fixed to canine forelimb models with simulated radius and radiocarpal and 3rd metacarpal bones. OH plates were instrumented with a radiocarpal screw inserted either most proximal (OH-P) or most distal (OH-D). Specimens were axially loaded to 300 N over 10 ramped cycles at 0.5 Hz. Plate strains were measured with strain gauges placed at areas of highest deformations as predicted by FEA under identical loading conditions. FEA predicted the highest strains (µm/m) adjacent to the radiocarpal hole (2,500 [RH], 2,900 [OH-P/OH-D]) and plate bending point (2,250 [RH], 1,900 [OH-P/OH-D]). Experimentally, peak radiocarpal hole strains were not influenced by the OH screw position (3,329 ± 443 [OH-P], 3,222 ± 467 [OH-D]; P = 0.550) but were significantly higher compared to the RH design (2,123 ± 154; P < 0.001). Peak strains at the bending point were significantly lower for OH-P (1,792 ± 174) and OH-D (1,806 ± 194) versus RH configurations (2,158 ± 114) (P ≤ 0.006). OH plates demonstrated highest peak strains next to the radiocarpal hole and were associated with more heterogenous plate strain distribution. Structural weakening associated with radiocarpal OH plate design could result in decreased fixation strength and increased risk of plate fatigue failure.


Asunto(s)
Artrodesis/métodos , Placas Óseas/efectos adversos , Fijación Interna de Fracturas/métodos , Animales , Artrodesis/veterinaria , Fenómenos Biomecánicos , Placas Óseas/veterinaria , Tornillos Óseos/veterinaria , Perros , Análisis de Elementos Finitos , Ensayo de Materiales/métodos , Estrés Mecánico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA