Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38032788

RESUMEN

Measuring center-of-pressure (COP) trajectories in out-of-the-lab environments may provide valuable information about changes in gait and balance function related to natural disease progression or treatment in neurological disorders. Traditional equipment to acquire COP trajectories includes stationary force plates, instrumented treadmills, electronic walkways, and insoles featuring high-density force sensing arrays, all of which are expensive and not widely accessible. This study introduces novel deep recurrent neural networks that can accurately estimate dynamic COP trajectories by fusing data from affordable and heterogeneous insole-embedded sensors (namely, an eight-cell array of force sensitive resistors (FSRs) and an inertial measurement unit (IMU)). The method was validated against gold-standard equipment during out-of-the-lab ambulatory tasks that simulated real-world walking. Root-mean-square errors (RMSE) in the mediolateral (ML) and anteroposterior (AP) directions obtained from healthy individuals (ML: 0.51 cm, AP: 1.44 cm) and individuals with neuromuscular conditions (ML: 0.59 cm, AP: 1.53 cm) indicated technical validity. In individuals with neuromuscular conditions, COP-derived metrics showed significant correlations with validated clinical measures of ambulatory function and lower-extremity muscle strength, providing proof-of-concept evidence of the convergent validity of the proposed method for clinical applications.


Asunto(s)
Aprendizaje Profundo , Humanos , Marcha/fisiología , Caminata , Redes Neurales de la Computación , Pie/fisiología , Fenómenos Biomecánicos
2.
Wearable Technol ; 4: e14, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38487773

RESUMEN

Background: Imbalance and gait disturbances are common in patients with vestibular schwannoma (VS) and can result in significant morbidity. Current methods for quantitative gait analysis are cumbersome and difficult to implement. Here, we use custom-engineered instrumented insoles to evaluate the gait of patients diagnosed with VS. Methods: Twenty patients with VS were recruited from otology, neurosurgery, and radiation oncology clinics at a tertiary referral center. Functional gait assessment (FGA), 2-minute walk test (2MWT), and uneven surface walk test (USWT) were performed. Custom-engineered instrumented insoles, equipped with an 8-cell force sensitive resistor (FSR) and a 9-degree-of-freedom inertial measurement unit (IMU), were used to collect stride-by-stride spatiotemporal gait parameters, from which mean values and coefficients of variation (CV) were determined for each patient. Results: FGA scores were significantly correlated with gait metrics obtained from the 2MWT and USWT, including stride length, stride velocity, normalized stride length, normalized stride velocity, stride length CV, and stride velocity CV. Tumor diameter was negatively associated with stride time and swing time on the 2MWT; no such association existed between tumor diameter and FGA or DHI. Conclusions: Instrumented insoles may unveil associations between VS tumor size and gait dysfunction that cannot be captured by standardized clinical assessments and self-reported questionnaires.

3.
Artículo en Inglés | MEDLINE | ID: mdl-35025747

RESUMEN

Instrumented footwear represents a promising technology for spatiotemporal gait analysis in out-of-the-lab conditions. However, moderate accuracy impacts this technology's ability to capture subtle, but clinically meaningful, changes in gait patterns that may indicate adverse outcomes or underlying neurological conditions. This limitation hampers the use of instrumented footwear to aid functional assessments and clinical decision making. This paper introduces new transductive-learning inference models that substantially reduce measurement errors relative to conventional data processing techniques, without requiring subject-specific labelled data. The proposed models use subject-optimized input features and hyperparameters to adjust the spatiotemporal gait metrics (i.e., stride time, length, and velocity, swing time, and double support time) obtained with conventional techniques, resulting in computationally simpler models compared to end-to-end machine learning approaches. Model validity and reliability were evaluated against a gold-standard electronic walkway during a clinical gait performance test (6-minute walk test) administered to N = 95 senior residents of assisted living facilities with diverse levels of gait and balance impairments. Average reductions in absolute errors relative to conventional techniques were -42.0% and -33.5% for spatial and gait-phase parameters, respectively, indicating the potential of transductive learning models for improving the accuracy of instrumented footwear for ambulatory gait analysis.


Asunto(s)
Instituciones de Vida Asistida , Análisis de la Marcha , Anciano , Marcha , Humanos , Reproducibilidad de los Resultados , Análisis Espacio-Temporal , Caminata
4.
IEEE Int Conf Rehabil Robot ; 2019: 145-150, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31374621

RESUMEN

The trend toward soft wearable robotic systems creates a compelling need for new and reliable sensor systems that do not require a rigid mounting frame. Despite the growing use of inertial measurement units (IMUs) in motion tracking applications, sensor drift and IMU-to-segment misalignment still represent major problems in applications requiring high accuracy. This paper proposes a novel 2-step calibration method which takes advantage of the periodic nature of human locomotion to improve the accuracy of wearable inertial sensors in measuring lower-limb joint angles. Specifically, the method was applied to the determination of the hip joint angles during walking tasks. The accuracy and precision of the calibration method were accessed in a group of N =8 subjects who walked with a custom-designed inertial motion capture system at 85% and 115% of their comfortable pace, using an optical motion capture system as reference. In light of its low computational complexity and good accuracy, the proposed approach shows promise for embedded applications, including closed-loop control of soft wearable robotic systems.


Asunto(s)
Locomoción , Dispositivos Electrónicos Vestibles , Calibración , Marcha/fisiología , Articulación de la Cadera/fisiología , Humanos , Masculino , Análisis de Regresión , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA