Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-39082726

RESUMEN

AIMS: Recommendations on cardiac resynchronization therapy (CRT) in patients with atrial fibrillation or flutter (AF) are based on less robust evidence than those in sinus rhythm (SR). We aimed to assess the efficacy of CRT upgrade in the BUDAPEST-CRT Upgrade trial population by their baseline rhythm. METHODS AND RESULTS: Heart failure patients with reduced ejection fraction (HFrEF) and previously implanted pacemaker (PM) or implantable cardioverter defibrillator (ICD) and ≥20% right ventricular (RV) pacing burden were randomized to CRT with defibrillator (CRT-D) upgrade (n = 215) or ICD (n = 145). Primary [HF hospitalization (HFH), all-cause mortality, or <15% reduction of left ventricular end-systolic volume] and secondary outcomes were investigated. At enrolment, 131 (36%) patients had AF, who had an increased risk for HFH as compared with those with SR [adjusted hazard ratio (aHR) 2.99; 95% confidence interval (CI) 1.26-7.13; P = 0.013]. The effect of CRT-D upgrade was similar in patients with AF as in those with SR [AF adjusted odds ratio (aOR) 0.06; 95% CI 0.02-0.17; P < 0.001; SR aOR 0.13; 95% CI 0.07-0.27; P < 0.001; interaction P = 0.29] during the mean follow-up time of 12.4 months. Also, it decreased the risk of HFH or all-cause mortality (aHR 0.33; 95% CI 0.16-0.70; P = 0.003; interaction P = 0.17) and improved the echocardiographic response (left ventricular end-diastolic volume difference -49.21 mL; 95% CI -69.10 to -29.32; P < 0.001; interaction P = 0.21). CONCLUSION: In HFrEF patients with AF and PM/ICD with high RV pacing burden, CRT-D upgrade decreased the risk of HFH and improved reverse remodelling when compared with ICD, similar to that seen in patients in SR.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Volumen Sistólico , Humanos , Fibrilación Atrial/terapia , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/mortalidad , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Terapia de Resincronización Cardíaca/métodos , Anciano , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/mortalidad , Resultado del Tratamiento , Persona de Mediana Edad , Función Ventricular Derecha , Función Ventricular Izquierda , Dispositivos de Terapia de Resincronización Cardíaca , Factores de Riesgo , Hospitalización/estadística & datos numéricos , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Factores de Tiempo , Anciano de 80 o más Años
2.
Europace ; 26(7)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38979560

RESUMEN

AIMS: Recommendations on cardiac resynchronization therapy (CRT) in patients with atrial fibrillation or flutter (AF) are based on less robust evidence than those in sinus rhythm (SR). We aimed to assess the efficacy of CRT upgrade in the BUDAPEST-CRT Upgrade trial population by their baseline rhythm. METHODS AND RESULTS: Heart failure patients with reduced ejection fraction (HFrEF) and previously implanted pacemaker (PM) or implantable cardioverter defibrillator (ICD) and ≥20% right ventricular (RV) pacing burden were randomized to CRT with defibrillator (CRT-D) upgrade (n = 215) or ICD (n = 145). Primary [HF hospitalization (HFH), all-cause mortality, or <15% reduction of left ventricular end-systolic volume] and secondary outcomes were investigated. At enrolment, 131 (36%) patients had AF, who had an increased risk for HFH as compared with those with SR [adjusted hazard ratio (aHR) 2.99; 95% confidence interval (CI) 1.26-7.13; P = 0.013]. The effect of CRT-D upgrade was similar in patients with AF as in those with SR [AF adjusted odds ratio (aOR) 0.06; 95% CI 0.02-0.17; P < 0.001; SR aOR 0.13; 95% CI 0.07-0.27; P < 0.001; interaction P = 0.29] during the mean follow-up time of 12.4 months. Also, it decreased the risk of HFH or all-cause mortality (aHR 0.33; 95% CI 0.16-0.70; P = 0.003; interaction P = 0.17) and improved the echocardiographic response (left ventricular end-diastolic volume difference -49.21 mL; 95% CI -69.10 to -29.32; P < 0.001; interaction P = 0.21). CONCLUSION: In HFrEF patients with AF and PM/ICD with high RV pacing burden, CRT-D upgrade decreased the risk of HFH and improved reverse remodelling when compared with ICD, similar to that seen in patients in SR.


Asunto(s)
Fibrilación Atrial , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Volumen Sistólico , Humanos , Fibrilación Atrial/terapia , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/mortalidad , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Masculino , Femenino , Terapia de Resincronización Cardíaca/métodos , Anciano , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/mortalidad , Resultado del Tratamiento , Persona de Mediana Edad , Función Ventricular Derecha , Función Ventricular Izquierda , Dispositivos de Terapia de Resincronización Cardíaca , Factores de Riesgo , Hospitalización/estadística & datos numéricos , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/instrumentación , Factores de Tiempo , Anciano de 80 o más Años
3.
Pacing Clin Electrophysiol ; 47(7): 893-901, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38884620

RESUMEN

BACKGROUND: To preserve the benefit of atrial sensing without the implantation of an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD) has been developed. The purpose of this nationwide survey was to provide an overview of the current key influences of device selection focusing on DX ICD and to test the applicability of a previously published decision-making flowchart of ICD-type selection. METHODS: An online questionnaire was sent to all implanting centers in Hungary. Eleven centers reported data from 361 DX ICD and 10 CRT-DX systems implantations between February 2021 and May 2023. RESULTS: The most important influencing clinical factors indicated by the participating doctors were elevated risk of atrial fibrillation (AF)/stroke (56%), risk of sinus/supraventricular tachycardias (SVT) (42%), and a potential need for CRT upgrade in the future (36%). The DX ICD was considered in the majority of cases instead of the VVI system (87%), and only in a small proportion instead of a DDD ICD (13%). 60% of the patients with DX ICDs were also included into remote monitoring-based follow-up. In 83% of the cases, good (>2 mV) or excellent (>5) atrial signal amplitude was recorded within 6 weeks after the implantation. CONCLUSION: In the current national survey, the most important influencing factors indicated by the implanters for selecting a DX ICD were the elevated risk of stroke or sinus/SVT and a potential need for CRT upgrade in the future. These findings support the use of a previously published decision-making flowchart.


Asunto(s)
Desfibriladores Implantables , Humanos , Estudios Prospectivos , Encuestas y Cuestionarios , Masculino , Femenino , Hungría , Fibrilación Atrial , Anciano , Persona de Mediana Edad
4.
Eur Heart J ; 44(40): 4259-4269, 2023 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-37632437

RESUMEN

BACKGROUND AND AIMS: De novo implanted cardiac resynchronization therapy with defibrillator (CRT-D) reduces the risk of morbidity and mortality in patients with left bundle branch block, heart failure and reduced ejection fraction (HFrEF). However, among HFrEF patients with right ventricular pacing (RVP), the efficacy of CRT-D upgrade is uncertain. METHODS: In this multicentre, randomized, controlled trial, 360 symptomatic (New York Heart Association Classes II-IVa) HFrEF patients with a pacemaker or implantable cardioverter defibrillator (ICD), high RVP burden ≥ 20%, and a wide paced QRS complex duration ≥ 150 ms were randomly assigned to receive CRT-D upgrade (n = 215) or ICD (n = 145) in a 3:2 ratio. The primary outcome was the composite of all-cause mortality, heart failure hospitalization, or <15% reduction of left ventricular end-systolic volume assessed at 12 months. Secondary outcomes included all-cause mortality or heart failure hospitalization. RESULTS: Over a median follow-up of 12.4 months, the primary outcome occurred in 58/179 (32.4%) in the CRT-D arm vs. 101/128 (78.9%) in the ICD arm (odds ratio 0.11; 95% confidence interval 0.06-0.19; P < .001). All-cause mortality or heart failure hospitalization occurred in 22/215 (10%) in the CRT-D arm vs. 46/145 (32%) in the ICD arm (hazard ratio 0.27; 95% confidence interval 0.16-0.47; P < .001). The incidence of procedure- or device-related complications was similar between the two arms [CRT-D group 25/211 (12.3%) vs. ICD group 11/142 (7.8%)]. CONCLUSIONS: In pacemaker or ICD patients with significant RVP burden and reduced ejection fraction, upgrade to CRT-D compared with ICD therapy reduced the combined risk of all-cause mortality, heart failure hospitalization, or absence of reverse remodelling.

5.
Europace ; 25(10)2023 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-37766466

RESUMEN

AIMS: This study aimed to investigate the impact of cardiac resynchronization therapy with a defibrillator (CRT-D) on mortality, comparing it with CRT with a pacemaker (CRT-P). Additionally, the study sought to identify subgroups, evaluate the time trend in treatment effects, and analyze patient characteristics, considering the changing indications over the past decades. METHODS AND RESULTS: PubMed, CENTRAL, and Embase up to October 2021 were screened for studies comparing CRT-P and CRT-D, focusing on mortality. Altogether 26 observational studies were selected comprising 128 030 CRT patients, including 55 469 with CRT-P and 72 561 with CRT-D device. Cardiac resynchronization therapy with defibrillator was able to reduce all-cause mortality by almost 20% over CRT-P [adjusted hazard ratio (HR): 0.85; 95% confidence interval (CI): 0.76-0.94; P < 0.01] even in propensity-matched studies (HR: 0.83; 95% CI: 0.80-0.87; P < 0.001) but not in those with non-ischaemic aetiology (HR: 0.95; 95% CI: 0.79-1.15; P = 0.19) or over 75 years (HR: 1.08; 95% CI 0.96-1.21; P = 0.17). When treatment effect on mortality was investigated by the median year of inclusion, there was a difference between studies released before 2015 and those thereafter. Time-trend effects could be also observed in patients' characteristics: CRT-P candidates were getting older and the prevalence of ischaemic aetiology was increasing over time. CONCLUSION: The results of this systematic review of observational studies, mostly retrospective with meta-analysis, suggest that patients with CRT-D had a lower risk of mortality compared with CRT-P. However, subgroups could be identified, where CRT-D was not superior such as non-ischaemic and older patients. An improved treatment effect of CRT-D on mortality could be observed between the early and late studies partly related to the changed characteristics of CRT candidates.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Terapia de Resincronización Cardíaca/métodos , Cardioversión Eléctrica/instrumentación , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Factores de Tiempo , Dispositivos de Terapia de Resincronización Cardíaca
6.
Cardiology ; 148(1): 27-37, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36470212

RESUMEN

INTRODUCTION: Hospitalization due to heart failure (HF) progression is associated with poor prognosis. This highlights the role of the implementation of guideline-directed medical therapy (GDMT) in improving the morbidity and mortality of patients with heart failure with reduced ejection fraction (HFrEF). There are limited data about the intrahospital applicability of GDMT in real-world circumstances. We aimed to assess retrospectively the use of cornerstone GDMT including RASi (ACEI/ARB/ARNI), ßB, MRA, and SGLT2i treatment in a consecutive real-world HFrEF patient population admitted with signs and symptoms of HF to the HF Unit of a Hungarian tertiary cardiac center between 2019 and 2021. The independent predictors of therapy optimization and the applicability of new HFrEF medication (ARNI, SGLT2i, vericiguat) were also investigated. METHODS: Statistical comparison of admission and discharge medication was accomplished with Fisher's exact test. The independent predictors of the introduction of triple therapy (RASi + ßB + MRA) were analyzed using univariate and multivariate logistic regression. The proportion of patients eligible for vericiguat based on the inclusion and exclusion criteria of the VICTORIA trial was also investigated, as well as the number of patients suitable for ARNI and SGLT2i, taking into account the contraindications of application contained in the ESC 2021 HF Guidelines. RESULTS: 238 patients were included. During hospitalization, the use of RASi (69% vs. 89%) (ACEI/ARBs [58% vs. 70%], ARNI [10% vs. 19%]), ßBs (69% vs. 85%), and MRAs (61% vs. 95%) increased significantly (p < 0.05) compared to at admission, and the use of SGLT2i (3% vs. 11%) also rose (p = 0.0005). The application ratio of triple (RASi + ßB + MRA; 43% vs. 77%) and quadruple (RASi + ßB + MRA + SGLT2i; 2% vs. 11%) therapy increased as well (p < 0.0001). The independent predictors of discharge application of triple therapy revealed through multivariate logistic regression analysis were age, duration of hospitalization, eGFR, NTproBNP, and presence of diabetes mellitus. Sixty-eight percent of the cohort would have been suitable for vericiguat, 83% for ARNI, and 84% for SGLT2i. CONCLUSION: High rates of application of disease-modifying drugs are achievable among hospitalized HFrEF patients in severe clinical condition; thus, awareness of the need for their initiation must be raised.


Asunto(s)
Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Humanos , Insuficiencia Cardíaca/tratamiento farmacológico , Antagonistas de Receptores de Angiotensina/uso terapéutico , Estudios Retrospectivos , Volumen Sistólico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Hospitalización , Disfunción Ventricular Izquierda/tratamiento farmacológico
7.
Heart Fail Rev ; 27(6): 2165-2176, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35670890

RESUMEN

Cardiac resynchronization therapy (CRT) may improve not only impaired left ventricular contractility but can also induce reverse remodeling of native conduction system. Measurement of intrinsic QRS complex width during follow-up is the simplest method to assess reverse electrical remodeling (RER). We aimed to provide a literature review and meta-analysis on incidence and impact of RER and its association with mechanical remodeling. A systematic review and random-effect meta-analysis of studies reporting data on RER was performed. A total of 16 studies were included in this meta-analysis with 930 patients undergoing CRT (mean age 64.0 years, 64.1% males). The weighted mean incidence of RER was 42%. Reverse mechanical remodeling assessed by echocardiography was more frequently observed in patients with RER compared to patients without RER (75.7% vs. 46.6%; odds ratio [OR] 3.7, 95% confidence interval [CI] 2.24-6.09, p < 0.01). Mechanical responders had a mean iQRS shortening of 7.7 ms, while mechanical non-responders experienced a mean widening of iQRS by 5.2 ms (p < 0.01). Clinical improvement was more frequent in patients with RER vs. patients without RER (82.9% vs. 49.0%; OR 5.26; 95% CI 2.92-9.48; p < 0.01). No significant difference in all-cause mortality between patients with and without RER was found. Mean difference between baseline intrinsic QRS and post-implantation paced QRS was significant in patients with later RER (21.2 ms, 95% CI 9.4-32.9, p < 0.01), but not in patients without RER (6.6 ms, 95% CI -2.2-15.4, p = 0.14). Gender, initial left bundle block morphology and heart failure etiology were found not to be predictive for RER. Our meta-analysis demonstrates that shortening of iQRS duration is a common finding during follow-up of patients undergoing CRT and is associated with mechanical reverse remodeling and clinical improvement. Clinical Trial Registration: Prospero Database-CRD42021253336.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Terapia de Resincronización Cardíaca/métodos , Electrocardiografía/métodos , Femenino , Sistema de Conducción Cardíaco , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Remodelación Ventricular
8.
J Cardiovasc Electrophysiol ; 31(7): 1784-1792, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32412126

RESUMEN

INTRODUCTION: The novel two-lead cardiac resynchronization therapy (CRT)-DX system utilizes a floating atrial dipole on the implantable cardioverter-defibrillator lead, and when implanted with a left ventricular (LV) lead, offers a two-lead CRT system with AV synchrony. This study compared complication rates and CRT response among subjects implanted with a two-lead CRT-DX system to those subjects implanted with a standard three-lead CRT-D system. METHODS AND RESULTS: A total of 240 subjects from the Sentus QP-Extended CRT Evaluation with Quadripolar Left Ventricular Leads postapproval study were selected to identify 120 matched pairs based on similar demographic characteristics using a Greedy algorithm. The complication-free rate was evaluated as the primary endpoint. All-cause mortality, heart failure hospitalizations, device diagnostic data, New York Heart Association (NYHA) class improvement, and defibrillator therapy were evaluated from clinical data, in-office interrogations, and remote monitoring throughout the follow-up period. Complication-free survival favored the CRT-DX group with 92.5% without a major complication compared to 85.0% in the CRT-D cohort (P = .0495; 95% confidence interval: 0.1%-14.9%) over a mean follow-up of 1.3 and 1.4 years, respectively. Incidence of all-cause mortality, heart failure hospitalizations, NYHA changes at 6 months postimplant, and percent of LV pacing during CRT therapy were similar in both device cohorts. Inappropriate shocks were more frequent in the CRT-D cohort with 5.8% of subjects receiving an inappropriate shock vs 0.8% in the CRT-DX cohort. CONCLUSION: The results of this subanalysis demonstrate that the CRT-DX system can provide similar CRT responses and significantly fewer complications when compared to a similar cohort with a conventional three-lead CRT-D system.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables/efectos adversos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , New York , Sistema de Registros , Resultado del Tratamiento
9.
N Engl J Med ; 374(6): 533-41, 2016 Feb 11.
Artículo en Inglés | MEDLINE | ID: mdl-26551877

RESUMEN

BACKGROUND: A leadless intracardiac transcatheter pacing system has been designed to avoid the need for a pacemaker pocket and transvenous lead. METHODS: In a prospective multicenter study without controls, a transcatheter pacemaker was implanted in patients who had guideline-based indications for ventricular pacing. The analysis of the primary end points began when 300 patients reached 6 months of follow-up. The primary safety end point was freedom from system-related or procedure-related major complications. The primary efficacy end point was the percentage of patients with low and stable pacing capture thresholds at 6 months (≤2.0 V at a pulse width of 0.24 msec and an increase of ≤1.5 V from the time of implantation). The safety and efficacy end points were evaluated against performance goals (based on historical data) of 83% and 80%, respectively. We also performed a post hoc analysis in which the rates of major complications were compared with those in a control cohort of 2667 patients with transvenous pacemakers from six previously published studies. RESULTS: The device was successfully implanted in 719 of 725 patients (99.2%). The Kaplan-Meier estimate of the rate of the primary safety end point was 96.0% (95% confidence interval [CI], 93.9 to 97.3; P<0.001 for the comparison with the safety performance goal of 83%); there were 28 major complications in 25 of 725 patients, and no dislodgements. The rate of the primary efficacy end point was 98.3% (95% CI, 96.1 to 99.5; P<0.001 for the comparison with the efficacy performance goal of 80%) among 292 of 297 patients with paired 6-month data. Although there were 28 major complications in 25 patients, patients with transcatheter pacemakers had significantly fewer major complications than did the control patients (hazard ratio, 0.49; 95% CI, 0.33 to 0.75; P=0.001). CONCLUSIONS: In this historical comparison study, the transcatheter pacemaker met the prespecified safety and efficacy goals; it had a safety profile similar to that of a transvenous system while providing low and stable pacing thresholds. (Funded by Medtronic; Micra Transcatheter Pacing Study ClinicalTrials.gov number, NCT02004873.).


Asunto(s)
Arritmias Cardíacas/terapia , Marcapaso Artificial , Adulto , Anciano , Anciano de 80 o más Años , Electrodos Implantados , Diseño de Equipo , Seguridad de Equipos , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Adulto Joven
10.
Europace ; 21(11): 1686-1693, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31681964

RESUMEN

AIMS: Patient selection is a key component of securing optimal patient outcomes with leadless pacing. We sought to describe and compare patient characteristics and outcomes of Micra patients with and without a primary pacing indication associated with atrial fibrillation (AF) in the Micra IDE trial. METHODS AND RESULTS: The primary outcome (risk of cardiac failure, pacemaker syndrome, or syncope related to the Micra system or procedure) was compared between successfully implanted patients from the Micra IDE trial with a primary pacing indication associated with AF or history of AF (AF group) and those without (non-AF group). Among 720 patients successfully implanted with Micra, 228 (31.7%) were in the non-AF group. Reasons for selecting VVI pacing in non-AF patients included an expectation for infrequent pacing (66.2%) and advanced age (27.2%). More patients in the non-AF group had a condition that precluded the use of a transvenous pacemaker (9.6% vs. 4.7%, P = 0.013). Atrial fibrillation patients programmed to VVI received significantly more ventricular pacing compared to non-AF patients (median 67.8% vs. 12.6%; P < 0.001). The overall occurrence of the composite outcome at 24 months was 1.8% with no difference between the AF and non-AF groups (hazard ratio 1.36, 95% confidence interval 0.45-4.2; P = 0.59). CONCLUSION: Nearly one-third of patients selected to receive Micra VVI therapy were for indications not associated with AF. Non-AF VVI patients required less frequent pacing compared to patients with AF. Risks associated with VVI therapy were low and did not differ in those with and without AF.


Asunto(s)
Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial/métodos , Ventrículos Cardíacos/fisiopatología , Marcapaso Artificial , Selección de Paciente , Anciano , Fibrilación Atrial/fisiopatología , Diseño de Equipo , Femenino , Humanos , Masculino , Estudios Prospectivos , Resultado del Tratamiento
11.
J Med Internet Res ; 21(7): e14142, 2019 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-31350836

RESUMEN

BACKGROUND: Remote monitoring is an established, guideline-recommended technology with unequivocal clinical benefits; however, its ability to improve survival is contradictory. OBJECTIVE: The aim of our study was to investigate the effects of remote monitoring on mortality in an optimally treated heart failure patient population undergoing cardiac resynchronization defibrillator therapy (CRT-D) implantation in a large-volume tertiary referral center. METHODS: The population of this single-center, retrospective, observational study included 231 consecutive patients receiving CRT-D devices in the Medical Centre of the Hungarian Defence Forces (Budapest, Hungary) from January 2011 to June 2016. Clinical outcomes were compared between patients on remote monitoring and conventional follow-up. RESULTS: The mean follow-up time was 28.4 (SD 18.1) months. Patients on remote monitoring were more likely to have atrial fibrillation, received heart failure management at our dedicated heart failure outpatient clinic more often, and have a slightly lower functional capacity. Crude all-cause mortality of remote-monitored patients was significantly lower compared with patients followed conventionally (hazard ratio [HR] 0.368, 95% CI 0.186-0.727, P=.004). The survival benefit remained statistically significant after adjustment for important baseline parameters (adjusted HR 0.361, 95% CI 0.181-0.722, P=.004). CONCLUSIONS: In this single-center, retrospective study of optimally treated heart failure patients undergoing CRT-D implantation, the use of remote monitoring systems was associated with a significantly better survival rate.


Asunto(s)
Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/terapia , Telemedicina/métodos , Anciano , Terapia de Resincronización Cardíaca/métodos , Femenino , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
12.
J Cardiovasc Electrophysiol ; 29(12): 1690-1696, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30176097

RESUMEN

INTRODUCTION: The Micra Transcatheter Pacing System provides a rate adaptive pacing using an individually programmable three-axis accelerometer. We evaluated the short- and mid-term performance of the Micra activity sensor by testing all three available activity vectors during the exercise tests. METHODS AND RESULTS: Implantation and follow-up data were prospectively collected from the patients undergoing Micra implantation at our institution. Patients underwent a 5-minute exercise test for each vector at predischarge (initial testing) and at scheduled in-office visits (repeat testing). On the basis of measurements of activity counts during the test, vectors were categorized to be adequate (excellent or acceptable) or poor. A total of 278 tests with 818 vector measurements were analyzed in 51 patients during follow-up (median duration was 18 months). Initial testing revealed the adequate quality of the nominal Vector 1 in 74.5% of the patients. Upon repeated testing at subsequent in-office visits, Vectors 1 and 3 were comparable (adequate quality in 64.7% vs 68.6% of the patients; P = 0.65) but better compared with Vector 2 (51.0%; P = 0.10 vs Vector 1, P = 0.01 vs Vector 3). In a subgroup of 45 patients programmed to VVIR mode, Vector 1 was selected in 46.7% of the patients after the initial test (Vector 2, 8.9%; Vector 3, 44.4%). Vector change was performed in 10 patients (22.2%) following repeated tests within 3 months of postimplantation. CONCLUSION: The three-axis accelerometer-based rate adaptive pacing feature proved to be feasible after manual selection of an adequate activity vector. Vector testing in Micra patients with chronotropic incompetence appears to be beneficial compared with the use of nominal Vector 1.


Asunto(s)
Acelerometría/instrumentación , Arritmias Cardíacas/fisiopatología , Estimulación Cardíaca Artificial , Diseño de Equipo/instrumentación , Ejercicio Físico/fisiología , Marcapaso Artificial , Acelerometría/métodos , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirugía , Estimulación Cardíaca Artificial/métodos , Diseño de Equipo/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos
13.
Heart Fail Rev ; 23(1): 15-26, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29047028

RESUMEN

Patients with conventional pacemakers or implanted defibrillators are often considered for cardiac resynchronization therapy (CRT). Our aim was to summarize the available evidences regarding the clinical benefits of upgrade procedures. A systematic literature search was performed from studies published between 2006 and 2017 in order to compare the outcome of CRT upgrade vs. de novo implantations. Outcome data on all-cause mortality, heart failure events, New York Heart Association (NYHA) Class, QRS narrowing and echocardiographic parameters were analysed. A total of 16 reports were analysed comprising 489,568 CRT recipients, of whom 468,205 patients underwent de novo and 21,363 upgrade procedures. All-cause mortality was similar after CRT upgrade compared to de novo implantations (RR 1.19, 95% CI 0.88-1.60, p = 0.27). The risk of heart failure was also similar in both groups (RR 0.96, 95% CI 0.70-1.32, p = 0.81). There was no significant difference in clinical response after CRT upgrade compared to de novo implantations in terms of improvement in left ventricular ejection fraction (ΔEF de novo - 6.85% vs. upgrade - 9.35%; p = 0.235), NYHA class (ΔNYHA de novo - 0.74 vs. upgrade - 0.70; p = 0.737) and QRS narrowing (ΔQRS de novo - 9.6 ms vs. upgrade - 29.5 ms; p = 0.485). Our systematic review and meta-analysis of currently available studies reports that CRT upgrade is associated with similar risk for all-cause mortality compared to de novo resynchronization therapy. Benefits on reverse remodelling and functional capacity improved similarly in both groups suggesting that CRT upgrade may be safely and effectively offered in routine practice. CLINICAL TRIAL REGISTRATION: Prospero Database-CRD42016043747.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Función Ventricular Izquierda/fisiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Resultado del Tratamiento
14.
Orv Hetil ; 159(28): 1135-1145, 2018 Jul.
Artículo en Húngaro | MEDLINE | ID: mdl-29983108

RESUMEN

Atrial fibrillation affects approximately three percent of the adults. Ablation strategies targeting the isolation of the pulmonary veins are the up-to-date cornerstones for atrial fibrillation ablations. However, a one-year success rate of repeated interventions is not more than 70%. Long-term efficacy of catheter ablation is presumably limited by electrical and structural remodeling of the atria, which results in a progressive increase in the duration of atrial fibrillation to become sustained. The potential pathophysiological importance of the epicardial adipose tissue, atrial fibrosis, autonomic nervous system and arrhythmogenic foci are documented by several studies. Increased volume, inflammation induced transformation to fibrosis and myocardial infiltration of atrial subepicardial fat in obese patients result in higher risk of atrial fibrillation development. Changes in atrial autonomic innervation under some conditions including regular physical exercise strongly promote arrhythmogenesis via the mechanism of enhanced triggered activity or abbreviated atrial refractoriness. Individualized management of possible trigger and substrate mechanisms are proposed to provide a novel basis for the effective treatment of atrial fibrillation. Pro-fibrotic signalling pathways can be inhibited by the suppression of renin-angiotensin-aldosterone system. Neuromodulation strategies include renal sympathetic denervation and ganglionic plexi ablation. Anticoagulation therapy has also been shown to reduce the burden of abnormal atrial remodeling. Possible novel catheter ablation techniques are used for right or left atrial linear lesions, scar homogenization and catheter ablation of complex fractionated atrial electrograms, rotors or ectopic foci. Beside these new management strategies, clinical consideration of factors of particular risks as obesity, hyperlipidaemia, hypertension, diabetes and obstructive sleep apnoe are also essential. Orv Hetil. 2018; 159(28): 1135-1145.


Asunto(s)
Técnicas de Ablación/métodos , Fibrilación Atrial/terapia , Ablación por Catéter/métodos , Medicina de Precisión/métodos , Fibrilación Atrial/fisiopatología , Humanos
15.
J Cardiovasc Electrophysiol ; 28(3): 336-346, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27925339

RESUMEN

INTRODUCTION: Two leadless pacemaker (PM) systems were recently developed to avoid pocket- and lead-related complications. As leadless PMs are implanted with a large delivery catheter, cardiac perforation remains a major safety concern. We aimed to provide a literature review on incidence of cardiac perforation with conventional and with leadless PM systems. METHODS AND RESULTS: A systematic review over the last 25 years for studies reporting data on PM lead perforation was performed. Findings were synthesized descriptively. Where control groups were available, data were meta-analyzed to identify important clinical risk factors. A total of 28 studies comprising 60,744 patients undergoing conventional PM implantation were analyzed. The incidence of lead perforation ranged from 0% to 6.37% (mean 0.82%, weighted mean 0.31%, median of 0.40%). There was no significant difference in perforation risk between atrial and ventricular electrodes (POR 0.72, 95% confidence interval [CI], 0.28-1.87, P = 0.50) and between MRI conditional and conventional leads (POR 5.93, 95% CI, 0.72-48.76, P = 0.10). The use of active fixation leads (POR 4.25, 95% CI, 1.00-17.95, P = 0.05) and utilization of DDD versus VVI PM systems (POR 3.50, 95% CI, 1.48-8.28, P < 0.01) were associated with higher rates of perforation. In the 2 leadless PM studies, the incidence of cardiac perforation was 1.52% for each. CONCLUSION: PM lead perforation rates vary in individual studies with an overall low incidence. Leadless PMs seem to be associated with a slightly higher perforation risk, most likely reflecting a learning curve effect of this novel technology.


Asunto(s)
Estimulación Cardíaca Artificial , Lesiones Cardíacas/epidemiología , Marcapaso Artificial/efectos adversos , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Lesiones Cardíacas/diagnóstico , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Oportunidad Relativa , Medición de Riesgo , Factores de Riesgo , Resultado del Tratamiento
16.
Europace ; 19(9): 1549-1555, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28339581

RESUMEN

AIMS: There is lack of conclusive evidence from randomized clinical trials on the efficacy and safety of upgrade to cardiac resynchronization therapy (CRT) in patients with implanted pacemakers (PM) or defibrillators (ICD) with reduced left ventricular ejection fraction (LVEF) and chronic heart failure (HF). The BUDAPEST-CRT Upgrade Study was designed to compare the efficacy and safety of CRT upgrade from conventional PM or ICD therapy in patients with intermittent or permanent right ventricular (RV) septal/apical pacing, reduced LVEF, and symptomatic HF. METHODS AND RESULTS: The BUDAPEST-CRT study is a prospective, randomized, multicentre, investigator-sponsored clinical trial. A total of 360 subjects will be enrolled with LVEF ≤ 35%, NYHA functional classes II-IVa, paced QRS ≥ 150 ms, and a RV pacing ≥ 20%. Patients will be followed for 12 months. Randomization is performed in a 3:2 ratio (CRT-D vs. ICD). The primary composite endpoint is all-cause mortality, a first HF event, or less than 15% reduction in left ventricular (LV) end-systolic volume at 12 months. Secondary endpoints are all-cause mortality, all-cause mortality or HF event, and LV volume reduction at 12 months. Tertiary endpoints include changes in quality of life, NYHA functional class, 6 min walk test, natriuretic peptides, and safety outcomes. CONCLUSION: The results of our prospective, randomized, multicentre clinical trial will provide important information on the role of cardiac resynchronization therapy with defibrillator (CRT-D) upgrade in patients with symptomatic HF, reduced LVEF, and wide-paced QRS with intermittent or permanent RV pacing. CLINICAL TRIALS.GOV IDENTIFIER: NCT02270840.


Asunto(s)
Estimulación Cardíaca Artificial , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Insuficiencia Cardíaca/terapia , Marcapaso Artificial , Volumen Sistólico , Función Ventricular Izquierda , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/mortalidad , Terapia de Resincronización Cardíaca/efectos adversos , Terapia de Resincronización Cardíaca/mortalidad , Enfermedad Crónica , Protocolos Clínicos , Remoción de Dispositivos , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Europa (Continente) , Tolerancia al Ejercicio , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Israel , Estudios Prospectivos , Recuperación de la Función , Proyectos de Investigación , Factores de Tiempo , Resultado del Tratamiento , Prueba de Paso
17.
Pacing Clin Electrophysiol ; 40(7): 834-842, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28439940

RESUMEN

BACKGROUND: Leadless pacemaker systems have been designed to avoid the need for a pocket and transvenous lead. However, delivery of this therapy requires a new catheter-based procedure. This study evaluates the role of operator experience and different training strategies on procedural outcomes. METHODS: A total of 726 patients underwent implant attempt with the Micra transcatheter pacing system (TPS; Medtronic, Minneapolis, MN, USA) by 94 operators trained in a teaching laboratory using a simulator, cadaver, and large animal models (lab training) or locally at the hospital with simulator/demo model and proctorship (hospital training). Procedure success, procedure duration, fluoroscopy time, and safety outcomes were compared between training methods and experience (implant case number). RESULTS: The Micra TPS procedure was successful in 99.2% of attempts and did not differ between the 55 operators trained in the lab setting and the 39 operators trained locally at the hospital (P = 0.189). Implant case number was also not a determinant of procedural success (P = 0.456). Each operator performed between one and 55 procedures. Procedure time and fluoroscopy duration decreased by 2.0% (P = 0.002) and 3.2% (P < 0.001) compared to the previous case. Major complication rate and pericardial effusion rate were not associated with case number (P = 0.755 and P = 0.620, respectively). There were no differences in the safety outcomes by training method. CONCLUSIONS: Among a large group of operators, implantation success was high regardless of experience. While procedure duration and fluoroscopy times decreased with implant number, complications were low and not associated with case number. Procedure and safety outcomes were similar between distinct training methodologies.


Asunto(s)
Arritmias Cardíacas/terapia , Catéteres Cardíacos , Estimulación Cardíaca Artificial/métodos , Competencia Clínica , Anciano , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Marcapaso Artificial , Seguridad del Paciente , Resultado del Tratamiento
18.
J Cardiovasc Electrophysiol ; 27(12): 1495-1501, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27600684

RESUMEN

Two major studies have shown that leadless pacemakers are safe and effective for patients requiring right ventricular rate responsive pacing therapy. This positive result recently led to FDA approval of one of the available leadless pacing devices. While this new technology is promising, it requires a different skill set for safe implantation. In this article, we review in detail the different steps required for implantation of tine-based leadless pacemakers while providing tips and tricks to minimize complications.


Asunto(s)
Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Estimulación Cardíaca Artificial , Marcapaso Artificial , Diseño de Equipo , Humanos , Radiografía Intervencional , Resultado del Tratamiento
19.
Ann Noninvasive Electrocardiol ; 21(2): 161-8, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26105057

RESUMEN

BACKGROUND: In coronary artery disease (CAD), body surface potential mapping (BSPM) may reveal minor electrical potential changes appearing in the depolarization phase even if pathological changes are absent on the conventional 12-lead ECG. We hypothesized that a simple BSPM parameter, Max/Min signifies successful percutaneous coronary intervention (PCI). METHODS: Ninety-two adult Caucasian patients with stable CAD and positive exercise test underwent coronary angiography. Seventy patients (age, 59 ± 8; 46 males) were revascularized by PCI (left anterior descending [LAD] in 38, right [RCA] in 17 and left circumflex [LCX] coronary artery in 15). Control groups contained 22 patients (age, 60 ± 8; 14 males) without intervention and 35 healthy subjects (age, 58 ± 2; 15 males). Left ventricular ejection fraction (LVEF, transthoracic echocardiography) and Max/Min BSPM parameter (63-lead Montreal system) were evaluated before and 4-40 days following coronary angiography. Max/Min was defined by the ratio of the highest maximum to the deepest minimum potential of all leads recorded by BSPM. RESULTS: Before PCI, Max/Min value of patients with LAD lesion (0.83 [0.74; 0.93]) was significantly lower while that with RCA lesion (1.63 [1.35; 1.99]) was significantly higher than that of healthy group (1.01 [0.970; 1.13]) (P < 0.05) and LVEF was significantly lower in LAD lesion (46.50% [43.00; 51.00]) than in the healthy group (55.00% [50.00; 58.75]) (P < 0.01). Max/Min value significantly increased from 0.83 [0.74; 0.93] to 0.92 [0.82; 0.99] (P < 0.01) following LAD PCI while significantly decreased from 1.63 [1.35; 1.98] to 1.35 [1.21; 1.43] (P < 0.01) post-RCA PCI. It did not vary significantly, however, either following LCX PCI or without intervention. LVEF significantly increased (from 46.50% [43.00; 51.00] to 49.00% [46.00; 51.00]) only after LAD PCI. CONCLUSION: Max/Min parameter is suitable to follow patients after LAD and RCA PCI.


Asunto(s)
Mapeo del Potencial de Superficie Corporal/métodos , Mapeo del Potencial de Superficie Corporal/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/estadística & datos numéricos , Electrocardiografía/métodos , Electrocardiografía/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad
20.
Eur Heart J ; 36(37): 2510-9, 2015 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-26045305

RESUMEN

AIMS: Permanent cardiac pacing is the only effective treatment for symptomatic bradycardia, but complications associated with conventional transvenous pacing systems are commonly related to the pacing lead and pocket. We describe the early performance of a novel self-contained miniaturized pacemaker. METHODS AND RESULTS: Patients having Class I or II indication for VVI pacing underwent implantation of a Micra transcatheter pacing system, from the femoral vein and fixated in the right ventricle using four protractible nitinol tines. Prespecified objectives were >85% freedom from unanticipated serious adverse device events (safety) and <2 V 3-month mean pacing capture threshold at 0.24 ms pulse width (efficacy). Patients were implanted (n = 140) from 23 centres in 11 countries (61% male, age 77.0 ± 10.2 years) for atrioventricular block (66%) or sinus node dysfunction (29%) indications. During mean follow-up of 1.9 ± 1.8 months, the safety endpoint was met with no unanticipated serious adverse device events. Thirty adverse events related to the system or procedure occurred, mostly due to transient dysrhythmias or femoral access complications. One pericardial effusion without tamponade occurred after 18 device deployments. In 60 patients followed to 3 months, mean pacing threshold was 0.51 ± 0.22 V, and no threshold was ≥2 V, meeting the efficacy endpoint (P < 0.001). Average R-wave was 16.1 ± 5.2 mV and impedance was 650.7 ± 130 ohms. CONCLUSION: Early assessment shows the transcatheter pacemaker can safely and effectively be applied. Long-term safety and benefit of the pacemaker will further be evaluated in the trial. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov ID NCT02004873.


Asunto(s)
Bloqueo Atrioventricular/terapia , Marcapaso Artificial , Síndrome del Seno Enfermo/terapia , Anciano , Electrocardiografía Ambulatoria , Femenino , Humanos , Masculino , Microelectrodos , Tempo Operativo , Seguridad del Paciente , Estudios Prospectivos , Diseño de Prótesis , Implantación de Prótesis/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA