Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Cardiology ; 148(1): 27-37, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36470212

RESUMEN

INTRODUCTION: Hospitalization due to heart failure (HF) progression is associated with poor prognosis. This highlights the role of the implementation of guideline-directed medical therapy (GDMT) in improving the morbidity and mortality of patients with heart failure with reduced ejection fraction (HFrEF). There are limited data about the intrahospital applicability of GDMT in real-world circumstances. We aimed to assess retrospectively the use of cornerstone GDMT including RASi (ACEI/ARB/ARNI), ßB, MRA, and SGLT2i treatment in a consecutive real-world HFrEF patient population admitted with signs and symptoms of HF to the HF Unit of a Hungarian tertiary cardiac center between 2019 and 2021. The independent predictors of therapy optimization and the applicability of new HFrEF medication (ARNI, SGLT2i, vericiguat) were also investigated. METHODS: Statistical comparison of admission and discharge medication was accomplished with Fisher's exact test. The independent predictors of the introduction of triple therapy (RASi + ßB + MRA) were analyzed using univariate and multivariate logistic regression. The proportion of patients eligible for vericiguat based on the inclusion and exclusion criteria of the VICTORIA trial was also investigated, as well as the number of patients suitable for ARNI and SGLT2i, taking into account the contraindications of application contained in the ESC 2021 HF Guidelines. RESULTS: 238 patients were included. During hospitalization, the use of RASi (69% vs. 89%) (ACEI/ARBs [58% vs. 70%], ARNI [10% vs. 19%]), ßBs (69% vs. 85%), and MRAs (61% vs. 95%) increased significantly (p < 0.05) compared to at admission, and the use of SGLT2i (3% vs. 11%) also rose (p = 0.0005). The application ratio of triple (RASi + ßB + MRA; 43% vs. 77%) and quadruple (RASi + ßB + MRA + SGLT2i; 2% vs. 11%) therapy increased as well (p < 0.0001). The independent predictors of discharge application of triple therapy revealed through multivariate logistic regression analysis were age, duration of hospitalization, eGFR, NTproBNP, and presence of diabetes mellitus. Sixty-eight percent of the cohort would have been suitable for vericiguat, 83% for ARNI, and 84% for SGLT2i. CONCLUSION: High rates of application of disease-modifying drugs are achievable among hospitalized HFrEF patients in severe clinical condition; thus, awareness of the need for their initiation must be raised.


Asunto(s)
Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Humanos , Insuficiencia Cardíaca/tratamiento farmacológico , Antagonistas de Receptores de Angiotensina/uso terapéutico , Estudios Retrospectivos , Volumen Sistólico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Hospitalización , Disfunción Ventricular Izquierda/tratamiento farmacológico
2.
J Med Internet Res ; 21(7): e14142, 2019 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-31350836

RESUMEN

BACKGROUND: Remote monitoring is an established, guideline-recommended technology with unequivocal clinical benefits; however, its ability to improve survival is contradictory. OBJECTIVE: The aim of our study was to investigate the effects of remote monitoring on mortality in an optimally treated heart failure patient population undergoing cardiac resynchronization defibrillator therapy (CRT-D) implantation in a large-volume tertiary referral center. METHODS: The population of this single-center, retrospective, observational study included 231 consecutive patients receiving CRT-D devices in the Medical Centre of the Hungarian Defence Forces (Budapest, Hungary) from January 2011 to June 2016. Clinical outcomes were compared between patients on remote monitoring and conventional follow-up. RESULTS: The mean follow-up time was 28.4 (SD 18.1) months. Patients on remote monitoring were more likely to have atrial fibrillation, received heart failure management at our dedicated heart failure outpatient clinic more often, and have a slightly lower functional capacity. Crude all-cause mortality of remote-monitored patients was significantly lower compared with patients followed conventionally (hazard ratio [HR] 0.368, 95% CI 0.186-0.727, P=.004). The survival benefit remained statistically significant after adjustment for important baseline parameters (adjusted HR 0.361, 95% CI 0.181-0.722, P=.004). CONCLUSIONS: In this single-center, retrospective study of optimally treated heart failure patients undergoing CRT-D implantation, the use of remote monitoring systems was associated with a significantly better survival rate.


Asunto(s)
Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/terapia , Telemedicina/métodos , Anciano , Terapia de Resincronización Cardíaca/métodos , Femenino , Insuficiencia Cardíaca/mortalidad , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento
3.
J Cardiovasc Electrophysiol ; 29(12): 1690-1696, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30176097

RESUMEN

INTRODUCTION: The Micra Transcatheter Pacing System provides a rate adaptive pacing using an individually programmable three-axis accelerometer. We evaluated the short- and mid-term performance of the Micra activity sensor by testing all three available activity vectors during the exercise tests. METHODS AND RESULTS: Implantation and follow-up data were prospectively collected from the patients undergoing Micra implantation at our institution. Patients underwent a 5-minute exercise test for each vector at predischarge (initial testing) and at scheduled in-office visits (repeat testing). On the basis of measurements of activity counts during the test, vectors were categorized to be adequate (excellent or acceptable) or poor. A total of 278 tests with 818 vector measurements were analyzed in 51 patients during follow-up (median duration was 18 months). Initial testing revealed the adequate quality of the nominal Vector 1 in 74.5% of the patients. Upon repeated testing at subsequent in-office visits, Vectors 1 and 3 were comparable (adequate quality in 64.7% vs 68.6% of the patients; P = 0.65) but better compared with Vector 2 (51.0%; P = 0.10 vs Vector 1, P = 0.01 vs Vector 3). In a subgroup of 45 patients programmed to VVIR mode, Vector 1 was selected in 46.7% of the patients after the initial test (Vector 2, 8.9%; Vector 3, 44.4%). Vector change was performed in 10 patients (22.2%) following repeated tests within 3 months of postimplantation. CONCLUSION: The three-axis accelerometer-based rate adaptive pacing feature proved to be feasible after manual selection of an adequate activity vector. Vector testing in Micra patients with chronotropic incompetence appears to be beneficial compared with the use of nominal Vector 1.


Asunto(s)
Acelerometría/instrumentación , Arritmias Cardíacas/fisiopatología , Estimulación Cardíaca Artificial , Diseño de Equipo/instrumentación , Ejercicio Físico/fisiología , Marcapaso Artificial , Acelerometría/métodos , Anciano , Anciano de 80 o más Años , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirugía , Estimulación Cardíaca Artificial/métodos , Diseño de Equipo/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos
4.
Heart Fail Rev ; 23(1): 15-26, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29047028

RESUMEN

Patients with conventional pacemakers or implanted defibrillators are often considered for cardiac resynchronization therapy (CRT). Our aim was to summarize the available evidences regarding the clinical benefits of upgrade procedures. A systematic literature search was performed from studies published between 2006 and 2017 in order to compare the outcome of CRT upgrade vs. de novo implantations. Outcome data on all-cause mortality, heart failure events, New York Heart Association (NYHA) Class, QRS narrowing and echocardiographic parameters were analysed. A total of 16 reports were analysed comprising 489,568 CRT recipients, of whom 468,205 patients underwent de novo and 21,363 upgrade procedures. All-cause mortality was similar after CRT upgrade compared to de novo implantations (RR 1.19, 95% CI 0.88-1.60, p = 0.27). The risk of heart failure was also similar in both groups (RR 0.96, 95% CI 0.70-1.32, p = 0.81). There was no significant difference in clinical response after CRT upgrade compared to de novo implantations in terms of improvement in left ventricular ejection fraction (ΔEF de novo - 6.85% vs. upgrade - 9.35%; p = 0.235), NYHA class (ΔNYHA de novo - 0.74 vs. upgrade - 0.70; p = 0.737) and QRS narrowing (ΔQRS de novo - 9.6 ms vs. upgrade - 29.5 ms; p = 0.485). Our systematic review and meta-analysis of currently available studies reports that CRT upgrade is associated with similar risk for all-cause mortality compared to de novo resynchronization therapy. Benefits on reverse remodelling and functional capacity improved similarly in both groups suggesting that CRT upgrade may be safely and effectively offered in routine practice. CLINICAL TRIAL REGISTRATION: Prospero Database-CRD42016043747.


Asunto(s)
Terapia de Resincronización Cardíaca/métodos , Insuficiencia Cardíaca/terapia , Función Ventricular Izquierda/fisiología , Insuficiencia Cardíaca/fisiopatología , Humanos , Resultado del Tratamiento
5.
Diagnostics (Basel) ; 14(2)2024 Jan 06.
Artículo en Inglés | MEDLINE | ID: mdl-38248008

RESUMEN

(1) Background: Besides the use of guideline-directed medical therapy (GDMT), multidisciplinary heart failure (HF) outpatient care (HFOC) is of strategic importance in HFrEF. (2) Methods: Data from 257 hospitalised HFrEF patients between 2019 and 2021 were retrospectively analysed. Application and target doses of GDMT were compared between HFOC and non-HFOC patients at discharge and at 1 year. 1-year all-cause mortality (ACM) and rehospitalisation (ACH) rates were compared using the Cox proportional hazard model. The effect of HFOC on GDMT and on prognosis after propensity score matching (PSM) of 168 patients and the independent predictors of 1-year ACM and ACH were also evaluated. (3) Results: At 1 year, the application of RASi, MRA and triple therapy (TT: RASi + ßB + MRA) was higher (p < 0.05) in the HFOC group, as was the proportion of target doses of ARNI, ßB, MRA and TT. After PSM, the composite of 1-year ACM or ACH was more favourable with HFOC (propensity-adjusted HR = 0.625, 95% CI = 0.401-0.974, p = 0.038). Independent predictors of 1-year ACM were age, systolic blood pressure, application of TT and HFOC, while 1-year ACH was influenced by the application of TT. (4) Conclusions: HFOC may positively impact GDMT use and prognosis in HFrEF even within the first year of its initiation.

6.
Clin Cardiol ; 47(2): e24244, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38402552

RESUMEN

BACKGROUND: Kidney dysfunction (KD) is a main limiting factor of applying guideline-directed medical therapy (GDMT) and reaching the recommended target doses (TD) in heart failure (HF) with reduced ejection fraction (HFrEF). HYPOTHESIS: We aimed to assess the success of optimization, long-term applicability, and adherence of neurohormonal antagonist triple therapy (TT:RASi [ACEi/ARB/ARNI] + ßB + MRA) according to the KD after a HF hospitalization and to investigate its impact on prognosis. METHODS: The data of 247 real-world, consecutive patients were analyzed who were hospitalized in 2019-2021 for HFrEF and then were followed-up for 1 year. The application and the ratio of reached TD of TT at hospital discharge and at 1 year were assessed comparing KD categories (eGFR: ≥90, 60-89, 45-59, 30-44, <30 mL/min/1.73 m2 ). Moreover, 1-year all-cause mortality and rehospitalization rates in KD subgroups were investigated. RESULTS: Majority of the patients received TT at hospital discharge (77%) and at 1 year (73%). More severe KD led to a lower application ratio (p < .05) of TT (92%, 88%, 80%, 73%, 31%) at discharge and at 1 year (81%, 76%, 76%, 68%, 40%). Patients with more severe KD were less likely (p < .05) to receive TD of MRA (81%, 68%, 78%, 61%, 52%) at discharge and a RASi (53%, 49%, 45%, 21%, 27%) at 1 year. One-year all-cause mortality (14%, 15%, 16%, 33%, 48%, p < .001), the ratio of all-cause rehospitalizations (30%, 35%, 40%, 43%, 52%, p = .028), and rehospitalizations for HF (8%, 13%, 18%, 20%, 38%, p = .001) were significantly higher in more severe KD categories. CONCLUSIONS: KD unfavorably affects the application of TT in HFrEF, however poorer mortality and rehospitalization rates among them highlight the role of the conscious implementation and up-titration of GDMT.


Asunto(s)
Insuficiencia Cardíaca , Humanos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/tratamiento farmacológico , Antagonistas de Receptores de Angiotensina , Volumen Sistólico , Inhibidores de la Enzima Convertidora de Angiotensina , Pronóstico , Riñón
7.
Orv Hetil ; 164(35): 1387-1396, 2023 Sep 03.
Artículo en Húngaro | MEDLINE | ID: mdl-37660348

RESUMEN

INTRODUCTION: Renal dysfunction is a main limiting factor of applying and up-titrating guideline-directed medical therapy (GDMT) among patients with heart failure with reduced ejection fraction (HFrEF). OBJECTIVE: Our retrospective monocentric observational study aimed to analyse the application ratio of combined neurohormonal antagonist therapy (RASi: ACEI/ARB/ARNI + ßB + MRA) and 12-month all-cause mortality differences in terms of renal dysfunction among HFrEF patients hospitalized for heart failure. METHOD: We retrospectively analysed the cohort of consecutive HFrEF patients, hospitalized at the Heart Failure Unit of our tertiary cardiological centre in 2019-2021. The application ratio of discharge triple therapy (TT) in five groups established on admission eGFR parameters, representing severity of renal dysfunction (eGFR≥90, eGFR = 60-89, eGFR = 45-59, eGFR = 30-44, eGFR<30 ml/min/1.73 m2) was investigated with chi-square test, while 12-month mortality differences were analysed with Kaplan-Meier method and log-rank test. RESULTS: 257 patients were included. Median eGFR was 57 (39-75) ml/min/1.73 m2, 54% of patients had eGFR<60 ml/min/1.73 m2. The proportion of patients in eGFR≥90, 60-89, 45-59, 30-44, <30 ml/min/1.73 m2 subgroups was 12%, 34%, 18%, 21%, 15%, respectively. 2% of patients were on dialysis. Even though the application rate of TT was notably high (77%) in the total cohort, more severe renal dysfunction led to a significantly lower implementation rate of TT (94%, 86%, 91%, 70%, 34%; p<0.0001): the application rate of RASi (100%, 98%, 96%, 89%, 50%, p<0.0001), ßB (94%, 88%, 96%, 79%, 68%; p = 0.003) and MRA therapy (97%, 99%, 98%, 94%, 82%; p = 0.001) differed significantly. 12-month all-cause mortality was 23% in the whole cohort. Mortality rates were higher in more severe renal dysfunction (3%, 15%, 22%, 31%, 46%; p<0.0001). CONCLUSION: Even though the proportion of patients on TT in the whole cohort was remarkably high, renal dysfunction led to a significantly lower application ratio of TT, associating with worse survival. Our results highlight that despite renal dysfunction the application of HFrEF cornerstone pharmacotherapy is essential. Orv Hetil. 2023; 164(35): 1387-1396.


Asunto(s)
Insuficiencia Cardíaca , Enfermedades Renales , Humanos , Insuficiencia Cardíaca/tratamiento farmacológico , Estudios Retrospectivos , Antagonistas de Receptores de Angiotensina/uso terapéutico , Volumen Sistólico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Riñón
8.
Trends Cardiovasc Med ; 32(2): 84-89, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33482321

RESUMEN

Cardiac implantable electronic devices establish proper therapy for the prevention of sudden cardiac death, significantly reducing the morbidity and mortality of patients with arrhythmias and heart failure. It is well-known that the number of electrodes increases the risk of complications. To preserve the benefit of atrial sensing without the need to implant an additional lead, a single-lead ICD system with a floating atrial dipole (DX ICD lead) has been developed. Besides all of the potential benefits, the necessity of a reliable and stable atrial sensing via the floating dipole could be the main concern against the use of this lead type. In the current generation of DX devices, the specially filtered atrial signal seems to be high enough and stable over time, which is crucial in the early detection of atrial arrhythmias, discrimination between different forms of tachycardias in order to prevent inappropriate ICD therapy, and achieving an optimal atrioventricular and interventricular synchrony in patients with a two-lead CRT-DX system. The present review summarizes the benefits and potential drawbacks of the DX ICD systems based on the available literature, furthermore, proposes an evidence-based algorithm of ICD type selection.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Estudios de Factibilidad , Atrios Cardíacos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos
9.
ESC Heart Fail ; 8(2): 1571-1581, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33619893

RESUMEN

AIMS: This study aims to characterize the range of implantable device-based sensor values including heart sounds, markers of ventilation, thoracic impedance, activity, and heart rate for patients with heart failure (HF) when patients were deemed to be in clinically stable periods against the time course of acute decompensation and recovery from HF events. METHODS AND RESULTS: The MultiSENSE trial followed 900 patients implanted with a COGNIS CRT-D for up to 1 year. Chronic, ambulatory diagnostic sensor data were collected and evaluated during clinically stable periods (CSP: unchanged NYHA classification, no adverse events, and weight change ≤2.27 kg), and in the timeframe leading up to and following HF events (HF admissions or unscheduled visits with intravenous HF treatment). Physiologic sensor data from 1667 CSPs occurring in 676 patients were compared with those data leading up to and following 192 HF events in 106 patients. Overall, the mean age was 66.6 years, and the population were predominantly male (73%). Patients were primarily in NYHA II (67%), with a mean LVEF of 29.6% and median NT-proBNP of 754.5 pg/mL. Sensor values during CSP were poorer in patients who had HF events during the study period than those without HF events, including first heart sound (S1: 2.18 ± 0.84 mG vs. 2.62 ± 0.95 mG, P = 0.002), third heart sound (S3: 1.13 ± 0.36 mG vs. 0.91 ± 0.30 mG, P < 0.001), thoracic impedance (45.66 ± 8.78 Ohm vs. 50.33 ± 8.43 Ohm, P < 0.001), respiratory rate (19.09 ± 3.10 br/min vs. 17.66 ± 2.39 br/min, P = 0.002), night time heart rate (73.39 ± 8.36 b.p.m. vs. 69.56 ± 8.09 b.p.m., P = 0.001), patient activity (1.69 ± 1.84 h vs. 2.56 ± 2.20 h, P = 0.006), and HeartLogic index (11.07 ± 12.14 vs. 5.31 ± 5.13, P = 0.001). Sensor parameters measured worsening status leading up to HF events with recovery of values following treatment. CONCLUSIONS: Device-based physiologic sensors not only revealed progressive worsening leading up to HF events but also differentiated patients at increased risk of HF events when presumed to be clinically stable.


Asunto(s)
Insuficiencia Cardíaca , Anciano , Insuficiencia Cardíaca/diagnóstico , Frecuencia Cardíaca , Hospitalización , Humanos , Masculino
10.
Clin Cardiol ; 43(12): 1641-1648, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33140454

RESUMEN

BACKGROUND: Recently published studies suggested that digoxin may increase mortality in heart failure with reduced ejection fraction (HFrEF). However, in the vast majority of former trials serum digoxin concentration (SDC) was not measured and therapy was not SDC-guided. AIM: To assess the impact of SDC-guided digoxin therapy on mortality in HFrEF patients. METHODS: Data of 580 HFrEF patients were retrospectively analyzed. In patients on digoxin, SDC was measured every 3 months and digoxin dosage was SDC-guided (target SDC: 0.5-0.9 ng/mL). All-cause mortality of digoxin users and nonusers was compared after propensity score matching (PSM). RESULTS: After 7.1 ± 4.7 years follow-up period (FUP) all-cause mortality of digoxin users (n = 180) was significantly higher than nonusers (n = 297) (propensity-adjusted HR = 1.430; 95% CI = 1.134-1.804; P = .003). Patients having SDC of 0.9 to 1.1 ng/mL (n = 60) or > 1.1 ng/mL (n = 44) at any time during the FUP had an increased risk of all-cause mortality (HR = 1.750; 95% CI = 1.257-2.436, P = .001 and HR = 1.687; 95% CI = 1.153-2.466, P = .007), while patients having a maximal SDC < 0.9 ng/mL (n = 76) had similar mortality risk (HR = 1.139; 95% CI = 0.827-1.570, P = .426), compared to digoxin nonusers. CONCLUSIONS: According to our propensity-matched analysis, SDC-guided digoxin therapy was associated with increased all-cause mortality in optimally treated HFrEF patients, especially with SDC ≥0.9 ng/mL. These results reinforce the expert opinion that digoxin in HFrEF can only be used among carefully selected patients with close SDC monitoring.


Asunto(s)
Digoxina/farmacocinética , Insuficiencia Cardíaca/tratamiento farmacológico , Puntaje de Propensión , Volumen Sistólico/fisiología , Cardiotónicos/farmacocinética , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/sangre , Insuficiencia Cardíaca/mortalidad , Humanos , Hungría/epidemiología , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
11.
J Interv Card Electrophysiol ; 57(2): 295-301, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31342222

RESUMEN

PURPOSE: Pneumothorax (PTX) following cardiac implantable electronic device procedures is traditionally treated with chest tube drainage (CTD). We hypothesized that, in a subset of patients, the less invasive needle aspiration (NA) may also be effective. We compared the strategy of primary NA with that of primary CTD in a single-center observational study. METHODS: Of the 970 procedures with subclavian venous access between January 2016 and June 2018, 23 patients had PTX requiring intervention. Beginning with March 2017, the traditional primary CTD (9 cases) has been replaced by the "NA first" strategy (14 patients). Outcome measures were procedural success rate and duration of hospitalization evaluated both as time to event (log-rank test) and as a discrete variable (Wilcoxon-Mann-Whitney test). RESULTS: Needle aspiration was successful in 8/14 (57.1%) of the cases (95% CI 28.9-82.3%), whereas PTX resolved in all patients after CTD was 9/9 (100%, 95% CI 66.4-100.0%, p = 0.0481). Regarding length of hospital stay, intention to treat time to event analysis showed no difference between the two approaches (p = 0.73). Also, the median difference was not statistically significant (- 2.0 days, p = 0.17). In contrast, per protocol evaluation revealed reduced risk of prolonged hospitalization for NA patients (p = 0.0025) with a median difference of - 4.0 days (p = 0.0012). Failure of NA did not result in a meaningful delay in discharge timing as median difference was 1.5 days (p = 0.28). CONCLUSIONS: Our data suggest that in a number of patients iatrogenic PTX may be successfully treated with NA resulting in shorter hospitalization without the risk of meaningful discharge delay in unsuccessful cases.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Neumotórax/etiología , Neumotórax/terapia , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Succión/instrumentación , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Enfermedad Iatrogénica , Masculino , Agujas , Proyectos Piloto , Sistema de Registros
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA