Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Phys Rev Lett ; 114(24): 245001, 2015 Jun 19.
Artículo en Inglés | MEDLINE | ID: mdl-26196980

RESUMEN

Edge intrinsic rotation was investigated in Ohmic L-mode discharges on the Tokamak à Configuration Variable, scanning the major radial position of the X point, R(X). Edge rotation decreased linearly with increasing R(X), vanishing or becoming countercurrent for an outboard X point, in agreement with theoretical expectations. The core rotation profile shifted fairly rigidly with the edge rotation, changing the central rotation speed by more than a factor of two. Core rotation reversals had little effect on the edge rotation velocity. Edge rotation was modestly more countercurrent in unfavorable than favorable ∇B shots.

2.
Rev Sci Instrum ; 93(11): 113513, 2022 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-36461455

RESUMEN

Measurements of radiated power are critical for characterizing and optimizing tokamak performance. The RADCAM system, comprising arrays of foil bolometers, Absolute eXtreme UltraViolet (AXUV), and filtered soft x-ray diodes, has been constructed to provide improved measurements of plasma radiation on "Tokamak a Configuration Variable" (TCV). An overview of the physical geometry, electronics, and design of the system is provided. The construction of the bolometer foils together with the improved sensitivity characteristics resulting from the inclusion of an anti-reflection carbon coating are presented. The large number of lines of sight in RADCAM are shown to significantly increase the spatial resolution over the legacy system. The system calibration procedure is detailed, and the mean system sensitivity is shown to vary by less than 5% over 1000 discharges. Additionally, the methodology for cross-calibration of the AXUV diodes with the bolometer foils is presented and applied to generate high temporal resolution measurements. The RADCAM radiation camera system is a compact, versatile system that is demonstrated to provide high resolution profiles of the radiated power in TCV.

3.
Rev Sci Instrum ; 93(12): 123504, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36586925

RESUMEN

We present the design and operation of a suite of Gas Puff Imaging (GPI) diagnostic systems installed on the Tokamak à Configuration Variable (TCV) for the study of turbulence in the plasma edge and Scrape-Off-Layer (SOL). These systems provide the unique ability to simultaneously collect poloidal 2D images of plasma dynamics at the outboard midplane, around the X-point, in both the High-Field Side (HFS) and Low-Field Side (LFS) SOL, and in the divertor region. We describe and characterize an innovative control system for deuterium and helium gas injection, which is becoming the default standard for the other gas injections at TCV. Extensive pre-design studies and the different detection systems are presented, including an array of avalanche photodiodes and a high-speed CMOS camera. First results with spatial and time resolutions of up to ≈2 mm and 0.5 µs, respectively, are described, and future upgrades of the GPI diagnostics for TCV are discussed.

4.
Rev Sci Instrum ; 93(12): 123505, 2022 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-36586937

RESUMEN

High resolution spectroscopy on the Tokamak à Configuration Variable (TCV) divertor plasma provided Doppler broadening measurements to infer the ion and neutral temperature of injected helium gas. This paper presents the Divertor Spectroscopy System's (DSS) access to He II ion temperature measurements over a broad range, ≈0.5-15 eV, with an uncertainty of <10% for most of the studied plasma discharges. TCV's shaping flexibility was employed to validate these measurements against Thomson scattering across the DSS lines of sight. In detachment-related experiments, Ti(He II) ≃ Te, making this diagnostic a reliable thermometer along the divertor leg plasma over the wide range of magnetic equilibria and divertor configurations achievable in TCV. A detailed description of the diagnostic hardware, data analysis, and sources of uncertainty is presented.

5.
Phys Rev Lett ; 107(26): 265001, 2011 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-22243160

RESUMEN

Direction reversals of intrinsic toroidal rotation have been observed in diverted Alcator C-Mod Ohmic L-mode plasmas following electron density ramps. For low density discharges, the core rotation is directed cocurrent, and reverses to countercurrent following an increase in the density above a certain threshold. Such reversals occur together with a decrease in density fluctuations with 2 cm(-1)≤k(θ)≤11 cm(-1) and frequencies above 70 kHz. There is a strong correlation between the reversal density and the density at which the Ohmic L-mode energy confinement changes from the linear to the saturated regime.

6.
Rev Sci Instrum ; 92(6): 063510, 2021 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-34243542

RESUMEN

Divertor detachment and alternative divertor magnetic geometries are predicted to be promising approaches to handle the power exhaust of future fusion devices. In order to understand the detachment process caused by volumetric losses in alternative divertor magnetic geometries, a Multi-Wavelength Imaging (MWI) diagnostic has recently been designed and built for the Mega Amp Spherical Tokamak Upgrade. The MWI diagnostic will simultaneously capture 11 spectrally filtered images of the visible light emitted from divertor plasmas and provide crucial knowledge for the interpretation of observations and modeling efforts. This paper presents the optical design, mechanical design, hardware, and test results of an 11-channel MWI system with a field of view of 40°. The optical design shows better than 5 mm FWHM spatial resolution at the plasma on all 11 channels across the whole field of view. The spread of angle of incidence on the surface of each filter is also analyzed to inform the bandwidth specification of the interference filters. The results of the initial laboratory tests demonstrate that a spatial resolution of better than 5 mm FWHM is achieved for all 11 channels, meeting the specifications required for accurate tomography.

7.
Nat Commun ; 12(1): 1105, 2021 Feb 17.
Artículo en Inglés | MEDLINE | ID: mdl-33597525

RESUMEN

In magnetic confinement thermonuclear fusion the exhaust of heat and particles from the core remains a major challenge. Heat and particles leaving the core are transported via open magnetic field lines to a region of the reactor wall, called the divertor. Unabated, the heat and particle fluxes may become intolerable and damage the divertor. Controlled 'plasma detachment', a regime characterized by both a large reduction in plasma pressure and temperature at the divertor target, is required to reduce fluxes onto the divertor. Here we report a systematic approach towards achieving this critical need through feedback control of impurity emission front locations and its experimental demonstration. Our approach comprises a combination of real-time plasma diagnostic utilization, dynamic characterization of the plasma in proximity to the divertor, and efficient, reliable offline feedback controller design.

8.
Phys Rev Lett ; 105(15): 155003, 2010 Oct 08.
Artículo en Inglés | MEDLINE | ID: mdl-21230915

RESUMEN

An edge-localized mode (ELM) H-mode regime, supported by electron cyclotron heating, has been successfully established in a "snowflake" (second-order null) divertor configuration for the first time in the TCV tokamak. This regime exhibits 2 to 3 times lower ELM frequency and 20%-30% increased normalized ELM energy (ΔWELM/Wp) compared to an identically shaped, conventional single-null diverted H mode. Enhanced stability of mid- to high-toroidal-mode-number ideal modes is consistent with the different snowflake ELM phenomenology. The capability of the snowflake to redistribute the edge power on the additional strike points has been confirmed experimentally.

9.
Phys Rev Lett ; 105(13): 135003, 2010 Sep 24.
Artículo en Inglés | MEDLINE | ID: mdl-21230780

RESUMEN

The first experimental evidence of parallel momentum transport generated by the up-down asymmetry of a toroidal plasma is reported. The experiments, conducted in the Tokamak à Configuration Variable, were motivated by the recent theoretical discovery of ion-scale turbulent momentum transport induced by an up-down asymmetry in the magnetic equilibrium. The toroidal rotation gradient is observed to depend on the asymmetry in the outer part of the plasma leading to a variation of the central rotation by a factor of 1.5-2. The direction of the effect and its magnitude are in agreement with theoretical predictions for the eight possible combinations of plasma asymmetry, current, and magnetic field.

10.
Rev Sci Instrum ; 90(12): 123514, 2019 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-31893833

RESUMEN

This work presents a novel, real-time capable, 10-channel Multispectral Advanced Narrowband Tokamak Imaging System installed on the TCV tokamak, MANTIS. Software and hardware requirements are presented together with the complete system architecture. The image quality of the system is assessed with emphasis on effects resulting from the narrowband interference filters. Some filters are found to create internal reflection images that are correlated with the filters' reflection coefficient. This was measured for selected filters where significant absorption (up to 65% within ∼70 nm of the filter center) was measured. The majority of this was attributed to the filter's design, and several filters' performance is compared. Tailored real-time algorithms exploiting the system's capabilities are presented together with benchmarks comparing polling and event based synchronization. The real-time performance is demonstrated with a density ramp discharge performed on TCV. The behavior of spectral lines' emission from different plasma species and their interpretation are qualitatively described.

11.
Rev Sci Instrum ; 89(10): 103503, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30399774

RESUMEN

The Multi-Spectral Imaging system is a new diagnostic that captures simultaneous spectrally filtered images from a common line of sight while maintaining a large étendue and high throughput. Imaging several atomic line intensities simultaneously may enable numerous measurement techniques. By making a novel modification of a polychromator layout, the MSI sequentially filters and focuses images onto commercial CMOS cameras while exhibiting minimal vignetting and aberrations. A four-wavelength system was initially installed and tested on Alcator C-Mod and subsequently moved to TCV. The images are absolutely calibrated and spatially registered enabling 2D mappings of atomic line ratios and absolute line intensities. The spectral transmission of the optical system was calibrated using an integrating sphere of known radiance. The images are inverted by cross-referencing points on TCV with a computer-aided design (CAD) model.


Asunto(s)
Diagnóstico por Imagen/instrumentación , Calibración , Análisis Espectral
12.
Rev Sci Instrum ; 78(8): 086108, 2007 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-17764368

RESUMEN

A single chord, single processing chain, hybrid (analog/digital) pulse height analysis diagnostic has been developed for the TCV tokamak, aiming to provide the evolution of the plasma electron temperature with a software selectable minimum temporal resolution of 100 ms. The high count rate (approximately 65 kHz) together with an energy resolution of 190 eV (at 5.9 keV) were achieved by encoding the data stream with an on-site developed interface amplifier and time generator. The diagnostic was also used to investigate the non-Maxwellian behavior of the electron energy distribution function with strong electron cyclotron resonance heating and to monitor the presence of intrinsic and injected impurities in the 700 eV-20 keV energy range. The conversion of this diagnostic into a real-time control tool is under development.


Asunto(s)
Algoritmos , Aceleradores de Partículas/instrumentación , Procesamiento de Señales Asistido por Computador , Difracción de Rayos X/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Factores de Tiempo
13.
Rev Sci Instrum ; 87(11): 11D431, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27910401

RESUMEN

Naked foil bolometers can reflect a significant fraction of incident energy and therefore cannot be used for absolute measurements. This paper outlines a novel coating approach to address this problem by blackening the surface of gold foil bolometers using physical vapour deposition. An experimental bolometer was built containing four standard gold foil bolometers, of which two were coated with 100+ nm of carbon. All bolometers were collimated and observed the same relatively high temperature, ohmically heated plasma. Preliminary results showed 13%-15% more incident power was measured by the coated bolometers and this is expected to be much higher in future TCV detached divertor experiments.

14.
Phys Rev Lett ; 97(23): 235003, 2006 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-17280210

RESUMEN

Bulk plasma toroidal rotation is observed to invert spontaneously from counter to cocurrent direction in TCV (Tokamak à Configuration Variable) Ohmically heated discharges, in low confinement mode, without momentum input. The inversion occurs in high current discharges, when the plasma electron density exceeds a well-defined threshold. The transition between the two rotational regimes has been studied by means of density ramps. The results provide evidence of a change of the balance of nondiffusive momentum fluxes in the core of a plasma without an external drive.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA