Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Crit Care ; 27(1): 262, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37403149

RESUMEN

BACKGROUND: Several noninvasive ventilatory supports rely in their design on high oxygen consumption which may precipitate oxygen shortage, as experienced during the COVID-19 pandemic. In this bench-to-bedside study, we assessed the performance of a new continuous positive airway pressure (CPAP) device integrating a large reservoir ("Bag-CPAP") designed to minimize oxygen consumption, and compared it with other CPAP devices. METHODS: First, a bench study compared the performances of Bag-CPAP and four CPAP devices with an intensive care unit ventilator. Two FiO2 targets (40-60% and 80-100%) at a predefined positive end expiratory pressure (PEEP) level between 5 and 10 cm H2O were tested and fraction of inspired oxygen (FiO2) and oxygen consumption were measured. Device-imposed work of breathing (WOB) was also evaluated. Second, an observational clinical study evaluated the new CPAP in 20 adult patients with acute respiratory failure in two hospitals in France. Actual FiO2, PEEP, peripheral oxygen saturation, respiratory rate, and dyspnea score were assessed. RESULTS: All six systems tested in the bench study reached the minimal FiO2 target of 40% and four reached at least 80% FiO2 while maintaining PEEP in the predefined range. Device-delivered FiO2/consumed oxygen ratio was the highest with the new reservoir-based CPAP irrespective of FiO2 target. WOB induced by the device was higher with Bag-CPAP. In the clinical study, Bag-CPAP was well tolerated and could reach high (> 90%) and moderate (> 50%) FiO2 with an oxygen flow rate of 15 [15-16] and 8 [7-9] L/min, respectively. Dyspnea score improved significantly after introduction of Bag-CPAP, and SpO2 increased. CONCLUSIONS: In vitro, Bag-CPAP exhibited the highest oxygen saving properties albeit had increased WOB. It was well accepted clinically and reduced dyspnea. Bag-CPAP may be useful to treat patients with acute respiratory failure in the field, especially when facing constraints in oxygen delivery.


Asunto(s)
COVID-19 , Insuficiencia Respiratoria , Adulto , Humanos , Presión de las Vías Aéreas Positiva Contínua , COVID-19/terapia , Disnea , Oxígeno , Consumo de Oxígeno , Pandemias , Insuficiencia Respiratoria/terapia
2.
Diagnostics (Basel) ; 13(7)2023 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-37046544

RESUMEN

The diagnosis of PE remains difficult in 2023 because the signs and symptoms are not sensible nor specific. The consequences of potential diagnostic errors can be dramatic, whether by default or by excess. Furthermore, the achievement of a simple diagnostic strategy, based on clinical probability assessment, D-dimer measurement and computed tomography pulmonary angiography (CTPA) leads to a new challenge for PE diagnosis: over-testing. Indeed, since the 2000s, the wide availability of CTPA resulted in a major increase in investigations with a mod I confirm erate increase in PE diagnosis, without any notable improvement in patient outcomes. Quite the contrary, the complications of anticoagulation for PE increased significantly, and the long-term consequences of imaging diagnostic radiation is an important concern, especially the risk of breast cancer for young women. As a result, several strategies have been proposed to fight over-testing. They are mostly based on defining a subgroup of patients for whom no specific exam should be required to rule-out PE and adjusting the D-dimer cutoff to allow the exclusion of PE without performing CTPA. This narrative review presents the advantages and limitations of these different strategies as well as the perspective in PE diagnosis.

3.
J Cardiovasc Dev Dis ; 2(3): 233-247, 2015 Sep 08.
Artículo en Inglés | MEDLINE | ID: mdl-26594644

RESUMEN

Although the genetic basis of mitral valve prolapse (MVP) has now been clearly established, the molecular and cellular mechanisms involved in the pathological processes associated to a specific mutation often remain to be determined. The FLNA gene (encoding Filamin A; FlnA) was the first gene associated to non-syndromic X-linked myxomatous valvular dystrophy, but the impacts of the mutations on its function remain un-elucidated. Here, using the first repeats (1-8) of FlnA as a bait in a yeast two-hybrid screen, we identified the tyrosine phosphatase PTPN12 (PTP-PEST) as a specific binding partner of this region of FlnA protein. In addition, using yeast two-hybrid trap assay pull down and co-immunoprecipitation experiments, we showed that the MVP-associated FlnA mutations (G288R, P637Q, H743P) abolished FlnA/PTPN12 interactions. PTPN12 is a key regulator of signaling pathways involved in cell-extracellular matrix (ECM) crosstalk, cellular responses to mechanical stress that involve integrins, focal adhesion transduction pathways, and actin cytoskeleton dynamics. Interestingly, we showed that the FlnA mutations impair the activation status of two PTPN12 substrates, the focal adhesion associated kinase Src, and the RhoA specific activating protein p190RhoGAP. Together, these data point to PTPN12/FlnA interaction and its weakening by FlnA mutations as a mechanism potentially involved in the physiopathology of FlnA-associated MVP.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA