Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Proc Inst Mech Eng H ; 224(2): 291-306, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20349820

RESUMEN

Recently there have been significant advances in developing hybrid techniques combining electromagnetic waves with ultrasound for biomedical imaging, namely photoacoustic, thermoacoustic, and acousto-optic (or ultrasound modulated optical) tomography. All three techniques take advantage of tissue contrast offered by electromagnetic (EM) waves, while achieving good spatial resolution in deeper tissue facilitated by ultrasound. In this review the principles of the three techniques are introduced. A description of existing experimental and image reconstruction techniques is provided. Some recent key developments are highlighted and current issues in each of the areas are discussed.


Asunto(s)
Diagnóstico por Imagen de Elasticidad/instrumentación , Diagnóstico por Imagen de Elasticidad/métodos , Interpretación de Imagen Asistida por Computador/instrumentación , Microscopía Acústica/instrumentación , Microscopía Acústica/métodos , Termografía/instrumentación , Termografía/métodos , Diseño de Equipo , Aumento de la Imagen/instrumentación , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos
2.
Br J Dermatol ; 159(1): 152-61, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18460029

RESUMEN

BACKGROUND: Fluorescence lifetime imaging (FLIM) is a novel imaging technique that generates image contrast between different states of tissue due to differences in fluorescence decay rates. OBJECTIVES: To establish whether FLIM of skin autofluorescence can provide useful contrast between basal cell carcinomas (BCCs) and surrounding uninvolved skin. METHODS: Unstained excision biopsies of 25 BCCs were imaged en face with FLIM following excitation of autofluorescence with a 355 nm pulsed ultraviolet laser. RESULTS: Using FLIM we were able to distinguish areas of BCC from surrounding skin in an ex vivo study. Significant reductions in mean fluorescence lifetimes between areas of BCC and areas of surrounding uninvolved skin were demonstrated (P < 0.0001). These differences were apparent irrespective of the decay model used to calculate the fluorescence lifetimes (single vs. stretched exponential) or the long-pass filter through which the emitted autofluorescence was collected (375 vs. 455 nm). Conversely, there was no significant difference between the BCC and uninvolved areas of each sample when mean autofluorescence intensities were examined. Moreover, wide-field false-colour images of fluorescence lifetimes clearly discriminated areas of BCC from the surrounding uninvolved skin. CONCLUSIONS: We therefore believe that FLIM has a potential future clinical role in imaging BCCs for rapid and noninvasive tumour delineation and as an aid to determine adequate excision margins with best preservation of normal tissue.


Asunto(s)
Carcinoma Basocelular/diagnóstico , Diagnóstico por Imagen/métodos , Neoplasias Cutáneas/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Fluorescencia , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias/métodos , Sensibilidad y Especificidad
3.
Opt Express ; 15(18): 11196-206, 2007 Sep 03.
Artículo en Inglés | MEDLINE | ID: mdl-19547474

RESUMEN

We describe an optical sectioning microscopy system with no moving parts based on a micro-structured stripe-array light emitting diode (LED). By projecting arbitrary line or grid patterns onto the object, we are able to implement a variety of optical sectioning microscopy techniques such as grid-projection structured illumination and line scanning confocal microscopy, switching from one imaging technique to another without modifying the microscope setup. The micro-structured LED and driver are detailed and depth discrimination capabilities are measured and calculated.

4.
New J Phys ; 9: 127, 2007.
Artículo en Inglés | MEDLINE | ID: mdl-19503759

RESUMEN

We report a side viewing fibre-based endoscope that is compatible with intravascular imaging and fluorescence lifetime imaging microscopy (FLIM). The instrument has been validated through testing with fluorescent dyes and collagen and elastin powders using the Laguerre expansion deconvolution technique to calculate the fluorescence lifetimes. The instrument has also been tested on freshly excised unstained animal vascular tissues.

6.
IEEE Trans Med Imaging ; 33(10): 1913-30, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24876109

RESUMEN

Intra-operative imaging techniques for obtaining the shape and morphology of soft-tissue surfaces in vivo are a key enabling technology for advanced surgical systems. Different optical techniques for 3-D surface reconstruction in laparoscopy have been proposed, however, so far no quantitative and comparative validation has been performed. Furthermore, robustness of the methods to clinically important factors like smoke or bleeding has not yet been assessed. To address these issues, we have formed a joint international initiative with the aim of validating different state-of-the-art passive and active reconstruction methods in a comparative manner. In this comprehensive in vitro study, we investigated reconstruction accuracy using different organs with various shape and texture and also tested reconstruction robustness with respect to a number of factors like the pose of the endoscope as well as the amount of blood or smoke present in the scene. The study suggests complementary advantages of the different techniques with respect to accuracy, robustness, point density, hardware complexity and computation time. While reconstruction accuracy under ideal conditions was generally high, robustness is a remaining issue to be addressed. Future work should include sensor fusion and in vivo validation studies in a specific clinical context. To trigger further research in surface reconstruction, stereoscopic data of the study will be made publically available at www.open-CAS.com upon publication of the paper.


Asunto(s)
Imagenología Tridimensional/métodos , Laparoscopía/métodos , Cirugía Asistida por Computador/métodos , Animales , Endoscopios , Riñón/anatomía & histología , Riñón/cirugía , Hígado/anatomía & histología , Hígado/cirugía , Modelos Biológicos , Reproducibilidad de los Resultados , Porcinos
7.
Opt Lett ; 30(24): 3353-5, 2005 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-16389829

RESUMEN

We demonstrate an optically sectioned fluorescence lifetime imaging microscope with a wide-field detector, using a convenient, continuously tunable (435-1150 nm) ultrafast source for fluorescence imaging applications that is derived from a visible supercontinuum generated in a microstructured fiber.

8.
Opt Lett ; 27(16): 1409-11, 2002 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-18026462

RESUMEN

We report a wide-field fluorescence lifetime imaging (FLIM) system that uses a blue picosecond pulsed diode laser as the excitation source. This represents a significant miniaturization and simplification compared with other time-domain FLIM instruments that should accelerate the development of clinical and real-world applications of FLIM. We have demonstrated this instrument in two configurations: a macroimaging setup applied to multiwell plate assays of chemically and biologically interesting fluorophores and a microscope system that has been applied to imaging of tissue sections. The importance of the adjustable repetition rate of this laser source is discussed with respect to noise reduction and precision in the lifetime determination, illustrating a further significant advantage over conventional mode-locked solid-state lasers.

9.
Opt Lett ; 26(17): 1338-40, 2001 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-18049601

RESUMEN

We report a novel whole-field three-dimensional fluorescence lifetime imaging microscope that incoporates multispectral imaging to provide five-dimensional (5-D) fluorescence microscopy. This instrument, which can acquire a 5-D data set in less than a minute, is based on potentially compact and inexpensive diode-pumped solid-state laser technology. We demonstrate that spectral discrimination as well as optical sectioning minimize artifacts in lifetime determination and illustrate how spectral discrimination improves the lifetime contrast of biological tissue.

10.
Opt Lett ; 29(19): 2249-51, 2004 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-15524370

RESUMEN

We report the development of a high-speed wide-field fluorescence-lifetime imaging (FLIM) system that provides fluorescence-lifetime images at rates of as many as 29 frames/s. A FLIM multiwell plate reader and a potentially portable FLIM endoscopic system operating at 355-nm excitation have been demonstrated.


Asunto(s)
Algoritmos , Endoscopios , Interpretación de Imagen Asistida por Computador/métodos , Microscopía Fluorescente/métodos , Sistemas en Línea/instrumentación , Espectrometría de Fluorescencia/métodos , Grabación en Video/instrumentación , Endoscopía/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Estudios de Factibilidad , Grabación en Video/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA