Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Acta Radiol ; 65(7): 716-723, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38872362

RESUMEN

BACKGROUND: With rising breast augmentations worldwide, there is an increasing clinical need for an early and accurate detection of implant complications. PURPOSE: To compare the quality of chemical shift encoding-based (CSE) water-fat-silicone separation compared to double inversion recovery (DIR) silicone-only imaging in breast magnetic resonance imaging (MRI). MATERIAL AND METHODS: This retrospective, single-center study included women with silicone implants subjected to 3-T MRI between January 2021 and March 2022. MRI included (i) two-dimensional silicone-only T2-weighted turbo spin echo DIR acquisition and (ii) three-dimensional CSE imaging based on multi-echo gradient-echo sequence enabling water-, fat-, and silicone-image separation. Images were evaluated and compared by three independent radiologists using a clinically established rating including differentiability of the silicone implant, visibility and contouring of the adjacent fibrous capsule, and accuracy of intralesional folds in a ranking of 1-5. The apparent contrast-to-noise (aCNR) was calculated. RESULTS: In 71 women, the average quality of water-fat-silicone images from CSE imaging was assessed as "good" (assessment 4 ± 0.9). In 68 (96%) patients, CSE imaging achieved a concise delineation of the silicone implant and precise visualization of the fibrous capsule that was not distinguishable in DIR imaging. Implant ruptures were more easily detected in CSE imaging. The aCNR was higher in CSE compared to DIR imaging (18.43 ± 9.8 vs. 14.73 ± 2.5; P = 0.002). CONCLUSION: Intrinsically co-registered water-fat-silicone-separated CSE-based images enable a reliable assessment of silicone implants. The simultaneously improved differentiability of the implant and fibrous capsule may provide clinicians with a valuable tool for an accurate evaluation of implant integrity and early detection of potential complications.


Asunto(s)
Implantes de Mama , Imagen por Resonancia Magnética , Siliconas , Humanos , Femenino , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Adulto , Persona de Mediana Edad , Mama/diagnóstico por imagen , Agua , Tejido Adiposo/diagnóstico por imagen , Geles de Silicona , Anciano
3.
Int J Radiat Oncol Biol Phys ; 119(5): 1455-1463, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38458496

RESUMEN

PURPOSE: The identification of internal mammary lymph node metastases and the assessment of associated risk factors are crucial for adjuvant regional lymph node irradiation in patients with breast cancer. The current study aims to investigate whether tumor contact with internal mammary perforator vessels is associated with gross internal mammary lymph node involvement. METHODS AND MATERIALS: We included 297 patients with primary breast cancer and gross internal mammary (IMN+) and/or axillary metastases as well as 230 patients without lymph node metastases. Based on pretreatment dynamic contrast-enhanced magnetic resonance imaging, we assessed contact of the tumor with the internal mammary perforating vessels (IMPV). RESULTS: A total of 59 patients had ipsilateral IMN+ (iIMN+), 10 patients had contralateral IMN+ (cIMN+), and 228 patients had ipsilateral axillary metastases without IMN; 230 patients had node-negative breast cancer. In patients with iIMN+, 100% of tumors had contact with ipsilateral IMPV, with 94.9% (n = 56) classified as major contact. In iIMN- patients, major IMPV contact was observed in only 25.3% (n = 116), and 36.2% (n = 166) had no IMPV contact at all. Receiver operating characteristic analysis revealed that "major IMPV contact" was more accurate in predicting iIMN+ (area under the curve, 0.85) compared with a multivariate model combining grade of differentiation, tumor site, size, and molecular subtype (area under the curve, 0.65). Strikingly, among patients with cIMN+, 100% of tumors had contact with a crossing contralateral IMPV, whereas in cIMN- patients, IMPVs to the contralateral side were observed in only 53.4% (iIMN+) and 24.8% (iIMN-), respectively. CONCLUSIONS: Tumor contact with the IMPV is highly associated with risk of gross IMN involvement. Further studies are warranted to investigate whether this identified risk factor is also associated with microscopic IMN involvement and whether it can assist in the selection of patients with breast cancer for irradiation of the internal mammary lymph nodes.


Asunto(s)
Axila , Neoplasias de la Mama , Ganglios Linfáticos , Metástasis Linfática , Imagen por Resonancia Magnética , Humanos , Femenino , Persona de Mediana Edad , Neoplasias de la Mama/patología , Neoplasias de la Mama/radioterapia , Factores de Riesgo , Anciano , Adulto , Ganglios Linfáticos/patología , Ganglios Linfáticos/diagnóstico por imagen , Anciano de 80 o más Años , Arterias Mamarias/diagnóstico por imagen
4.
Breast Care (Basel) ; 19(3): 165-182, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38894952

RESUMEN

Introduction: Each year the interdisciplinary AGO (Arbeitsgemeinschaft Gynäkologische Onkologie, German Gynecological Oncology Group) Breast Committee on Diagnosis and Treatment of Breast Cancer provides updated state-of-the-art recommendations for early and metastatic breast cancer. Methods: The updated evidence-based treatment recommendations for early and metastatic breast cancer have been released in March 2024. Results and Conclusion: This paper concisely captures the updated recommendations for early breast cancer chapter by chapter.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA