Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Ear Hear ; 42(4): 941-948, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33369942

RESUMEN

OBJECTIVES: Electrocochleography (ECochG), obtained before the insertion of a cochlear implant (CI) array, provides a measure of residual cochlear function that accounts for a substantial portion of variability in postoperative speech perception outcomes in adults. It is postulated that subsequent surgical factors represent independent sources of variance in outcomes. Prior work has demonstrated a positive correlation between angular insertion depth (AID) of straight arrays and speech perception under the CI-alone condition, with an inverse relationship observed for precurved arrays. The purpose of the present study was to determine the combined effects of ECochG, AID, and array design on speech perception outcomes. DESIGN: Participants were 50 postlingually deafened adult CI recipients who received one of three straight arrays (MED-EL Flex24, MED-EL Flex28, and MED-EL Standard) and two precurved arrays (Cochlear Contour Advance and Advanced Bionics HiFocus Mid-Scala). Residual cochlear function was determined by the intraoperative ECochG total response (TR) measured before array insertion, which is the sum of magnitudes of spectral components in response to tones of different stimulus frequencies across the speech spectrum. The AID was then determined with postoperative imaging. Multiple linear regression was used to predict consonant-nucleus-consonant (CNC) word recognition in the CI-alone condition at 6 months postactivation based on AID, TR, and array design. RESULTS: Forty-one participants received a straight array and nine received a precurved array. The AID of the most apical electrode contact ranged from 341° to 696°. The TR measured by ECochG accounted for 43% of variance in speech perception outcomes (p < 0.001). A regression model predicting CNC word scores with the TR tended to underestimate the performance for precurved arrays and deeply inserted straight arrays, and to overestimate the performance for straight arrays with shallower insertions. When combined in a multivariate linear regression, the TR, AID, and array design accounted for 72% of variability in speech perception outcomes (p < 0.001). CONCLUSIONS: A model of speech perception outcomes that incorporates TR, AID, and array design represents an improvement over a model based on TR alone. The success of this model shows that peripheral factors including cochlear health and electrode placement may play a predominant role in speech perception with CIs.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Audiometría de Respuesta Evocada , Cóclea/cirugía , Humanos
2.
J Neurophysiol ; 121(6): 2163-2180, 2019 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-30943095

RESUMEN

The cochlear summating potential (SP) to a tone is a baseline shift that persists for the duration of the burst. It is often considered the most enigmatic of cochlear potentials because its magnitude and polarity vary across frequency and level and its origins are uncertain. In this study, we used pharmacology to isolate sources of the SP originating from the gerbil cochlea. Animals either had the full complement of outer and inner hair cells (OHCs and IHCs) and an intact auditory nerve or had systemic treatment with furosemide and kanamycin (FK) to remove the outer hair cells. Responses to tone bursts were recorded from the round window before and after the neurotoxin kainic acid (KA) was applied. IHC responses were then isolated from the post-KA responses in FK animals, neural responses were isolated from the subtraction of post-KA from pre-KA responses in NH animals, and OHC responses were isolated by subtraction of post-KA responses in FK animals from post-KA responses in normal hearing (NH) animals. All three sources contributed to the SP; OHCs with a negative polarity and IHCs and the auditory nerve with positive polarity. Thus the recorded SP in NH animals is a sum of contributions from different sources, contributing to the variety of magnitudes and polarities seen across frequency and intensity. When this information was applied to observations of the SP recorded from the round window in human cochlear implant subjects, a strong neural contribution to the SP was confirmed in humans as well as gerbils. NEW & NOTEWORTHY Of the various potentials produced by the cochlea, the summating potential (SP) is typically described as the most enigmatic. Using combinations of ototoxins and neurotoxins, we show contributions to the SP from the auditory nerve and from inner and outer hair cells, which differ in polarity and vary in size across frequency and level. This complexity of sources helps to explain the enigmatic nature of the SP.


Asunto(s)
Cóclea/fisiología , Nervio Coclear/fisiología , Potenciales Evocados Auditivos/fisiología , Células Ciliadas Auditivas Internas/fisiología , Células Ciliadas Auditivas Externas/fisiología , Adulto , Animales , Implantes Cocleares , Gerbillinae , Humanos
3.
Ear Hear ; 40(4): 833-848, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30335669

RESUMEN

OBJECTIVES: Electrocochleography (ECochG) obtained through a cochlear implant (CI) is increasingly being tested as an intraoperative monitor during implantation with the goal of reducing surgical trauma. Reducing trauma should aid in preserving residual hearing and improve speech perception overall. The purpose of this study was to characterize intracochlear ECochG responses throughout insertion in a range of array types and, when applicable, relate these measures to hearing preservation. The ECochG signal in cochlear implant subjects is complex, consisting of hair cell and neural generators with differing distributions depending on the etiology and history of hearing loss. Consequently, a focus was to observe and characterize response changes as an electrode advances. DESIGN: In 36 human subjects, responses to 90 dB nHL tone bursts were recorded both at the round window (RW) and then through the apical contact of the CI as the array advanced into the cochlea. The specific setup used a sterile clip in the surgical field, attached to the ground of the implant with a software-controlled short to the apical contact. The end of the clip was then connected to standard audiometric recording equipment. The stimuli were 500 Hz tone bursts at 90 dB nHL. Audiometry for cases with intended hearing preservation (12/36 subjects) was correlated with intraoperative recordings. RESULTS: Successful intracochlear recordings were obtained in 28 subjects. For the eight unsuccessful cases, the clip introduced excessive line noise, which saturated the amplifier. Among the successful subjects, the initial intracochlear response was a median 5.8 dB larger than the response at the RW. Throughout insertion, modiolar arrays showed median response drops after stylet removal while in lateral wall arrays the maximal median response magnitude was typically at the deepest insertion depth. Four main patterns of response magnitude were seen: increases > 5 dB (12/28), steady responses within 5 dB (4/28), drops > 5 dB (from the initial response) at shallow insertion depths (< 15 mm deep, 7/28), or drops > 5 dB occurring at deeper depths (5/28). Hearing preservation, defined as < 80 dB threshold at 250 Hz, was successful in 9/12 subjects. In these subjects, an intracochlear loss of response magnitude afforded a prediction model with poor sensitivity and specificity, which improved when phase, latency, and proportion of neural components was considered. The change in hearing thresholds across cases was significantly correlated with various measures of the absolute magnitudes of response, including RW response, starting response, maximal response, and final responses (p's < 0.05, minimum of 0.0001 for the maximal response, r's > 0.57, maximum of 0.80 for the maximal response). CONCLUSIONS: Monitoring the cochlea with intracochlear ECochG during cochlear implantation is feasible, and patterns of response vary by device type. Changes in magnitude alone did not account for hearing preservation rates, but considerations of phase, latency, and neural contribution can help to interpret the changes seen and improve sensitivity and specificity. The correlation between the absolute magnitude obtained either before or during insertion of the ECochG and the hearing threshold changes suggest that cochlear health, which varies by subject, plays an important role.


Asunto(s)
Audiometría de Respuesta Evocada/métodos , Cóclea/fisiopatología , Implantación Coclear/métodos , Pérdida Auditiva Sensorineural/rehabilitación , Monitoreo Intraoperatorio/métodos , Percepción del Habla , Adolescente , Adulto , Anciano , Niño , Preescolar , Cóclea/cirugía , Implantes Cocleares , Femenino , Audición , Pérdida Auditiva Sensorineural/fisiopatología , Humanos , Lactante , Masculino , Persona de Mediana Edad , Ventana Redonda , Adulto Joven
4.
Ear Hear ; 40(3): 577-591, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30169463

RESUMEN

OBJECTIVES: Variability in speech perception outcomes with cochlear implants remains largely unexplained. Recently, electrocochleography, or measurements of cochlear potentials in response to sound, has been used to assess residual cochlear function at the time of implantation. Our objective was to characterize the potentials recorded preimplantation in subjects of all ages, and evaluate the relationship between the responses, including a subjective estimate of neural activity, and speech perception outcomes. DESIGN: Electrocochleography was recorded in a prospective cohort of 284 candidates for cochlear implant at University of North Carolina (10 months to 88 years of ages). Measurement of residual cochlear function called the "total response" (TR), which is the sum of magnitudes of spectral components in response to tones of different stimulus frequencies, was obtained for each subject. The TR was then related to results on age-appropriate monosyllabic word score tests presented in quiet. In addition to the TR, the electrocochleography results were also assessed for neural activity in the forms of the compound action potential and auditory nerve neurophonic. RESULTS: The TR magnitude ranged from a barely detectable response of about 0.02 µV to more than 100 µV. In adults (18 to 79 years old), the TR accounted for 46% of variability in speech perception outcome by linear regression (r = 0.46; p < 0.001). In children between 6 and 17 years old, the variability accounted for was 36% (p < 0.001). In younger children, the TR accounted for less of the variability, 15% (p = 0.012). Subjects over 80 years old tended to perform worse for a given TR than younger adults at the 6-month testing interval. The subjectively assessed neural activity did not increase the information compared with the TR alone, which is primarily composed of the cochlear microphonic produced by hair cells. CONCLUSIONS: The status of the auditory periphery, particularly of hair cells rather than neural activity, accounts for a large fraction of variability in speech perception outcomes in adults and older children. In younger children, the relationship is weaker, and the elderly differ from other adults. This simple measurement can be applied with high throughput so that peripheral status can be assessed to help manage patient expectations, create individually-tailored treatment plans, and identify subjects performing below expectations based on residual cochlear function.


Asunto(s)
Implantación Coclear , Pérdida Auditiva Sensorineural/rehabilitación , Percepción del Habla , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Audiometría de Respuesta Evocada , Niño , Preescolar , Implantes Cocleares , Estudios de Cohortes , Femenino , Pérdida Auditiva Sensorineural/fisiopatología , Humanos , Lactante , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Adulto Joven
5.
Ear Hear ; 39(6): 1146-1156, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29554036

RESUMEN

OBJECTIVES: Electrocochleography is increasingly being utilized as an intraoperative monitor of cochlear function during cochlear implantation (CI). Intracochlear recordings from the advancing electrode can be obtained through the device by on-board capabilities. However, such recordings may not be ideal as a monitor because the recording electrode moves in relation to the neural and hair cell generators producing the responses. The purposes of this study were to compare two extracochlear recording locations in terms of signal strength and feasibility as intraoperative monitoring sites and to characterize changes in cochlear physiology during CI insertion. DESIGN: In 83 human subjects, responses to 90 dB nHL tone bursts were recorded both at the round window (RW) and then at an extracochlear position-either adjacent to the stapes or on the promontory just superior to the RW. Recording from the fixed, extracochlear position continued during insertion of the CI in 63 cases. RESULTS: Before CI insertion, responses to low-frequency tones at the RW were roughly 6 dB larger than when recording at either extracochlear site, but the two extracochlear sites did not differ from one another. During CI insertion, response losses from the promontory or adjacent to the stapes stayed within 5 dB in ≈61% (38/63) of cases, presumably indicating atraumatic insertions. Among responses which dropped more than 5 dB at any time during CI insertion, 12 subjects showed no response recovery, while in 13, the drop was followed by partial or complete response recovery by the end of CI insertion. In cases with recovery, the drop in response occurred relatively early (<15 mm insertion) compared to those where there was no recovery. Changes in response phase during the insertion occurred in some cases; these may indicate a change in the distributions of generators contributing to the response. CONCLUSIONS: Monitoring the electrocochleography during CI insertion from an extracochlear site reveals insertions that are potentially atraumatic, show interaction with cochlear structures followed by response recovery, or show interactions such that response losses persist to the end of recording.


Asunto(s)
Audiometría de Respuesta Evocada , Implantación Coclear/métodos , Implantes Cocleares , Monitoreo Intraoperatorio , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Humanos , Masculino , Persona de Mediana Edad , Monitoreo Fisiológico , Ventana Redonda , Adulto Joven
6.
Ear Hear ; 36(2): 249-60, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25259669

RESUMEN

OBJECTIVES: The goal was to measure the magnitude of cochlear responses to sound in pediatric cochlear implant recipients at the time of implantation and to correlate this magnitude with subsequent speech perception outcomes. DESIGN: A longitudinal cohort study of pediatric cochlear implant recipients was undertaken. Intraoperative electrocochleographic (ECoG) recordings were obtained from the round window in response to a frequency series at 90 dB nHL in 77 children totaling 89 ears (12 were second side surgeries) just before device insertion. The increase in intraoperative time was approximately 10 min. An ECoG "total response" metric was derived from the summed magnitudes of significant responses to the first, second, and third harmonics across a series of frequencies. A subset of these children reached at least 9 months of implant use and were old enough for the phonetically balanced kindergarten (PB-k) word test to be administered (n = 26 subjects and 28 ears). PB-k scores were compared to the ECoG total response and other biologic and audiologic variables using univariate and multiple linear regression analyses. RESULTS: ECoG responses were measurable in almost all ears (87 of 89). The range of ECoG total response covered about 60 dB (from ~0.05 to 50 µV). Analyzing individual ECoG recordings in bilaterally implanted children revealed poor concordance between the measured response in the first versus second ear implanted (r = 0.21; p = 0.13; n = 12). In a univariate linear regression, the ECoG total response was significantly correlated with PB-k scores in the subset of 26 subjects who were able to be tested and accounted for 32% of the variance (p = 0.002, n = 28). Preoperative pure-tone average (PTA) accounted for slightly more of the variance (r = 0.37, p = 0.001). However, ECoG total response and PTA were significantly but only weakly correlated (r = 0.14, p = 0.001). Other significant predictors of speech performance included hearing stability (stable versus progressive) and age at testing (22 and 16% of the variance, respectively). In multivariate analyses with these four factors, the ECoG accounted for the most weight (ß = 0.36), followed by PTA (ß = 0.26). In a hierarchical multiple regression analysis, the most parsimonious models that best predicted speech perception outcomes included three variables: ECoG total response, and any two of preoperative PTA, age at testing, or hearing stability. The various three factor models each predicted approximately 50% of the variance in word scores. Without the ECoG total response, the other three factors predicted 36% of variance. CONCLUSIONS: Intraoperative round window ECoG recordings are reliably and easily obtained in pediatric cochlear implant recipients. The ECoG total response is significantly correlated with speech perception outcomes in pediatric implant recipients and can account for a comparable or greater proportion of variance in speech perception than other bio-audiologic factors. Intraoperative recordings can potentially provide useful prognostic information about acquisition of open set speech perception in implanted children.


Asunto(s)
Pérdida Auditiva/rehabilitación , Ventana Redonda/fisiopatología , Percepción del Habla , Adolescente , Audiometría de Respuesta Evocada , Niño , Preescolar , Implantación Coclear/métodos , Estudios de Cohortes , Femenino , Pérdida Auditiva/fisiopatología , Humanos , Lactante , Cuidados Intraoperatorios , Modelos Lineales , Estudios Longitudinales , Masculino , Análisis Multivariante , Pronóstico , Estudios Prospectivos , Resultado del Tratamiento
7.
J Neurophysiol ; 111(3): 580-93, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24133227

RESUMEN

Almost all patients who receive cochlear implants have some acoustic hearing prior to surgery. Electrocochleography (ECoG), or electrophysiological measures of cochlear response to sound, can identify remaining auditory nerve activity that is the basis for this residual hearing and can record potentials from hair cells that are no longer functionally connected to nerve fibers. The ECoG signal is therefore complex, being composed of both hair cell and neural signals. To identify signatures of different sources in the recorded potentials, we collected ECoG data across frequency and intensity from the round window of gerbils before and after treatment with kainic acid, a neurotoxin. Distortions in the recorded waveforms were produced by different sources over different ranges of frequency and intensity. In response to tones at low frequencies and low-to-moderate intensities, the major source of distortion was from neural phase-locking that was sensitive to kainic acid. At high intensities at all frequencies, the distortion was not sensitive to kainic acid and was consistent with asymmetric saturation of the hair cell transducer current. In addition to loss of phase-locking, changes in the envelope after kainic acid treatment indicate that sustained neural firing combines with receptor potentials from hair cells to produce the envelope of the response to tones. These results provide baseline data to interpret comparable recordings from human cochlear implant recipients.


Asunto(s)
Potenciales Microfónicos de la Cóclea , Células Ciliadas Auditivas/fisiología , Estimulación Acústica , Potenciales de Acción , Animales , Audiometría de Respuesta Evocada , Nervio Coclear/fisiología , Gerbillinae , Masculino
8.
Front Pharmacol ; 15: 1348172, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38344174

RESUMEN

Introduction: One major obstacle in validating drugs for the treatment or prevention of hearing loss is the limited data available on the distribution and concentration of drugs in the human inner ear. Although small animal models offer some insights into inner ear pharmacokinetics, their smaller organ size and different barrier (round window membrane) permeabilities compared to humans can complicate study interpretation. Therefore, developing a reliable large animal model for inner ear drug delivery is crucial. The inner and middle ear anatomy of domestic pigs closely resembles that of humans, making them promising candidates for studying inner ear pharmacokinetics. However, unlike humans, the anatomical orientation and tortuosity of the porcine external ear canal frustrates local drug delivery to the inner ear. Methods: In this study, we developed a surgical technique to access the tympanic membrane of pigs. To assess hearing pre- and post-surgery, auditory brainstem responses to click and pure tones were measured. Additionally, we performed 3D segmentation of the porcine inner ear images and used this data to simulate the diffusion of dexamethasone within the inner ear through fluid simulation software (FluidSim). Results: We have successfully delivered dexamethasone and dexamethasone sodium phosphate to the porcine inner ear via the intratympanic injection. The recorded auditory brainstem measurements revealed no adverse effects on hearing thresholds attributable to the surgery. We have also simulated the diffusion rates for dexamethasone and dexamethasone sodium phosphate into the porcine inner ear and confirmed the accuracy of the simulations using in-vivo data. Discussion: We have developed and characterized a method for conducting pharmacokinetic studies of the inner ear using pigs. This animal model closely mirrors the size of the human cochlea and the thickness of its barriers. The diffusion time and drug concentrations we reported align closely with the limited data available from human studies. Therefore, we have demonstrated the potential of using pigs as a large animal model for studying inner ear pharmacokinetics.

9.
Brain Sci ; 13(2)2023 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-36831873

RESUMEN

Intraoperative electrocochleography (ECOG) is performed using a single low-frequency acoustic stimulus (e.g., 500 Hz) to monitor cochlear microphonics (CM) during cochlear implant (CI) electrode insertion. A decrease in CM amplitude is commonly associated with cochlear trauma and is used to guide electrode placement. However, advancement of the recording electrode beyond the sites of CM generation can also lead to a decrease in CM amplitude and is sometimes interpreted as cochlear trauma, resulting in unnecessary electrode manipulation and increased risk of cochlear trauma during CI electrode placement. In the present study, multi-frequency ECOG was used to monitor CM during CI electrode placement. The intraoperative CM tracings were compared with electrode scan measurements, where CM was measured for each of the intracochlear electrodes. Comparison between the peak CM amplitude measured during electrode placement and electrode scan measurements was used to differentiate between different mechanisms for decrease in CM amplitude during CI electrode insertion. Analysis of the data shows that both multi-frequency electrocochleography and electrode scan could potentially be used to differentiate between different mechanisms for decreasing CM amplitude and providing appropriate feedback to the surgeon during CI electrode placement.

10.
Front Neurol ; 14: 1104574, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37483448

RESUMEN

Cochlear synaptopathy is the loss of synapses between the inner hair cells and the auditory nerve despite survival of sensory hair cells. The findings of extensive cochlear synaptopathy in animals after moderate noise exposures challenged the long-held view that hair cells are the cochlear elements most sensitive to insults that lead to hearing loss. However, cochlear synaptopathy has been difficult to identify in humans. We applied novel algorithms to determine hair cell and neural contributions to electrocochleographic (ECochG) recordings from the round window of animal and human subjects. Gerbils with normal hearing provided training and test sets for a deep learning algorithm to detect the presence of neural responses to low frequency sounds, and an analytic model was used to quantify the proportion of neural and hair cell contributions to the ECochG response. The capacity to detect cochlear synaptopathy was validated in normal hearing and noise-exposed animals by using neurotoxins to reduce or eliminate the neural contributions. When the analytical methods were applied to human surgical subjects with access to the round window, the neural contribution resembled the partial cochlear synaptopathy present after neurotoxin application in animals. This result demonstrates the presence of viable hair cells not connected to auditory nerve fibers in human subjects with substantial hearing loss and indicates that efforts to regenerate nerve fibers may find a ready cochlear substrate for innervation and resumption of function.

11.
iScience ; 26(6): 106789, 2023 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-37213232

RESUMEN

Delivery of pharmaceutical therapeutics to the inner ear to treat and prevent hearing loss is challenging. Systemic delivery is not effective as only a small fraction of the therapeutic agent reaches the inner ear. Invasive surgeries to inject through the round window membrane (RWM) or cochleostomy may cause damage to the inner ear. An alternative approach is to administer drugs into the middle ear using an intratympanic injection, with the drugs primarily passing through the RWM to the inner ear. However, the RWM is a barrier, only permeable to a small number of molecules. To study and enhance the RWM permeability, we developed an ex vivo porcine RWM model, similar in structure and thickness to the human RWM. The model is viable for days, and drug passage can be measured at multiple time points. This model provides a straightforward approach to developing effective and non-invasive delivery methods to the inner ear.

12.
Ear Hear ; 33(4): 534-42, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22436408

RESUMEN

OBJECTIVES: Cochlear implants (CI) perform especially well if residual acoustic hearing is retained and combined with the CI in the same ear (also termed hybrid or electric-acoustic stimulation). However, in most CI patients, residual hearing is at least partially compromised during surgery, and in some it is lost completely. At present, clinicians have no feedback on the functional status of the cochlea during electrode insertion. Development of an intraoperative physiological recording algorithm during electrode insertion could serve to detect reversible cochlear trauma and optimal placement relative to surviving hair cells. In this report, an animal model was used to assist in determining physiological markers for these conditions using a flexible electrode similar to human surgery. DESIGN: The animal model was the normal-hearing gerbil. The flexible electrodes had 1 to 2 platinum-iridium contacts embedded in a 200 µm diameter silastic carrier. As control experiments some insertions were also made with much smaller (50 µm diameter) rigid electrodes. In either case, the electrode was positioned at or just inside the round window membrane and subsequently advanced into the scala tympani longitudinally in 50 to 100 µm increments. After each advancement, acoustic stimulation was used to elicit a cochlear microphonic (CM) and compound action potential (CAP). Stimuli were suprathreshold tone bursts of 1 to 16 kHz in octave steps with 2 msec rise and fall times and a 10 msec plateau. Anatomical integrity of the cochlea was subsequently assessed using a whole-mount preparation. RESULTS: In contrast with the CAP, which was relatively stable during insertion, the CM showed a variety of changes related to electrode movement. To tone bursts of 1 to 8 kHz the CM typically remained stable or increased during the insertion before contact with cochlear structures. After contact, the potentials often dropped dramatically. The CM to 16 kHz was the most variable; in some cases it increased but in other cases it decreased early in the insertion and later showed large and abrupt increases. In some instances, this pattern was seen to progressively lower frequencies as well. Histological analysis and the gerbil frequency map indicate that electrode travel was limited to the basal turn (~4 mm from the hook) and did not intrude into the characteristic frequency regions of most frequencies used. CONCLUSIONS: First, the CM provides a more sensitive indication of cochlear trauma than does the CAP. Second, stable or steady increases in the CM are a physiological marker for unimpeded travel through the scala tympani as the electrode approaches responding hair cells. Third, abrupt reductions in the CM across frequency are a physiological marker of contact with cochlear structures. Fourth, abrupt increases after a decline, which occurred primarily to 16 kHz but to a lesser degree to other frequencies as well, are a physiological marker for a release from contact. The interpretation is that as the tip of the electrode bends the shaft can move in the mediolateral dimension, sometimes contacting the basilar membrane and sometimes not. Overall, the results indicate that recordings during cochlear implantations can provide valuable feedback to the surgeon regarding electrode position and the integrity of surviving hair cells.


Asunto(s)
Implantación Coclear/métodos , Implantes Cocleares , Potenciales Microfónicos de la Cóclea/fisiología , Potenciales Evocados Auditivos/fisiología , Células Ciliadas Auditivas/fisiología , Estimulación Acústica , Animales , Electrodos Implantados , Gerbillinae , Monitoreo Intraoperatorio
13.
Otol Neurotol ; 43(7): 781-788, 2022 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-35763496

RESUMEN

HYPOTHESIS: Characterize the contribution of the auditory nerve neurophonic (ANN) to electrocochleography (ECochG) of pediatric cochlear implant (CI) recipients with and without auditory nerve spectrum disorder (ANSD). BACKGROUND: ECochG is an emerging technique for predicting outcomes in CI recipients. Its utility may be increased by separating the cochlear microphonic (CM), produced by hair cells, from the ANN, the evoked potential correlate of neural phase-locking, which are mixed in the ongoing portion of the response to low frequency tone bursts. METHODS: Responses to tone bursts of different frequency and intensities were recorded from the round window of pediatric CI recipients. Separation of the CM and ANN was performed using a model of the underlying processes that lead to the shapes of the observed waveforms. RESULTS: Preoperative mean pure tone amplitudes of the included ANSD (n = 36) and non-ANSD subjects (n = 123), were similar (89.5 and 93.5, p = 0.1). Total of 1,024 ECochG responses to frequency and intensity series were recorded. The mean correlation ( r ) between the input and the modeled signals was 0.973 ± 0.056 (standard deviation). The ANN magnitudes were higher in the ANSD group (ANOVAs, F = 26.5 for frequency and 21.9 for intensity, df's = 1, p 's < 0.001). However, its relative contribution to the overall signal was lower (ANOVAs, F = 25.8 and 12.1, df = 1, p 's < 0.001). CONCLUSIONS: ANN was detected in low frequency ECochG responses but not high frequency responses in both ANSD and non-ANSD subjects. ANSD subjects, evidence of neural contribution in responses to low frequency stimuli was highly variable and often comparable to signals recorded in non-ANSD subjects. The computational model revealed that on average the ANN comprised a lower proportion of the overall signal than in non-ANSD subjects.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Enfermedades del Nervio Vestibulococlear , Audiometría de Respuesta Evocada/métodos , Niño , Implantación Coclear/métodos , Nervio Coclear/fisiología , Pérdida Auditiva Central , Humanos
14.
J Assoc Res Otolaryngol ; 23(3): 351-363, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35254541

RESUMEN

Using electrocochleography, the summating potential (SP) is a deflection from baseline to tones and an early rise in the response to clicks. Here, we use normal hearing gerbils and gerbils with outer hair cells removed with a combination of furosemide and kanamycin to investigate cellular origins of the SP. Round window electrocochleography to tones and clicks was performed before and after application of tetrodotoxin to prevent action potentials, and then again after kainic acid to prevent generation of an EPSP. With appropriate subtractions of the response curves from the different conditions, the contributions to the SP from outer hair cells, inner hair cell, and neural "spiking" and "dendritic" responses were isolated. Like hair cells, the spiking and dendritic components had opposite polarities to tones - the dendritic component had negative polarity and the spiking component had positive polarity. The magnitude of the spiking component was larger than the dendritic across frequencies and intensities. The onset to tones and to clicks followed a similar sequence; the outer hair cells responded first, then inner hair cells, then the dendritic component, and then the compound action potential of the spiking response. These results show the sources of the SP include at least the four components studied, and that these have a mixture of polarities and magnitudes that vary across frequency and intensity. Thus, multiple possible interactions must be considered when interpreting the SP for clinical uses.


Asunto(s)
Potenciales Microfónicos de la Cóclea , Nervio Coclear , Potenciales de Acción , Audiometría de Respuesta Evocada , Nervio Coclear/fisiología , Células Ciliadas Auditivas Internas/fisiología , Células Ciliadas Auditivas Externas
15.
Front Neurosci ; 16: 1039986, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36570833

RESUMEN

Objective: To investigate the electrophysiology of the cochlear summating potential (SP) in patients with Meniere's disease (MD). Although long considered a purely hair cell potential, recent studies show a neural contribution to the SP. Patients with MD have an enhanced SP compared to those without the disease. Consequently, this study was to determine if the enhancement of the SP was in whole or part due to neural dysfunction. Design: Study participants included 41 adults with MD and 53 subjects with auditory neuropathy spectrum disorder (ANSD), undergoing surgery where the round window was accessible. ANSD is a condition with known neural dysfunction, and thus represents a control group for the study. The ANSD subjects and 17 of the MD subjects were undergoing cochlear implantation (CI) surgery; the remaining MD subjects were undergoing either endolymphatic sac decompression or labyrinthectomy to alleviate the symptoms of MD. Electrocochleography was recorded from the round window using high intensity (90 dB nHL) tone bursts. The SP and compound action potential (CAP) were measured to high frequencies (> = 2 kHz) and the SP, cochlear microphonic (CM) and auditory nerve neurophonic (ANN) to low frequencies. Linear mixed models were used to assess differences between MD and ANSD subjects. Results: Across frequencies, the MD subjects had smaller alternating current (AC) response than the ANSD subjects (F = 31.61,534, p < 0.001), but the SP magnitudes were larger (F = 94.31,534, p < 0.001). For frequencies less than 4 kHz the SP magnitude in the MD group was significantly correlated with the magnitude of the CM (p's < 0.001) but not in the ANSD group (p's > 0.05). Finally, the relative proportions of both ANN and CAP were greater in MD compared to ANSD subjects. The shapes of the waveforms in the MD subjects showed the presence of multiple components contributing to the SP, including outer and inner hair cells and neural activity. Conclusion: The results support the view that the increased negative polarity SP in MD subjects is due to a change in the operating point of hair cells rather than a loss of neural contribution. The steady-state SP to tones in human subjects is a mixture of different sources with different polarities.

16.
Otol Neurotol ; 43(8): 915-923, 2022 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-35861658

RESUMEN

OBJECTIVE: 1) To determine the relationship of electrocochleography (ECochG) responses measured on the promontory with responses measured at the round window (RW) and various intracochlear sites. 2) To evaluate if promontory ECochG responses correlate with postoperative speech-perception performance using the cochlear implant (CI). STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral center. PATIENTS AND INTERVENTIONS: Ninety-six adult CI recipients with no cochlear malformations or previous otologic surgery. MAIN OUTCOME MEASURES: Acoustically evoked ECochG responses were measured intraoperatively at both extracochlear and intracochlear locations. ECochG total response (ECochG-TR), a measure of residual cochlear function, was calculated by summing the fast Fourier transformation amplitudes in response to 250-Hz to 2-kHz acoustic stimuli. Speech-perception performance was measured at 3 months. RESULTS: There were strong linear correlations for promontory ECochG-TR with the ECochG-TRs measured at the RW ( r = 0.95), just inside scala tympani ( r = 0.91), and after full insertion ( r = 0.83). For an individual subject, the morphology of the ECochG response was similar in character across all positions; however, the response amplitude increased from promontory to RW (~1.6-fold) to just inside scala tympani (~2.6-fold), with the largest response at full insertion (~13.1-fold). Promontory ECochG-TR independently explained 51.8% of the variability ( r2 ) in consonant-nucleus-consonant at 3 months. CONCLUSIONS: Promontory ECochG recordings are strongly correlated with responses previously recorded at extracochlear and intracochlear sites and explain a substantial portion of the variability in CI performance. These findings are a critical step in supporting translation of transtympanic ECochG into the clinic preoperatively to help predict postoperative CI performance.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Percepción del Habla , Adulto , Audiometría de Respuesta Evocada , Humanos , Estudios Prospectivos , Habla
17.
J Comp Neurol ; 529(4): 757-785, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32632959

RESUMEN

Light sheet fluorescence microscopy (LSFM) provides a rapid and complete three-dimensional image of the cochlea. The method retains anatomical relationships-on a micrometer scale-between internal structures such as hair cells, basilar membrane (BM), and modiolus with external surface structures such as the round and oval windows. Immunolabeled hair cells were used to visualize the spiraling BM in the intact cochlea without time intensive dissections or additional histological processing; yet material prepared for LSFM could be rehydrated, the BM dissected out and reimaged at higher resolution with the confocal microscope. In immersion-fixed material, details of the cochlear vasculature were seen throughout the cochlea. Hair cell counts (both inner and outer) as well as frequency maps of the BM were comparable to those obtained by other methods, but with the added dimension of depth. The material provided measures of angular, linear, and vector distance between characteristic frequency regions along the BM. Thus, LSFM provides a unique ability to rapidly image the entire cochlea in a manner applicable to model and interpret physiological results. Furthermore, the three-dimensional organization of the cochlea can be studied at the organ and cellular level with LSFM, and this same material can be taken to the confocal microscope for detailed analysis at the subcellular level.


Asunto(s)
Cóclea/anatomía & histología , Cóclea/química , Imagenología Tridimensional/métodos , Animales , Cóclea/citología , Gerbillinae , Microscopía Confocal/métodos , Microscopía Fluorescente/métodos
18.
Otol Neurotol ; 41(6): e686-e694, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32569244

RESUMEN

BACKGROUND: Angular insertion depth (AID) of the electrode array provides valuable information regarding intracochlear positioning, which can be used to predict outcomes and optimize performance. While computed tomography (CT) offers high-resolution imaging, there is a need to develop technology to accurately determine AID from intraoperative x-rays acquired at unknown angles. METHODS: An algorithm was developed using a three-dimensional model of the scala tympani to estimate AID from an x-ray acquired at an unknown angle. The model is manipulated over the x-ray until the projection angle is inferred and the location of the round window and individual electrode contacts are identified. Validation of the algorithm involved 1) assessing accuracy with deviation from cochlear view by comparing AID determined with simulated x-rays to those determined with CT in a temporal bone model, and 2) assessing reproducibility in the clinical setting, by comparing intra- and inter-rater reliability with intraoperative x-ray in cochlear implant (CI) recipients, which were subsequently compared to AID determined with postoperative CT. RESULTS: Estimates of AID from x-rays were generally within 10 degrees of CT regardless of deviation from cochlear view. Excluding two outliers with poor imaging quality, the intraclass correlation coefficients for intra- and inter-rater reliability were excellent (0.991 and 0.980, respectively). CONCLUSION: With intraoperative x-rays of sufficient quality, the helical scala tympani model can be used to accurately and reliably determine AID without the need to specify a preferred image angle. The application can therefore be used in most CI recipients when a postoperative CT is not available.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Cóclea/diagnóstico por imagen , Cóclea/cirugía , Humanos , Reproducibilidad de los Resultados , Rampa Timpánica/diagnóstico por imagen , Rampa Timpánica/cirugía , Rayos X
19.
Otol Neurotol ; 41(3): e369-e377, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31923083

RESUMEN

HYPOTHESIS: Intraoperative electrocochleography (ECochG) can differentiate hair cell and neural dysfunction caused by a vestibular schwannoma (VS) and help define the site of lesion as peripheral or central to the spiral ganglion. BACKGROUND: Hearing loss in patients with a VS can be caused by both sensory (cochlear) and neural dysfunction. METHODS: Round-window ECochG using low and high-frequency tone bursts was performed in 49 subjects with a VS. Responses were analyzed for magnitude, spectrum, and shape of the time waveform. Components examined included the cochlear microphonic, auditory nerve neurophonic, compound action potential (CAP), and summating potential (SP). RESULTS: Variability in the summed response magnitudes across frequency, or "total response" (ECochG-TR), varied from 0.1 to 100 µV. Responses were larger for lower frequencies. Subjective estimates revealed a wide range of neural contributions from the auditory nerve neurophonic to low frequencies and the CAP to high frequencies. Cases with larger CAPs had smaller SPs. The correlation of ECochG-TR, with word recognition score (WRS), was moderate (r = 0.67), as well as the correlation between pure-tone averages and ECochG (r = 0.63). The cochlea remained functional in two cases of sudden sensorineural hearing loss with 0% WRS. CONCLUSION: Reduced ECochG-TR and neural activity in many cases indicates both sensory and neural deficits. Smaller SPs when CAPs are present indicate a neural contribution to the SP. Good cochlear function with 0% WRS, and cases of sudden sensorineural hearing loss with retained cochlear function, indicate retrocochlear effects, typically proximal to the spiral ganglion cells.


Asunto(s)
Audiometría de Respuesta Evocada , Neuroma Acústico , Cóclea , Nervio Coclear , Humanos , Neuroma Acústico/cirugía , Ventana Redonda
20.
J Neurosci ; 27(48): 13108-16, 2007 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-18045905

RESUMEN

We have identified a novel nucleus of the mammalian brain and termed it the tectal longitudinal column (TLC). Basic histologic stains, tract-tracing techniques and three-dimensional reconstructions reveal that the rat TLC is a narrow, elongated structure spanning the midbrain tectum longitudinally. This paired nucleus is located close to the midline, immediately dorsal to the periaqueductal gray matter. It occupies what has traditionally been considered the most medial region of the deep superior colliculus and the most medial region of the inferior colliculus. The TLC differs from the neighboring nuclei of the superior and inferior colliculi and the periaqueductal gray by its distinct connections and cytoarchitecture. Extracellular electrophysiological recordings show that TLC neurons respond to auditory stimuli with physiologic properties that differ from those of neurons in the inferior or superior colliculi. We have identified the TLC in rodents, lagomorphs, carnivores, nonhuman primates, and humans, which indicates that the nucleus is conserved across mammals. The discovery of the TLC reveals an unexpected level of longitudinal organization in the mammalian tectum and raises questions as to the participation of this mesencephalic region in essential, yet completely unexplored, aspects of multisensory and/or sensorimotor integration.


Asunto(s)
Neuronas/fisiología , Techo del Mesencéfalo/citología , Techo del Mesencéfalo/fisiología , Estimulación Acústica/métodos , Potenciales de Acción/fisiología , Animales , Vías Auditivas/fisiología , Mapeo Encefálico , Recuento de Células/métodos , Femenino , Humanos , Imagenología Tridimensional/métodos , Masculino , Ratas , Ratas Sprague-Dawley , Estilbamidinas/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA