Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-38336872

RESUMEN

OBJECTIVES: Interstitial lung disease (ILD) in connective tissue diseases (CTD) have highly variable morphology. We aimed to identify imaging features and their impact on ILD progression, mortality and immunosuppression response. METHODS: Patients with CTD-ILD had high-resolution chest computed tomography (HRCT) reviewed by expert radiologists blinded to clinical data for overall imaging pattern (usual interstitial pneumonia [UIP]; non-specific interstitial pneumonia [NSIP]; organizing pneumonia [OP]; fibrotic hypersensitivity pneumonitis [fHP]; and other). Transplant-free survival and change in percent-predicted forced vital capacity (FVC) were compared using Cox and linear mixed effects models adjusted for age, sex, smoking, and baseline FVC. FVC decline after immunosuppression was compared with pre-treatment. RESULTS: Of 645 CTD-ILD patients, the frequent CTDs were systemic sclerosis (n = 215), rheumatoid arthritis (n = 127), and inflammatory myopathies (n = 100). NSIP was the most common pattern (54%), followed by UIP (20%), fHP (9%), and OP (5%). Compared with UIP, FVC decline was slower for NSIP (1.1%/year, 95%CI 0.2, 1.9) and OP (3.5%/year, 95%CI 2.0, 4.9), and mortality was lower for NSIP (HR 0.65, 95%CI 0.45, 0.93) and OP (HR 0.18, 95%CI 0.05, 0.57), but higher in fHP (HR 1.58, 95%CI 1.01, 2.40). The extent of fibrosis also predicted FVC decline and mortality. After immunosuppression, FVC decline was slower compared with pre-treatment in NSIP (by 2.1%/year, 95%CI 1.4, 2.8), with no change for UIP or fHP. CONCLUSION: Multiple radiologic patterns are possible in CTD-ILD, including a fHP pattern. NSIP and OP were associated with better outcomes and response to immunosuppression, while fHP had worse survival compared with UIP.

2.
Chest ; 164(6): 1466-1475, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37541339

RESUMEN

BACKGROUND: Clinical practice guidelines separately describe radiologic patterns of usual interstitial pneumonia (UIP) and fibrotic hypersensitivity pneumonitis (fHP), without direction on whether or how to apply these approaches concurrently within a single patient. RESEARCH QUESTION: How can we integrate guideline-defined radiologic patterns to diagnose interstitial lung disease (ILD) and what are the pitfalls associated with described patterns that require reassessment in future guidelines? STUDY DESIGN AND METHODS: Patients from the Canadian Registry for Pulmonary Fibrosis underwent detailed reevaluation in standardized multidisciplinary discussion. CT scan features were quantified by chest radiologists masked to clinical data, and guideline-defined patterns were assigned. Clinical data then were provided to the radiologist and an ILD clinician, who jointly determined the leading diagnosis. RESULTS: Clinical-radiologic diagnosis in 1,593 patients was idiopathic pulmonary fibrosis (IPF) in 26%, fHP in 12%, connective tissue disease-associated ILD (CTD-ILD) in 34%, idiopathic pneumonia with autoimmune features in 12%, and unclassifiable ILD in 10%. Typical and probable UIP patterns corresponded to a diagnosis of IPF in 66% and 57% of patients, respectively. Typical fHP pattern corresponded to an fHP clinical diagnosis in 65% of patients, whereas compatible fHP was nonspecific and associated with CTD-ILD or IPAF in 48% of patients. No pattern ruled out CTD-ILD. Gas trapping affecting > 5% of lung parenchyma on expiratory imaging was an important feature broadly separating compatible and typical fHP from other patterns (sensitivity, 0.77; specificity, 0.91). INTERPRETATION: An integrated approach to guideline-defined UIP and fHP patterns is feasible and supports > 5% gas trapping as an important branch point. Typical or probable UIP and typical fHP patterns have moderate predictive values for a corresponding diagnosis of IPF and fHP, although occasionally confounded by CTD-ILD; compatible fHP is nonspecific.


Asunto(s)
Alveolitis Alérgica Extrínseca , Fibrosis Pulmonar Idiopática , Enfermedades Pulmonares Intersticiales , Humanos , Canadá , Fibrosis Pulmonar Idiopática/diagnóstico , Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Alveolitis Alérgica Extrínseca/diagnóstico por imagen
3.
Radiology ; 260(2): 560-7, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21555348

RESUMEN

PURPOSE: To compare the effective fetal dose reduction at different stages of gestation during maternal computed tomographic (CT) pulmonary angiography by using traditional lead apron and bismuth-antimony shields combined with limited z-axis and tube current. MATERIALS AND METHODS: Phantom with gravid prosthesis, 0.5-mm lead, and two grades of bismuth-antimony shield was used. Thermoluminescent dosimeters (TLDs) measured radiation in the first- to third-trimester uterus. Fetal dose was determined for each gestation by using 100 kVp to the costophrenic angles (CPAs) with and without shielding for a total of 12 scans. Eight third-trimester scans were used to compare shields using 120 kVp to CPAs versus those using 100 kVp to the diaphragm. RESULTS: Average fetal dose increased with gestation with use of 100 kVp to CPAs, from 0.11 mGy in first trimester to 0.50 mGy in third trimester. Average third-trimester unshielded fetal dose was reduced from 0.82 mGy by using 120 kVp to CPAs to 0.17 mGy (79%, P < .001) by using 100 kVp to the diaphragm. Lead apron reduced dose more than either of the bismuth-antimony shields (72%-79% vs 57%-81%) with use of 100 kVp to CPAs. Shields reduced the dose by 73% (lead), 62% (90% attenuation bismuth-antimony), and 72% (95% attenuation bismuth-antimony) (P < .01) at 120 kVp to CPAs. No significant difference between shields was demonstrated with 100 kVp to the diaphragm (P < .01). Maternal dose was 8.13 mSv at 120 kVp to CPAs, 4.90 mSv at 100 kVp to CPAs, and 4.02 mSv at 100 kVp to the diaphragm. CONCLUSION: Reducing voltage and limiting z-axis is more effective than shields at reducing fetal dose. Shielding improves reduction with no significant difference between lead and bismuth-antimony shields when conservative scanning parameters are observed.


Asunto(s)
Angiografía/métodos , Feto/efectos de la radiación , Protección Radiológica/instrumentación , Tomografía Computarizada por Rayos X , Antimonio , Bismuto , Femenino , Edad Gestacional , Humanos , Imagenología Tridimensional , Plomo , Fantasmas de Imagen , Embarazo , Dosis de Radiación , Estadísticas no Paramétricas , Dosimetría Termoluminiscente
4.
Healthc Q ; 12 Spec No Patient: 15-22, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19667773

RESUMEN

The use of computed tomography (CT) is growing, and, consequently, the associated radiation dose to patients is increasing as well. There is also increasing evidence linking the radiation dose within the range of diagnostic CT with a significantly increased risk of malignancy. These two factors combine to make radiation dose from diagnostic CT a public health concern. In order to practise to the best of our abilities and avoid harming patients, the radiation dose from CT must be minimized. Administrators, technologists, radiologists and other physicians are encouraged to work toward this goal through the use of education and a multi-faceted team approach. The objective of this paper is to educate healthcare professionals about the radiation dose from diagnostic CT, including utilization rates, typical examination doses and the risks of this radiation. Our experience in Saskatchewan is discussed. Suggestions regarding CT dose management and optimization are highlighted.


Asunto(s)
Administradores de Hospital/educación , Dosis de Radiación , Tomografía Computarizada por Rayos X , Canadá , Humanos , Neoplasias/etiología , Medición de Riesgo
5.
Radiology ; 249(2): 572-80, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18780826

RESUMEN

PURPOSE: To assess the effectiveness of in-plane bismuth thyroid shields and a z-axis automatic tube current modulation (ATCM) technique with respect to dose reduction and image noise in the thyroid and other regional tissues during neck computed tomography (CT). MATERIALS AND METHODS: Because this was a phantom study, neither institutional review board approval nor HIPAA compliance was required. A female phantom, thyroid shields, and an eight-section CT scanner were used. Radiation dose was measured by using thermoluminescent dosimetry (TLD) chips placed in the phantom's thyroid, cervical bone marrow, and soft tissues. Scans were performed by using fixed tube current and a z-axis ATCM technique with and without shields. Image noise was quantified as the standard deviation of the attenuation value (in Hounsfield units) on CT images. RESULTS: Thyroid dose was 76.9 mGy with an unshielded fixed tube current technique. Use of shields and ATCM reduced this dose to 44.7 mGy (42% reduction, P < .001) and 17.0 mGy (78% reduction, P < .001), respectively. The combination of shields and ATCM further reduced this dose to between 11.9 and 12.9 mGy (83%-85% reduction, P < .001), depending on the shield's presence in the scout scan. ATCM resulted in minimized tube current throughout the neck, which reduced dose-length product across the entire scan volume by 60% (926 vs 368 mGy . cm). Thyroid bed noise was lowest (3.9 HU) during the fixed tube current technique without shields, with noise slightly higher (6.9 HU) with the unshielded ATCM technique (P < .001). Thyroid image noise was markedly higher when using shields (P < .001), with noise measuring between 74 and 113 HU for fixed tube current and ATCM scans. CONCLUSION: z-Axis ATCM is more effective than shields at reducing thyroid radiation dose during neck CT. Shields combined with ATCM slightly further reduces dose; however, this is associated with higher image noise.


Asunto(s)
Protección Radiológica/instrumentación , Glándula Tiroides/efectos de la radiación , Tomografía Computarizada por Rayos X , Bismuto , Humanos , Fantasmas de Imagen , Dosis de Radiación , Dosimetría Termoluminiscente
6.
J Med Imaging Radiat Sci ; 47(3): 243-250, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31047289

RESUMEN

BACKGROUND: There is ionizing radiation and associated risk from many medical imaging examinations, especially computed tomography (CT). Unfortunately, health care providers often have limited knowledge regarding radiation dose levels and potential risk. RESEARCH OBJECTIVES: To assess knowledge of dose levels and risk among referring physicians, imaging technologists, and radiologists in Saskatoon, Saskatchewan, and to identify potential differences between and within those groups. MATERIALS AND METHODS: A survey was designed and administered to health care professionals. RESULTS: A total of 308 of 328 surveys were completed (91% response rate). Overall 73% of physicians, 97% of radiologists, and 76% of technologists correctly believed that there is a risk for cancer from an abdomen-pelvic CT scan. Although only 18% of physicians, 28% of radiologists, and 22% of technologists selected the most appropriate estimate of abdominal-pelvic CT dose in terms of chest x-ray equivalents, this is similar to other reported studies. Physicians and technologists who use CT were more likely to select the correct dose than those who do not. Most respondents (91% of physicians, 100% of radiologists, and 100% of technologists) felt that pregnant patients should always be informed about radiation dose as a risk. Although frequency of discussing risk decreased with increasing patient age, technologists were more likely to discuss risk at any age. A total of 93% of respondents expressed interest in receiving dose feedback from medical imaging procedures. CONCLUSIONS: Radiologists and technologists generally showed better knowledge than referring physicians. Among physicians and technologists, knowledge was better in those who use CT than those who do not.

7.
Can J Neurol Sci ; 32(4): 465-71, 2005 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-16408576

RESUMEN

OBJECTIVE: Carotid ultrasound (US) is a screening test for patients with transient ischemic attacks (TIAs) or stroke who then undergo Digital Subtraction Angiogram (DSA) or Magnetic Resonance Angiography (MRA). Gold standard DSA is invasive with inherent risks and costs. MRA is an evolving technology. This study compares reliability of MRA and US modes with DSA in determining degree of internal carotid artery stenosis. METHODS: A five year retrospective analysis of 140 carotid arteries from patients who had carotid US and DSA, and possibly Magnetic Resonance Angiography was undertaken. Recorded US parameters were peak systolic velocity (PSV), end diastolic velocity (EDV), and ICA/CCA peak systolic velocity ratio. The MRA and DSA parameters used NASCET technique for measuring stenosis. Statistical analysis included ROC curves and Kappa computation. RESULTS: US grading of carotid stenosis can be made more reliable by choosing appropriate parameters. The best combination of sensitivity and specificity for stenosis > 70% in our hospital was seen at PSV > 173 cm/s (sensitivity 0.87, specificity 0.8, Positive Predictive Value (PPV) 0.70, Negative Predictive Value (NPV) 0.93, kappa 0.64 and weighted kappa 0.71). MRA kappa was 0.78, (sensitivity 0.75, specificity 1.0, PPV 1.0, NPV 0.85). CONCLUSIONS: US parameters should be validated in each centre. At best, US can only approximate the accuracy of DSA, probably due to inherent limitations of this modality. Magnetic Resonance Angiography has a perfect specificity and PPV but this technique needs to be standardized. Simultaneous use of MRA and US for screening increases sensitivity to over 0.9 without compromising specificity in > 70% stenosis.


Asunto(s)
Angiografía de Substracción Digital , Arteria Carótida Interna , Estenosis Carotídea/diagnóstico por imagen , Angiografía por Resonancia Magnética , Arteria Carótida Interna/diagnóstico por imagen , Arteria Carótida Interna/patología , Estenosis Carotídea/patología , Humanos , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Ultrasonografía , Estados Unidos
8.
Eur J Radiol ; 83(7): 1199-1204, 2014 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-24838282

RESUMEN

PURPOSE: Custom bismuth-antimony shields were previously shown to reduce fetal dose by 53% on an 8DR (detector row) CT scanner without dynamic adaptive section collimation (DASC), automatic tube current modulation (ATCM) or adaptive statistical iterative reconstruction (ASiR). The purpose of this study is to compare the effective maternal and average fetal organ dose reduction both with and without bismuth-antimony shields on a 64DR CT scanner using DASC, ATCM and ASiR during maternal CTPA. MATERIALS AND METHODS: A phantom with gravid prosthesis and a bismuth-antimony shield were used. Thermoluminescent dosimeters (TLDs) measured fetal radiation dose. The average fetal organ dose and effective maternal dose were determined using 100 kVp, scanning from the lung apices to the diaphragm utilizing DASC, ATCM and ASiR on a 64DR CT scanner with and without shielding in the first and third trimester. Isolated assessment of DASC was done via comparing a new 8DR scan without DASC to a similar scan on the 64DR with DASC. RESULTS: Average third trimester unshielded fetal dose was reduced from 0.22 mGy ± 0.02 on the 8DR to 0.13 mGy ± 0.03 with the conservative 64DR protocol that included 30% ASiR, DASC and ATCM (42% reduction, P<0.01). Use of a shield further reduced average third trimester fetal dose to 0.04 mGy ± 0.01 (69% reduction, P<0.01). The average fetal organ dose reduction attributable to DASC alone was modest (6% reduction from 0.17 mGy ± 0.02 to 0.16 mGy ± 0.02, P=0.014). First trimester fetal organ dose on the 8DR protocol was 0.07 mGy ± 0.03. This was reduced to 0.05 mGy ± 0.03 on the 64DR protocol without shielding (30% reduction, P=0.009). Shields further reduced this dose to below accurately detectable levels. Effective maternal dose was reduced from 4.0 mSv on the 8DR to 2.5 mSv on the 64DR scanner using the conservative protocol (38% dose reduction). CONCLUSION: ASiR, ATCM and DASC combined significantly reduce effective maternal and fetal organ dose during CTPA. Shields continue to be an effective means of fetal dose reduction.


Asunto(s)
Feto/efectos de la radiación , Exposición Materna/prevención & control , Diagnóstico Prenatal/instrumentación , Dosis de Radiación , Protección Radiológica/instrumentación , Radiografía Torácica/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Absorción de Radiación , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Feto/diagnóstico por imagen , Humanos , Fantasmas de Imagen , Embarazo , Diagnóstico Prenatal/métodos , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Recuento Corporal Total
9.
Case Rep Radiol ; 2013: 348624, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24294535

RESUMEN

Dual left anterior descending artery (LAD) is a rare coronary anomaly that is important to recognize at coronary imaging as it may influence reperfusion strategies. Four types of dual LAD are described by the traditional literature. We present a novel case of dual LAD with coronary computed tomographic angiographic correlation that does not fit into this classification system. Rather, our case supports the recently proposed notion of adding a fifth variant to the traditional dual LAD classification system.

10.
Can Assoc Radiol J ; 63(3): 183-91, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22054699

RESUMEN

PURPOSE: Follow-up study to observe if provincial mean effective radiation dose for head, chest, and abdomen-pelvis (AP) computed tomographies (CTs) remained stable or changed since the initial 2006 survey. METHODS: Data were collected in July 2008 from Saskatchewan's 13 diagnostic CT scanners of 3358 CT examinations. These data included the number of scan phases and projected dose length product (DLP). Technologists compared projected DLP with 2006 reference data before scanning. Projected DLP was converted to effective dose (ED) for each head, chest, and AP CT. The total dose that the patients received with scans of multiple body parts at the same visit also was determined. RESULTS: The mean (± SD) provincial ED was 3.4 ± 1.6 mSv for 1023 head scans (2.7 ± 1.6 mSv in 2006), 9.6 ± 4.8 mSv for 588 chest scans (11.3 ± 8.9 mSv in 2006), and 16.1 ± 9.9 mSv for 983 AP scans (15.5 ± 10.0 mSv in 2006). Single-phase multidetector row CT ED decreased by 31% for chest scans (9.5 ± 3.9 mSv vs 13.7 ± 9.7 mSv in 2006) and 17% for AP scans (13.9 ± 6.0 mSv vs 16.8 ± 10.6 mSv in 2006) and increased by 19% for head scans (3.2 ± 1.2 mSv vs 2.7 ± 1.5 mSv in 2006). The total patient dose was highest (33.8 ± 10.1 mSv) for the 20 patients who received head, neck, chest, and AP scans during a single visit. Because of increased utilisation and the increased CT head dose, Saskatchewan per capital radiation dose from CT increased by 21% between 2006 and 2008 (1.14 vs 1.38 mSv/person per year). CONCLUSION: Significant dose and variation reduction was seen for single-phase CT chest and AP examinations between 2006 and 2008, whereas CT head dose increased over the same interval. These changes, combined with increased utilisation, resulted in per capita increase in radiation dose from CT between the 2 studies.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X , Distribución de Chi-Cuadrado , Femenino , Estudios de Seguimiento , Cabeza/diagnóstico por imagen , Humanos , Masculino , Pelvis/diagnóstico por imagen , Radiografía Abdominal , Radiografía Torácica , Saskatchewan
11.
Can Respir J ; 18(5): e73-6, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21969934

RESUMEN

Pulmonary function tests in patients with idiopathic pulmonary fibrosis characteristically show a restrictive pattern including small lung volumes and increased expiratory flow rates resulting from a reduction in pulmonary compliance due to diffuse fibrosis. Conversely, an obstructive pattern with hyperinflation results in emphysema by loss of elastic recoil, expiratory collapse of the peripheral airways and air trapping. When the diseases coexist, pulmonary volumes are compensated, and a smaller than expected reduction or even normal lung volumes can be found. The present report describes 10 patients with progressive breathlessness, three of whom experienced severe limitation in their quality of life. All patients showed lung interstitial involvement and emphysema on computed tomography scan of the chest. The 10 patients showed normal spirometry and lung volumes with severe compromise of gas exchange. Normal lung volumes do not exclude diagnosis of idiopathic pulmonary fibrosis in patients with concomitant emphysema. The relatively preserved lung volumes may underestimate the severity of idiopathic pulmonary fibrosis and attenuate its effects on lung function parameters.


Asunto(s)
Fibrosis Pulmonar Idiopática/fisiopatología , Pulmón/patología , Enfisema Pulmonar/patología , Enfisema Pulmonar/fisiopatología , Comorbilidad , Flujo Espiratorio Forzado , Humanos , Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Fibrosis Pulmonar Idiopática/epidemiología , Enfermedades Pulmonares Intersticiales/diagnóstico por imagen , Enfermedades Pulmonares Intersticiales/fisiopatología , Mediciones del Volumen Pulmonar , Masculino , Persona de Mediana Edad , Tamaño de los Órganos , Enfisema Pulmonar/diagnóstico por imagen , Enfisema Pulmonar/epidemiología , Intercambio Gaseoso Pulmonar , Calidad de Vida , Radiografía
13.
Can Respir J ; 17(6): 269-74, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-21165348

RESUMEN

A large kindred of familial pulmonary fibrosis is reported. Six members from the first two generations of this particular kindred were described more than 40 years previously; six more individuals from the third and fourth generations have also been evaluated. The proband, now 23 years of age, has mild disease; the other 11 documented affected family members all died from their disease at an average age of 37 years (range 25 to 50 years). The pathology was that of usual interstitial pneumonia, as is typical in idiopathic pulmonary fibrosis. However, the initial radiographic pattern in many of these individuals was upper lobe and nodular and, along with the young age, was atypical for idiopathic pulmonary fibrosis. Several genetic abnormalities have been associated with familial pulmonary fibrosis. The present study examined the genes coding for surfactant protein-C, ATPbinding cassette protein A3 and telomerase, and found no abnormalities.


Asunto(s)
Transportadoras de Casetes de Unión a ATP/genética , Fibrosis Pulmonar Idiopática/genética , Proteína C Asociada a Surfactante Pulmonar/genética , Telomerasa/genética , Adulto , Femenino , Humanos , Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Fibrosis Pulmonar Idiopática/patología , Masculino , Persona de Mediana Edad , Linaje , Radiografía , Adulto Joven
16.
Rev Neurol Dis ; 6(3): E97, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19898275

RESUMEN

A 38-year-old man presented with an abrupt onset of occipital and neck pain, radiating to both shoulders. The pain was accompanied by inability to lift his arms against gravity (the "man-in-the-barrel" syndrome). These symptoms were associated with bilateral hand paresthesias, right-sided throbbing headache, vertigo, nausea, and vomiting. All symptoms resolved within 30 minutes, but arm weakness recurred. The differential diagnosis and historical origins of the "man-in-the-barrel" syndrome are reviewed.


Asunto(s)
Brazo/fisiopatología , Trastornos Migrañosos/complicaciones , Debilidad Muscular/etiología , Dolor de Cuello/etiología , Dolor de Cuello/fisiopatología , Parestesia/etiología , Adulto , Brazo/inervación , Diagnóstico Diferencial , Pruebas Diagnósticas de Rutina , Traumatismos Cerrados de la Cabeza/complicaciones , Humanos , Masculino , Trastornos Migrañosos/fisiopatología , Debilidad Muscular/fisiopatología , Examen Neurológico , Parestesia/fisiopatología
17.
Can Assoc Radiol J ; 60(2): 71-8, 2009 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-19433037

RESUMEN

OBJECTIVE: To calculate the effective dose from diagnostic computed tomography (CT) scans in Saskatchewan, Canada, and compare with other reported dose levels. METHODS: Data from CT scans were collected from 12 scanners in 7 cities across Saskatchewan. The patient age, scan type, and selected technique parameters including the dose length product and the volume computed tomography dose index were collected for a 2-week period. This information then was used to calculate effective doses patients are exposed to during CT examinations. Data from 2,061 clinically indicated CT examinations were collected, and of them 1,690 were eligible for analysis. Every examination during a 2-week period was recorded without selection. RESULTS: The average provincial estimated patient dose was as follows: head, 2.7 mSv (638 scans; standard deviation [SD], +/-1.6); chest, 11.3 mSv (376 scans; SD, +/-8.9); abdomen-pelvis, 15.5 mSv (578 scans; SD, +/-10.0); abdomen, 11.7 mSv (80 scans; SD, +/-11.48), and pelvis, 8.6 mSv (18 scans; SD, +/-6.04). Significant variation in dose between the CT scanners was observed (P = .049 for head, P = .001 for chest, and P = .034 for abdomen-pelvis). CONCLUSIONS: Overall, the estimated dose from diagnostic CT examinations was similar to other previously published Canadian data from British Columbia. This dose varied slightly from some other published standards, including being higher than those found in a review conducted in the United Kingdom in 2003.


Asunto(s)
Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Cabeza/diagnóstico por imagen , Humanos , Lactante , Recién Nacido , Pulmón/diagnóstico por imagen , Persona de Mediana Edad , Pelvis/diagnóstico por imagen , Radiografía Abdominal/métodos , Radiografía Abdominal/estadística & datos numéricos , Saskatchewan , Adulto Joven
20.
AJR Am J Roentgenol ; 184(3): 742-5, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15728591

RESUMEN

OBJECTIVE: In our department, most high-resolution CT (HRCT) scans of the lungs are performed in conjunction with a standard helical examination to assess the entire chest. This requires scanning the patient twice. The goal of this study was to determine if the radiation dose could be decreased by performing a single combination helical scan of the chest from which both 5-mm standard and 1.25-mm HRCT images could be obtained. CONCLUSION: Because the total measured radiation dose is 32% greater from a single combination helical HRCT scan of the chest versus separate standard helical plus axial HRCT scans, helical HRCT is not a clinically advisable technique.


Asunto(s)
Radiografía Torácica/efectos adversos , Radiografía Torácica/métodos , Tomografía Computarizada Espiral/efectos adversos , Tomografía Computarizada Espiral/métodos , Fantasmas de Imagen , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA