Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 323-333, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38294107

RESUMEN

PURPOSE: The primary purpose of the study was to use pre-revision total knee arthroplasty (TKA) computer-tomography (CT)-images to analyse typical tibial bone defects and create a new schematic three-dimensional (3D)-classification system. The secondary purpose was to investigate the association between defect size and implant selection at the time of revision surgery. METHODS: Eighty-four patients with preoperative CT-scans underwent revision of a primary TKA. CT-image segmentation with the 3D-Slicer Software was performed retrospectively, and a new three-dimensional classification system was used to grade tibial bone defects. The location of tibial bone defects was recorded for all cases. Volumetric 3D bone defect measurements were used to investigate the association between the bone defect volume, the indication for rTKA, and the use of modular revision components. The t-test, the Mann-Whitney-U test, and the Fisher's exact-test were used for group comparisons, and the Kruskal-Wallis test was used for multiple group comparisons. RESULTS: The most common anatomic regions for both contained and uncontained tibial bone defects were the anteromedial epiphysis (N = 50; mean epiphyseal-defect: 5.9 cm³) and metaphysis (N = 15; mean metaphyseal-defect: 9.6 cm³). A significant association was found between patients with preoperative metaphyseal defects (N = 22) and the use of tibial augments (N = 7) (p = 0.04). The use of cones/sleeves was associated with a significantly increased 3D-CT volume of the preoperative metaphyseal bone defects (p = 0.04). Patients with osteoporosis had significantly larger volumetric defects in the metaphysis (p = 0.01). CONCLUSION: Our results emphasise the importance of considering the three-dimensional nature of tibial defects in rTKA. The findings suggest that an understanding of the volume of the defect size through CT imaging can predict the need for augments and cones/sleeves and, especially in patients with osteoporosis can help the surgeon identify larger metaphyseal defects and ensure optimal metaphyseal fixation through appropriate implant selection. LEVEL OF EVIDENCE: Level III, retrospective cohort study.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Osteoporosis , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Diseño de Prótesis , Tibia/diagnóstico por imagen , Tibia/cirugía , Reoperación/métodos , Osteoporosis/etiología , Osteoporosis/cirugía , Articulación de la Rodilla/diagnóstico por imagen , Articulación de la Rodilla/cirugía
2.
J Arthroplasty ; 39(8S1): S237-S243, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38401612

RESUMEN

BACKGROUND: Chronic extensor mechanism disruption after total knee arthroplasty (TKA) is a rare but challenging condition. There are several surgical approaches for quadriceps tendon repairs. In this report, we present a modified surgical technique for quadriceps tendon repair in chronic extensor mechanism disruption without the use of allografts or mesh augmentation. METHODS: We retrospectively reviewed 12 consecutive cases of chronic extensor mechanism with complete quadriceps tendon ruptures after TKA that underwent the advancement and imbrication technique. Patient outcomes were evaluated using the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement, the range of motion and extensor lag measurements, and standardized lateral radiographs were reviewed for Insall-Salvati-Ratio preoperatively and at their most recent follow-up visit. RESULTS: There were 12 knees from patients who had a mean age of 72 years (range, 62 to 81) and were evaluated with a mean follow-up of 15.9 months (range, 11.4 to 50.9). The extensor lag significantly improved from 40.8 ± 31.9° (range, 10 to 90°) to 2.9 ± 6.9° (P = .014), the Insall-Salvati-Ratio significantly changed from 0.87 to 1.07 (P = .010), and the Knee Injury and Osteoarthritis Outcome Score for Joint Replacement showed a significant difference: a raw score of 13.0 ± 5.8 versus 8.7 ± 5.6 (P = .002) and an interval score of 54.1 ± 14.0 versus 66.2 ± 15.6 (P = .001). CONCLUSIONS: Reconstruction of extensor mechanism in chronic quadriceps tendon ruptures after TKA with the advancement and imbrication technique showed excellent functional outcomes with no extensor lag and excellent restoration of motion. This technique can be combined with TKA revision surgery or used on its own. To ensure successful outcomes, the authors favor rigid immobilization for 12 weeks before starting mobilization.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Músculo Cuádriceps , Rango del Movimiento Articular , Traumatismos de los Tendones , Humanos , Anciano , Masculino , Femenino , Artroplastia de Reemplazo de Rodilla/métodos , Estudios Retrospectivos , Traumatismos de los Tendones/cirugía , Músculo Cuádriceps/cirugía , Persona de Mediana Edad , Anciano de 80 o más Años , Rotura/cirugía , Resultado del Tratamiento , Procedimientos de Cirugía Plástica/métodos , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología
3.
Artículo en Inglés | MEDLINE | ID: mdl-38662001

RESUMEN

INTRODUCTION: Options for soft tissue coverage in revision total knee arthroplasty (rTKA) range from primary wound closure to complex muscle flap reconstructions. The purpose of this study was to investigate the institutional experience of wound coverage options for complex soft tissue defects in rTKA. MATERIALS AND METHODS: 77 patients undergoing rTKA with complex wound closure by a single plastic surgeon were retrospectively reviewed. The average follow-up was 30.1 months. In 18 (23.4%) patients, an intraoperative decision for primary closure was made. Fifty-nine patients (76.6%) received either a local fasciocutaneous (N = 18), a medial gastrocnemius (N = 37), a free latissimus dorsi (N = 3) or a lateral gastrocnemius flap (N = 1). Revision-free survival and complication rates were assessed and risk factors were analyzed with Cox-regression analysis. RESULTS: Medial gastrocnemius flaps had significant lower cumulative revision-free survival rates than local fasciocutaneous flaps (P = 0.021) and primary closures (P < 0.001) (42.5% vs. 71.5% vs. 100%,respectively). Comparing the most common complex closure procedures medial gastrocnemius flaps had the highest rate of prolonged wound healing (29.7%) and infection/reinfection (40.5%). Infection-associated flap procedures had significant lower cumulative revision-free survival rates (30.5%) than non-infection associated flap procedures (62.8%,P = 0.047). A history of more than two prior surgeries (HR = 6.11,P < 0.001) and an age ≥ 65 years (HR = 0.30,P = 0.018) significantly increased the risk of revision. CONCLUSIONS: The results of this study indicate that primary closure -if possible- should be preferred to early proactive muscle flap coverage. Even in the hands of an experienced plastic surgeon muscle flaps have high revision and complication rates. The study highlights the need to clarify flap indications and to investigate alternative approaches.

4.
Arch Orthop Trauma Surg ; 144(4): 1703-1712, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38488903

RESUMEN

INTRODUCTION: There are two variants regarding the low location of the patella in relation to the tibio-femoral joint line: patella baja (PB) and pseudo-patella baja (PPB). The purpose of this study is to investigate the incidence of PB and PPB in a cohort of patients that underwent revision total knee arthroplasty (rTKA) for aseptic reasons and describe any differences in each group's ROM. METHODS: This retrospective study included 114 patients that underwent aseptic revision TKA surgery between 2017 and 2022. Patients were revised either for stiffness (Group 1) or aseptic loosening/instability (Group 2). The Insall-Salvati ratio (ISR) and Blackburne-Peel ratio (BPR) were used to evaluate the patellar position. ISR < 0.8 defined PB, while cases with ISR ≥ 0.8 and BPI < 0.54 were defined as PPB. ROM was measured and a subanalysis was conducted to investigate the progression of the values of ISR and BPR. RESULTS: 55 patients comprised Group 1, and 59 patients comprised Group 2. Overall, 13 cases (11.4%) had PB before rTKA and 24 (21%) had PB after rTKA. Cases with PPB were 13 (11.4%) before and 34 (29.9%) after rTKA. Group 1 patients presented with more PB before and after rTKA (12.8% vs 10.2% and 27.3% vs 15.2% respectively). However, after rTKA Group 1 patients presented with less PPB (20%) compared to Group 2 (39%) (p = 0.02). In Group 1, patients with PPB after rTKA had less ROM compared to those without PPB [83.2 (± 21.9) vs 102.1 (± 19.9) (p = 0.025)]. The subanalysis (69 patients) showed a statistically significant decrease in ISR before and after rTKA (p = 0.041), and from the native knee to post-rTKA (p = 0.001). There was a statistically significant decrease in BPR before and after rTKA (p = 0.001) and from the native knee to both pre- and post-rTKA (p < 001). CONCLUSION: After undergoing rTKA, the incidences of both patella baja (PB) and pseudo-patella baja (PPB) increased. Stiffness in the knee was associated with a higher incidence of PB, while non-stiffness cases showed a significantly higher incidence of PPB. Patients with stiff knees and PPB after rTKA experienced a significant reduction in range of motion (ROM). Additionally, the study revealed a noteworthy decrease in ISR and BPR with each subsequent surgery. This information is crucial for healthcare providers, as it sheds light on potential risks and outcomes of rTKA, allowing for improved patient management and surgical decision-making. LEVEL OF EVIDENCE: III.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Artropatías , Prótesis de la Rodilla , Humanos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Rótula/cirugía , Incidencia , Estudios Retrospectivos , Articulación de la Rodilla/cirugía , Artropatías/cirugía , Rango del Movimiento Articular , Prótesis de la Rodilla/efectos adversos
5.
Bone Joint J ; 106-B(5): 468-474, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38688505

RESUMEN

Aims: Obtaining solid implant fixation is crucial in revision total knee arthroplasty (rTKA) to avoid aseptic loosening, a major reason for re-revision. This study aims to validate a novel grading system that quantifies implant fixation across three anatomical zones (epiphysis, metaphysis, diaphysis). Methods: Based on pre-, intra-, and postoperative assessments, the novel grading system allocates a quantitative score (0, 0.5, or 1 point) for the quality of fixation achieved in each anatomical zone. The criteria used by the algorithm to assign the score include the bone quality, the size of the bone defect, and the type of fixation used. A consecutive cohort of 245 patients undergoing rTKA from 2012 to 2018 were evaluated using the current novel scoring system and followed prospectively. In addition, 100 first-time revision cases were assessed radiologically from the original cohort and graded by three observers to evaluate the intra- and inter-rater reliability of the novel radiological grading system. Results: At a mean follow-up of 90 months (64 to 130), only two out of 245 cases failed due to aseptic loosening. Intraoperative grading yielded mean scores of 1.87 (95% confidence interval (CI) 1.82 to 1.92) for the femur and 1.96 (95% CI 1.92 to 2.0) for the tibia. Only 3.7% of femoral and 1.7% of tibial reconstructions fell below the 1.5-point threshold, which included the two cases of aseptic loosening. Interobserver reliability for postoperative radiological grading was 0.97 for the femur and 0.85 for the tibia. Conclusion: A minimum score of 1.5 points for each skeletal segment appears to be a reasonable cut-off to define sufficient fixation in rTKA. There were no revisions for aseptic loosening at mid-term follow-up when this fixation threshold was achieved or exceeded. When assessing first-time revisions, this novel grading system has shown excellent intra- and interobserver reliability.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Prótesis de la Rodilla , Falla de Prótesis , Reoperación , Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Femenino , Masculino , Anciano , Persona de Mediana Edad , Anciano de 80 o más Años , Reproducibilidad de los Resultados , Estudios Prospectivos , Fémur/cirugía , Tibia/cirugía , Estudios de Seguimiento
6.
Bone Joint J ; 106-B(3 Supple A): 115-120, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38423098

RESUMEN

Aims: Periprosthetic femoral fracture (PPF) is a major complication following total hip arthroplasty (THA). Uncemented femoral components are widely preferred in primary THA, but are associated with higher PPF risk than cemented components. Collared components have reduced PPF rates following uncemented primary THA compared to collarless components, while maintaining similar prosthetic designs. The purpose of this study was to analyze PPF rate between collarless and collared component designs in a consecutive cohort of posterior approach THAs performed by two high-volume surgeons. Methods: This retrospective series included 1,888 uncemented primary THAs using the posterior approach performed by two surgeons (PKS, JMV) from January 2016 to December 2022. Both surgeons switched from collarless to collared components in mid-2020, which was the only change in surgical practice. Data related to component design, PPF rate, and requirement for revision surgery were collected. A total of 1,123 patients (59.5%) received a collarless femoral component and 765 (40.5%) received a collared component. PPFs were identified using medical records and radiological imaging. Fracture rates between collared and collarless components were analyzed. Power analysis confirmed 80% power of the sample to detect a significant difference in PPF rates, and a Fisher's exact test was performed to determine an association between collared and collarless component use on PPF rates. Results: Overall, 17 PPFs occurred (0.9%). There were 16 fractures out of 1,123 collarless femoral components (1.42%) and one fracture out of 765 collared components (0.13%; p = 0.002). The majority of fractures (n = 14; 82.4%) occurred within 90 days of primary THA. There were ten reoperations for PPF with collarless components (0.89%) and one reoperation with a collared component (0.13%; p = 0.034). Conclusion: Collared femoral components were associated with significant decreases in PPF rate and reoperation rate for PPF compared to collarless components in uncemented primary THA. Future studies should investigate whether new-generation collared components reduce PPF rates with longer-term follow-up.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Fracturas del Fémur , Prótesis de Cadera , Fracturas Periprotésicas , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Fracturas Periprotésicas/etiología , Fracturas Periprotésicas/prevención & control , Fracturas Periprotésicas/cirugía , Estudios Retrospectivos , Diseño de Prótesis , Fracturas del Fémur/etiología , Fracturas del Fémur/prevención & control , Fracturas del Fémur/cirugía
7.
Knee ; 49: 27-35, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38833774

RESUMEN

Extensor mechanism (EM) disruption is a rare but severe complication of total knee arthroplasty (TKA) that can greatly impair function. Treatment options for chronic patella tendon ruptures include primary repair, autograft augmentation, and reconstruction with allograft or synthetic material. Despite various techniques, failures can occur, and options for reconstruction after a failed allograft or mesh are limited, especially if the tibial component is well-fixed and cannot be easily removed, and if there is proximal tibial deficiency from a previous failed EM allograft. This case report presents a novel solution for revision EM reconstruction in a 72y.o. female patient with a history of multiple EM failures using an off-label Trabecular Metal Cone-Mesh-Cone (TM CMC) clamshell construct. The surgical procedure involved the removal of a non-viable allograft from the knee joint and the creation of a custom trabecular metal (TM) clamshell construct with a Marlex mesh graft in between the two TM implants. The customized TM cone was designed to cover the deficient anterior tibia and wrap around the ingrown TM cone. The Marlex mesh was cemented between the existing implant and the customized TM cone, and the construct was secured in place with two cancellous screws. The mesh was tunneled between soft tissue to prevent contact with the implant and rotated scar tissue was interposed to prevent abrasion of the mesh on the implant surfaces. The patient tolerated the procedure well and no complications were noted postoperatively. At a follow-up 12 months after the operation the patient remains satisfied with the result.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Reoperación , Mallas Quirúrgicas , Tibia , Humanos , Femenino , Artroplastia de Reemplazo de Rodilla/métodos , Tibia/cirugía , Anciano , Tantalio , Prótesis de la Rodilla , Falla de Prótesis , Traumatismos de los Tendones/cirugía , Procedimientos de Cirugía Plástica/métodos
8.
Arthroplast Today ; 28: 101398, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38993836

RESUMEN

Background: Hip dysplasia is considered one of the leading etiologies contributing to hip degeneration and the eventual need for total hip arthroplasty (THA). We validated a deep learning (DL) algorithm to measure angles relevant to hip dysplasia and applied this algorithm to determine the prevalence of dysplasia in a large population based on incremental radiographic cutoffs. Methods: Patients from the Osteoarthritis Initiative with anteroposterior pelvis radiographs and without previous THAs were included. A DL algorithm automated 3 angles associated with hip dysplasia: modified lateral center-edge angle (LCEA), Tönnis angle, and modified Sharp angle. The algorithm was validated against manual measurements, and all angles were measured in a cohort of 3869 patients (61.2 ± 9.2 years, 57.1% female). The percentile distributions and prevalence of dysplastic hips were analyzed using each angle. Results: The algorithm had no significant difference (P > .05) in measurements (paired difference: 0.3°-0.7°) against readers and had excellent agreement for dysplasia classification (kappa = 0.78-0.88). In 140 minutes, 23,214 measurements were automated for 3869 patients. LCEA and Sharp angles were higher and the Tönnis angle was lower (P < .01) in females. The dysplastic hip prevalence varied from 2.5% to 20% utilizing the following cutoffs: 17.3°-25.5° (LCEA), 9.4°-15.6° (Tönnis), and 41.3°-45.9° (Sharp). Conclusions: A DL algorithm was developed to measure and classify hips with mild hip dysplasia. The reported prevalence of dysplasia in a large patient cohort was dependent on both the measurement and threshold, with 12.4% of patients having dysplasia radiographic indices indicative of higher THA risk.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA