Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Neuroradiology ; 66(6): 1013-1020, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38563963

RESUMEN

PURPOSE: The aim of this registry was to assess technical success, procedural safety and mid- to long-term follow-up results of the Silk Vista "Mama" (SVM) flow diverter (BALT, Montmorency, France) for the treatment of proximal intracranial aneurysms. METHODS: Between August 2020 and March 2022, data from nine Italian neurovascular centres were collected. Data included patients' clinical presentation, aneurysms' size, location and status, technical details, overall complications and mid- to long-term angiographic follow-up. RESULTS: Forty-eight aneurysms in 48 patients were treated using the SVM. Most aneurysms were small (≤ 10 mm: no. 29, 60%) and unruptured (no. 31, 65%); 13 aneurysms were recurrent after coiling or clipping. 37/48 aneurysms involved the internal carotid artery (77%). Optimal opening and complete wall apposition of the device were achieved in 46 out of 48 cases (96%). Four intra- or periprocedural complications occurred (two thrombotic complications successfully resolved, one cerebellar ischemia, one perirenal hematoma), without new neurological deficit. No significant intra-stent stenosis or stent displacement was observed during follow-up. No FD-related morbidity nor mortality was reported. At midterm (6-12 months) to long-term (> 12 months) follow-up, complete aneurysm occlusion (OKM D) was achieved in 76% of cases. Eighty-eight percent of patients had complete aneurysm occlusion or entry remnant (OKM D + C). CONCLUSIONS: Our experience suggests that the new generation of low-profile SVM flow diverter for the treatment of proximal intracranial aneurysms is safe and effective, with low rates of intraprocedural complications and acceptable mid- to long-term occlusion rate.


Asunto(s)
Embolización Terapéutica , Aneurisma Intracraneal , Sistema de Registros , Stents , Humanos , Aneurisma Intracraneal/terapia , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Masculino , Femenino , Embolización Terapéutica/métodos , Embolización Terapéutica/instrumentación , Persona de Mediana Edad , Anciano , Estudios de Seguimiento , Círculo Arterial Cerebral/diagnóstico por imagen , Adulto , Angiografía Cerebral , Italia , Resultado del Tratamiento
2.
Radiol Case Rep ; 19(2): 665-670, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38111559

RESUMEN

This report describes the case of a 56-year-old woman who presented at the emergency room with a 3-week history of severe, intermittent abdominal pain. A CT scan revealed colo-colic intussusception caused by a large, substenosing mass with predominant adipose density. Subsequent endoscopic examination with biopsy revealed a necrotic tissue covering the mass, without definitive histological characterization. A second biopsy led to the extremely rare diagnosis of colo-colic lipoma. While intussusception is rare in adults, it's important to consider it as a differential diagnosis, especially when presenting with abdominal pain and signs of bowel obstruction. Timely diagnosis and appropriate treatment are essential to prevent complications.

3.
Healthcare (Basel) ; 12(2)2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38255124

RESUMEN

Historically, non-cancer diseases have not been considered a health risk following low-dose exposure to ionizing radiation. However, it is now well known that high-dose ionizing radiation causes cardiovascular disease, and emerging epidemiological evidence suggests an excess risk of non-cancer diseases even following exposure to lower doses of ionizing radiation than previously thought. In fact, the evidence is strongest for cardiovascular disease (CVD). The aim of this review was to report the most representative studies and data on the risk of CVD from low-dose radiation in people with occupational exposure. We reported the results of 27 articles selected from a database search of 1151 studies. The results show a complex evidence landscape on the relationship between radiation exposure and cardiovascular disease. In general, published papers show a positive association between ionizing radiation exposure and dermal microcirculation damage, ischemic heart disease, and cerebrovascular disease. Overall, they highlight the need for comprehensive and detailed research to clarify this relationship. Due to limited statistical power, the dose-risk relationship below 0.5 Gy is inconclusive, but if this relationship is found to have no threshold, it could have a significant impact on current estimates of health risks at low doses.

4.
Neuroradiol J ; : 19714009241242650, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38561313

RESUMEN

OBJECTIVES: Few experiences on vertebrobasilar occlusion over underlying intracranial atherosclerotic disease have been reported in literature and the optimal strategy on how to perform a mechanical thrombectomy is unclear. The aim of this paper is to bring our experience based on patients admitted with acute vertebrobasilar occlusion with underlying atheromatous lesions. MATERIALS AND METHODS: Several data were collected from August 2009 to October 2022 including clinical history, pre- and post-treatment neurological objectivity, diagnostic images and angiographic procedural images, and clinical outcome at 6 months. We selected 13 patients from August 2009 to October 2022, 12 men and 1 woman, aged 40 to 82 years (mean age, 62.6 years). RESULTS: Mechanical thrombectomy with a thromboaspiration was performed in all patients as beginning of the procedure. In three patients, the procedures resulted in excellent angiographic result and clinical outcome, while in three patients, we observed a failure of the procedural and clinical outcome. For residual intracranial stenosis in three patients, an angioplasty was performed obtaining an ischemic area related to the posterior circulation. In four patients, a stent was placed, in three patients, we obtained a good clinical outcome with a mRS between 0 and 2, while one treatment resulted in death, probably due to a late endovascular treatment. CONCLUSIONS: Endovascular treatment with stent deployment appears to result in an excellent outcome in patients with occlusion of the vertebrobasilar circulation in cases of occlusion on atheromatic plaque. The degree of residual stenosis after thrombospiration can significantly affect subsequent type of treatment.

5.
Magn Reson Imaging ; 105: 46-56, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37939968

RESUMEN

OBJECTIVE: Gadolinium-based contrast agent needs time to leak into the extravascular-extracellular space, leak back into the vascular space, and reach an equilibrium state. For this reason, acquisition times of <10 min may cause inaccurate estimation of pharmacokinetic parameters. Since no studies have been conducted on the influence of long scan times on DCE-MRI parameters in brain tumors, the aim of this study is to investigate the variation of DCE-MRI-derived kinetic parameters as a function of acquisition time, from 5 to 10 min in brain tumors. MATERIALS AND METHODS: Fifty-two patients with histologically confirmed brain tumors were enrolled in this retrospective study, and examination at 3 T, DCE-MRI, with scan duration of 10 min, was used for retrospective generation of 6 sets of quantitative DCE-MRI maps (Ktrans, Ve and Kep) from 5 to 10 min. Features were extracted from the DCE-MRI maps in contrast enhancement (CE) volumes. Kruskal-Wallis with post-hoc correction and coefficient of variation (CoV) were used as statistical test to compare DCE-MRI maps obtained from 6 data sets. SIGNIFICANCE: p < 0.05. RESULTS: No differences in Ktrans features in CE volumes between different scan durations. Ve, Kep features in CE volumes were influenced by different data length. The highest number of significantly different Ve and Kep features in CE volumes were between 5 min and 10 min (p < 0.013), 5 min and 9 min (p < 0.044), 6 min and 10 min (p < 0.040). CoV of Kep was reduced from 5 min to 10 min, going from highly variable (CoV = 0.70) to mildly variable (CoV = 0.42). CONCLUSION: Kep and Ve were time-dependent in brain tumors, so a longer scan time is needed to obtain reliable parameter values. Ktrans was found to be time-independent, as it remains the same in all 6 acquisition times and is the only reliable parameter with short acquisition times.


Asunto(s)
Neoplasias Encefálicas , Imagen por Resonancia Magnética , Humanos , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Medios de Contraste/farmacocinética , Neoplasias Encefálicas/diagnóstico por imagen , Encéfalo/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA