Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Molecules ; 27(16)2022 Aug 17.
Artículo en Inglés | MEDLINE | ID: mdl-36014494

RESUMEN

Breath analysis provides great potential as a fast and non-invasive diagnostic tool for several diseases. Straight-chain aliphatic aldehydes were repeatedly detected in the breath of patients suffering from lung diseases using a variety of methods, such as mass spectrometry, ion mobility spectrometry, or electro-chemical sensors. Several studies found increased concentrations of exhaled aldehydes in patients suffering from lung cancer, inflammatory and infectious lung diseases, and mechanical lung injury. This article reviews the origin of exhaled straight-chain aliphatic aldehydes, available detection methods, and studies that found increased aldehyde exhalation in lung diseases.


Asunto(s)
Neoplasias Pulmonares , Compuestos Orgánicos Volátiles , Aldehídos/análisis , Biomarcadores/análisis , Pruebas Respiratorias/métodos , Espiración , Humanos , Neoplasias Pulmonares/diagnóstico
2.
Anesth Analg ; 133(1): 263-273, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-33929393

RESUMEN

BACKGROUND: Mechanical ventilation injures lungs, but there are currently no reliable methods for detecting early injury. We therefore evaluated whether exhaled pentanal, a lipid peroxidation product, might be a useful breath biomarker for stretch-induced lung injury in rats. METHODS: A total of 150 male Sprague-Dawley rats were investigated in 2 substudies. The first randomly assigned 75 rats to 7 hours of mechanical ventilation at tidal volumes of 6, 8, 12, 16, and 20 mL·kg-1. The second included 75 rats. A reference group was ventilated at a tidal volume of 6 mL·kg-1 for 10 hours 4 interventional groups were ventilated at a tidal volume of 6 mL·kg-1 for 1 hour, and then for 0.5, 1, 2, or 3 hours at a tidal volume of 16 mL.kg-1 before returning to a tidal volume of 6 mL·kg-1 for additional 6 hours. Exhaled pentanal was monitored by multicapillary column-ion mobility spectrometry. The first substudy included cytokine and leukocyte measurements in blood and bronchoalveolar fluid, histological assessment of the proportion of alveolar space, and measurements of myeloperoxidase activity in lung tissue. The second substudy included measurements of pentanal in arterial blood plasma, cytokine and leukocyte concentrations in bronchoalveolar fluid, and cleaved caspase 3 in lung tissue. RESULTS: Exhaled pentanal concentrations increased by only 0.5 ppb·h-1 (95% confidence interval [CI], 0.3-0.6) when rats were ventilated at 6 mL·kg-1. In contrast, exhaled pentanal concentrations increased substantially and roughly linearly at higher tidal volumes, up to 3.1 ppb·h-1 (95% CI, 2.3-3.8) at tidal volumes of 20 mL·kg-1. Exhaled pentanal increased at average rates between 1.0 ppb·h-1 (95% CI, 0.3-1.7) and 2.5 ppb·h-1 (95% CI, 1.4-3.6) after the onset of 16 mL·kg-1 tidal volumes and decreased rapidly by a median of 2 ppb (interquartile range [IQR], 0.9-3.2), corresponding to a 38% (IQR, 31-43) reduction when tidal volume returned to 6 mL·kg-1. Tidal volume, inspiratory pressure, and mechanical power were positively associated with pentanal exhalation. Exhaled and plasma pentanal were uncorrelated. Alveolar space decreased and inflammatory markers in bronchoalveolar lavage fluid increased in animals ventilated at high tidal volumes. Short, intermittent ventilation at high tidal volumes for up to 3 hours increased neither inflammatory markers in bronchoalveolar fluid nor the proportion of cleaved caspase 3 in lung tissue. CONCLUSIONS: Exhaled pentanal is a potential biomarker for early detection of ventilator-induced lung injury in rats.


Asunto(s)
Aldehídos/metabolismo , Espiración/fisiología , Respiración Artificial/efectos adversos , Lesión Pulmonar Inducida por Ventilación Mecánica/metabolismo , Aldehídos/análisis , Anestésicos por Inhalación/administración & dosificación , Animales , Biomarcadores/metabolismo , Líquido del Lavado Bronquioalveolar/química , Espiración/efectos de los fármacos , Masculino , Ratas , Ratas Sprague-Dawley , Sevoflurano/administración & dosificación , Volumen de Ventilación Pulmonar/efectos de los fármacos , Volumen de Ventilación Pulmonar/fisiología , Lesión Pulmonar Inducida por Ventilación Mecánica/etiología
3.
Anesth Analg ; 132(1): 110-118, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32118620

RESUMEN

BACKGROUND: Propofol can be measured in exhaled gas. Exhaled and plasma propofol concentrations correlate well, but the relationship with tissue concentrations remains unknown. We thus evaluated the relationship between exhaled, plasma, and various tissue propofol concentrations. Because the drug acts in the brain, we focused on the relationship between exhaled and brain tissue propofol concentrations. METHODS: Thirty-six male Sprague-Dawley rats were anesthetized with propofol, ketamine, and rocuronium for 6 hours. Animals were randomly assigned to propofol infusions at 20, 40, or 60 mg·kg·h (n = 12 per group). Exhaled propofol concentrations were measured at 15-minute intervals by multicapillary column-ion mobility spectrometry. Arterial blood samples, 110 µL each, were collected 15, 30, and 45 minutes, and 1, 2, 4, and 6 hours after the propofol infusion started. Propofol concentrations were measured in brain, lung, liver, kidney, muscle, and fat tissue after 6 hours. The last exhaled and plasma concentrations were used for linear regression analyses with tissue concentrations. RESULTS: The correlation of exhaled versus plasma concentrations (R = 0.71) was comparable to the correlation of exhaled versus brain tissue concentrations (R = 0.75) at the end of the study. In contrast, correlations between plasma and lung and between lung and exhaled propofol concentrations were poor. Less than a part-per-thousand of propofol was exhaled over 6 hours. CONCLUSIONS: Exhaled propofol concentrations correlate reasonably well with brain tissue and plasma concentrations in rats, and may thus be useful to estimate anesthetic drug effect. The equilibration between plasma propofol and exhaled gas is apparently independent of lung tissue concentration. Only a tiny fraction of administered propofol is eliminated via the lungs, and exhaled quantities thus have negligible influence on plasma concentrations.


Asunto(s)
Anestésicos Intravenosos/metabolismo , Encéfalo/metabolismo , Plasma/metabolismo , Propofol/metabolismo , Anestésicos Intravenosos/administración & dosificación , Animales , Encéfalo/efectos de los fármacos , Pruebas Respiratorias/métodos , Espiración/efectos de los fármacos , Masculino , Plasma/efectos de los fármacos , Propofol/administración & dosificación , Distribución Aleatoria , Ratas , Ratas Sprague-Dawley , Distribución Tisular/efectos de los fármacos , Distribución Tisular/fisiología
4.
Molecules ; 26(9)2021 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-34067078

RESUMEN

High inspired oxygen during mechanical ventilation may influence the exhalation of the previously proposed breath biomarkers pentanal and hexanal, and additionally induce systemic inflammation. We therefore investigated the effect of various concentrations of inspired oxygen on pentanal and hexanal exhalation and serum interleukin concentrations in 30 Sprague Dawley rats mechanically ventilated with 30, 60, or 93% inspired oxygen for 12 h. Pentanal exhalation did not differ as a function of inspired oxygen but increased by an average of 0.4 (95%CI: 0.3; 0.5) ppb per hour, with concentrations doubling from 3.8 (IQR: 2.8; 5.1) ppb at baseline to 7.3 (IQR: 5.0; 10.8) ppb after 12 h. Hexanal exhalation was slightly higher at 93% of inspired oxygen with an average difference of 0.09 (95%CI: 0.002; 0.172) ppb compared to 30%. Serum IL-6 did not differ by inspired oxygen, whereas IL-10 at 60% and 93% of inspired oxygen was greater than with 30%. Both interleukins increased over 12 h of mechanical ventilation at all oxygen concentrations. Mechanical ventilation at high inspired oxygen promotes pulmonary lipid peroxidation and systemic inflammation. However, the response of pentanal and hexanal exhalation varies, with pentanal increasing by mechanical ventilation, whereas hexanal increases by high inspired oxygen concentrations.


Asunto(s)
Aldehídos/farmacología , Espiración/efectos de los fármacos , Oxígeno/farmacología , Respiración Artificial , Animales , Pruebas Respiratorias , Citocinas/sangre , Inflamación/patología , Masculino , Presión Parcial , Ratas Sprague-Dawley
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA