Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Neurosurg Rev ; 47(1): 116, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38483647

RESUMEN

BACKGROUND: The Woven EndoBridge (WEB) devices have been used for treating wide neck bifurcation aneurysms (WNBAs) with several generational enhancements to improve clinical outcomes. The original device dual-layer (WEB DL) was replaced by a single-layer (WEB SL) device in 2013. This study aimed to compare the effectiveness and safety of these devices in managing intracranial aneurysms. METHODS: A multicenter cohort study was conducted, and data from 1,289 patients with intracranial aneurysms treated with either the WEB SL or WEB DL devices were retrospectively analyzed. Propensity score matching was utilized to balance the baseline characteristics between the two groups. Outcomes assessed included immediate occlusion rate, complete occlusion at last follow-up, retreatment rate, device compaction, and aneurysmal rupture. RESULTS: Before propensity score matching, patients treated with the WEB SL had a significantly higher rate of complete occlusion at the last follow-up and a lower rate of retreatment. After matching, there was no significant difference in immediate occlusion rate, retreatment rate, or device compaction between the WEB SL and DL groups. However, the SL group maintained a higher rate of complete occlusion at the final follow-up. Regression analysis showed that SL was associated with higher rates of complete occlusion (OR: 0.19; CI: 0.04 to 0.8, p = 0.029) and lower rates of retreatment (OR: 0.12; CI: 0 to 4.12, p = 0.23). CONCLUSION: The WEB SL and DL devices demonstrated similar performances in immediate occlusion rates and retreatment requirements for intracranial aneurysms. The SL device showed a higher rate of complete occlusion at the final follow-up.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Resultado del Tratamiento , Aneurisma Intracraneal/cirugía , Aneurisma Intracraneal/etiología , Embolización Terapéutica/efectos adversos , Puntaje de Propensión , Estudios Retrospectivos , Estudios de Cohortes , Procedimientos Endovasculares/efectos adversos
2.
Radiology ; 304(2): 372-382, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35438564

RESUMEN

Background The Woven EndoBridge (WEB) device was explicitly designed for wide-neck intracranial bifurcation aneurysms. Small-scale reports have evaluated the off-label use of WEB devices for the treatment of sidewall aneurysms, with promising outcomes. Purpose To compare the angiographic and clinical outcomes of the WEB device for the treatment of sidewall aneurysms compared with the treatment of bifurcation aneurysms. Materials and Methods A retrospective review of the WorldWideWEB Consortium, a synthesis of retrospective databases spanning from January 2011 to June 2021 at 22 academic institutions in North America, South America, and Europe, was performed to identify patients with intracranial aneurysms treated with the WEB device. Characteristics and outcomes were compared between bifurcation and sidewall aneurysms. Propensity score matching (PSM) was used to match by age, pretreatment ordinal modified Rankin Scale score, ruptured aneurysms, location of aneurysm, multiple aneurysms, prior treatment, neck, height, dome width, daughter sac, and incorporated branch. Results A total of 683 intracranial aneurysms were treated using the WEB device in 671 patients (median age, 61 years [IQR, 53-68 years]; male-to-female ratio, 1:2.5). Of those, 572 were bifurcation aneurysms and 111 were sidewall aneurysms. PSM was performed, resulting in 91 bifurcation and sidewall aneurysms pairs. No significant difference was observed in occlusion status at last follow-up, deployment success, or complication rates between the two groups. Conclusion No significantly different outcomes were observed following the off-label use of the Woven EndoBridge, or WEB, device for treatment of sidewall aneurysms compared with bifurcation aneurysms. The correct characterization of the sidewall aneurysm location, neck angle, and size is crucial for successful treatment and lower retreatment rate. © RSNA, 2022 See also the editorial by Hetts in this issue.


Asunto(s)
Aneurisma Roto , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Aneurisma Roto/terapia , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Femenino , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
3.
Neurosurg Rev ; 43(4): 1173-1178, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31332702

RESUMEN

Loss of consciousness (LOC) at presentation with aneurysmal subarachnoid hemorrhage (aSAH) has been associated with early brain injury and poor functional outcome. The impact of LOC on the clinical course after aSAH deserves further exploration. A retrospective analysis of 149 aSAH patients who were prospectively enrolled in the Cerebral Aneurysm Renin Angiotensin Study (CARAS) between 2012 and 2015 was performed. The impact of LOC was analyzed with emphasis on patients presenting in excellent or good neurological condition (Hunt and Hess 1 and 2). A total of 50/149 aSAH patients (33.6%) experienced LOC at presentation. Loss of consciousness was associated with severity of neurological condition upon admission (Hunt and Hess, World Federation of Neurosurgical Societies (WFNS), Glasgow Coma Scale (GCS) grade), hemorrhage burden on initial head CT (Fisher CT grade), acute hydrocephalus, cardiac instability, and nosocomial infection. Of Hunt and Hess grade 1 and 2 patients, 21/84 (25.0%) suffered LOC at presentation. Cardiac instability and nosocomial infection were significantly more frequent in these patients. In multivariable analysis, LOC was the predominant predictor of cardiac instability and nosocomial infection. Loss of consciousness at presentation with aSAH is associated with an increased rate of complications, even in good-grade patients. The presence of LOC may identify good-grade patients at risk for complications such as cardiac instability and nosocomial infection.


Asunto(s)
Hemorragia Subaracnoidea/complicaciones , Inconsciencia/etiología , Adulto , Anciano , Estudios de Cohortes , Infección Hospitalaria/complicaciones , Infección Hospitalaria/epidemiología , Femenino , Estudios de Seguimiento , Escala de Coma de Glasgow , Cardiopatías/complicaciones , Cardiopatías/epidemiología , Humanos , Hidrocefalia/complicaciones , Hidrocefalia/epidemiología , Masculino , Persona de Mediana Edad , Enfermedades del Sistema Nervioso/etiología , Hemorragia Subaracnoidea/epidemiología , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Inconsciencia/epidemiología
4.
Stroke ; 48(4): 1098-1100, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28246277

RESUMEN

BACKGROUND AND PURPOSE: Intraprocedural thrombosis poses a formidable challenge during neuroendovascular procedures because the risks of aggressive thromboembolic treatment must be balanced against the risk of postprocedural hemorrhage. The aim of this study was to identify predictors of ischemic stroke after intraprocedural thrombosis after stent-assisted coiling and pipeline embolization device placement. METHODS: A retrospective analysis of intracranial aneurysms treated with stent-assisted coiling or pipeline embolization device placement between 2007 and 2016 at 4 major academic institutions was performed to identify procedures that were complicated by intraprocedural thrombosis. RESULTS: Intraprocedural thrombosis occurred in 34 (4.6%) procedures. Postprocedural ischemic stroke and hemorrhage occurred in 20.6% (7/34) and 11.8% (4/34) of procedures complicated by intraprocedural thrombosis, respectively. Current smoking was an independent predictor of ischemic stroke. There was no statistically significant difference in the rate of ischemic stroke or postprocedural hemorrhage with the use of abciximab compared with the use of eptifibatide in treatment of intraprocedural thrombosis. CONCLUSIONS: Current protocols for treatment of intraprocedural thrombosis associated with placement of intra-arterial devices were effective in preventing ischemic stroke in ≈80% of cases. Current smoking was the only independent predictor of ischemic stroke.


Asunto(s)
Isquemia Encefálica/etiología , Embolización Terapéutica/métodos , Procedimientos Endovasculares/métodos , Fármacos Hematológicos/uso terapéutico , Aneurisma Intracraneal/terapia , Trombosis Intracraneal , Complicaciones Intraoperatorias , Trombolisis Mecánica/métodos , Evaluación de Resultado en la Atención de Salud/estadística & datos numéricos , Stents , Accidente Cerebrovascular/etiología , Angiografía de Substracción Digital , Anticoagulantes/uso terapéutico , Isquemia Encefálica/epidemiología , Embolización Terapéutica/estadística & datos numéricos , Procedimientos Endovasculares/estadística & datos numéricos , Femenino , Fibrinolíticos/uso terapéutico , Humanos , Aneurisma Intracraneal/epidemiología , Trombosis Intracraneal/complicaciones , Trombosis Intracraneal/diagnóstico por imagen , Trombosis Intracraneal/epidemiología , Trombosis Intracraneal/terapia , Complicaciones Intraoperatorias/diagnóstico por imagen , Complicaciones Intraoperatorias/epidemiología , Complicaciones Intraoperatorias/terapia , Masculino , Trombolisis Mecánica/estadística & datos numéricos , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/uso terapéutico , Estudios Retrospectivos , Accidente Cerebrovascular/epidemiología
5.
Stroke ; 48(5): 1322-1330, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28411263

RESUMEN

BACKGROUND AND PURPOSE: Thromboembolic complications constitute a significant source of morbidity after neurointerventional procedures. Flow diversion using the pipeline embolization device for the treatment of intracranial aneurysms necessitates the use of dual antiplatelet therapy to reduce this risk. The use of platelet function testing before pipeline embolization device placement remains controversial. METHODS: A retrospective review of prospectively maintained databases at 3 academic institutions was performed from the years 2009 to 2016 to identify patients with intracranial aneurysms treated with pipeline embolization device placement. Clinical and radiographic data were analyzed with emphasis on thromboembolic complications and clopidogrel responsiveness. RESULTS: A total of 402 patients underwent 414 pipeline embolization device procedures for the treatment of 465 intracranial aneurysms. Thromboembolic complications were encountered in 9.2% of procedures and were symptomatic in 5.6%. Clopidogrel nonresponders experienced a significantly higher rate of thromboembolic complications compared with clopidogrel responders (17.4% versus 5.6%). This risk was significantly lower in nonresponders who were switched to ticagrelor when compared with patients who remained on clopidogrel (2.7% versus 24.4%). In patients who remained on clopidogrel, the rate of thromboembolic complications was significantly lower in those who received a clopidogrel boost within 24 hours pre-procedure when compared with those who did not (9.8% versus 51.9%). There was no significant difference in the rate of hemorrhagic complications between groups. CONCLUSIONS: Clopidogrel nonresponders experienced a significantly higher rate of thromboembolic complications when compared with clopidogrel responders. However, this risk seems to be mitigated in nonresponders who were switched to ticagrelor or received a clopidogrel boost within 24 hours pre-procedure.


Asunto(s)
Embolización Terapéutica/instrumentación , Aneurisma Intracraneal/terapia , Embolia Intracraneal/prevención & control , Trombosis Intracraneal/prevención & control , Evaluación de Resultado en la Atención de Salud , Inhibidores de Agregación Plaquetaria/farmacología , Pruebas de Función Plaquetaria , Ticlopidina/análogos & derivados , Adenosina/administración & dosificación , Adenosina/análogos & derivados , Adenosina/farmacología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Clopidogrel , Embolización Terapéutica/efectos adversos , Femenino , Humanos , Embolia Intracraneal/etiología , Trombosis Intracraneal/etiología , Masculino , Persona de Mediana Edad , Inhibidores de Agregación Plaquetaria/administración & dosificación , Antagonistas del Receptor Purinérgico P2Y/administración & dosificación , Antagonistas del Receptor Purinérgico P2Y/farmacología , Estudios Retrospectivos , Ticagrelor , Ticlopidina/administración & dosificación , Ticlopidina/farmacología , Adulto Joven
6.
Stroke ; 53(2): e47-e49, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34915737
7.
Nitric Oxide ; 71: 52-56, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29079038

RESUMEN

INTRODUCTION: Cardiac abnormalities are observed frequently after aneurysmal subarachnoid hemorrhage (aSAH). A subset of aSAH patients develops neurogenic cardiomyopathy, likely induced by catecholamine excess. Genetic polymorphisms of the endothelial nitric oxide synthase (eNOS) gene have been linked to decreased nitric oxide (NO) levels, coronary artery spasm, and myocardial infarction. The role of the eNOS single nucleotide polymorphism (SNP) -786 T/C in cardiac instability following aSAH has not been previously investigated. METHODS: From 2012 to 2015, aSAH patients were prospectively enrolled in the Cerebral Aneurysm Renin Angiotensin System (CARAS) study at two academic institutions. Blood samples were used to assess the eNOS SNP -786 T/C rs2070744 through 5'exonuclease (Taqman) genotyping assays. Associations between this polymorphism and cardiac instability following aSAH were analyzed. RESULTS: Multivariable analysis demonstrated a dominant effect of the C allele of eNOS SNP -786 T/C on cardiac instability in patients with aSAH. A lower Glasgow Coma Scale score and a history of ischemic vascular disease were also associated with cardiac instability. Furthermore, cardiac instability independently predicted poor functional outcome upon discharge from the hospital. CONCLUSIONS: The C allele of the eNOS SNP -786 T/C was independently associated with an increased risk for cardiac instability following aSAH. Cardiac instability itself was a risk factor for an unfavorable functional outcome upon discharge from the hospital.


Asunto(s)
Cardiopatías/etiología , Cardiopatías/genética , Óxido Nítrico Sintasa de Tipo III/genética , Polimorfismo Genético/genética , Hemorragia Subaracnoidea/complicaciones , Adulto , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/genética , Femenino , Humanos , Hipotensión/etiología , Hipotensión/genética , Masculino , Persona de Mediana Edad , Infarto del Miocardio/etiología , Infarto del Miocardio/genética
8.
Acta Neurochir (Wien) ; 158(1): 189-95, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26589958

RESUMEN

BACKGROUND: Intracranial hemorrhage (ICH) has been reported in association with sexual activity. A case-series of patients with ICH following sexual activity is presented to further elucidate the role of the physiologic sexual response as a trigger of ICH. METHOD: A retrospective review of the medical record was performed, identifying patients presenting with ICH temporally related to sexual activity. Clinical and radiographic data were collected and reported. RESULTS: Sixteen patients presented with non-traumatic ICH temporally related to sexual activity. Eight (50 %) patients presented with aneurysmal subarachnoid hemorrhage, four (25 %) with angiogram-negative subarachnoid hemorrhage, two (12.5 %) with a ruptured arteriovenous malformation, and two (12.5 %) with an intracerebral basal ganglia hemorrhage. Overall average age was 49.9 (range, 28-74) years. Sexual activity involved male-female intercourse in 14 (87.5 %) patients and masturbation in 2 (12.5 %) patients. CONCLUSIONS: Sexual-activity-related ICH is rare and includes various etiologies. The human sexual response in associated with dramatic increases in arterial blood pressure, which likely underlies the association.


Asunto(s)
Hemorragias Intracraneales/etiología , Conducta Sexual , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
9.
Br J Neurosurg ; 29(6): 865-7, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26312946

RESUMEN

Carotid endarterectomy (CEA) is a common and efficacious surgical procedure for the prevention of ischemic stroke due to atherosclerosis of the internal carotid artery (ICA). A high common carotid artery bifurcation can make CEA technically difficult due to limited carotid artery exposure. A cadaveric study was performed to evaluate the efficacy of nasotracheal intubation for improving access to a high carotid artery bifurcation. Based on this study, nasotracheal intubation does not improve access to a high carotid artery bifurcation as compared with orotracheal intubation.


Asunto(s)
Arterias Carótidas/patología , Arterias Carótidas/cirugía , Endarterectomía Carotidea/métodos , Intubación Intratraqueal/métodos , Aterosclerosis/complicaciones , Aterosclerosis/patología , Isquemia Encefálica/patología , Isquemia Encefálica/cirugía , Cadáver , Arteria Carótida Interna/cirugía , Estenosis Carotídea , Humanos , Accidente Cerebrovascular/patología , Accidente Cerebrovascular/cirugía
10.
J Neurosurg ; 140(4): 1071-1079, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37862717

RESUMEN

OBJECTIVE: The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment. In addition, the authors also sought to determine the predictors of a concomitant stent in aneurysms treated with the WEB device. METHODS: The data for this study were taken from the WorldWideWEB Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups based on treatment: stent-assisted WEB and WEB device alone. The authors compared clinical and radiological outcomes of both groups. Univariable and multivariable binary logistic regression analyses were performed to determine factors that predispose to stent use. RESULTS: The study included 691 intracranial aneurysms (31 with stents and 660 without stents) treated with the WEB device. The adequate occlusion status did not differ between the two groups at the latest follow-up (83.3% vs 85.6%, p = 0.915). Patients who underwent stenting had more thromboembolic (32.3% vs 6.5%, p < 0.001) and procedural (16.1% vs 3.0%, p < 0.001) complications. Aneurysms treated with a concomitant stent had wider necks, greater heights, and lower dome-to-neck ratios. Increasing neck size was the only significant predictor for stent use. CONCLUSIONS: This study demonstrates that there is no difference in the degree of aneurysm occlusion between the two groups; however, complications were more frequent in the stent group. In addition, a wider aneurysm neck predisposes to stent assistance in WEB-treated aneurysms.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Resultado del Tratamiento , Estudios Retrospectivos , Stents
11.
J Neurointerv Surg ; 2024 Jan 18.
Artículo en Inglés | MEDLINE | ID: mdl-38238006

RESUMEN

BACKGROUND: The Woven EndoBridge (WEB) device is frequently used for the treatment of intracranial aneurysms. Postoperative management, including the use of aspirin, varies among clinicians and institutions, but its impact on the outcomes of the WEB has not been thoroughly investigated. METHODS: This was a retrospective, multicenter study involving 30 academic institutions in North America, South America, and Europe. Data from 1492 patients treated with the WEB device were included. Patients were categorized into two groups based on their postoperative use of aspirin (aspirin group: n=1124, non-aspirin group: n=368). Data points included patient demographics, aneurysm characteristics, procedural details, complications, and angiographic and functional outcomes. Propensity score matching (PSM) was applied to balance variables between the two groups. RESULTS: Prior to PSM, the aspirin group exhibited significantly higher rates of modified Rankin scale (mRS) mRS 0-1 and mRS 0-2 (89.8% vs 73.4% and 94.1% vs 79.8%, p<0.001), lower rates of mortality (1.6% vs 8.6%, p<0.001), and higher major compaction rates (13.4% vs 7%, p<0.001). Post-PSM, the aspirin group showed significantly higher rates of retreatment (p=0.026) and major compaction (p=0.037) while maintaining its higher rates of good functional outcomes and lower mortality rates. In the multivariable regression, aspirin was associated with higher rates of mRS 0-1 (OR 2.166; 95% CI 1.16 to 4, p=0.016) and mRS 0-2 (OR 2.817; 95% CI 1.36 to 5.88, p=0.005) and lower rates of mortality (OR 0.228; 95% CI 0.06 to 0.83, p=0.025). However, it was associated with higher rates of retreatment (OR 2.471; 95% CI 1.11 to 5.51, p=0.027). CONCLUSIONS: Aspirin use post-WEB treatment may lead to better functional outcomes and lower mortality but with higher retreatment rates. These insights are crucial for postoperative management after WEB procedures, but further studies are necessary for validation.

12.
J Neurosurg ; : 1-8, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38701528

RESUMEN

OBJECTIVE: This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS: A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS: The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19-0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25-0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38-10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26-8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04-0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48-230, p = 0.024). CONCLUSIONS: The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.

13.
J Neurointerv Surg ; 15(6): 558-565, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35483912

RESUMEN

BACKGROUND: The Woven EndoBridge (WEB) device has Food and Drug Administration approval for treatment of wide-necked intracranial bifurcation aneurysms. The WEB device has been shown to result in adequate occlusion in bifurcation aneurysms overall, but its usefulness in the individual bifurcation locations has been evaluated separately only in few case series, which were limited by small sample sizes. OBJECTIVE: To compare angiographic and clinical outcomes after treatment of bifurcation aneurysms at various locations, including anterior communicating artery (AComA), anterior cerebral artery (ACA) bifurcation distal to AComA, basilar tip, internal carotid artery (ICA) bifurcation, and middle cerebral artery (MCA) bifurcation aneurysms using the WEB device. METHODS: A retrospective cohort analysis was conducted at 22 academic institutions worldwide to compare treatment outcomes of patients with intracranial bifurcation aneurysms using the WEB device. Data include patient and aneurysm characteristics, procedural details, angiographic and functional outcomes, and complications. RESULTS: A total of 572 aneurysms were included. MCA (36%), AComA (35.7%), and basilar tip (18.9%) aneurysms were most common. The rate of adequate aneurysm occlusion was significantly higher for basilar tip (91.6%) and ICA bifurcation (96.7%) aneurysms and lower for ACA bifurcation (71.4%) and AComA (80.6%) aneurysms (p=0.04). CONCLUSION: To our knowledge, this is the most extensive study to date that compares the treatment of different intracranial bifurcation aneurysms using the WEB device. Basilar tip and ICA bifurcation aneurysms showed significantly higher rates of aneurysm occlusion than other locations.


Asunto(s)
Enfermedades de las Arterias Carótidas , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Estudios Retrospectivos , Resultado del Tratamiento , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/terapia , Enfermedades de las Arterias Carótidas/terapia
14.
Transl Stroke Res ; 14(4): 455-464, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36066701

RESUMEN

Several studies have shown promising outcomes of the Woven EndoBridge (WEB) device for the treatment of wide-necked intracranial bifurcation aneurysms. This is a multicenter study attempts to explore the changes in trends and treatment outcomes over time for WEB embolization of intracranial aneurysms. The WorldWideWEB consortium is a retrospective multicenter collaboration of data from international centers spanning from January 2011 and June 2021, with no limitations on aneurysm location or rupture status. Both bifurcation and sidewall aneurysms were included. These patients were stratified based on treatment year into five treatment intervals: 2011-2015 (N = 66), 2016-2017 (N = 77), 2018 (N = 66), 2019 (N = 300), and 2020-2021 (N = 173). Patient characteristics and angiographic and clinical outcomes were compared between these time intervals. This study comprised 671 patients (median age 61.4 years; 71.2% female) with 682 intracranial aneurysms. Over time, we observed an increasing tendency to treat patients presenting with ruptured aneurysms and aneurysms with smaller neck, diameter, and dome widths. Furthermore, we observed a trend towards more off-label use of the WEB for sidewall aneurysms and increased adoption of transradial access for WEB deployment. Moreover, the proportion of patients with adequate WEB occlusion immediately and at last follow-up was significantly higher in more recent year cohorts, as well as lower rates of compaction and retreatment. Mortality and complications did not differ over time. This learning curve study suggests improved experience using the WEB for the treatment of intracranial aneurysms and has yielded higher rates of adequate occlusion over time.


Asunto(s)
Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Femenino , Persona de Mediana Edad , Masculino , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Resultado del Tratamiento , Estudios Retrospectivos
15.
J Neurointerv Surg ; 15(9): 844-850, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35868856

RESUMEN

BACKGROUND: The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status. METHODS: Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups: ruptured and unruptured. We compared clinical and radiologic outcomes of both groups. Propensity score matching (PSM) was done to match according to age, gender, bifurcation, location, prior treatment, neck, height, dome width, daughter sac, incorporated branch, pretreatment antiplatelets, and last imaging follow-up. RESULTS: The study included 676 patients with 691 intracranial aneurysms (529 unruptured and 162 ruptured) treated with the WEB device. The PSM analysis had 55 pairs. In both the unmatched (85.8% vs 84.3%, p=0.692) and matched (94.4% vs 83.3%, p=0.066) cohorts there was no significant difference in the adequate occlusion rate at the last follow-up. Likewise, there were no significant differences in both ischemic and hemorrhagic complications between the two groups. There was no documented aneurysm rebleeding after WEB device implantation. CONCLUSION: There was no significant difference in both the radiologic outcomes and complications between unruptured and ruptured aneurysms. Our findings support the feasibility of treatment of ruptured aneurysms with the WEB device.


Asunto(s)
Aneurisma Roto , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Intracraneal , Humanos , Resultado del Tratamiento , Procedimientos Endovasculares/métodos , Estudios Retrospectivos , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/cirugía , Aneurisma Intracraneal/diagnóstico por imagen , Aneurisma Intracraneal/cirugía , Embolización Terapéutica/métodos
16.
Transl Stroke Res ; 2023 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-37165289

RESUMEN

The Woven EndoBridge (WEB) device has been widely used to treat intracranial wide neck bifurcation aneurysms. Initial studies have demonstrated that approximately 90% of patients have same or improved long-term aneurysm occlusion after the initial 6-month follow up. The aim of this study is to assess the long-term follow-up in aneurysms that have achieved complete occlusion at 6 months. We also compared the predictive value of different imaging modalities used. This is an analysis of a prospectively maintained database across 13 academic institutions. We included patients with previously untreated cerebral aneurysms embolized using the WEB device who achieved complete occlusion at first follow-up and had available long-term follow-up. A total of 95 patients with a mean age of 61.6 ± 11.9 years were studied. The mean neck diameter and height were 3.9 ± 1.3 mm and 6.0 ± 1.8 mm, respectively. The mean time to first and last follow-up was 5.4 ± 1.8 and 14.1 ± 12.9 months, respectively. Out of all the aneurysms that were completely occluded at 6 months, 84 (90.3%) showed complete occlusion at the final follow-up, and 11(11.5%) patients did not achieve complete occlusion. The positive predictive value (PPV) of complete occlusion at first follow was 88.4%. Importantly, this did not differ between digital subtraction angiography (DSA), magnetic resonance angiography (MRA), or computed tomography angiography (CTA). This study underlines the importance of repeat imaging in patients treated with the WEB device even if complete occlusion is achieved short term. Follow-up can be performed using DSA, MRA or CTA with no difference in positive predictive value.

17.
J Neurosurg ; : 1-8, 2022 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-35120326

RESUMEN

OBJECTIVE: Transradial access (TRA) is commonly utilized in neurointerventional procedures. This study compared the technical and clinical outcomes of the use of TRA versus those of transfemoral access (TFA) for intracranial aneurysm embolization with the Woven EndoBridge (WEB) device. METHODS: This is a secondary analysis of the Worldwide WEB Consortium, which comprises multicenter data related to adult patients with intracranial aneurysms who were managed with the WEB device. These aneurysms were categorized into two groups: those who were treated with TRA or TFA. Patient and aneurysm characteristics and technical and clinical outcomes were compared between groups. Propensity score matching (PSM) was used to match groups according to the following baseline characteristics: age, sex, subarachnoid hemorrhage, aneurysm location, bifurcation aneurysm, aneurysm with incorporated branch, neck width, aspect ratio, dome width, and elapsed time since the last follow-up imaging evaluation. RESULTS: This study included 682 intracranial aneurysms (median [interquartile range] age 61.3 [53.0-68.0] years), of which 561 were treated with TFA and 121 with TRA. PSM resulted in 65 matched pairs. After PSM, both groups had similar characteristics, angiographic and functional outcomes, and rates of retreatment, thromboembolic and hemorrhagic complications, and death. TFA was associated with longer procedure length (median 96.5 minutes vs 72.0 minutes, p = 0.006) and fluoroscopy time (28.2 minutes vs 24.8 minutes, p = 0.037) as compared with TRA. On the other hand, deployment issues were more common in those treated with TRA, but none resulted in permanent complications. CONCLUSIONS: TRA has comparable outcomes, with shorter procedure and fluoroscopy time, to TFA for aneurysm embolization with the WEB device.

18.
Adv Radiat Oncol ; 6(2): 100644, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33732962

RESUMEN

PURPOSE: Postoperative stereotactic radiosurgery (SRS) is associated with up to 30% risk of subsequent leptomeningeal disease (LMD). Radiographic patterns of LMD (classical sugarcoating [cLMD] vs. nodular [nLMD]) in this setting has been shown to be prognostic. However, the association of these findings with neurologic death (ND) is not well described. METHODS AND MATERIALS: The records for patients with brain metastases who underwent surgical resection and adjunctive SRS to 1 lesion (SRS to other intact lesions was allowed) and subsequently developed LMD were combined from 7 tertiary care centers. Salvage radiation therapy (RT) for LMD was categorized according to use of whole-brain versus focal cranial RT. RESULTS: The study cohort included 125 patients with known cause of death. The ND rate in these patients was 79%, and the rate in patients who underwent LMD salvage treatment (n = 107) was 76%. Univariate logistic regression demonstrated radiographic pattern of LMD (cLMD vs. nLMD, odds ratio: 2.9; P = .04) and second LMD failure after salvage treatment (odds ratio: 3.9; P = .02) as significantly associated with ND. The ND rate was 86% for cLMD versus 68% for nLMD. Whole-brain RT was used in 95% of patients with cLMD and 52% with nLMD. In the nLMD cohort (n = 58), there was no difference in ND rate based on type of salvage RT (whole-brain RT: 67% vs. focal cranial RT: 68%, P = .92). CONCLUSIONS: LMD after surgery and SRS for brain metastases is a clinically significant event with high rates of ND. Classical LMD pattern (vs. nodular) and second LMD failure after salvage treatment were significantly associated with a higher risk of ND. Patients with nLMD treated with salvage focal cranial RT did not have higher ND rates compared with WBRT. Methods to decrease LMD and the subsequent high risk of ND in this setting warrant further investigation.

19.
Clin Neurol Neurosurg ; 194: 105842, 2020 07.
Artículo en Inglés | MEDLINE | ID: mdl-32325400

RESUMEN

OBJECTIVE: Digital subtraction angiography is the gold standard for diagnosis of vascular pathology. The value of angiography of non-target vessels following mechanical thrombectomy for the treatment of acute ischemic stroke (AIS) is unknown. PATIENTS AND METHODS: Consecutive patients treated with mechanical thrombectomy for AIS due to large vessel occlusion (LVO) at an academic institution between February 2016 and December 2018 were retrospectively reviewed. Demographic information, clinical data, and procedure details were recorded. Descriptive statistics were used to evaluate the utility of non-target vessel angiography. RESULTS: One hundred and fifty-six patients presenting with AIS due to LVO were treated with 159 mechanical thrombectomy procedures. Median age was 71.5 years. Ninety-one (57.2%) procedures were followed with a diagnostic cerebral angiogram of non-target vessels. Previously unknown findings were identified in 4 (4.4%) procedures. Management change due to the non-target vessel angiogram finding occurred in 3 (3.3%) cases and included one contralateral mechanical thrombectomy. No complications occurred as a result of the non-target vessel angiogram. CONCLUSION: Angiographic imaging of non-target vessels following mechanical thrombectomy identified previously unknown vascular pathology in 4.4% of procedures and resulted in a clinical management change in 3.3% of cases.


Asunto(s)
Angiografía Cerebral , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Accidente Cerebrovascular Isquémico/cirugía , Procedimientos Neuroquirúrgicos/métodos , Trombectomía/métodos , Anciano , Anciano de 80 o más Años , Angiografía de Substracción Digital , Angiografía por Tomografía Computarizada , Femenino , Humanos , Hallazgos Incidentales , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Sensibilidad y Especificidad , Resultado del Tratamiento
20.
World Neurosurg ; 144: e500-e506, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32891835

RESUMEN

BACKGROUND: Spinal arthrodesis is a commonly performed spinal operation. Spinal arthrodesis can be complicated by pseudoarthrosis and resultant hardware failure. Static magnetic fields (SMF) have the ability to improve bone fusion. We seek to assess the feasibility of the construction and implantation of a lumbar interbody cage equipped with a SMF in a caprine model. METHODS: Six skeletally mature female Boer goats underwent a lateral approach for placement of an interbody graft at lumbar (L) 1-2 and 3-4. The goats were divided into 2 groups of 3 animals. The interbody graft contained a neodymium iron boron magnet in the experimental group and a nonmagnetic titanium sham in the control group. Both groups contained a synthetic bone graft. Blinded radiographic and histologic evaluation was performed at predetermined timepoints to assess degree of bony fusion and osseointegration. RESULTS: All 6 goats underwent successful placement of lumbar interbody grafts. At the 1-month postoperative computed tomography, 1 goat in the experimental group and 1 goat in the control group were noted to have dislodged their intervertebral cage. Qualitative radiographic and histologic evaluation identified enhanced bone formation, bone density, and osteointegration of the graft in the experimental group. CONCLUSIONS: A spinal interbody cage containing a neodymium iron boron magnet for the production of a local SMF is feasible. Preliminary data suggests enhanced bone formation, bone density, and osseointegration of the graft.


Asunto(s)
Magnetoterapia/instrumentación , Fusión Vertebral/instrumentación , Animales , Cabras , Vértebras Lumbares , Oseointegración , Proyectos Piloto , Prótesis e Implantes , Distribución Aleatoria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA