Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Bases de datos
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 20(1): 6-16, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30536528

RESUMEN

BACKGROUND: Independent verification of the dose delivered by complex radiotherapy can be performed by electronic portal imaging device (EPID) dosimetry. This paper presents 5-yr EPID in vivo dosimetry (IVD) data obtained using the Dosimetry Check (DC) software on a large cohort including breast, lung, prostate, and head and neck (H&N) cancer patients. MATERIAL AND METHODS: The difference between in vivo dose measurements obtained by DC and point doses calculated by the Eclipse treatment planning system was obtained on 3795 radiotherapy patients treated with volumetric modulated arc therapy (VMAT) (n = 842) and three-dimensional conformal radiotherapy (3DCRT) (n = 2953) at 6, 10, and 15 MV. In cases where the dose difference exceeded ±10% further inspection and additional phantom measurements were performed. RESULTS: The mean and standard deviation ( µ ± σ ) of the percentage difference in dose obtained by DC and calculated by Eclipse in VMAT was: 0.19 ± 3.89 % in brain, 1.54 ± 4.87 % in H&N, and 1.23 ± 4.61 % in prostate cancer. In 3DCRT, this was 1.79 ± 3.51 % in brain, - 2.95 ± 5.67 % in breast, - 1.43 ± 4.38 % in bladder, 1.66 ± 4.77 % in H&N, 2.60 ± 5.35% in lung and - 3.62 ± 4.00 % in prostate cancer. A total of 153 plans exceeded the ±10% alert criteria, which included: 88 breast plans accounting for 7.9% of all breast treatments; 28 H&N plans accounting for 4.4% of all H&N treatments; and 12 prostate plans accounting for 3.5% of all prostate treatments. All deviations were found to be as a result of patient-related anatomical deviations and not from procedural errors. CONCLUSIONS: This preliminary data shows that EPID-based IVD with DC may not only be useful in detecting errors but has the potential to be used to establish site-specific dose action levels. The approach is straightforward and has been implemented as a radiographer-led service with no disruption to the patient and no impact on treatment time.


Asunto(s)
Neoplasias de la Mama/radioterapia , Neoplasias de Cabeza y Cuello/radioterapia , Dosimetría in Vivo/normas , Neoplasias Pulmonares/radioterapia , Fantasmas de Imagen , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Femenino , Humanos , Masculino , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/instrumentación , Radioterapia de Intensidad Modulada/métodos , Programas Informáticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA