Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
BMC Ophthalmol ; 23(1): 475, 2023 Nov 21.
Artículo en Inglés | MEDLINE | ID: mdl-37990206

RESUMEN

BACKGROUND: To prospectively evaluate visual functions and patient satisfaction after bilateral implantation of diffractive continuous depth-of-focus intraocular lens (CDF IOL) compared with trifocal IOLs. METHODS: This investigator-initiated study was approved by a certified local review board (registered: jRCTs032210305). CDF IOL (Synergy, J&J, group S) and trifocal IOL (AcrySof PanOptix, Alcon, group P) were implanted bilaterally in 30 patients each. Three months postoperatively, binocular outcomes of uncorrected (BUCVA) and distance-corrected (BDCVA) visual acuities at distances of 0.3, 0.4, 0.5, 0.7, and 5 m were measured. Contrast sensitivities were binocularly measured using CSV-1000 (2.5 m) and Pelli-Robson charts at distances of 0.4 and 1 m. Symptoms of glare, halo, starburst, and waxy vision, and satisfaction for near, intermediate, and far visions were assessed with questionnaires. Differences between the two groups were examined. RESULTS: Twenty-seven patients each completed the follow-up. The mean age of the group S was lower than that of the group P (P < 0.001). The BUCVA at 0.4 m was better in the S group, while the mean manifest refraction of the P group showed a significant hyperopic shift (P < 0.001). BDCVA was significantly better in the S group. The contrast sensitivity results at three distances showed no discernible differences. Although more patients in the S group reported significant glare and halo, their satisfaction with near vision was higher. CONCLUSIONS: The binocular visual function of patients with CDF IOLs was comparable to or better than that of patients with trifocal IOLs. The patients were satisfied with near vision, despite the enhanced glare and halo. Understanding the differences between the two types of presbyopia-correcting IOLs is important to ensure patient satisfaction. TRIAL REGISTRATION: This clinical trial was registered in the Japan Registry for Clinical Research (identifier: jRCTs032210305) on September 13, 2021.


Asunto(s)
Lentes Intraoculares , Miopía , Humanos , Sensibilidad de Contraste , Satisfacción del Paciente , Estudios Prospectivos , Diseño de Prótesis , Seudofaquia , Refracción Ocular , Visión Binocular , Agudeza Visual
2.
BMC Ophthalmol ; 20(1): 454, 2020 Nov 18.
Artículo en Inglés | MEDLINE | ID: mdl-33208137

RESUMEN

BACKGROUND: To prospectively evaluate surgical results following implantation of rotationally asymmetric, plate-haptic, refractive segmented multifocal toric intraocular lenses (IOLs) with near addition of + 1.5 diopters (D) (Lentis Comfort LS-313 MF15T, Oculentis GmbH). METHODS: In 59 eyes of 41 patients, ocular examinations were conducted before and 1 day, 1 week, 1, 3, and 6 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70 cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30 cm were tested. A defocus curve was drawn, and the degree of disturbing photic phenomena were questioned. RESULTS: The IOL showed excellent rotational stability; the average absolute rotation was 1.66 ± 1.17 degrees from 1 day 1 to 6 months postoperatively, and 98.1 and 100% of eyes yielded rotation of less than 5 and 10 degrees, respectively. Postoperative distance and intermediate visual acuity were highly satisfactory; UDVA, CDVA, UIVA, and DCIVA were about 20/20, 20/16, 20/25, 20/25, respectively. Near visual acuity was suboptimal; UNVA and DCNVA were at approximately 20/60. The defocus curve analysis showed that 20/25 and 20/40 uncorrected visual acuity was attained at as close as 60 and 40 cm, respectively. Contrast sensitivity was within a normal range, and subjective photic phenomena were minimum. CONCLUSIONS: The refractive segmented, rotationally asymmetric multifocal toric IOLs with + 1.5 D near addition showed superb rotational stability and highly satisfactory distance and intermediate vision. Contrast sensitivity was high and incidence of photic symptoms was very low. TRIAL REGISTRATION: This study was registered at JAPIC Clinical Trials Information, ID: JapicCTI-183,877, https://www.clinicaltrials.jp/cti-user/trial/Search.jsp (February 5, 2018).


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Estudios Prospectivos , Diseño de Prótesis , Seudofaquia , Refracción Ocular
3.
J Bone Miner Metab ; 37(2): 301-306, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29520506

RESUMEN

Adjuvant aromatase inhibitor (AI) therapy, for hormone receptor-positive breast cancer, in postmenopausal women is associated with bone loss, leading to an increased risk of fractures. Denosumab, an antibody raised against the receptor activator of nuclear factor-κB ligand, has been proven to protect against AI-induced bone loss. Hence, we aimed to determine whether denosumab is effective in postmenopausal Japanese women with osteoporosis, treated with AI. We prospectively evaluated the bone mineral density (BMD) in the lumbar spine and the bilateral femoral neck in 102 postmenopausal women with clinical hormone receptor-positive breast cancer, stages I-IIIA, during a postoperative period of 12 months. The other inclusion criteria for this study were: women that should receive AIs as adjuvant therapy and those with evidence of osteoporosis (lumbar spine or bilateral femoral neck BMD, equivalent to T-score classification of ≤ - 2.5) upon enrollment. The patients received supplemental calcium, vitamin D, and 60 mg of subcutaneous denosumab every 6 months. The BMD of the lumber spine increased by 4.9 and 6.6% at 6 and 12 months, respectively. An increase in BMD was observed at the femoral neck, bilaterally. Hypocalcemia ≥ grade 2, osteonecrosis of the jaw, and non-traumatic clinical fracture were not observed in this study. Our findings revealed that biannual treatment with denosumab is associated with a great increase of BMD in Japanese women receiving adjuvant AI therapy, irrespective of their previous history of AI therapy.


Asunto(s)
Inhibidores de la Aromatasa/uso terapéutico , Pueblo Asiatico , Densidad Ósea/efectos de los fármacos , Neoplasias de la Mama/tratamiento farmacológico , Denosumab/uso terapéutico , Osteoporosis/tratamiento farmacológico , Osteoporosis/fisiopatología , Anciano , Anciano de 80 o más Años , Fosfatasa Alcalina/metabolismo , Inhibidores de la Aromatasa/farmacología , Biomarcadores/sangre , Conservadores de la Densidad Ósea/farmacología , Conservadores de la Densidad Ósea/uso terapéutico , Remodelación Ósea/efectos de los fármacos , Neoplasias de la Mama/sangre , Neoplasias de la Mama/complicaciones , Denosumab/efectos adversos , Denosumab/farmacología , Femenino , Fracturas Óseas/patología , Humanos , Persona de Mediana Edad , Osteoporosis/sangre , Osteoporosis/complicaciones , Fosfatasa Ácida Tartratorresistente/metabolismo
4.
J Bone Miner Metab ; 37(5): 864-870, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30868270

RESUMEN

Aromatase inhibitors (AIs) are the gold standard therapy for breast cancer in postmenopausal women. AI suppresses the conversion of androgens to estrogens; however, this results in osteopenia, osteoporosis, and bone fracture, thus reducing the patient's quality of life. The use of adjuvant denosumab reduces the risk of clinical fractures in postmenopausal patients with breast cancer receiving AI. However, the efficacy of denosumab in the treatment of AI-associated bone loss has not been prospectively evaluated in Japan. In this study, we aimed to investigate the predictive factors for the efficacy of denosumab in postmenopausal patients with breast cancer treated with AI by analyzing the results of two prospective trials. The patients received 60 mg denosumab subcutaneously every 6 months. The primary endpoint was percentage change in lumbar spine bone mineral density (BMD) from baseline to month 12 in lumbar spine. Post hoc analysis and T tests were performed. A total of 205 patients were enrolled. At 12 and 24 months, the lumbar spine BMD increased by 5.6% [95% confidence interval (CI) 4.9-6.3] and 8.3% (95% CI 7.5-9.1), respectively. Subgroup analysis was conducted according to the time of AI therapy initiation, type of AI therapy, age, time since menopause, baseline body mass index, and BMD. The results showed that baseline lumbar and left femoral BMD was significantly associated with a percentage change in these sites, respectively. In addition, baseline left femoral BMD was also associated with a change in lumbar BMD. In conclusion, the baseline BMD in the lumbar spine was a predictive indicator for the efficacy of denosumab in this site and the baseline BMD in left femoral neck was a predictive indicator in lumbar spine and left femur.


Asunto(s)
Inhibidores de la Aromatasa/uso terapéutico , Pueblo Asiatico , Neoplasias de la Mama/tratamiento farmacológico , Denosumab/uso terapéutico , Posmenopausia , Anciano , Inhibidores de la Aromatasa/efectos adversos , Inhibidores de la Aromatasa/farmacología , Densidad Ósea/efectos de los fármacos , Conservadores de la Densidad Ósea/uso terapéutico , Neoplasias de la Mama/fisiopatología , Quimioterapia Adyuvante , Denosumab/efectos adversos , Denosumab/farmacología , Femenino , Cuello Femoral/efectos de los fármacos , Cuello Femoral/fisiopatología , Fracturas Óseas/inducido químicamente , Fracturas Óseas/tratamiento farmacológico , Humanos , Japón , Vértebras Lumbares/efectos de los fármacos , Vértebras Lumbares/fisiopatología , Persona de Mediana Edad , Análisis Multivariante , Posmenopausia/efectos de los fármacos , Estudios Prospectivos , Resultado del Tratamiento
5.
Ophthalmology ; 125(1): 31-35, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-28827044

RESUMEN

PURPOSE: To analyze the incidence and appropriate timing of repositioning surgery to correct misalignment of acrylic foldable toric intraocular lenses (IOLs). DESIGN: Retrospective, multicenter case series. PARTICIPANTS: Patients who had undergone phacoemulsification and implantation of toric IOL at 8 surgical sites. METHODS: Patient charts were reviewed to collect data on repositioning surgery of toric IOLs. MAIN OUTCOME MEASURES: Incidence, timing, and outcomes of repositioning surgery. RESULTS: Among 6431 eyes implanted with toric IOLs, 42 eyes (0.653%) of 42 patients underwent repositioning surgery at an average of 9.9±7.5 days (range, 0-30 days) after IOL implantation. The repositioning surgery significantly reduced misalignment from 32.9°±15.7° to 8.8°±9.7° (P < 0.001), which was measured at 7.6±5.0 weeks postoperatively. Refractive cylinder was significantly reduced from 2.4±1.1 diopters (D) to 1.1±0.8 D (P < 0.001). There was a significant negative correlation between the interval from cataract surgery to repositioning procedure and the degree of residual misalignment (r = -0.439, P < 0.001). The residual misalignment was 13.1°±13.5° when the repositioning surgery was performed within 6 days after cataract surgery, whereas the residual misalignment was 6.3°±5.9° when the IOL was repositioned 7 days or later (P < 0.001). In 2 eyes that were treated within 24 hours after cataract surgery, the IOL re-rotated significantly, and additional surgical intervention was required. CONCLUSIONS: Toric IOLs were repositioned in 0.653% of cases. A relationship was found between the timing of repositioning surgery and surgical outcome. These data suggest that repositioning surgery should be performed 1 week after IOL implantation.


Asunto(s)
Implantación de Lentes Intraoculares/efectos adversos , Lentes Intraoculares/efectos adversos , Complicaciones Posoperatorias/epidemiología , Refracción Ocular/fisiología , Agudeza Visual , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Facoemulsificación , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/cirugía , Diseño de Prótesis , Reoperación , Estudios Retrospectivos
6.
J Bone Miner Metab ; 36(6): 716-722, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-29116414

RESUMEN

Although adjuvant aromatase inhibitor (AI) therapy is widely used in postmenopausal women with hormone receptor-positive breast cancer, it is known to be associated with bone loss and increased fracture risk. Denosumab, a fully human monoclonal antibody against the receptor activator of nuclear factor-κB ligand, has been shown to protect against AI-induced bone loss. However, the efficacy of denosumab in the treatment of AI-associated bone loss has not been prospectively evaluated in Japan. We prospectively monitored bone mineral density (BMD) of the lumbar spine and bilateral femoral necks in 100 postmenopausal women with hormone receptor-positive postoperative breast cancer of clinical stage I-IIIA in whom treatment with AI as adjuvant endocrine therapy was planned or had been ongoing. Study participants received supplemental calcium and vitamin D every day and denosumab (60 mg) subcutaneously every 6 months. At enrollment, patients were required to have evidence of low bone mass without meeting the criteria for osteoporosis. The primary endpoint was percentage change from baseline in lumbar spine BMD at month 12. At 6 and 12 months, lumbar spine BMD increased by 3.3 and 4.7%, respectively. BMD of the femoral necks also increased. Hypocalcemia of grade ≥2, osteonecrosis of the jaw, and non-traumatic clinical fracture did not occur. In conclusion, semi-annual treatment with denosumab was associated with increased BMD in Japanese women receiving adjuvant AI therapy, regardless of prior AI treatment.


Asunto(s)
Adyuvantes Farmacéuticos/uso terapéutico , Inhibidores de la Aromatasa/uso terapéutico , Pueblo Asiatico , Densidad Ósea , Neoplasias de la Mama/tratamiento farmacológico , Denosumab/administración & dosificación , Denosumab/uso terapéutico , Posmenopausia/efectos de los fármacos , Adyuvantes Farmacéuticos/farmacología , Anciano , Anciano de 80 o más Años , Fosfatasa Alcalina/metabolismo , Biomarcadores/metabolismo , Densidad Ósea/efectos de los fármacos , Conservadores de la Densidad Ósea/uso terapéutico , Remodelación Ósea/efectos de los fármacos , Denosumab/efectos adversos , Femenino , Humanos , Japón , Persona de Mediana Edad , Fracturas Osteoporóticas/tratamiento farmacológico , Fosfatasa Ácida Tartratorresistente/metabolismo
7.
Gan To Kagaku Ryoho ; 45(1): 160-162, 2018 Jan.
Artículo en Japonés | MEDLINE | ID: mdl-29362341

RESUMEN

Laparoscopic stoma creation enables good visualization of viscera within the abdominal cavity to ensure adequate mobilization of the large intestine. Laparoscopic stoma creation/construction was indicated and performed at our hospital in 7 patients who were diagnosed with unresectable colorectal cancer between July 2015 and May 2017. Duringthe ileostomy procedure, we made a skin incision at the stoma site and performed a single-incision(3-port)laparoscopic surgery. For the colostomy procedure, we made a small incision at the umbilicus and mobilized the large intestine with laparoscopic dissection of any interveningadhesions. Operation time ranged between 34 and 127 minutes, and the volume of intraoperative blood loss was low in all cases. There were no fatal complications related to the operation. Laparoscopic stoma creation can be performed safely and may be useful for staging of malignant colorectal tumors and reducing the risk of complications.


Asunto(s)
Neoplasias Colorrectales/cirugía , Laparoscopía , Adulto , Anciano , Anciano de 80 o más Años , Colostomía/métodos , Femenino , Humanos , Laparoscopía/métodos , Masculino , Persona de Mediana Edad
8.
Gan To Kagaku Ryoho ; 42(3): 343-6, 2015 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-25812504

RESUMEN

Paclitaxel combined with bevacizumab yields significantly better progression-free survival (PFS) in patients with metastatic breast cancer than paclitaxel alone. Here, we report a case of stage IV breast cancer with multiple liver, lung, and bone metastases maintaining a long-term partial response (PR) with tri-weekly paclitaxel plus bevacizumab administration. A 46- year-old woman treated with endocrine therapy for 21 months for multiple metastases in her lungs and bones detected 4 years after surgery for left breast cancer was referred to our hospital. New metastases were discovered in her liver. She received paclitaxel (l 90 mg/m/(2)) on days 1, 8, and 15 combined with bevacizumab (10 mg/kg) on days 1 and 15 every 4 weeks. However, during the first 3 courses, the administration of paclitaxel on day 8 was postponed to 1 to 2 weeks because of severe neutropenia. We began tri-weekly administration of paclitaxel plus bevacizumab. She continued receiving the treatment for about 1 year, without severe side effects. The PR state with good performance status was maintained. We suggest that the tri-weekly administration of paclitaxel plus bevacizumab is an effective way to maintain long-term efficacy.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias de la Mama/tratamiento farmacológico , Anticuerpos Monoclonales Humanizados/administración & dosificación , Bevacizumab , Neoplasias de la Mama/patología , Femenino , Humanos , Persona de Mediana Edad , Metástasis de la Neoplasia , Estadificación de Neoplasias , Paclitaxel/administración & dosificación
9.
Nihon Jibiinkoka Gakkai Kaiho ; 116(10): 1126-30, 2013 Oct.
Artículo en Japonés | MEDLINE | ID: mdl-24313064

RESUMEN

Percutaneous endoscopic gastrostomy (PEG) has been generally used as a long-term enteral nutrition route for patients in whom oral intake is impossible. Percutaneous trans-esophageal gastrotubing (PTEG) is useful for the patients in whom PEG insertion has not been indicated. A gastroenterologist usually performs PTEG in Japan, but in our hospital otolaryngologists have performed this procedure. From 2006 to 2012, we experienced 9 patients who underwent PTEG insertion without a life-threatening adverse event. An otolaryngologist who is accustomed to the cervical procedures can safely perform PTEG insertion.


Asunto(s)
Ingestión de Alimentos/fisiología , Endoscopía del Sistema Digestivo , Nutrición Enteral/métodos , Estado Nutricional/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Endoscopía del Sistema Digestivo/instrumentación , Endoscopía del Sistema Digestivo/métodos , Nutrición Enteral/instrumentación , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
10.
Ophthalmol Ther ; 12(3): 1649-1656, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36947345

RESUMEN

INTRODUCTION: This study assessed 5-year results of rotationally asymmetric multifocal intraocular lens (IOL) with +1.5 diopters (D) near addition (Lentis Comfort LS-313 MF15, Teleon Surgical B.V., Spankeren, Netherlands). METHODS: In 38 eyes of 20 patients (76.8 ± 4.6 years) who were examined at both 1 and 5 years after surgery, clinical data were retrospectively collected. RESULTS: Corrected and uncorrected distance visual acuity (5 m) and uncorrected and distance-corrected intermediate visual acuity (70 cm) were excellent, with no significant differences between 1 and 5 years after surgery. Uncorrected and distance-corrected near visual acuity (30 cm) remained lower. Contrast sensitivity was within the normal range at both 1 and 5 years. The percentage of patients who reported "never or hardly use spectacles" for far, intermediate, and near vision was 95.0%, 85.0%, and 35.0%, respectively. Glare and halo were slightly increased from 1 to 5 years after surgery, but the severity remained none or mild. All patients reported "very high" or "high" level of overall satisfaction. There were no notable postoperative complications. CONCLUSIONS: During 5 years after surgery, low-add-power segmented multifocal IOL maintained excellent distance and intermediate visual acuity as well as good contrast sensitivity. Glare and halo symptoms were mild, and patients' satisfaction level was high. TRIAL REGISTRATION: University Hospital Medical Information Network Clinical Trials Registry (UMIN-CTR) identifier UMIN000048353.

11.
Gan To Kagaku Ryoho ; 39(11): 1699-702, 2012 Nov.
Artículo en Japonés | MEDLINE | ID: mdl-23152022

RESUMEN

A 63-year-old woman was suffering from HER2-positive and hormone receptor-negative breast cancer with bone metastasis. She received 16 cycles of paclitaxel(PTX 80mg/m2)plus trastuzumab(TRA 2mg/kg)on a 7-day cycle, and zoledronic acid(ZOL 4mg/body every 28 days), resulting in a near clinical complete response(cCR). Two years later, the patient complained of dizziness and nausea, and magnetic resonance imaging revealed multiple brain metastases. The prior treatments with PTX and TRA were changed to lapatinib(LAP)(orally at 1, 250mg/day every day)and capecitabine(CAP)(orally at 2, 000mg/m2 every day for 2 weeks, followed by a 1-week rest interval as 1 cycle)because of the multiple brain metastases. After 4 cycles of treatment, the number of brain lesions and the tumor sizes were significantly reduced. After 7 cycles, however, magnetic resonance imaging revealed the deterioration of some brain lesions. After whole-brain irradiation(30 Gy in 10 fractions)was added to the treatment, the outcome was near cCR. In conclusion, combination therapy of Lap and Cap may be an effective treatment option for brain metastasis of HER2-positive breast cancer.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Neoplasias Encefálicas/tratamiento farmacológico , Neoplasias de la Mama/tratamiento farmacológico , Receptor ErbB-2/análisis , Neoplasias Encefálicas/química , Neoplasias Encefálicas/secundario , Neoplasias Encefálicas/terapia , Neoplasias de la Mama/química , Neoplasias de la Mama/patología , Neoplasias de la Mama/terapia , Capecitabina , Quimioradioterapia , Desoxicitidina/administración & dosificación , Desoxicitidina/análogos & derivados , Femenino , Fluorouracilo/administración & dosificación , Fluorouracilo/análogos & derivados , Humanos , Lapatinib , Persona de Mediana Edad , Quinazolinas/administración & dosificación , Inducción de Remisión
12.
Sci Rep ; 12(1): 8457, 2022 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-35589932

RESUMEN

Surgical outcomes of toric intraocular lens (IOL) implantation for 8 years after surgery were analyzed. Data were retrospectively collected in 176 eyes of 176 patients before and 1 month, 1, 3, 5, and 8 years after phacoemulsification and implantation of a toric IOL. Preoperative corneal and postoperative manifest astigmatism was analyzed by converting to power vector notations; horizontal/vertical (J0) and oblique (J45) astigmatism components. Toric IOL implantation significantly reduced pre-existing astigmatism by decreasing J0 in eyes with preoperative with-the-rule (WTR) astigmatism, increasing J0 in eyes with against-the-rule (ATR) astigmatism, and correcting J45 in eyes with oblique astigmatism. After surgery, the eyes with preoperative ATR astigmatism showed a significant ATR astigmatic shift, and J0 at 5 and 8 years was significantly smaller than that at 1 month postoperatively. Uncorrected distance visual acuity was also significantly worse at 5 and 8 years than at 1 month postoperatively. In eyes with WTR and oblique astigmatism, the effects of toric IOLs on astigmatism and visual acuity were sustained for 8 years. The long-term astigmatism-correcting effects did not differ among the models of toric IOL used in this study, SN6AT3-8 (Alcon Laboratories). In eyes with preoperative ATR astigmatism, astigmatism-correcting effects of toric IOLs decreased at 5 years and later postoperatively, indicating that overcorrection may be considered at the time of cataract surgery. In eyes with WTR and oblique astigmatism, the effects of toric IOLs were maintained throughout the 8-year follow-up period.


Asunto(s)
Astigmatismo , Catarata , Linfoma Intraocular , Lentes Intraoculares , Facoemulsificación , Astigmatismo/complicaciones , Astigmatismo/cirugía , Catarata/complicaciones , Catarata/terapia , Humanos , Implantación de Lentes Intraoculares , Refracción Ocular , Estudios Retrospectivos
13.
Nihon Jibiinkoka Gakkai Kaiho ; 113(3): 101-9, 2010 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-20387597

RESUMEN

We evaluated clinical factors associated with concurrent chemoradiotherapy (CRT) toxicity and efficacy in resectable locoregionally advanced squamous cell carcinoma of the head and neck. Subject were 115 subjects with stage III or IV carcinoma undergooing 58 to 70 Gy of irradiation (median total dose: 66 Gy) concurrently with 2 cycles of chemotherapy of 5FU at 1000 mg/m2, 120-hour continuous infusion and cisplatin at 60 mg/m2. Grade 3 to 4 mucositits differed significantly between 13% in N0 and 59% in N1 to 2. No significant difference in planned therapy completion was seen between 87% in N0 and 82% in N1 to 2. Three-year overall survival (OS) was 66% and progression-free survival (PFS) 55%, in median follow-up of 42 months (range: 5.8 to 91 months). OS differed significantly between 86% in stage III and 57% in IV, 78% in T0 to 2 and 62% in T3 to 4, 83% in N0 to 1 and 53% in N2, 77% in adjuvant chemotherapy (nedaplatin plus UFT) and 50% in no adjuvant chemotherapy, and 33% in the tongue and 77% in the oropharynx. PFS significantly differed between 72% in T0 to 2 and 49% in T3 to 4, 77% in CR and 53% in PR, and 22% in the tongue and 58% in the hypopharynx, 66% in the oropharynx, and 53% in the larynx. Multivariable analysis showed strongly independent risk factors associated with OS and PFS to be advanced T and N stage, no adjuvant chemotherapy, and the tongue as the site. CRT was effective in treating resectable locoregionally advanced squamous cell carcinoma of the head and neck. It is possible that adjuvant chemotherapy will improve CRT OS and PFS. Other additional treatment will be needed, however, to improve OS and PFS in cases having a dismal diagnosis such as tongue cancer.


Asunto(s)
Protocolos de Quimioterapia Combinada Antineoplásica/efectos adversos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapéutico , Carcinoma de Células Escamosas/terapia , Neoplasias de Cabeza y Cuello/terapia , Adulto , Anciano , Antimetabolitos Antineoplásicos/administración & dosificación , Antimetabolitos Antineoplásicos/efectos adversos , Antineoplásicos/administración & dosificación , Antineoplásicos/efectos adversos , Cisplatino/administración & dosificación , Cisplatino/efectos adversos , Cisplatino/uso terapéutico , Terapia Combinada , Femenino , Fluorouracilo/administración & dosificación , Fluorouracilo/efectos adversos , Humanos , Masculino , Persona de Mediana Edad
14.
Nihon Jibiinkoka Gakkai Kaiho ; 113(3): 115-22, 2010 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-20387599

RESUMEN

Based on clinical features in 34 cases of parotid gland cancer treated between January 1997 and December 2007, tumor, node, and metastasis classification found 5 subjects to be T1, 12 to be T2, 7 to be T3, and 10 to be T4a. Of these, 25 were staged for N0, 3 for N1, and 6 for N2. Histopathologically, 10 different tumor types were observed, with carci-noma ex pleomorphic adenoma the most common. Preoperative fine-needle aspiration cytology (FNAC) of parotid gland tumor was done on 126 and cytological findings compared to histopathologic diagnoses of surgically resected specimens. Sensitivity for malignancy was 76.0%, specificity 95.4%, and overall accuracy 91.1%. Six malignant tumors were diagnosed as benign and 4 benign as malignant by FNAC, indicating that FNAC results alone may not be sufficient for diagnosing malignancy definitively. Among subjects, 25 underwent surgical resection, with the facial nerve preserved in 15 of 29. Postoperative radiotherapy was indicated if lymph node metastasis, intermediate or high-grade malignancy, or positive margins were seen. Of 15 subjects undergoing postoperative radiotherapy, 3 experienced recurrence. For unresectable tumors, concurrent chemoradiotherapy was used for 3 subjects and 2 underwent radiotherapy alone, with all 5 current survivors. The 5-year overall survival (OS) was 87.4% and progression-free survival (PFS) 71.4%. In terms of 5-year PFS, significant differences were seen between stage I/II (91.7%) and stage III/IW (51.6%) (P=0.032), and between N0 (86.2%) and N+ (38.1%) (P=0.002).


Asunto(s)
Neoplasias de la Parótida/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Terapia Combinada , Nervio Facial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Otorrinolaringológicos/métodos , Neoplasias de la Parótida/mortalidad , Neoplasias de la Parótida/patología , Neoplasias de la Parótida/terapia
15.
J Cataract Refract Surg ; 46(5): 682-687, 2020 May.
Artículo en Inglés | MEDLINE | ID: mdl-32358260

RESUMEN

PURPOSE: To investigate the clinical outcomes after implantation of a new hydrophobic acrylic intraocular lens (IOL) with hydroxyethyl methacrylate (HEMA) at 1 year and 9 years postoperatively. SETTING: Three surgical sites in Japan. DESIGN: Prospective case series and retrospective review. METHODS: In 110 eyes of 110 patients who underwent phacoemulsification and implantation of a new hydrophobic acrylic IOL (Clareon CNA0T0), clinical data were collected preoperatively and at 1 day, 1 week, 1 month, 6 months, and 12 months postoperatively. Of these eyes, 20 eyes of 20 patients were examined at 9 years postoperatively, and corrected distance visual acuity (CDVA) and clarity of the IOL were evaluated. RESULTS: All 110 patients (110 eyes) completed every follow-up examination up to 12 months postoperatively. At 12 months, a CDVA of 20/30 and 20/20 was obtained in 110 (100%) and 101 (91.8%) of 110 eyes, respectively. The contrast sensitivity function was better than or similar to the age-matched normal controls, and there was no case of posterior capsule opacification requiring a laser treatment. Glistenings and surface light scattering were not seen in any of these cases. At 9 years postoperatively, a CDVA of 20/40, 20/30, and 20/20 was attained in 20 (100%), 19 (95%), and 14 (70%) of 20 eyes, respectively. One eye (5%) was treated with laser capsulotomy for posterior capsule opacification. There was no case of glistenings and surface light scattering. CONCLUSIONS: This mid-term and long-term study indicated that the new hydrophobic acrylic IOL with HEMA was safe and effective with excellent postoperative vision. Glistenings and surface light scattering did not develop with this IOL in contrast to its predecessor.


Asunto(s)
Resinas Acrílicas , Implantación de Lentes Intraoculares , Lentes Intraoculares , Metacrilatos , Facoemulsificación , Anciano , Anciano de 80 o más Años , Sensibilidad de Contraste/fisiología , Femenino , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Seudofaquia/fisiopatología , Agudeza Visual/fisiología
16.
Eur J Ophthalmol ; 30(4): 680-684, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-30841757

RESUMEN

PURPOSE: To compare the incidence of re-orientating surgery to improve misalignment of three models of acrylic toric intraocular lenses: AcrySof toric intraocular lens (Alcon Laboratories, Inc.), TECNIS toric intraocular lens (Johnson & Johnson Vision, Inc.) and HOYA 355 toric intraocular lens (HOYA). METHODS: In this retrospective, multicenter case series, medical charts were reviewed for collecting data on realignment surgery of toric intraocular lenses at 10 ophthalmic surgical sites in Japan. RESULTS: Over all, intraocular lens repositioning surgery was conducted in 89 of 9430 eyes (0.944%) at an average of 10.5 ± 9.7 days after the initial cataract surgery. The incidence was 0.213% (11/5155), 1.797% (62/3451) and 1.942% (16/824) with AcrySof, TECNIS and HOYA toric intraocular lenses, respectively. The incidence was significantly lower with AcrySof than with other two brands of toric intraocular lenses (p < 0.0001). In those eyes which underwent reorientation surgery, the amount of misalignment was 26.4 ± 21.9°, 29.7 ± 15.4° and 28.1 ± 20.7° with AcrySof, TECNIS and HOYA toric intraocular lenses, respectively; there was no significant difference among groups (p = 0.821). The repositioning surgery significantly reduced misalignment in all three groups. CONCLUSION: The rotational stability was considerably different among toric intraocular lenses of different manufacturers. The incidence of repositioning surgery was significantly lower with AcrySof than with TECNIS and HOYA toric intraocular lenses.


Asunto(s)
Migracion de Implante de Lente Artificial/epidemiología , Migracion de Implante de Lente Artificial/cirugía , Implantación de Lentes Intraoculares , Lentes Intraoculares , Complicaciones Posoperatorias , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Astigmatismo/fisiopatología , Longitud Axial del Ojo , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Facoemulsificación , Seudofaquia/fisiopatología , Reoperación , Estudios Retrospectivos , Agudeza Visual/fisiología , Adulto Joven
17.
Sci Rep ; 9(1): 13117, 2019 09 11.
Artículo en Inglés | MEDLINE | ID: mdl-31511557

RESUMEN

We conducted a one-year prospective, multicenter study to assess clinical outcomes after implantation of segmented, rotationally asymmetric multifocal intraocular lenses (IOLs) with +1.5 diopters (D) near addition. In this phase III clinical trial, 120 eyes of 65 patients undergoing phacoemulsification and implantation of Lentis Comfort LS-313 MF15 (Oculentis GmbH) were included. The ophthalmological examinations were performed before and 1 day, 1 week, 1, 3, 6, 9, and 12 months after surgery. Uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UIVA) and distance-corrected (DCIVA) intermediate visual acuity at 70 cm, and uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity at 30 cm were measured. A defocus curve was obtained and patients were asked about the severity of photic phenomena. Postoperative distance and intermediate visual acuity was excellent, with UDVA, CDVA, UIVA, and DCIVA of approximately 20/20, 20/16, 20/25, 20/25 were attained, respectively. The level of near visual acuity was lower; UNVA and DCNVA remained at around 20/60 and 20/70, respectively. The defocus curve indicated that postoperative uncorrected visual acuity of 20/25 and 20/40 was obtained at as close as 67 cm and 50 cm, respectively. Contrast sensitivity was within the normal range, with a minimal level of subjective symptoms and high patient satisfaction. The rotationally asymmetric multifocal IOLs with +1.5 D near addition provided excellent distance and intermediate vision, but near vision was not enough for reading small prints. Contrast sensitivity was high, with very low incidences of photic phenomena and a high level of patient satisfaction.


Asunto(s)
Visión de Colores/fisiología , Sensibilidad de Contraste/fisiología , Lentes Intraoculares Multifocales/estadística & datos numéricos , Seudofaquia/fisiopatología , Seudofaquia/terapia , Visión Binocular/fisiología , Agudeza Visual/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Implantación de Lentes Intraoculares , Masculino , Persona de Mediana Edad , Pronóstico , Estudios Prospectivos
18.
J Pharmacol Exp Ther ; 326(1): 163-70, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18411413

RESUMEN

In the present report, we evaluated the effect of the novel acid pump antagonist 7-(4-fluorobenzyloxy)-2,3-dimethyl-1-{[(1S,2S)-2-methylcyclopropyl]methyl}-1H-pyrrolo[2,3-d]pyridazine (CS-526) and 2-[3-methyl-4-(2,2,2-trifluoro-ethoxy)-pyridin-2-ylmethanesulfinyl]-1H-benzimidazole (lansoprazole) on rebound gastric acid secretion, using an intragastric dialysis membrane perfusion model and on the serum and antral gastrin level after a 14-day treatment in rats. The effect of CS-526 on gastric acid secretion was almost constant during the 14 days of treatment. After the 14-day treatment, gastric acid secretion had returned to pretreatment levels. However, CS-526 slightly increased and lansoprazole potently increased gastric acid secretion thereafter. In the posttreatment period, the influence on rebound gastric acid secretion by lansoprazole treatment was significant, but that by CS-526 was not. The serum gastrin concentration after the 14-day treatment with CS-526 did not increase significantly, even at 100 mg/kg/day. On the other hand, lansoprazole at 100 mg/kg/day significantly elevated the serum gastrin concentration. After the 14-day treatment with CS-526 at 100 mg/kg/day, the antral gastrin content significantly increased. Lansoprazole at the doses of 30 and 100 mg/kg/day also significantly increased the antral gastrin content after the 14-day treatment. The elevation of the serum gastrin level after the lansoprazole treatment was suppressed by the concomitant administration of CS-526. In conclusion, CS-526 has a potent antisecretory effect on gastric acid secretion without rebound gastric hypersecretion. Moreover, CS-526 had minimal effects on the serum and antral gastrin elevation. It is suggested that these effects on gastric acid secretion and serum gastrin after subchronic treatment with CS-526 would be beneficial in clinical use.


Asunto(s)
Ácido Gástrico/metabolismo , Gastrinas/sangre , Inhibidores de la Bomba de Protones , Bombas de Protones/sangre , Piridazinas/administración & dosificación , Pirroles/administración & dosificación , Animales , Ritmo Circadiano/efectos de los fármacos , Ritmo Circadiano/fisiología , Relación Dosis-Respuesta a Droga , Esquema de Medicación , Gastrinas/análisis , Masculino , Bombas de Protones/metabolismo , Ratas , Ratas Sprague-Dawley
19.
Ther Clin Risk Manag ; 14: 1213-1218, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30022834

RESUMEN

BACKGROUND: The aim of the study was to conduct subgroup analyses of therapeutic effects of 12-month denosumab therapy on the percentage change in bone mineral density (BMD) from baseline in the lumber spine and femoral neck. MATERIALS AND METHODS: We prospectively evaluated the BMD of the lumbar spine and femoral neck of 100 hormone receptor-positive, clinical stage I-IIIA postoperative postmenopausal breast cancer patients, for whom treatment with aromatase inhibitors (AIs) as adjuvant endocrine therapy was scheduled. The primary endpoint was the percent change in lumbar spine BMD from baseline to 12 months. Patient subgroups were analyzed according to baseline variables that are known risk factors for bone loss, including previous AI therapy, age, time since menopause, baseline body mass index (BMI), and baseline BMD T-score. RESULTS: At 12 months, lumbar spine BMD increased by 4.7%; the patients who were administered AI therapy prior to denosumab (n=70) demonstrated a 4.7% increase in BMD, and the patients who received denosumab at the start of AI therapy (n=30) demonstrated a 4.5% increase in BMD (p=0.8385). Additionally, 2.4% and 1.4% increases in BMD of the right and left femoral neck, respectively, were observed. Initiation of AI (with denosumab, before denosumab), type of AI (non-steroidal, steroidal), age (<65, ≥65 years), time since menopause (≤5, >5 years), BMI (<25, ≥25 kg/m2), and T-score (≤-1.0, >-1.0) of the right femoral neck were as follows: (2.2%, 2.5%, p=0.7773), (2.6%, 0.9%, p=0.1726), (2.5%, 2.3%, p=0.7594), (2.1%, 2.4%, p=0.2034), (2.1%, 2.9%, p=0.2034), and (2.3%, 2.7%, p=0.6823), respectively. Initiation of AI (with denosumab, before denosumab), type of AI (non-steroidal, steroidal), age (<65, ≥65 years), time since menopause (≤5, >5 years), BMI (<25, ≥25 kg/m2), and T-score (≤-1.0, >-1.0) of the left femoral neck were as follows: (1.0%, 1.5%, p=0.1972), (1.2%, 2.7%, p=0.2931), (1.4%, 1.3%, p=0.8817), (-0.1%, 1.6%, p=0.1766), (1.3%, 1.9%, p=0.6465), and (1.5%, 1.1%, p=0.6573), respectively. CONCLUSION: Twice-yearly treatment with denosumab was associated with increased BMD among Japanese women receiving adjuvant AI therapy, regardless of the baseline characteristics or skeletal site.

20.
J Cataract Refract Surg ; 44(2): 219-225, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29587977

RESUMEN

PURPOSE: To assess the long-term influence of surface light scattering and glistenings of hydrophobic acrylic (Acrysof), silicone, and poly(methyl methacrylate) (PMMA) intraocular lenses (IOLs) on visual function. SETTING: Eleven surgical sites, Japan. DESIGN: Retrospective case series. METHODS: Patients who had cataract surgery with implantation of a hydrophobic acrylic, silicone, or PMMA IOL from 1994 to 2000 were examined. Silicone and PMMA IOLs were not restricted to specific manufacturers or models. Patients were included if their corrected distance visual acuity (CDVA) within 3 months postoperatively (baseline CDVA) was 20/25 or better. The CDVA, contrast sensitivity, degree of surface light scattering measured with Pentacam densitometry, and glistening grades were recorded at the patient's latest visit. RESULTS: Of the eyes, 31 had a hydrophobic acrylic IOL, 37 a silicone IOL, and 30 a PMMA IOL. Surface light scattering and glistenings were significantly greater with the hydrophobic acrylic IOL than with silicone and PMMA IOLs (P < .0001). The CDVA at the latest visit as well as the changes in CDVA from the baseline to the latest visit did not differ between the IOLs and was unaffected by surface light scattering and glistenings, as was the contrast sensitivity. CONCLUSIONS: The hydrophobic acrylic IOL was associated with a significantly greater level of surface light scattering and glistenings than the silicone IOLs and PMMA IOLs 15 to 20 years postoperatively. However, the optical phenomena within the optics of the hydrophobic acrylic IOL did not influence the patients' visual function.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Facoemulsificación , Dispersión de Radiación , Vacuolas , Agudeza Visual/fisiología , Resinas Acrílicas , Adulto , Anciano , Anciano de 80 o más Años , Sensibilidad de Contraste/fisiología , Femenino , Deslumbramiento , Humanos , Luz , Masculino , Persona de Mediana Edad , Polimetil Metacrilato , Estudios Retrospectivos , Elastómeros de Silicona , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA