Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
Optom Vis Sci ; 98(12): 1379-1386, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34686635

RESUMEN

SIGNIFICANCE: This investigation examines the effectiveness of several common contact lens solutions in the disinfection of Acanthamoeba, which causes a serious eye infection most often resulting from dysfunctional or improper use of contact lens products. PURPOSE: Acanthamoeba keratitis is an eye infection caused by a free-living amoeba, which can lead to extensive corneal damage and frequently blindness. Acanthamoeba keratitis is linked with contact lens use combined with noncompliance with contact lens care cleaning regimens. The patient's choice and use of multipurpose solutions (MPSs) continue to be a risk factor for Acanthamoeba keratitis. Thus, it is critical that the Acanthamoeba disinfection efficacy of the popular MPSs be determined. Here we compare the efficacy of seven major MPSs on the global market. METHODS: Using standard methods of Acanthamoeba disinfection and quantification, Acanthamoeba ATCC 30461, 30868, 50370, and 50676 trophozoites were inoculated into each MPS and held for the manufacturer's recommended disinfection time. Acanthamoeba recovery plates were incubated for 14 days, after which positive wells were identified and cell concentrations determined using the 50% endpoint method. RESULTS: Members of the OPTI-FREE products (Express, Replenish, and Puremoist [Alcon, Fort Worth, TX]) demonstrated significantly higher percentages of antimicrobial activity compared with the renu Advanced Formula (Bausch + Lomb, Rochester, NY), Biotrue (Bausch + Lomb), Acuvue RevitaLens (Johnson & Johnson, Santa Ana, CA), and Lite products (Cooper Vision, Scottsville, NY) for four of the trophozoite strains tested. CONCLUSIONS: Many of the popular MPS biocides maintain little or no antimicrobial activity against Acanthamoeba trophozoites, and the number of biocides in an MPS does not necessarily indicate its antimicrobial activity.


Asunto(s)
Queratitis por Acanthamoeba , Acanthamoeba , Antiinfecciosos , Queratitis por Acanthamoeba/prevención & control , Animales , Antiinfecciosos/farmacología , Soluciones para Lentes de Contacto/farmacología , Humanos , Trofozoítos
2.
Eye Contact Lens ; 45(3): 164-170, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30138250

RESUMEN

PURPOSE: To compare the antimicrobial effects of CLEAR CARE, a 3% hydrogen peroxide (H2O2) solution formulated for simultaneous cleaning, daily protein removal, disinfection, and storage of soft (hydrophilic) hydrogel, silicone hydrogel, and gas-permeable contact lenses, and CLEAR CARE PLUS, consisting of the 3% H2O2 solution plus a novel wetting agent, polyoxyethylene-polyoxybutylene (EOBO-21). METHODS: Three lots each of the 2 solutions were incubated with 5 compendial microorganisms required by the Food and Drug Administration (FDA) 510(k) and International Organization for Standardization (ISO) 14729 stand-alone procedures, 4 clinical isolates of Gram-positive and Gram-negative bacteria, and trophozoites and cysts of 2 Acanthamoeba strains that are associated with microbial keratitis. Microbial loads were evaluated after disinfection and neutralization. RESULTS: Both solutions exceeded the FDA/ISO stand-alone primary criteria against Gram-positive and Gram-negative compendial bacteria, yeast, and mold after only 1.5-hr disinfection/neutralization. At the recommended minimum disinfection time, bacteria were reduced by 4.4 to 5.1 logs, yeast by 4.4 to 4.9 logs, and mold by 2.9 to 3.5 logs with and without organic soil. In addition, both solutions eliminated or effectively reduced populations of clinically relevant ocular bacterial isolates (4.5-5.0 logs), Acanthamoeba trophozoites (3.4-4.2 logs), and cysts (1.5-2.1 logs). CONCLUSION: Both solutions eliminated or reduced populations of FDA/ISO compendial bacteria and fungi as well as clinically relevant microorganisms and Acanthamoeba trophozoites and cysts. The addition of EOBO-21 to the 3% H2O2 lens care solution had no impact on antimicrobial activity.


Asunto(s)
Acanthamoeba/efectos de los fármacos , Antibacterianos/farmacología , Soluciones para Lentes de Contacto/farmacología , Bacterias Gramnegativas/efectos de los fármacos , Bacterias Grampositivas/efectos de los fármacos , Peróxido de Hidrógeno/farmacología , Agentes Mojantes/farmacología , Lentes de Contacto Hidrofílicos/microbiología , Desinfectantes , Hongos/efectos de los fármacos , Polienos/farmacología , Polietilenglicoles/farmacología , Trofozoítos/efectos de los fármacos
3.
Eye Contact Lens ; 44(2): 125-131, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-27598555

RESUMEN

OBJECTIVE: The aim of this study was to use antimicrobial efficacy endpoint methodology to determine compatibility of multipurpose disinfecting solutions (MPSs), lens cases, and hydrogel lenses for disinfection (AEEMC) against International Organization for Standardization (ISO)-specified microorganisms and clinical ocular isolates of Stenotrophomonas maltophilia. METHODS: Six MPSs (PQ/Aldox 1, 2, and 3; PQ/Alexidine; PQ/PHMB; and PHMB) were challenged against ISO-specified microorganisms and S. maltophilia using the AEEMC test. AEEMC tests were performed with and without balafilcon A, etafilcon A, and senofilcon A lenses in lens cases with organic soil. Exposure times included disinfection time (DT) and 24 hr. Additionally, all six MPSs were challenged with two strains of S. maltophilia, based on the ISO Stand-alone test. RESULTS: The efficacy against bacteria for PQ/Aldox and PQ/Alexidine MPSs was not diminished by the presence of lenses. The efficacy of PQ/PHMB and PHMB MPSs against Serratia marcescens was significantly reduced compared with the no-lens control at DT for at least one lens type. The PHMB MPS with lenses present also demonstrated reduced efficacy against Staphylococcus aureus at DT versus the control. PQ/Aldox MPSs retained activity against Fusarium solani with lenses present; however, all other test MPSs demonstrated reduced F. solani efficacy at DT with lenses present. With lenses, all MPSs showed reduced efficacy against Candida albicans. CONCLUSIONS: AEEMC antimicrobial efficacy test results vary based on challenge microorganism, contact lenses, and MPS biocide systems. This study highlights the importance of evaluating MPSs for compatibility with lenses and lens cases.


Asunto(s)
Antiinfecciosos/farmacología , Soluciones para Lentes de Contacto/farmacología , Lentes de Contacto Hidrofílicos/microbiología , Desinfectantes/farmacología , Desinfección/normas , Bacterias/efectos de los fármacos , Bacterias/aislamiento & purificación , Recuento de Colonia Microbiana , Desinfección/métodos , Hongos/efectos de los fármacos , Hongos/aislamiento & purificación , Humanos , Pruebas de Sensibilidad Microbiana , Levaduras/efectos de los fármacos , Levaduras/aislamiento & purificación
4.
Eye Contact Lens ; 40(5): 277-82, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25099866

RESUMEN

OBJECTIVE: Lipid deposition on silicone hydrogel (SiHy) lenses, which are believed to be caused by their hydrophobic surface, can lead to discomfort, reduced vision, and inflammatory reactions. This study used a highly specific and sensitive fluorometric enzymatic assay for ex vivo cholesterol analysis of seven types of SiHy lenses: balafilcon A, comfilcon A, enfilcon A, enhanced-lotrafilcon A, enhanced-lotrafilcon B, galyfilcon A, and senofilcon A. METHODS: Cholesterol sorption was assessed in 140 previously worn SiHy lenses from 8 clinical trials conducted in the United States and Australia between 2006 and 2008. Patients wore the lenses for 2 to 4 weeks. Unworn negative control lenses for each lens material were obtained directly from the manufacturer. Lipids were isolated from the lenses using a two-step chloroform: methanol extraction method, and total cholesterol was quantified using a fluorometric enzymatic assay. Nonparametric Mann Whitney statistical analysis was performed to determine the differences in total cholesterol sorption between lens-specific data sets. RESULTS: Enhanced-lotrafilcon A and enhanced-lotrafilcon B contact lenses showed significantly lower median total cholesterol sorption (median±quartile, 0.30±0.2 µg/lens and 0.09±0.1 µg/lens, respectively) than all other types of lenses that were tested (P<0.0001). By contrast, enfilcon A (3.96±0.8 µg/lens) and galyfilcon A (3.75±1.1 µg/lens) showed the highest median total cholesterol sorption of all tested lenses. CONCLUSIONS: Cholesterol deposition in SiHy contact lenses seems to be lens polymer dependent. Enhanced-lotrafilcon A and enhanced-lotrafilcon B both sorbed the lowest amount of cholesterol compared with the other five types of SiHy lenses that were tested in this study.


Asunto(s)
Colesterol/análisis , Lentes de Contacto Hidrofílicos , Adolescente , Adulto , Niño , Colesterol/química , Femenino , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato/química , Metabolismo de los Lípidos , Masculino , Persona de Mediana Edad , Siliconas/química , Adulto Joven
5.
Optom Vis Sci ; 89(3): 326-35, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22246331

RESUMEN

PURPOSE: Bacterial contamination of the contact lens surface has been demonstrated to cause corneal infiltrative events. A reduction in the rate of bacterially driven corneal infiltrative events associated with lens wear is one of the major goals of the contact lens industry. There is a concern over the potential of any antimicrobial strategy that there will be unwanted changes to the ocular microbiota or the development of resistance to the antimicrobial. The aim of this study was to investigate the effect of prophylactic topical antibiotic instillation during continuous wear of silicone hydrogel lenses on the normal ocular microbiota, the throat microbiota, and the ocular physiology. METHODS: Forty-two male subjects were dispensed with lotrafilcon A silicone hydrogel contact lenses for a 3-month, 30 night continuous wear, monthly replacement trial. Subjects were randomized into either tobramycin 0.3% (test) or saline (control) drop group. Two drops were instilled into each eye on waking and before sleep. At monthly visits, lenses were collected aseptically, and ocular and throat swabs were performed, followed by standard microbial recovery and identifications. Any corneal infiltrative event at scheduled or unscheduled visits was recorded. RESULTS: Numbers of microbes recovered from eye swabs from the tobramycin (test) group were significantly lower than the control (p = 0.01). Gram-positive cocci were recovered less frequently from the test group (p = 0.001). There were no significant differences in the numbers and types of microbes recovered from lens samples, or the contamination rate of the lenses between the two groups. There were no changes in the numbers of fungi or bacteria from throat swabs. There was no evidence of changes to resistance profile of microbes in the throat. More eye swabs from the test group (68.5%) were culture-negative than swabs from control (46.5%; p = 0.002). The test group had less corneal staining superiorly (0.0 ± 0.0 vs. 0.3 ± 0.4; p = 0.025) but increased bulbar redness (2.2 ± 0.5 vs. 1.5 ± 0.4; p < 0.001) at the 3-month visit only, compared with control group. CONCLUSIONS: Overall, there appeared to be a minimal safety risk with 3-month's prophylactic antibiotic drop use during continuous wear of silicone hydrogel lenses. Clinically, antibiotic drop use induced a mild to moderate increase in bulbar redness by the 3-month time-point. Antibiotic use reduced microbiota on lids but did not affect the microbiota of the throat or change resistance to tobramycin.


Asunto(s)
Antibacterianos/administración & dosificación , Lentes de Contacto de Uso Prolongado/microbiología , Córnea/efectos de los fármacos , Infecciones Bacterianas del Ojo/prevención & control , Queratitis/prevención & control , Metagenoma/efectos de los fármacos , Siliconas , Adulto , Córnea/microbiología , Córnea/fisiopatología , Infecciones Bacterianas del Ojo/microbiología , Infecciones Bacterianas del Ojo/fisiopatología , Femenino , Estudios de Seguimiento , Humanos , Queratitis/microbiología , Queratitis/fisiopatología , Masculino , Soluciones Oftálmicas , Estudios Prospectivos , Factores de Tiempo , Tobramicina/administración & dosificación , Resultado del Tratamiento
6.
Microbiol Spectr ; 10(1): e0213821, 2022 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-35138157

RESUMEN

Microbial keratitis is a devastating disease that can cause eye damage and blindness and can be the result of infections by several common ocular pathogens. Importantly, some of these pathogens, such as Acanthamoeba, are particularly unsusceptible to biocides in common contact lens care solutions. Therefore, the disinfection efficacy of preservative-free (PF) disinfection systems against bacteria, fungi, and Acanthamoeba trophozoites and cysts should be assessed as products with the most potential to be efficacious against resistant organisms. PF disinfection systems were analyzed for antimicrobial efficacy. These were the one-step (hydrogen peroxide-based) Clear Care and Clear Care Plus systems and the two-step (povidone-iodine-based) Cleadew system. Stand-alone challenges using bacteria, fungi, and Acanthamoeba were prepared according to the International Standards Organization method 14729. These same challenges were also conducted in the presence of the following contact lenses: Boston RGP, Acuvue Oasys, Biofinity, Ultra, and 2-week PremiO. All challenges were performed at the manufacturer's recommended disinfection time. All preservative-free disinfection systems demonstrated similarly high rates of antimicrobial efficacy when challenged with bacteria or fungi, with or without lenses. However, both Clear Care and Clear Care Plus demonstrated significantly greater disinfection efficacy against Acanthamoeba trophozoites and cysts, with and without lenses (P < 0.05). Cleadew efficacy was impacted by the addition of contact lenses, whereas Clear Care/Clear Care Plus maintained similar efficacies in the absence or presence of lenses. While both hydrogen peroxide and povidone-iodine are highly effective against bacteria and fungi, hydrogen peroxide maintains significantly greater disinfection capabilities than povidone-iodine against all forms of Acanthamoeba. IMPORTANCE Understanding the most efficacious products will allow clinicians to best communicate to patients and consumers the safest products on the market to reduce adverse events, including microbial keratitis, during contact lens use.


Asunto(s)
Antiinfecciosos/farmacología , Soluciones para Lentes de Contacto/farmacología , Desinfección/métodos , Oftalmopatías/prevención & control , Acanthamoeba/efectos de los fármacos , Bacterias/efectos de los fármacos , Lentes de Contacto/microbiología , Lentes de Contacto/parasitología , Desinfección/instrumentación , Oftalmopatías/microbiología , Oftalmopatías/parasitología , Hongos/efectos de los fármacos , Humanos , Peróxido de Hidrógeno/farmacología , Povidona Yodada/farmacología
7.
BMJ Open Ophthalmol ; 7(1)2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-36161836

RESUMEN

OBJECTIVE: Sight-threatening infections can be caused by pathogenic micro-organisms colonising the cornea, leading to microbial keratitis (MK). These micro-organisms can be introduced to the eye via improper contact lens use and care. MK can also result from ineffective contact lens care solutions (CLCs), even if the patient is following best practice guidelines. Therefore, it is critical to understand the differences between the effectiveness of popular CLCs on the global market. METHODS AND ANALYSIS: Following the International Standards Organisation standards 14 729 and 18259, bacteria (Pseudomonas aeruginosa, Serratia marcescens, Staphylococcus aureus), fungi (Candida albicans, Fusarium strains) and Acanthamoeba strains were inoculated into each CLC with and without contact lenses, and held for the manufacturer's stated disinfection time. Plate counts were conducted to determine the number of surviving micro-organisms. RESULTS: All CLCs examined met the primary log reduction criteria during stand-alone testing for Pseudomonas, Staphylococcus, Candida and Fusarium. renu Multiplus, All Clean Soft, and Kombilösung Super did not meet the primary criteria when challenged with Serratia. Only OPTI-FREE Express exceeded 4 log reduction for both strains of Acanthamoeba tested. We noted a substantial reduction in disinfection efficacy when CLCs were challenged with Fusarium in the presence of lenses and cases versus stand-alone testing. OPTI-FREE Express demonstrated significantly less net log reduction loss than the other four CLCs tested. CONCLUSION: Of the popular CLCs on the global market, the product which relies on dual biocides polyquaternium-1 and myristamidopropyl dimethylamine demonstrated the highest disinfection efficacy in microbial disinfection challenges in the absence and presence of contact lenses.


Asunto(s)
Acanthamoeba , Lentes de Contacto , Desinfectantes , Fusarium , Queratitis , Candida albicans , Recuento de Colonia Microbiana , Soluciones para Lentes de Contacto/farmacología , Lentes de Contacto/microbiología , Desinfectantes/farmacología , Desinfección , Humanos , Queratitis/prevención & control , Serratia marcescens
8.
Pathogens ; 10(2)2021 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-33670669

RESUMEN

While the results of Acanthamoeba testing have been extensively published, laboratories conducting such testing are left to develop their own methods in the absence of a standardized methodology. The wide disparity of methods has resulted in equally inconsistent reported results for contact lens care (CLC) products. This study's objective was to determine the source of these discrepancies by evaluating basic Acanthamoeba biology and their impact on antimicrobial efficacy testing, including the ability of a recovery method to stimulate a single trophozoite to proliferate. Antimicrobial efficacy testing was conducted using well-published Acanthamoeba strains, storage conditions, and growth-based recovery methods. To identify variables that influence results, test solutions with low Acanthamoeba disinfection rates were utilized to prevent differences from being masked by high log reductions. In addition, single-cell proliferation assays were executed to understand the growth requirements to stimulate trophozoite propagation in two recovery methods. These studies indicated that both nutrient density (>106 CFU) and the length of plate incubation (at least 14 days) could significantly influence the accurate recovery of trophozoites. Together, this study emphasizes the need to understand how Acanthamoeba trophozoites biology can impact test methods to create divergent results.

9.
Clin Optom (Auckl) ; 13: 7-14, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33469402

RESUMEN

CLEAR CARE PLUS (CCP), also known as AOSEPT PLUS with HydraGlyde, is approved for use with gas permeable (GP) lenses, and the indication is supported by the scientific evidence that is reviewed in this article. Antimicrobial efficacy testing of CCP both as a stand-alone disinfectant and as part of a regimen shows that CCP exceeds the ISO 14729 criteria against bacteria, yeast, and mold. In real-world conditions, it is effective against clinically relevant bacterial strains isolated from adverse events and against the two forms, trophozoites and cysts, of resilient Acanthamoeba species. Compatibility tests of CCP with two types of GP lenses indicate that the physical and/or optical parameters of lenses are unaffected through 30 cycles of simulated use with CCP, and a clinical trial shows substantial equivalence of clinical performance with a commonly used GP multipurpose solution. These results indicate that CCP is well suited for cleaning and disinfection of GP contact lenses.

10.
Microorganisms ; 9(10)2021 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-34683493

RESUMEN

Microbial keratitis (MK) is an eye infection caused by opportunistic bacteria or fungi, which may lead to sight-threatening corneal ulcers. These microorganisms can be introduced to the eye via improper contact lens usage or hygiene, or ineffective multipurpose solutions (MPSs) to disinfect daily wear contact lenses. Thus, the patient's choice and use of these MPSs is a known risk factor for the development of MK. It is then critical to determine the efficacy of popular MPSs against ubiquitous ocular microorganisms. Therefore, we compare the efficacy of nine major MPSs on the global market against four different microorganism species, and with four different common contact lenses. In accordance with International Standards Organization protocol 14729 and 18259, the microorganisms were inoculated into each MPS with and without contact lenses, and held for the manufacturer's disinfection time, 24 h, and 7 days after challenge with Serratia marcescens or Fusarium spp. Plates were incubated for 2-7 days and plate counts were conducted to determine the number of surviving microorganisms. The majority of MPSs demonstrated significantly higher disinfection efficacies without contact lenses. Broadly, among the microorganisms tested, the OPTI-FREE products (Puremoist, Express, and Replenish) maintained the highest disinfection efficacies at the manufacturer's stated disinfection time when paired with any contact lens, compared with other MPSs. These were followed closely by RevitaLens and renu Advanced. MPSs containing dual biocides polyquaternium-1 and myristamidopropyl dimethylamine possessed the highest disinfection efficacy against multiple ocular pathogens.

11.
Eye Contact Lens ; 34(6): 306-11, 2008 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18997538

RESUMEN

OBJECTIVES: This study used a rat contact lens (CL) model to test if high- versus low-Dk lens wear caused changes in (1) conjunctival Langerhans cell (LC) number or location; (2) Bcl-2 expression; and (3) infection risk. METHODS: Female, Lewis rats wore a high- or low-Dk CL continuously for 2 weeks. Afterward, corneas were harvested and processed for ADPase activity to identify LCs, for immunostaining and for real time-polymerase chain reaction. Contact lens-wearing rats also were challenged with Pseudomonas aeruginosa by placing a bacterial-soaked CL on the eye followed by topical delivery of bacteria. After 48 hrs, slit lamp examination and real time-polymerase chain reaction were used to evaluate the corneal response. RESULTS: Conjunctival LC were significantly increased after low- versus high-Dk CL wear (P<0.0001). In contrast, conjunctival LC in non-lens wearing rats was not significantly different from the high-Dk lens wearing group. Bcl-2 mRNA levels were significantly decreased in low- versus high-Dk CL wearing rats, while Bax, FasL, caspase 3, and caspase 9 levels were unchanged. Immunostaining for Bcl-2 showed fewer positively stained epithelial cells in the low- versus high-Dk lens wearing group. After bacterial challenge, 30% of low- versus none of the high-Dk CL wearing corneas became infected and showed increased mRNA levels for several proinflammatory cytokines/chemokines, inducible nitric oxide synthase and matrix metalloproteinase-9. CONCLUSION: Low- versus high-Dk or non-CL wear led to an increased number of conjunctival LC, decreased Bcl-2 levels, and increased the risk of bacterial infection.


Asunto(s)
Conjuntiva/patología , Lentes de Contacto/efectos adversos , Infecciones Bacterianas del Ojo/etiología , Hidrogel de Polietilenoglicol-Dimetacrilato , Infecciones por Pseudomonas/etiología , Siliconas , Animales , Recuento de Células , Córnea/microbiología , Susceptibilidad a Enfermedades , Regulación hacia Abajo , Diseño de Equipo , Ojo/metabolismo , Infecciones Bacterianas del Ojo/epidemiología , Femenino , Incidencia , Células de Langerhans/patología , Proteínas Proto-Oncogénicas c-bcl-2/genética , Infecciones por Pseudomonas/epidemiología , ARN Mensajero/metabolismo , Ratas , Ratas Endogámicas Lew , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Medición de Riesgo
12.
Front Microbiol ; 7: 871, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-27375592

RESUMEN

Pseudomonas aeruginosa is a leading cause of human morbidity and mortality that often targets epithelial surfaces. Host immunocompromise, or the presence of indwelling medical devices, including contact lenses, can predispose to infection. While medical devices are known to accumulate bacterial biofilms, it is not well understood why resistant epithelial surfaces become susceptible to P. aeruginosa. Many bacteria, including P. aeruginosa, release outer membrane vesicles (OMVs) in response to stress that can fuse with host cells to alter their function. Here, we tested the hypothesis that mucosal fluid can trigger OMV release to compromise an epithelial barrier. This was tested using tear fluid and corneal epithelial cells in vitro and in vivo. After 1 h both human tear fluid, and the tear component lysozyme, greatly enhanced OMV release from P. aeruginosa strain PAO1 compared to phosphate buffered saline (PBS) controls (∼100-fold). Transmission electron microscopy (TEM) and SDS-PAGE showed tear fluid and lysozyme-induced OMVs were similar in size and protein composition, but differed from biofilm-harvested OMVs, the latter smaller with fewer proteins. Lysozyme-induced OMVs were cytotoxic to human corneal epithelial cells in vitro and murine corneal epithelium in vivo. OMV exposure in vivo enhanced Ly6G/C expression at the corneal surface, suggesting myeloid cell recruitment, and primed the cornea for bacterial adhesion (∼4-fold, P < 0.01). Sonication disrupted OMVs retained cytotoxic activity, but did not promote adhesion, suggesting the latter required OMV-mediated events beyond cell killing. These data suggest that mucosal fluid induced P. aeruginosa OMVs could contribute to loss of epithelial barrier function during medical device-related infections.

14.
Eye Contact Lens ; 33(6 Pt 2): 426-9; discussion 434, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-17975440

RESUMEN

Contact lenses are a safe and effective mode of vision correction used by more than 100 million people worldwide, yet some adverse responses to microbial contamination of contact lenses still occur. Various medical devices, including contact lens cases, currently use antimicrobial agents to eliminate or reduce microbial contamination at the surface. The application of antimicrobial surface technologies to contact lenses and lens cases is being explored. This article describes agents that hold promise for antimicrobial surfaces for contact lenses or lens cases.


Asunto(s)
Antiinfecciosos/administración & dosificación , Lentes de Contacto/efectos adversos , Lentes de Contacto/microbiología , Antiinfecciosos/farmacología , Biopelículas/efectos de los fármacos , Contaminación de Equipos/prevención & control , Radicales Libres/metabolismo , Humanos , Percepción de Quorum
15.
Eye Contact Lens ; 32(1): 12-8, 2006 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-16415687

RESUMEN

PURPOSE: To examine the early host response to Pseudomonas aeruginosa challenge in the extended contact lens-wearing rat model. METHODS: Lewis rats were fitted with extended-wear lotrafilcon A hydrogel lenses in the left eye, and the right eye served as the control. Bacterial challenge was initiated in the experimental eye by fitting a bacteria-soaked contact lens and by topical delivery of the bacteria. On first detection of corneal opacity, slitlamp examination, histopathologic examination, viable bacteria counts, enzyme-linked immunosorbent assay, myeloperoxidase, Langerhans cell detection, and multiprobe ribonuclease protection assays were used to evaluate the early corneal response. RESULTS: Analysis of bacterially challenged contact lens-wearing versus control rats showed Langerhans cells and polymorphonuclear neutrophils only in the experimentally challenged cornea. In addition, in the experimentally challenged cornea, ribonuclease protection and enzyme-linked immunosorbent analyses showed an upregulation of proinflammatory cytokines, including interleukins 1beta and 6, suggesting that with contact lens wear, these cytokines contribute to the early corneal response and, potentially, disease. CONCLUSIONS: The contact lens-wearing rat model allows a unique analysis of the early effects of bacterial challenge in extended-wear contact lenses in the absence of corneal scarring, used in most rodent models. The rat model should be valuable to delineate further the effects of contact lens wear, including the testing of additional contact lens-related complications.


Asunto(s)
Lentes de Contacto de Uso Prolongado/microbiología , Infecciones Bacterianas del Ojo/microbiología , Queratitis/microbiología , Infecciones Relacionadas con Prótesis/microbiología , Infecciones por Pseudomonas/microbiología , Pseudomonas aeruginosa/aislamiento & purificación , Animales , Lentes de Contacto de Uso Prolongado/efectos adversos , Córnea/metabolismo , Córnea/microbiología , Córnea/patología , Modelos Animales de Enfermedad , Ensayo de Inmunoadsorción Enzimática , Infecciones Bacterianas del Ojo/metabolismo , Infecciones Bacterianas del Ojo/patología , Femenino , Interleucina-1/metabolismo , Interleucina-6/metabolismo , Queratitis/metabolismo , Queratitis/patología , Células de Langerhans/patología , Infecciones Relacionadas con Prótesis/metabolismo , Infecciones Relacionadas con Prótesis/patología , Infecciones por Pseudomonas/metabolismo , Infecciones por Pseudomonas/patología , Ratas , Ratas Endogámicas Lew
16.
Eye Contact Lens ; 31(2): 54-61, 2005 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-15798474

RESUMEN

PURPOSE: Extracellular proteinase production and biofilm structure of Pseudomonas aeruginosa are affected by acylated homoserine lactones (AHLs) termed quorum sensing (QS) factors. C12- and C4-AHLs of P. aeruginosa and a synthetic furanone signaling antagonist were evaluated for effects on growth, primary adhesion to hydrogel contact lenses, and elastase B production of P. aeruginosa strains, including QS mutants, and isolates of Staphylococcus aureus and Staphylococcus epidermidis. METHODS: Acylated homoserine lactones and furanone were added to cultures of bacteria at various growth stages. Primary adhesion of P. aeruginosa to lenses soaked in AHLs and furanone was examined by adenosine triphosphate analysis. Elastase B activity of cultures exposed to AHLs and furanone was determined by an elastin congo red assay. RESULTS: Acylated homoserine lactones had no significant effects on maximal cell densities or primary adhesion. Adhesion of a lasI-rhlI- QS mutant to lenses was significantly lower than its wild-type (WT) strain, regardless of added AHL or furanone. Exogenous AHLs had negligible effects on elastase production of WT P. aeruginosa but restored elastase production in QS-deficient mutants. The furanone was biocidal for staphylococci but enhanced growth of the lasI-rhlI- QS mutant. The furanone decreased elastase production of WT strains but increased QS mutant elastase production. CONCLUSIONS: Exogenous AHLs and the furanone were of minor importance in initial adhesion of P. aeruginosa to lenses. The furanone decreased staphylococci growth and elastase production of WT P. aeruginosa but increased growth and elastase production of QS mutants. The data further indicate strain diversity in P. aeruginosa and complexity of AHL systems.


Asunto(s)
4-Butirolactona/análogos & derivados , 4-Butirolactona/fisiología , Adhesión Bacteriana , Proteínas Bacterianas/biosíntesis , Proteínas Bacterianas/fisiología , Lentes de Contacto Hidrofílicos/microbiología , Metaloendopeptidasas/biosíntesis , Pseudomonas aeruginosa/crecimiento & desarrollo , Pseudomonas aeruginosa/enzimología , Staphylococcus aureus/enzimología , Staphylococcus aureus/crecimiento & desarrollo , Staphylococcus epidermidis/enzimología , Staphylococcus epidermidis/crecimiento & desarrollo
17.
Eye Contact Lens ; 29(1 Suppl): S105-9; discussion S115-8, S192-4, 2003 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-12772744

RESUMEN

PURPOSE: Bacterial strains with known capability to bind to hydrogel lenses were examined for their relative capacities to attach irreversibly to a hydrogel contact lens in pure and mixed cultures. METHODS AND RESULTS: Time course studies of adhesion through adenosine triphosphate (ATP) or radiolabel analyses indicated that primary adhesion by Pseudomonas aeruginosa to a 37% water-content hydrogel lens was more dense and rapid than that of Staphylococcus epidermidis. Primary adhesion of P. aeruginosa was similar after 5 min and 2 hr, whereas S. epidermidis showed an incremental increase in adhesion over the first 30 min. Sequential challenge of lenses with P. aeruginosa followed by S. epidermidis gave levels of primary adhesion for each species similar to those obtained with single pure cultures. When lenses were challenged with S. epidermidis first, primary adhesion of P. aeruginosa was significantly diminished. Exposures of multiple sets of lenses (n = 4) to a standard inoculum of P. aeruginosa resulted in levels of primary adhesion per lens after 1 hr equivalent to that found for a single lens in 5 min or in 2 hr. CONCLUSION: These data further support that normal biota may be protective for the eye. The data also suggest that under conditions of the primary adhesion-screening test, a limited number of cells of GSU no. 3 (selected phenotype) are involved in adhesion to the hydrogel.


Asunto(s)
Adhesión Bacteriana , Lentes de Contacto Hidrofílicos/microbiología , Pseudomonas aeruginosa/fisiología , Staphylococcus epidermidis/fisiología , Adenosina Trifosfato/análisis , Recuento de Colonia Microbiana , Factores de Tiempo
18.
CLAO J ; 28(3): 119-23, 2002 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-12144229

RESUMEN

PURPOSE: To develop a rat model to experimentally monitor the potential inflammatory effects of soft contact lens (CL) usage on the cornea during extended wear (EW). METHODS: Lewis rats were fitted with EW lotrafilcon A (CIBA Vision, Duluth, GA) hydrogel lenses (Dk/t 175 barrers/cm) in the left eye, the right eye serving as a control. After 12 days (n = 5 rats) and 30 days (n = 8 rats) of continuous extended wear, corneas were removed and total RNA was extracted from both CL-wearing and non-lens-wearing eyes. Multiprobe ribonuclease protection assays (RPA) were used to detect and compare cytokine and chemokine gene expression in corneas from both groups. RESULTS: Cytokine-chemokine mRNA expression levels were similar for interleukin (IL)-1alpha, IL-1 receptor antagonist (RA), IL- 18, transforming growth factor (TGF)-beta1, TGF-beta2, TGF-beta3, and macrophage migration inhibitory factor (MIF) levels in CL-wearing and non-lens-wearing corneas after 12 or 30 days of EW. CONCLUSION: This in vivo rat model for extended contact lens wear allows analysis and comparison of mRNA levels of cytokines and chemokines in the cornea with and without EW soft CL use. Remarkably, after 12 or 30 days of continuous CL wear, there was no significant up-regulation in lens wearing corneas for any of the cytokines-chemokines tested.


Asunto(s)
Lentes de Contacto de Uso Prolongado , Modelos Animales , Animales , Quimiocinas/genética , Quimiocinas/metabolismo , Córnea/metabolismo , Citocinas/genética , Citocinas/metabolismo , Femenino , Hidrogel de Polietilenoglicol-Dimetacrilato , Hibridación in Situ , ARN Mensajero/metabolismo , Ratas , Ratas Endogámicas Lew
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA