RESUMEN
BACKGROUND: Rapid economic and cultural transition in the United Arab Emirates has been accompanied by a rise in chronic disease. Early childhood is known to affect health outcomes in adulthood. This prospective longitudinal study examined the general health of Emirati infants born in a government maternity hospital in the Emirate of Abu Dhabi in October 2002. METHODS: One hundred twenty-five women, who had recently given birth, were interviewed as part of a larger study encompassing a wide range of cultural, social, and behavioural aspects of health. They were then re-interviewed at three (n = 94), six (n = 59) and 15 months postpartum (n = 52). Data are presented using univariate statistics. RESULTS: In this study seven infants (6%) were born prematurely and four infants (3%) were classified as small for gestational age, while 11 (9%) of the infants weighed less than 2500 g. Low birth weight infants (LBW) were significantly more likely to require treatment in the neonatal intensive care unit (OR = 30.83, p = 0.00). Iron supplementation during pregnancy was associated with fewer underweight infants (OR = 3.92, p = 0.042). No associations were found between infant birth weight and maternal age, age at marriage, consanguinity, education level, current maternal employment, parity, pre-existing anaemia or anaemia in pregnancy, diabetes, folic acid intake, multivitamin intake or infant gender. Maternally-reported infant health issues, vaccination, medication, breast-feeding and infant nutrition, and use of secure car seats are also reported. CONCLUSIONS: The health of infants at birth in this UAE sample showed improvements compared to previous studies. The proportion of LBW infants is decreasing and continuing improvements in health care in the UAE are having a positive impact on infant health.
Asunto(s)
Salud del Lactante/tendencias , Adolescente , Adulto , Países en Desarrollo , Femenino , Humanos , Lactante , Recién Nacido de Bajo Peso , Recién Nacido , Recien Nacido Prematuro , Recién Nacido Pequeño para la Edad Gestacional , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Embarazo , Complicaciones del Embarazo/epidemiología , Estudios Prospectivos , Cambio Social , Emiratos Árabes Unidos , Adulto JovenRESUMEN
The purpose of this study was to compare the effects of two practical precooling techniques (skin cooling vs. skin + core cooling) on cycling time trial performance in warm conditions. Six trained cyclists completed one maximal graded exercise test (VO2(peak) 71.4 +/- 3.2 ml x kg(-1) x min(-1)) and four approximately 40 min laboratory cycling time trials in a heat chamber (34.3 degrees C +/- 1.1 degrees C; 41.2% +/- 3.0% rh) using a fixed-power/variable-power format. Cyclists prepared for the time trial using three techniques administered in a randomised order prior to the warm-up: (1) no cooling (control), (2) cooling jacket for 40 min (jacket) or (3) 30-min water immersion followed by a cooling jacket application for 40 min (combined). Rectal temperature prior to the time trial was 37.8 degrees C +/- 0.1 degrees C in control, similar in jacket (37.8 degrees C +/- 0.3 degrees C) and lower in combined (37.1 degrees C +/- 0.2 degrees C, P < 0.01). Compared with the control trial, time trial performance was not different for jacket precooling (-16 +/- 36 s, -0.7%; P = 0.35) but was faster for combined precooling (-42 +/- 25 s, - .8%; P = 0.009). In conclusion, a practical combined precooling strategy that involves immersion in cool water followed by the use of a cooling jacket can produce decrease in rectal temperature that persist throughout a warm-up and improve laboratory cycling time trial performance in warm conditions.
Asunto(s)
Temperatura Corporal , Ejercicio Físico/fisiología , Adulto , Temperatura Corporal/fisiología , Regulación de la Temperatura Corporal/fisiología , Frío , Estudios Cruzados , Frecuencia Cardíaca , Humanos , Inmersión , Masculino , Resistencia Física/fisiología , Análisis y Desempeño de TareasRESUMEN
Infants rely on their innate immune systems to protect them from infection. Human milk (HM) contains fatty acids (FAs) and monoacylglycerols that are known to exhibit antiviral and antibacterial properties in vitro. The specific fat content of HM may potentially affect the efficacy of this antimicrobial activity. This preliminary study investigates whether the proportions of FA in HM change in response to infections, leading to cold-like symptoms in the mother or infant. Milk samples were obtained from mothers (n = 26) when they and their infants were healthy, and when mother, infant, or both suffered cold-like symptoms. The milk was hydrolysed and FA proportions were measured using gas chromatography. Fifteen FAs were recorded, of which eight were detected in sufficient quantities for statistical analysis. The proportions of capric (C10:0) and lauric acids (C12:0) in HM were significantly lower, and palmitic acid (C16:0) was higher when mothers and infants were ill compared to healthy samples. Palmitoleic (C16:1, n-7) and stearic acid (C18:0) proportions were higher in HM when the infant was unwell, but were not related to maternal health. Whilst the differences detected were small (less than 0.5%), the effects may be additive and potentially have a protective function. The value of further studies is certainly indicated.
Asunto(s)
Resfriado Común , Ácidos Grasos/análisis , Leche Humana/química , Adulto , Australia , Preescolar , Femenino , Análisis de los Alimentos , Edad Gestacional , Humanos , Lactante , Lactancia , MadresRESUMEN
PURPOSE: : Although manufacturers of bicycle power monitoring devices SRM and Power Tap (PT) claim accuracy to within 2.5%, there are limited scientific data available in support. The purpose of this investigation was to assess the accuracy of SRM and PT under different conditions. METHODS: : First, 19 SRM were calibrated, raced for 11 months, and retested using a dynamic CALRIG (50-1000 W at 100 rpm). Second, using the same procedure, five PT were repeat tested on alternate days. Third, the most accurate SRM and PT were tested for the influence of cadence (60, 80, 100, 120 rpm), temperature (8 and 21 degrees C) and time (1 h at ~300 W) on accuracy. Finally, the same SRM and PT were downloaded and compared after random cadence and gear surges using the CALRIG and on a training ride. RESULTS: : The mean error scores for SRM and PT factory calibration over a range of 50 - 1000 W were 2.3 +/- 4.9% and -2.5 +/- 0.5%, respectively. A second set of trials provided stable results for 15 calibrated SRM after 11 months (-0.8 +/- 1.7%), and follow-up testing of all PT units confirmed these findings (-2.7 +/- 0.1%). Accuracy for SRM and PT was not largely influenced by time and cadence; however, power output readings were noticeably influenced by temperature (5.2% for SRM and 8.4% for PT). During field trials, SRM average and max power were 4.8% and 7.3% lower, respectively, compared with PT. CONCLUSIONS: : When operated according to manufacturers instructions, both SRM and PT offer the coach, athlete, and sport scientist the ability to accurately monitor power output in the lab and the field. Calibration procedures matching performance tests (duration, power, cadence, and temperature) are, however, advised as the error associated with each unit may vary.
Asunto(s)
Ciclismo , Monitoreo Fisiológico/instrumentación , Australia , CalibraciónRESUMEN
UNLABELLED: Cold water immersion (CWI) has become a popular means of enhancing recovery from various forms of exercise. However, there is minimal scientific information on the physiological effects of CWI following cycling in the heat. PURPOSE: To examine the safety and acute thermoregulatory, cardiovascular, metabolic, endocrine, and inflammatory responses to CWI following cycling in the heat. METHODS: Eleven male endurance trained cyclists completed two simulated approximately 40-min time trials at 34.3 +/- 1.1 degrees C. All subjects completed both a CWI trial (11.5 degrees C for 60 s repeated three times) and a control condition (CONT; passive recovery in 24.2 +/- 1.8 degrees C) in a randomized cross-over design. Capillary blood samples were assayed for lactate, glucose, pH, and blood gases. Venous blood samples were assayed for catecholamines, cortisol, testosterone, creatine kinase, C-reactive protein, IL-6, and IGF-1 on 7 of the 11 subjects. Heart rate (HR), rectal (Tre), and skin temperatures (Tsk) were measured throughout recovery. RESULTS: CWI elicited a significantly lower HR (CWI: Delta 116 +/- 9 bpm vs. CONT: Delta 106 +/- 4 bpm; P = .02), Tre (CWI: Delta 1.99 +/- 0.50 degrees C vs. CONT: Delta 1.49 +/- 0.50 degrees C; P = .01) and Tsk. However, all other measures were not significantly different between conditions. All participants subjectively reported enhanced sensations of recovery following CWI. CONCLUSION: CWI did not result in hypothermia and can be considered safe following high intensity cycling in the heat, using the above protocol. CWI significantly reduced heart rate and core temperature; however, all other metabolic and endocrine markers were not affected by CWI.