Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Más filtros

Bases de datos
Tipo del documento
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 59(7)2023 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-37512121

RESUMEN

Background and Objectives: The aim of this study was to investigate under dynamic loading the potential biomechanical benefit of simulated first tarsometatarsal (TMT-1) fusion with low-profile superelastic nitinol staples used as continuous compression implants (CCIs) in two different configurations in comparison to crossed screws and locked plating in a human anatomical model. Materials and Methods: Thirty-two paired human anatomical lower legs were randomized to four groups for TMT-1 treatment via: (1) crossed-screws fixation with two 4.0 mm fully threaded lag screws; (2) plate-and-screw fixation with a 4.0 mm standard fully threaded cortex screw, inserted axially in lag fashion, and a 6-hole TMT-1 Variable-Angle (VA) Fusion Plate 2.4/2.7; (3) CCI fixation with two two-leg staples placed orthogonally to each other; (4) CCI fixation with one two-leg staple and one four-leg staple placed orthogonally to each other. Each specimen was biomechanically tested simulating forefoot weightbearing on the toes and metatarsals. The testing was performed at 35-37 °C under progressively increasing cyclic axial loading until construct failure, accompanied by motion tracking capturing movements in the joints. Results: Combined adduction and dorsiflexion movement of the TMT-1 joint in unloaded foot condition was associated with no significant differences among all pairs of groups (p ≥ 0.128). In contrast, the amplitude of this movement between unloaded and loaded foot conditions within each cycle was significantly bigger for the two CCI fixation techniques compared to both crossed-screws and plate-and-screw techniques (p ≤ 0.041). No significant differences were detected between the two CCI fixation techniques, as well as between the crossed-screws and plate-and-screw techniques (p ≥ 0.493) for this parameter of interest. Furthermore, displacements at the dorsal and plantar aspects of the TMT-1 joint in unloaded foot condition, together with their amplitudes, did not differ significantly among all pairs of groups (p ≥ 0.224). Conclusions: The low-profile superelastic nitinol staples demonstrate comparable biomechanical performance to established crossed-screws and plate-and-screw techniques applied for fusion of the first tarsometatarsal joint.


Asunto(s)
Pie , Huesos Metatarsianos , Humanos , Aleaciones , Fenómenos Biomecánicos , Placas Óseas , Cadáver , Huesos Metatarsianos/cirugía
2.
Medicina (Kaunas) ; 59(2)2023 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-36837571

RESUMEN

Background and Objectives: Proximal humerus fractures (PHFs) are common in the elderly, but the treatment results are often poor. A clear understanding of fracture morphology and distribution of cortical bone loss is important for improved surgical decision making, operative considerations, and new implant designs. The aim of this study was to develop a 3D segmentation fracture mapping technique to create a statistical description of the spatial pattern and cortical bone loss of complex PHFs. Materials and Methods: Fifty clinical computed tomography (CT) scans of complex PHFs and their contralateral intact shoulders were collected. In-house software was developed for semi-automated segmentation and fracture line detection and was combined with manual fracture reduction to the contralateral template in a commercial software. A statistical mean model of these cases was built and used to describe probability maps of the fracture lines and cortical fragments. Results: The fracture lines predominantly passed through the surgical neck and between the tuberosities and tendon insertions. The superior aspects of the tuberosities were constant fragments where comminution was less likely. Some fracture lines passed through the bicipital sulcus, but predominantly at its edges and curving around the tuberosities proximally and distally. Conclusions: A comprehensive and systematic approach was developed for processing clinical CT images of complex fractures into fracture morphology and fragment probability maps and applied on PHFs. This information creates an important basis for better understanding of fracture morphology that could be utilized in future studies for surgical training and implant design.


Asunto(s)
Enfermedades Óseas Metabólicas , Fracturas Conminutas , Fracturas del Hombro , Humanos , Anciano , Fijación Interna de Fracturas , Fracturas del Hombro/cirugía , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Fracturas Conminutas/cirugía
3.
J Anat ; 241(3): 756-764, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35662008

RESUMEN

The pelvic ring is a complex anatomical structure building up the connection between the trunk and the legs. Whilst there is a broad discussion in the literature about the dynamic interaction between spine, pelvis and the hip joints, there is still little information about the relation and interaction of the constant pelvic parameters. Based on a three-dimensional (3D) statistical model consisting of 150 uninjured and bony healthy pelves (100 Europeans, 50 Japanese; 81 males, 69 females; average age 74.3 years ± 17.5 years) an evaluation of pelvic incidence (PI) and acetabular orientation in anteversion and inclination was performed and potential correlations of these intraindividual constant parameters were investigated. Pelvic incidence is defined as the angle between the perpendicular to the sacral plate at its midpoint and the line connecting this point to the middle axis of the femoral heads. Acetabular anteversion is defined as the angle between the perpendicular to the best-fit plane on the acetabular rim and the coronal plane measured in strict lateral view. Acetabular inclination is defined as the angle between the perpendicular to the best-fit plane on the acetabular rim and the sagittal plane in strict frontal view. Data were further analysed with regard to different subgroup's age, sex and ethnicity. A positive correlation between PI and acetabular anteversion could be demonstrated. Further, PI and also the acetabular parameters anteversion and inclination were found to be significantly higher in the European individuals than in the Asian. The results of the present study demonstrate a relation between the anatomical configuration of the constant pelvic parameters building up the connection points to the next proximal respectively caudal skeleton section. The findings might lead to more comprehensive treatment strategies in case of trauma or degenerative pathologies of the pelvis in the future.


Asunto(s)
Acetábulo , Huesos Pélvicos , Acetábulo/diagnóstico por imagen , Anciano , Femenino , Articulación de la Cadera , Humanos , Masculino , Modelos Estadísticos , Huesos Pélvicos/diagnóstico por imagen , Pelvis
4.
Eur Spine J ; 31(10): 2812-2821, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35976438

RESUMEN

PURPOSE: Implant leakage is the most common complication of vertebral augmentation. Alternative injectable materials must demonstrate intravascular safety comparable to or better than polymethyl methacrylate (PMMA). This study assessed the systemic effects of a triphasic calcium-based implant or PMMA injected directly into the femoral vein in a large animal model designed to mimic severe intravascular implant leakage. METHODS: Six skeletally mature female sheep were randomly assigned (n = 3) to either the PMMA or the triphasic implant (AGN1, composition: calcium sulfate, ß-tricalcium phosphate, brushite) treatment group. Femoral veins of each sheep were directly injected with 0.5 mL of implant material to mimic leakage volumes reported during PMMA vertebroplasty. To compare acute systemic effects of the materials, cardiovascular parameters, laboratory coagulation markers, and calcium and sulfate serum levels were monitored for 60 min after implant injection. Thrombotic and embolic events were evaluated by radiologic imaging, necropsy, and histopathology. RESULTS: Heart rate, systemic arterial blood pressure, arterial oxygenation, arterial carbon dioxide content, and coagulation markers remained within physiological range after either AGN1 or PMMA injection. No blood flow interruption in the larger pulmonary vessels was observed in either group. Lung histopathology revealed that the severity of thrombotic changes after AGN1 injection was minimal to slight, while changes after PMMA injection were minimal to massive. CONCLUSION: Acute systemic effects of intravascular AGN1 appeared to be comparable to or less than that of intravascular PMMA. Furthermore, in this preliminary study, the severity and incidence of pulmonary histological changes were lower for AGN1 compared to PMMA.


Asunto(s)
Embolia Pulmonar , Vertebroplastia , Animales , Cementos para Huesos , Calcio , Sulfato de Calcio , Dióxido de Carbono , Femenino , Polimetil Metacrilato , Ovinos , Vertebroplastia/métodos
5.
Vet Surg ; 51(4): 576-591, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-35302250

RESUMEN

OBJECTIVE: To determine the influence of screw head diameter on equine condylar fracture fixation with 5.5 mm cortical screws. STUDY DESIGN: Ex vivo, biomechanical study, blinded, matched-pair design. SAMPLE POPULATION: Fifteen pairs of equine third metacarpal (MC3) bones. METHODS: Lateral condylar fractures were simulated by parasagittal osteotomies and repaired pairwise by 2 × 5.5 mm cortical screws of 8 mm (standard) or 10 mm (modified) head diameter. Interfragmentary compression at maximum screw insertion torque was measured. The instrumented specimens were pairwise stratified for biomechanical testing under the following modalities (n = 5): (1) screw insertion torque to failure, (2) quasi-static axial load to failure, and (3) cyclic axial load to 2 mm displacement followed by failure. Tests (1) and (2) were analyzed for yield, maximum, and failure torque/angle and load/displacement, respectively. Number of cycles to 2 mm displacement and failure was assessed from test (3). RESULTS: Maximum insertion torque was greater, and failure angle smaller, when constructs repaired with modified screws were tested (8.1 ± 0.5 vs. 7.4 ± 0.5 Nm; P = .0047 and 550 ± 104 vs. 1130 ± 230; P = .008). Axial yield (7118 ± 707 vs. 5740 ± 2267 N; P = .043) and failure load (12 347 ± 3359 vs. 8695 ± 2277 N; P = .043) were greater for specimens repaired with modified screws. No difference was detected between constructs in the number of cycles to 2 mm displacement. CONCLUSION: Condylar MC3 osteotomies repaired with modified 5.5 mm cortical screws sustained greater maximal hand torque insertion, smaller insertion failure angle and 1.4 fold greater quasi-static failure forces than constructs repaired with standard 5.5 mm screws. CLINICAL SIGNIFICANCE: Use of modified screws with larger heads may improve the fixation of condylar fractures in horses. These results provide evidence to justify clinical evaluation in horses undergoing fracture repair.


Asunto(s)
Fracturas Óseas , Enfermedades de los Caballos , Animales , Fenómenos Biomecánicos , Tornillos Óseos/veterinaria , Cadáver , Fijación de Fractura/veterinaria , Fijación Interna de Fracturas/métodos , Fijación Interna de Fracturas/veterinaria , Fracturas Óseas/cirugía , Fracturas Óseas/veterinaria , Caballos/cirugía , Torque
6.
Arch Orthop Trauma Surg ; 142(6): 1055-1061, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33590315

RESUMEN

INTRODUCTION: The aim of this investigation was to better understand the differences in local bone quality at the distal femur and their correlation with biomechanical construct failure, with the intention to identify regions of importance to optimize implant anchorage. MATERIALS AND METHODS: Seven fresh-frozen female femurs underwent high-resolution peripheral quantitative computed tomography (HR-pQCT) to determine bone mineral density (BMD) within three different regions of interest (distal, intermedium, and proximal) at the distal femur. In addition, local bone quality was assessed by measuring the peak torque necessary to break out the trabecular bone along each separate hole of a locking compression plate (LCP) during its instrumentation. Finally, biomechanical testing was performed using cyclic axial loading until failure in an AO/OTA 33 A3 fracture model. RESULTS: Local BMD was highest in the distal region. This was confirmed by the measurement of local bone quality using DensiProbe™. The most distal holes represented locations with the highest breakaway torque resistance, with the holes on the posterior side of the plate indicating higher values than those on its anterior side. We demonstrated strong correlation between the cycles to failure and local bone strength (measured with DensiProbe™) in the most distal posterior screw hole, having the highest peak torque. CONCLUSION: The local bone quality at the distal femur indicates that in plated distal femur fractures the distal posterior screw holes seem to be the key ones and should be occupied. Measurement of the local bone strength with DensiProbe™ is one possibility to determine the risk of construct failure, therefore, thresholds need to be defined.


Asunto(s)
Fracturas del Fémur , Fijación Interna de Fracturas , Fenómenos Biomecánicos , Placas Óseas , Cadáver , Femenino , Fracturas del Fémur/diagnóstico por imagen , Fracturas del Fémur/cirugía , Fémur/cirugía , Fijación Interna de Fracturas/métodos , Humanos , Indicadores de Calidad de la Atención de Salud
7.
Arch Orthop Trauma Surg ; 142(6): 1031-1037, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33507380

RESUMEN

INTRODUCTION: This study investigated the effects of a small posterior malleolar fragment (PMF), containing less than 25% articular surface area, on ankle joint stability via computed tomography (CT) scanning under full weight bearing in a human cadaveric ankle fracture model. MATERIALS AND METHODS: A trimalleolar fracture with a PMF of less than 25% articular surface area was created in 6 pairs of fresh-frozen human cadaveric lower legs. The specimens were randomized into 2 groups stabilized by internal fixation including a positioning screw for syndesmotic reconstruction. In Group I the PMF was addressed by direct screw osteosynthesis, whereas in Group II the fragment was not fixed. Six predefined distances within the ankle were measured under axial loading. CT scans of each specimen were performed in intact and fixated states in neutral position, dorsiflexion and plantar-flexion of the ankle. RESULTS: In plantar-flexion, significant differences were detected between the groups with regard to rotational instability. Group II demonstrated a significantly increased inward rotation of the fibula compared with Group I. No significant differences were detected between the groups for each one of the measured distances in any of the three foot positions. CONCLUSIONS: Additional reduction and fixation of a small PMF seems to neutralize rotational forces in the ankle more effectively than a sole syndesmotic screw. Clinically, this becomes relevant in certain phases of the gait cycle. Direct screw osteosynthesis of a small PMF stabilizes the ankle more effectively than a positioning screw.


Asunto(s)
Fracturas de Tobillo , Fracturas de Tobillo/diagnóstico por imagen , Fracturas de Tobillo/cirugía , Articulación del Tobillo/cirugía , Tornillos Óseos , Cadáver , Fijación Interna de Fracturas/métodos , Humanos , Estudios Retrospectivos , Resultado del Tratamiento
8.
Arch Orthop Trauma Surg ; 142(12): 3787-3796, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34748055

RESUMEN

BACKGROUND: Recently, two novel concepts for intramedullary nailing of trochanteric fractures using a helical blade or interlocking dual screws have demonstrated advantages as compared to standard single-screw systems. However, these two concepts have not been subjected to a direct biomechanical comparison so far. The aims of this study were to investigate in a human cadaveric model with low bone quality (1) the biomechanical competence of nailing with the use of a helical blade versus interlocking screws, and (2) the effect of cement augmentation on the fixation strength of the helical blade. METHODS: Twelve osteoporotic and osteopenic human cadaveric femoral pairs were assigned for pairwise implantation using either a short TFN-ADVANCED Proximal Femoral Nailing System (TFNA) with a helical blade head element or a short TRIGEN INTERTAN Intertrochanteric Antegrade Nail (InterTAN) with interlocking screws. Six osteoporotic femora, implanted with TFNA, were augmented with bone cement. Four groups were created: group 1 (TFNA) paired with group 2 (InterTAN), both consisting of osteopenic specimens, and group 3 (TFNA augmented) paired with group 4 (InterTAN), both consisting of osteoporotic specimens. An unstable trochanteric AO/OTA 31-A2.2 fracture was simulated and all specimens were tested until failure under progressively increasing cyclic loading. RESULTS: Stiffness in group 3 was significantly higher versus group 4, p = 0.03. Varus (°) and femoral head rotation around the femoral neck axis (°) after 10,000 cycles were 1.9 ± 1.0/0.3 ± 0.2 in group 1, 2.2 ± 0.7/0.7 ± 0.4 in group 2, 1.5 ± 1.3/0.3 ± 0.2 in group 3 and 3.5 ± 2.8/0.9 ± 0.6 in group 4, being significantly different between groups 3 and 4, p = 0.04. Cycles to failure and failure load (N) at 5° varus or 10° femoral head rotation around the neck axis in groups 1-4 were 21,428 ± 6020/1571.4 ± 301.0, 20,611 ± 7453/1530.6 ± 372.7, 21,739 ± 4248/1587.0 ± 212.4 and 18,622 ± 6733/1431.1 ± 336.7, being significantly different between groups 3 and 4, p = 0.04. CONCLUSIONS: Nailing of trochanteric femoral fractures with use of helical blades is comparable to interlocking dual screws fixation in femoral head fragments with low bone quality. Bone cement augmentation of helical blades provides significantly greater fixation strength compared to interlocking screws constructs.


Asunto(s)
Fijación Intramedular de Fracturas , Fracturas de Cadera , Humanos , Tornillos Óseos , Cementos para Huesos , Uñas , Cadáver , Fracturas de Cadera/cirugía , Clavos Ortopédicos , Fenómenos Biomecánicos
9.
Medicina (Kaunas) ; 58(7)2022 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-35888576

RESUMEN

Background and Objectives: Fracture healing is currently assessed through qualitative evaluation of radiographic images, which is highly subjective in nature. Radiographs can only provide snapshots in time, which are limited due to logistics and radiation exposure. We recently proposed assessing the bone healing status through continuous monitoring of the implant load, utilizing an implanted sensor system, the Fracture Monitor. The device telemetrically transmits statistically derived implant parameters via the patient's mobile phone to assist physicians in diagnostics and treatment decision-making. This preclinical study aims to systematically investigate the device safety and performance in an animal setting. Materials and Methods: Mid-shaft tibial osteotomies of different sizes (0.6-30 mm) were created in eleven Swiss mountain sheep. The bones were stabilized with either a conventional Titanium or stainless-steel locking plate equipped with a Fracture Monitor. Data were continuously collected over the device's lifetime. Conventional radiographs and clinical CT scans were taken longitudinally over the study period. The radiographs were systematically scored and CTs were evaluated for normalized bone volume in the defect. The animals were euthanized after 9 months. The sensor output was correlated with the radiologic parameters. Tissue samples from the device location were histologically examined. Results: The sensors functioned autonomously for 6.5-8.4 months until energy depletion. No macroscopic or microscopic adverse effects from device implantation were observed. The relative implant loads at 4 and 8 weeks post-operation correlated significantly with the radiographic scores and with the normalized bone volume metric. Conclusions: Continuous implant load monitoring appears as a relevant approach to support and objectify fracture healing assessments and carries a strong potential to enable patient-tailored rehabilitation in the future.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas , Animales , Curación de Fractura , Osteotomía , Ovinos , Titanio
10.
Mediators Inflamm ; 2021: 8817421, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34924815

RESUMEN

Short-chain fatty acids (SCFAs) produced by the gut microbiota have previously been demonstrated to play a role in numerous chronic inflammatory diseases and to be key mediators in the gut-bone signaling axis. However, the role of SCFAs in bone fracture healing and its impact on systemic inflammation during the regeneration process has not been extensively investigated yet. The aim of this study was to first determine the effects of the SCFA butyrate on key cells involved in fracture healing in vitro, namely, osteoclasts and mesenchymal stromal cells (MSCs), and second, to assess if butyrate supplementation or antibiotic therapy impacts bone healing, systemic immune status, and inflammation levels in a murine osteotomy model. Butyrate significantly reduced osteoclast formation and resorption activity in a dose-dependent manner and displayed a trend for increased calcium deposits in MSC cultures. Numerous genes associated with osteoclast differentiation were differentially expressed in osteoclast precursor cells upon butyrate exposure. In vivo, antibiotic-treated mice showed reduced SCFA levels in the cecum, as well as a distinct gut microbiome composition. Furthermore, circulating proinflammatory TNFα, IL-17a, and IL-17f levels, and bone preserving osteoprotegerin (OPG), were increased in antibiotic-treated mice compared to controls. Antibiotic-treated mice also displayed a trend towards delayed bone healing as revealed by reduced mineral apposition at the defect site and higher circulating levels of the bone turnover marker PINP. Butyrate supplementation resulted in a lower abundance of monocyte/macrophages in the bone marrow, as well as reduced circulating proinflammatory IL-6 levels compared to antibiotic- and control-treated mice. In conclusion, this study supports our hypothesis that SCFAs, in particular butyrate, are important contributors to successful bone healing by modulating key cells involved in fracture healing as well as systemic inflammation and immune responses.


Asunto(s)
Antibacterianos/farmacología , Butiratos/farmacología , Curación de Fractura/efectos de los fármacos , Inflamación/etiología , Osteoclastos/efectos de los fármacos , Animales , Diferenciación Celular/efectos de los fármacos , Células Cultivadas , Citocinas/análisis , Ácidos Grasos Volátiles/farmacología , Curación de Fractura/fisiología , Microbioma Gastrointestinal/efectos de los fármacos , Humanos , Mediadores de Inflamación/análisis , Levofloxacino/farmacología , Masculino , Ratones , Ratones Endogámicos C57BL , Osteoclastos/citología , Osteotomía , Rifampin/farmacología
11.
BMC Musculoskelet Disord ; 22(1): 709, 2021 Aug 18.
Artículo en Inglés | MEDLINE | ID: mdl-34407777

RESUMEN

BACKGROUND: The prediction of the stability of bones is becoming increasingly important. Especially osteoporotic vertebral body fractures are a growing problem and an increasing burden on the health system. Therefore, the aim of this study was to provide the best possible description of the relationship between the material properties of human vertebral trabecular bone measured under the most physiological conditions possible and the bone mineral density (BMD) determined by clinical quantitative computed tomography (QCT). METHODS: Forty eight cylindric cancellous bone samples with a diameter of 7.2 mm obtained from 13 human fresh-frozen lumbar vertebrae from 5 donors (3 men, 2 women) have been used for this study. After the specimens were temporarily reinserted into the vertebral body, the QCT was performed. For mechanical testing, the samples were embedded in a load-free manner using polymethylmetacrylate (PMMA). The surrounding test chamber was filled with phosphate buffered saline (PBS) and heated to 37 °C during the test. After 10 preconditioning load cycles, destructive testing was performed under axial compression. After determining the fracture site, BMD has been evaluated in this region only. Regression analyses have been performed. RESULTS: Fracture site had an average length of 2.4 (±1.4) mm and a position of 43.9 (±10.9) percent of the measurement length from the cranial end. No fracture reached the embedding. The average BMD at the fracture site was 80.2 (±28.7 | min. 14.5 | max. 137.8) mgCaHA/ml. In summary the results of the regression analyses showed for all three parameters a very good quality of fit by a power regression. CONCLUSION: The results of this study show that QCT-based bone density measurements have a good predictive power for the material properties of the vertebral cancellous bone measured under near to physiological conditions. The mechanical bone properties of vertebral cancellous bone could be modelled with high accuracy in the investigated bone density range.


Asunto(s)
Fracturas Osteoporóticas , Fracturas de la Columna Vertebral , Densidad Ósea , Hueso Esponjoso/diagnóstico por imagen , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Fracturas Osteoporóticas/diagnóstico por imagen , Fracturas de la Columna Vertebral/diagnóstico por imagen , Tomografía Computarizada por Rayos X
12.
J Orthop Traumatol ; 22(1): 5, 2021 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-33638741

RESUMEN

BACKGROUND: Given the increasing number of osteoporotic fractures of the distal femur, screw augmentation with bone cement is an option to enhance implant anchorage. However, in implant removal or revision surgeries, the cement cannot be removed from the distal femur without an extended surgical procedure. Therefore, the aims of this study were to investigate (1) whether cement augmentation has any influence on screw removal and removal torque, and (2) whether the implantation of a femoral component of a knee arthroplasty and its initial interface stability are affected by the remaining screws/cement. MATERIAL AND METHODS: Eight pairs of fresh-frozen human female cadaveric distal femurs (mean age, 86 years) with a simulated AO/OTA 33 A3 fracture were randomized in paired fashion to two groups and fixed with a distal femoral locking plate using cannulated perforated locking screws. Screw augmentation with bone cement was performed in one of the groups, while the other group received no screw augmentation. Following biomechanical testing until failure (results published separately), the screws were removed and the removal torque was measured. A femoral component of a knee arthroplasty was then implanted, and pull-out tests were performed after cement curing. Interference from broken screws/cement was assessed, and the maximum pull-out force was measured. RESULTS: The mean screw removal torque was not significantly different between the augmented (4.9 Nm, SD 0.9) and nonaugmented (4.6 Nm, SD 1.3, p = 0.65) screw groups. However, there were significantly more broken screws in in the augmented screw group (17 versus 9; p < 0.001). There was no significant difference in the pull-out force of the femoral component between the augmented (2625 N, SD 603) and nonaugmented (2653 N, SD 542, p = 0.94) screw groups. CONCLUSION: The screw removal torque during implant removal surgery does not significantly differ between augmented and nonaugmented screws. In the augmented screw group, significantly more screws failed. To overcome this, the use of solid screws in holes B, C, and G can be considered. Additionally, it is possible to implant a femoral component for knee arthroplasty that retains the initial anchorage and does not suffer from interference with broken screws and/or residual cement. LEVEL OF EVIDENCE: 5.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Cementos para Huesos , Tornillos Óseos , Remoción de Dispositivos/métodos , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/métodos , Anciano de 80 o más Años , Fenómenos Biomecánicos , Placas Óseas , Cadáver , Femenino , Fracturas del Fémur/fisiopatología , Humanos , Reoperación
13.
BMC Musculoskelet Disord ; 21(1): 151, 2020 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-32143605

RESUMEN

BACKGROUND: In osteoporotic bone, the quality of the bone-to-implant interface is decreased, which may lead to early implant failure. Screw anchorage can be improved by augmentation. This effect is mainly investigated with a pull-out test. To our knowledge, the effect of cement augmentation in an in vivo physiological setup focusing on screw movement has not been investigated to date. The aim of this work was to investigate and compare augmented and native screw behavior in a physiologically related setup. METHODS: Twelve fresh-frozen human lumbar vertebrae were divided into two groups. Each vertebra was bilaterally instrumented with either non-augmented or augmented pedicle screw systems and loaded in a recently developed test setup that provided cyclic conditions comparable to a physiological gait. The cyclic loading should test the primary implant stability, comparable to the postoperative period of two months in a worst-case scenario in the absence of osseous remodeling. Screws were tracked optically, and screw movement and failure patterns were observed. RESULTS: Mutual influence between the left and right sides resulted in a successive, rather than simultaneous, failure. Augmentation of the screws in vertebrae with poor bone quality reduced screw subsidence and thus improved the rigidity of the screw-to-implant interface by up to six-fold. The non-augmented condition was significantly related to early screw failure. CONCLUSIONS: Pedicle screw system failure involves a complex bilateral-coupled mechanism. The cyclic loading based on physiological conditions during walking has allowed the postoperative conditions and clinical failure mechanisms to be simulated in vitro and clarified. Future implant systems should be investigated with a physiologically related setup.


Asunto(s)
Densidad Ósea , Vértebras Lumbares/fisiología , Vértebras Lumbares/cirugía , Ensayo de Materiales/métodos , Tornillos Pediculares , Fusión Vertebral/métodos , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Cementos para Huesos , Prótesis Anclada al Hueso , Interfase Hueso-Implante , Humanos , Persona de Mediana Edad , Osteoporosis/cirugía , Polimetil Metacrilato , Falla de Prótesis , Soporte de Peso
14.
Clin Anat ; 32(3): 361-368, 2019 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-30521090

RESUMEN

Distal radius fractures are common and fracture patterns and fixation can be complex. Computerized anatomy evaluation (CAE) might offer non-invasive and enhanced anatomy assessment that might help with implant selection and placement and screw length determination. Our goal was to test the accuracy of two CAE methods for anatomical volar plate positioning and screw lengths measurement of the distal radius. We included 56 high-resolution peripheral quantitative computed tomography scans of intact, human distal radii. Plates were placed manually onto 3D printed models (method 1), which was compared with automated computerized plate placement onto the 3D computer models (method 2). Subsequently, screw lengths were determined digitally for both methods. Screw lengths evaluations were compared via Bland-Altman plots. Both CAE methods resulted in identical volar plate selection and in anatomical plate positioning. For screw length the concordance correlation coefficient was ≥0.91, the location shift ≤0.22 mm, and the scale shift ≤0.16. The differences were smaller than ±1 mm in all samples. Both CAE methods allow for comparable plate positioning and subsequent screw length measurement in distal radius volar plating. Both can be used as a non-invasive teaching environment for volar plate fixation. Method 2 even offers fully computerized assessments. Future studies could compare our models to other anatomical areas, post-operative volar plate positioning, and model performance in actual distal radius fracture instead of intact radii. Clin. Anat. 32:361-368, 2019. © 2018 The Authors. Clinical Anatomy published by Wiley Periodicals, Inc. on behalf of American Association of Clinical Anatomists.


Asunto(s)
Fracturas del Radio/diagnóstico por imagen , Radio (Anatomía)/anatomía & histología , Placas Óseas , Tornillos Óseos , Cadáver , Fijación Interna de Fracturas/métodos , Humanos , Imagenología Tridimensional , Procedimientos Ortopédicos/educación , Radio (Anatomía)/diagnóstico por imagen , Fracturas del Radio/cirugía , Tomografía Computarizada por Rayos X
15.
Biomed Eng Online ; 17(1): 29, 2018 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-29495963

RESUMEN

BACKGROUND: The present study contrasts the accuracy of different reconstructed models with distinctive segmentation methods performed by various experts. Seven research groups reconstructed nine 3D models of one human femur based on an acquired CT image using their own computational methods. As a reference model for accuracy assessment, a 3D surface scan of the human femur was created using an optical measuring system. Prior to comparison, the femur was divided into four areas; "neck and greater trochanter", "proximal metaphysis", "diaphysis", and "distal metaphysis". The deviation analysis was carried out in GEOMAGIC studio v.2013 software. RESULTS: The results revealed that the highest deviation errors occurred in "neck and greater trochanter" area and "proximal metaphysis" area with RMSE of 0.84 and 0.83 mm respectively. CONCLUSION: In conclusion, this study shows that the average deviation of reconstructed models prepared by experts with various methods, skills and software from the surface 3D scan is lower than 0.79 mm, which is not a significant discrepancy.


Asunto(s)
Fémur/diagnóstico por imagen , Imagenología Tridimensional , Laboratorios , Fenómenos Ópticos , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/normas , Humanos , Persona de Mediana Edad , Estándares de Referencia
16.
Arch Orthop Trauma Surg ; 137(1): 63-71, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28005168

RESUMEN

INTRODUCTION: The high rigidity of metal implants may be a cause of failure after fixation of proximal humerus fractures. Carbon fiber-reinforced polyetheretherketone (PEEK) plates with a modulus similar to human cortical bone may help to overcome this problem. The present study assesses the biomechanical behavior of a PEEK plate compared with a titanium locking plate. MATERIALS AND METHODS: Unstable two- and three-part fractures were simulated in 12 pairs of cadaveric humeri and were fixed with either a PEEK or a titanium locking plate using a pairwise comparison. With an optical motion capture system, the stiffness, failure load, plate bending, and the relative motion at the bone-implant interface and at the fracture site were evaluated. RESULTS: The mean load to failure for two- and three-part fracture fixations was, respectively, 191 N (range 102-356 N) and 142 N (range 102-169 N) in the PEEK plate group compared with 286 N (range 191-395 N) and 258 N (range 155-366 N) in the titanium locking plate group. The PEEK plate showed significantly more bending in both the two- and three-part fractures (p < 0.05), an increased relative motion at the bone-implant interface and lower stiffness values (p < 0.05). CONCLUSION: In this biomechanical study on unstable proximal humerus fractures, fixation with a PEEK plate showed lower fixation strength and increased motion at the bone-implant interface compared with a titanium locking plate.


Asunto(s)
Materiales Biocompatibles , Placas Óseas , Fijación Interna de Fracturas/instrumentación , Cetonas , Polietilenglicoles , Fracturas del Hombro/cirugía , Titanio , Anciano , Anciano de 80 o más Años , Benzofenonas , Fenómenos Biomecánicos , Cadáver , Carbono , Fibra de Carbono , Femenino , Humanos , Masculino , Polímeros , Estrés Mecánico
17.
BMC Musculoskelet Disord ; 17: 318, 2016 07 29.
Artículo en Inglés | MEDLINE | ID: mdl-27472925

RESUMEN

BACKGROUND: Tibiotalocalcaneal arthrodesis (TTCA) using intramedullary nails is a salvage procedure for many diseases in the ankle and subtalar joint. Despite "newly described intramedullary nails" with specific anatomical shapes there still remain major complications regarding this procedure. The following study presents a modified biomechanical test setup for investigations of the hindfoot. METHODS: Nine fresh-frozen specimens from below the human knee were anaysed using the Hindfoot Arthrodesis Nail (Synthes) instrument. Quasi-static biomechanical testing was performed for internal/external rotation, varus/valgus and dorsal/plantar flexion using a modified established setup (physiological load entrance point, sledge at lever arm to apply pure moments). Additionally, a 3D optical measurement system was added to allow determination of interbony movements. RESULTS: The mean torsional range of motion (ROM) calculated from the actuator data of a material testing machine was 10.12° (SD 0.6) compared to 10° (SD 2.83) as measured with the Optotrak® system (between tibia and calcaneus). The Optotrak showed 40 % more rotation in the talocrural joint. Mean varus/valgus ROM from the material testing flexion machine was seen to be 5.65° (SD 1.84) in comparison to 2.82° (SD 0.46) measured with the Optotrak. The subtalar joint showed a 70 % higher movement when compared to the talocrural joint. Mean ROM in the flexion test was 5.3° (SD 1.45) for the material testing machine and 2.1° (SD 0.39) for the Optotrak. The movement in the talocrural joint was 3 times higher compared to the subtalar joint. CONCLUSION: The modified test setup presented here for the hindfoot allows a physiological biomechanical loading. Moreover, a detailed characterisation of the bone-implant constructs is possible.


Asunto(s)
Articulación del Tobillo/fisiopatología , Artrodesis/instrumentación , Clavos Ortopédicos , Ensayo de Materiales/métodos , Rango del Movimiento Articular , Articulación Talocalcánea/fisiopatología , Anciano , Anciano de 80 o más Años , Articulación del Tobillo/cirugía , Artrodesis/efectos adversos , Artrodesis/métodos , Fenómenos Biomecánicos , Calcáneo/cirugía , Femenino , Pie/cirugía , Humanos , Imagenología Tridimensional , Masculino , Ensayo de Materiales/instrumentación , Rotación , Articulación Talocalcánea/cirugía , Astrágalo/cirugía , Tibia/cirugía
18.
Eur Spine J ; 23(11): 2321-9, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25155837

RESUMEN

PURPOSE: Purpose of this paper is to evaluate the primary stability of a new approach for facet fixation the so-called Facet Wedge (FW) in comparison with established posterior fixation techniques like pedicle screws (PS) and translaminar facet screws (TLS) with and without anterior cage interposition. METHODS: Twenty-four monosegmental fresh frozen non-osteoporotic human motion segments (L2-L3 and L4-L5) were tested in a two-arm biomechanical study using a robot-based spine tester. Facet Wedge was compared with pedicle screws and translaminar screws as a stand-alone device and in combination with an anterior fusion cage. RESULTS: Pedicle screws, FW and translaminar screws could stabilize an intact motion segment effectively. Facet Wedge was comparable to PS for lateral bending, extension and flexion and slightly superior for axial rotation. Facet Wedge showed a superior kinematic capacity compared to translaminar screws. CONCLUSIONS: Facet Wedge offers a novel posterior approach in achieving primary stability in lumbar spinal fixation. The results of the present study showed that the Facet Wedge has a comparable primary stability to pedicle screws and potential advantages over translaminar screws.


Asunto(s)
Fijadores Internos , Vértebras Lumbares/cirugía , Ensayo de Materiales , Articulación Cigapofisaria/cirugía , Fenómenos Biomecánicos , Tornillos Óseos , Cadáver , Fluoroscopía , Humanos , Vértebras Lumbares/diagnóstico por imagen , Persona de Mediana Edad , Robótica , Articulación Cigapofisaria/diagnóstico por imagen
19.
ACS Biomater Sci Eng ; 10(7): 4575-4586, 2024 Jul 08.
Artículo en Inglés | MEDLINE | ID: mdl-38839046

RESUMEN

Vertebroplasty is a minimally invasive surgical procedure used to treat vertebral fractures, which conventionally involves injecting poly(methyl methacrylate) (PMMA) bone cement into the fractured vertebra. A common risk associated with vertebroplasty is cement leaking out of the vertebra during the injection, which may occur due to a lack of understanding of the complex flow behavior. Therefore, experiments to quantify the cement's flow properties are necessary for understanding and proper handling of the bone cement. In this study, we aimed to characterize the behavior of PMMA bone cement in its curing stages to obtain parameters that govern the flow behavior during injection. We used rotational and oscillatory rheometry for our measurements, as well as a custom-made injector setup that replicated a typical vertebroplasty setting. Our results showed that the complex viscoelastic behavior of bone cement is significantly affected by deformations and temperature. We found that the results from rotational tests, often used for characterizing the bone cement, are susceptible to measurement artifacts caused by wall slip and "ridge"-like formations in the test sample. We also found the Cox-Merz rule to be conditionally valid, which affects the use of oscillatory tests to obtain the shear-thinning characteristics of bone cement. Our findings identify important differences in the measured flow behavior of PMMA bone cement when assessed by different rheological methods, an understanding that is crucial for its risk-free usage in downstream medical applications.


Asunto(s)
Cementos para Huesos , Polimetil Metacrilato , Reología , Vertebroplastia , Polimetil Metacrilato/química , Cementos para Huesos/química , Vertebroplastia/métodos , Ensayo de Materiales/métodos , Viscosidad , Humanos , Temperatura
20.
BMC Musculoskelet Disord ; 14: 360, 2013 Dec 21.
Artículo en Inglés | MEDLINE | ID: mdl-24359173

RESUMEN

BACKGROUND: Treating traumatic fractures in osteoporosis is challenging. Multiple clinical treatment options are found in literature. Augmentation techniques are promising to reduce treatment-related morbidity. In recent years, there have been an increasing number of reports about extended indication for augmentation techniques. However, biomechanical evaluations of these techniques are limited. METHODS: Nine thoracolumbar osteoporotic spinal samples (4 FSU) were harvested from postmortem donors and immediately frozen. Biomechanical testing was performed by a robotic-based spine tester. Standardized incomplete burst fractures were created by a combination of osteotomy-like weakening and high velocity compression using a hydraulic material testing apparatus. Biomechanical measurements were performed on specimens in the following conditions: 1) intact, 2) fractured, 3) bisegmental instrumented, 4) bisegmental instrumented with vertebroplasty (hybrid augmentation, HA) and 5) stand-alone vertebroplasty (VP). The range of motion (RoM), neutral zone (NZ), elastic zone (EZ) and stiffness parameters were determined. Statistical evaluation was performed using Wilcoxon signed-rank test for paired samples (p = 0.05). RESULTS: Significant increases in RoM and in the NZ and EZ (p < 0.005) were observed after fracture production. The RoM was decreased significantly by applying the dorsal bisegmental instrumentation to the fractured specimens (p < 0.005). VP reduced fractured RoM in flexion but was still increased significantly (p < 0.05) above intact kinematic values. NZ stiffness (p < 0.05) and EZ stiffness (p < 0.01) was increased by VP but remained lower than prefracture values. The combination of short segment instrumentation and vertebroplasty (HA) showed no significant changes in RoM and stiffness in NZ in comparison to the instrumented group, except for significant increase of EZ stiffness in flexion (p < 0.05). CONCLUSIONS: Stand-alone vertebroplasty (VP) showed some degree of support of the anterior column but was accompanied by persistent traumatic instability. Therefore, we would advocate against using VP as a stand-alone procedure in traumatic fractures. HA did not increase primary stability of short segment instrumentation. Some additional support of anterior column and changes of kinematic values of the EZ may lead one to suppose that additive augmentation may reduce the load of dorsal implants and possibly reduce the risk of implant failure.


Asunto(s)
Osteoporosis/complicaciones , Fracturas de la Columna Vertebral/cirugía , Columna Vertebral/fisiología , Vertebroplastia , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Fracturas de la Columna Vertebral/etiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA