Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Biosens Bioelectron ; 22(7): 1303-10, 2007 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-16860556

RESUMEN

In this paper we describe a new approach to measure pH differences in microfluidic devices and demonstrated acidification rate measurements in on-chip cell culture systems with nl wells. We use two miniaturized identical iridium oxide (IrOx) thin film electrodes (20 micromx400 microm), one as a quasi-reference electrode, the other as a sensing electrode, placed in two confluent compartments on chip. The IrOx electrodes were deposited onto microfabricated platinum (Pt) electrodes simultaneously using electrodeposition. Incorporating the electrodes into a microfluidic device allowed us to expose each electrode to a different solution with a pH difference of one pH unit maintaining a confluent connection between the electrodes. In this configuration, we obtained a reproducible voltage difference between the two IrOx thin film electrodes, which corresponds to the electrode sensitivities of -70 mV/pH at 22 degrees C. In order to measure the acidification rate of cells in nl cell culture volumes we placed one IrOx thin film electrode in the perfusion channel as a quasi-reference electrode and the other in the cell culture volume. We obtained an acidification rate of 0.19+/-0.02 pH/min for fibroblast cells using a stop flow protocol. These results show that we can use two identical miniaturized microfabricated IrOx electrodes to measure pH differences to monitor the metabolic activity of cell cultures on chip. Furthermore, our approach can also be applied in biosensor or bioanalytical applications.


Asunto(s)
Técnicas Biosensibles/instrumentación , Fibroblastos/metabolismo , Iridio , Metabolismo , Nanotecnología , Animales , Línea Celular , Electrodos , Concentración de Iones de Hidrógeno , Ratones
2.
Biosens Bioelectron ; 21(2): 248-56, 2005 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-16023951

RESUMEN

Microsensors are valuable tools to monitor cell metabolism in cell culture volumes. The present research describes the fabrication and characterization of on-chip thin-film iridium oxide pH microsensors with dimensions of 20 microm x 20 microm and 20 microm x 40 microm suitable to be incorporated into nl volumes. IrOx thin films were formed on platinum microelectrodes by electrochemical deposition in galvanostatic mode. Anodically grown iridium oxide films showed a near super-Nernstian response with a slope of -77.6+/-2 mV/pH at 22 degrees C, and linear responses within the pH range of 4-11. Freshly deposited electrodes showed response times as low as 6s. Long-term studies showed a baseline drift of 2-3 mV/month, which could easily be compensated by calibration. This work demonstrated for the first time the use of planar IrOx pH microelectrodes to measure the acidification rate of CHO and fibroblast cells in an on chip cell culture volume of 25 nl with microfluidic control.


Asunto(s)
Técnicas de Cultivo de Célula/instrumentación , Fibroblastos/química , Concentración de Iones de Hidrógeno , Electrodos de Iones Selectos , Iridio/química , Microelectrodos , Técnicas Analíticas Microfluídicas/instrumentación , Animales , Células CHO , Técnicas de Cultivo de Célula/métodos , Células Cultivadas , Cricetinae , Cricetulus , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Iridio/análisis , Membranas Artificiales , Técnicas Analíticas Microfluídicas/métodos , Miniaturización
3.
Lab Chip ; 4(4): 357-62, 2004 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-15269804

RESUMEN

A hybrid chip is described which combines a microfluidic network fabricated in a silicone elastomer (PDMS) with planar microelectrodes. It was used to measure extracellular potentials from single adult murine cardiac myocytes in a restricted extracellular space. The recorded variations in the extracellular potentials were caused by transmembrane currents associated with spontaneously initiated intracellular calcium waves. Single cells were trapped inside the 100 pl microchamber by pressure gradients and maintained for several hours by continuous perfusion. In addition, the localized delivery of drugs to a portion of the cell was demonstrated. The impedance of the electrodes was reduced by a factor of 10 to 20 after the electrodeposition of platinum black. Biopotentials recorded from single cells with platinum black electrodes showed a three-fold decrease in the noise, resulting in a maximum signal-to-noise ratio of 15:1. Characteristic variations in the frequency and shape of the extracellular potentials were observed among different cells which are most likely due to differences in the sarcoplasmic reticulum Ca(2+) load. Our device architecture permits the integration of electrochemical and optical sensors for multiparameter recordings.


Asunto(s)
Espacio Extracelular/fisiología , Potenciales de la Membrana/fisiología , Microfluídica/métodos , Miocitos Cardíacos/citología , Miocitos Cardíacos/fisiología , Nanotecnología/métodos , Animales , Dimetilpolisiloxanos/química , Espacio Extracelular/química , Ratones , Microelectrodos , Microfluídica/instrumentación , Polímeros/química , Siliconas/química
4.
FEBS Lett ; 588(21): 3878-85, 2014 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-25217832

RESUMEN

CYP51 (sterol 14α-demethylase) is an efficient target for clinical and agricultural antifungals and an emerging target for treatment of Chagas disease, the infection that is caused by multiple strains of a protozoan pathogen Trypanosoma cruzi. Here, we analyze CYP51A from the Y strain T. cruzi. In this protein, proline 355, a residue highly conserved across the CYP51 family, is replaced with serine. The purified enzyme retains its catalytic activity, yet has been found less susceptible to inhibition. These biochemical data are consistent with cellular experiments, both in insect and human stages of the pathogen. Comparative structural analysis of CYP51 complexes with VNI and two derivatives suggests that broad-spectrum CYP51 inhibitors are likely to be preferable as antichagasic drug candidates.


Asunto(s)
Inhibidores de 14 alfa Desmetilasa/farmacología , Sistema Enzimático del Citocromo P-450/química , Sistema Enzimático del Citocromo P-450/metabolismo , Trypanosoma cruzi/enzimología , Inhibidores de 14 alfa Desmetilasa/uso terapéutico , Secuencia de Aminoácidos , Sustitución de Aminoácidos , Animales , Biocatálisis , Enfermedad de Chagas/tratamiento farmacológico , Enfermedad de Chagas/enzimología , Secuencia Conservada , Sistema Enzimático del Citocromo P-450/genética , Humanos , Modelos Moleculares , Datos de Secuencia Molecular , Conformación Proteica , Trypanosoma cruzi/efectos de los fármacos
5.
Lab Chip ; 13(23): 4663-73, 2013 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-24126415

RESUMEN

Release of neurotransmitters and hormones by calcium-regulated exocytosis is a fundamental cellular process that is disrupted in a variety of psychiatric, neurological, and endocrine disorders. As such, there is significant interest in targeting neurosecretion for drug and therapeutic development, efforts that will be aided by novel analytical tools and devices that provide mechanistic insight coupled with increased experimental throughput. Here, we report a simple, inexpensive, reusable, microfluidic device designed to analyze catecholamine secretion from small populations of adrenal chromaffin cells in real time, an important neuroendocrine component of the sympathetic nervous system and versatile neurosecretory model. The device is fabricated by replica molding of polydimethylsiloxane (PDMS) using patterned photoresist on silicon wafer as the master. Microfluidic inlet channels lead to an array of U-shaped "cell traps", each capable of immobilizing single or small groups of chromaffin cells. The bottom of the device is a glass slide with patterned thin film platinum electrodes used for electrochemical detection of catecholamines in real time. We demonstrate reliable loading of the device with small populations of chromaffin cells, and perfusion/repetitive stimulation with physiologically relevant secretagogues (carbachol, PACAP, KCl) using the microfluidic network. Evoked catecholamine secretion was reproducible over multiple rounds of stimulation, and graded as expected to different concentrations of secretagogue or removal of extracellular calcium. Overall, we show this microfluidic device can be used to implement complex stimulation paradigms and analyze the amount and kinetics of catecholamine secretion from small populations of neuroendocrine cells in real time.


Asunto(s)
Catecolaminas/análisis , Células Cromafines/metabolismo , Cromatografía Líquida de Alta Presión , Técnicas Electroquímicas , Técnicas Analíticas Microfluídicas/instrumentación , Animales , Calcio/metabolismo , Carbacol/farmacología , Catecolaminas/metabolismo , Bovinos , Células Cultivadas , Células Cromafines/citología , Células Cromafines/efectos de los fármacos , Dimetilpolisiloxanos , Electrodos , Cinética , Polipéptido Hipofisario Activador de la Adenilato-Ciclasa/farmacología , Platino (Metal)/química , Cloruro de Potasio/farmacología , Silicio/química , Estimulación Química
6.
Biosens Bioelectron ; 34(1): 30-6, 2012 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-22398270

RESUMEN

Release of neurotransmitters and hormones by calcium regulated exocytosis is a fundamental cellular/molecular process that is disrupted in a variety of psychiatric, neurological, and endocrine disorders. Therefore, this area represents a relevant target for drug and therapeutic development, efforts that will be aided by novel analytical tools and devices that provide mechanistically rich data with increased throughput. Toward this goal, we have electrochemically deposited iridium oxide (IrOx) films onto planar thin film platinum electrodes (20 µm×300 µm) and utilized these for quantitative detection of catecholamine release from adrenal chromaffin cells trapped in a microfluidic network. The IrOx electrodes show a linear response to norepinephrine in the range of 0-400 µM, with a sensitivity of 23.1±0.5 mA/M mm(2). The sensitivity of the IrOx electrodes does not change in the presence of ascorbic acid, a substance commonly found in biological samples. A replica molded polydimethylsiloxane (PDMS) microfluidic device with nanoliter sensing volumes was aligned and sealed to a glass substrate with the sensing electrodes. Small populations of chromaffin cells were trapped in the microfluidic device and stimulated by rapid perfusion with high potassium (50mM) containing Tyrode's solution at a flow rate of 1 nL/s. Stimulation of the cells produced a rapid increase in current due to oxidation of the released catecholamines, with an estimated maximum concentration in the cell culture volume of ~52 µM. Thus, we demonstrate the utility of an integrated microfluidic network with IrOx electrodes for real-time quantitative detection of catecholamines released from small populations of chromaffin cells.


Asunto(s)
Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Catecolaminas/análisis , Técnicas Electroquímicas/métodos , Microfluídica , Técnicas Biosensibles/instrumentación , Células Cromafines/química , Diseño de Equipo , Exocitosis , Humanos , Iridio/química , Luminiscencia , Microelectrodos , Trombina/análisis
7.
Biosens Bioelectron ; 25(5): 1019-24, 2010 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-19833499

RESUMEN

Monitoring the metabolic activity of cells in automated culture systems is one of the key features of micro-total-analysis-systems. We have developed a microfluidic device that allows us to trap single cardiac myocytes (SCMs) in sub-nanoliter volumes and incorporate amperometric glucose-sensing electrodes with working areas of 0.002 mm(2) to measure the glucose consumption of SCM. The miniaturized planar glucose electrodes were fabricated by spin coating platinum electrodes on glass substrates with a glutaraldehyde/enzyme solution and a protective Nafion membrane. The glucose electrodes demonstrate a high enzymatic activity characterized by an apparent Michaelis-Menten constant of 7.52+/-0.18 mM and a sensitivity of approximately 33.8 and approximately 13.2 mA/Mcm(2) at glucose concentration from 0-6 to 6-20 mM in Tyrode's solution, respectively. The response time of the glucose electrodes was between 5 and 15s, and the sensitivity of the electrodes did not degrade over a period of 8 weeks. A replica molded polydimethylsiloxane microfluidic device with a sub-nanoliter sensing volume was sealed to the glass substrate and aligned with the glucose microelectrodes. SCM can be trapped in the sensing volume above the glucose electrodes to measure the glucose consumption over time. The average glucose consumption of SCM was 0.211+/-0.097 mM/min (n=7) in Tyrode's solution with 5 mM of glucose.


Asunto(s)
Técnicas Biosensibles/instrumentación , Separación Celular/instrumentación , Electroquímica/instrumentación , Electrodos , Glucosa Oxidasa/química , Glucosa/metabolismo , Miocitos Cardíacos/fisiología , Técnicas de Cultivo de Célula/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Técnicas Analíticas Microfluídicas/instrumentación , Nanotecnología/instrumentación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Biosens Bioelectron ; 26(2): 828-33, 2010 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-20566279

RESUMEN

Monitoring the degree of anaerobic respiration of cells in high density microscale culture systems is an enabling key technology and essential for cell-based biosensors. We have fabricated and incorporated miniature amperometric lactate sensing electrodes with working areas from 3 to 5×10(-2) mm2 into a microfluidic-based microscale cell culture system to measure the lactate production rate of fibroblasts in nanoliter volumes. Planar thin film platinum electrode arrays on glass substrates were spin coated with lactate oxidase and a protective Nafion layer. The lactate electrodes had a high enzymatic activity described by a Michaelis-Menten constant of 2.6±0.1 mM, a linear response in the range 0.01-2.5 mM and a sensitivity of 7.3×10(-2) mA/mM cm2. A replica-molded polydimethylsiloxane (PDMS) microfluidic device with nanoliter sensing volumes was aligned and sealed to a glass substrate with the sensing electrodes. We trapped fibroblasts in the cell culture volume and measured the lactate production rate using a stop-flow protocol. The average lactate production rate was 0.011±0.0049 mM/min. The lactate production was suppressed with the addition of 2-deoxy-D-glucose, which binds to hexokinase. The blocking of hexokinase prevents the generation of pyruvate, the intermittent substrate required for lactate production even in the presence of glucose.


Asunto(s)
Técnicas Biosensibles/instrumentación , Conductometría/instrumentación , Fibroblastos/metabolismo , Ácido Láctico/metabolismo , Microelectrodos , Técnicas Analíticas Microfluídicas/instrumentación , Oxigenasas de Función Mixta/química , Animales , Técnicas de Cultivo de Célula/instrumentación , Línea Celular , Enzimas Inmovilizadas/química , Diseño de Equipo , Análisis de Falla de Equipo , Tasa de Depuración Metabólica , Ratones
9.
Biomed Microdevices ; 10(3): 347-54, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18214684

RESUMEN

The metabolic activity of cells can be monitored by measuring the pH in the extracellular environment. Microfabrication and microfluidic technologies allow the sensor size and the extracellular volumes to be comparable to single cells. A glass substrate with thin film pH sensitive IrO( x ) electrodes was sealed to a replica-molded polydimethylsiloxane (PDMS) microfluidic network with integrated valves. The device, termed NanoPhysiometer, allows the trapping of single cardiac myocytes and the measurement of the pH in a detection volume of 0.36 nL. For wild-type (WT) single cardiac myocytes an acidification rate of 6.45 +/- 0.38 mpH/min was measured in comparison to 19.5 +/- 0.38 mpH/min for very long chain Acyl-CoA dehydrogenase (VLCAD) deficient mice in 0.8 mM of Ca(2+). VLCAD deficiency is a fatty acid oxidation disease leading to cardiomyopathy and arrhythmias. The acidification rate increased to 11.96 +/- 1.33 mpH/min for WT and to 32.0 +/- 4.64 mpH/min for VLCAD -/- in 1.8 mM of Ca(2+). The NanoPhysiometer concept can be extended to study ischemia/reperfusion injury or disorders of other biological systems to identify strategies for treatment and possible pharmacological targets.


Asunto(s)
Separación Celular/instrumentación , Electroquímica/instrumentación , Concentración de Iones de Hidrógeno , Electrodos de Iones Selectos , Técnicas Analíticas Microfluídicas/instrumentación , Miocitos Cardíacos/química , Nanotecnología/instrumentación , Animales , Técnicas de Cultivo de Célula/instrumentación , Técnicas de Cultivo de Célula/métodos , Separación Celular/métodos , Células Cultivadas , Electroquímica/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Ratones , Microquímica/instrumentación , Microquímica/métodos , Técnicas Analíticas Microfluídicas/métodos , Miocitos Cardíacos/metabolismo , Nanotecnología/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA