Radiol Med ; 125(6): 561-568, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32067164

RESUMEN

PURPOSE: Left ventricular assist device (LVAD) is considered a standard care for patients with advanced heart failure. The aim of this work was to study in vitro the effects of direct exposure of the Jarvik 2000 LVAD to 10-MV photon beams. METHODS: Jarvik 2000 pump was immersed in a siliconized box filled with deionized water. A 30 × 30 × 15 cm RW3 slabs were added forth and back to the box. A treatment plan consisting of a single direct 10 × 10 cm2 field size beam was used to deliver 1000 MU at the center of the pump. During irradiation, the external Flow Maker controller and the lithium battery were positioned away from the beam. Pump parameter data (included voltage, current and frequency) were measured, recorded and analyzed for changes in pump function among baseline, pre-irradiation, during irradiation, post-irradiation and after 6 months. The whole session lasted 6 months. The Mann-Whitney U test was used to compare the repeated measurements. X-ray radiation attenuation was also studied. RESULTS: The parameters investigated remained stable over the 6 months; that is, no pump stops, alarms, events, operational changes or abnormalities during the discharge rate of the connected power sources, were encountered, confirmed by the Mann-Whitney U test applied to all sessions (p > 0.1). The measured X-ray attenuation differed from the calculated one by TPS by 34%. CONCLUSION: The Jarvik 2000 resulted stable under direct X-ray beam of 10-MV energy. Its strong attenuation, however, can affect dose deposition in the pump in TPS, and it must be taken into account.


Asunto(s)
Corazón Auxiliar , Fotones/uso terapéutico , Radioterapia/métodos
2.
J Appl Clin Med Phys ; 19(1): 86-93, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29125239

RESUMEN

Volumetric Modulated Arc Therapy (VMAT) techniques for fractioned stereotactic brain radiotherapy (FSBRT) can achieve highly conformal dose distribution to intracranial lesions. However, they can potentially increase the dose to hippocampus (H) causing neurocognitive toxicity during the first four months after irradiation. The purpose of this study was to assess the feasibility of hippocampal-sparing (HS) treatment plans in 22 patients with brain metastasis treated with VMAT technique. Firstly, we retrospectively analyzed hippocampal doses in all 22 VMAT original (not hippocampal-sparing, NHS) plans. Plans with hippocampal dose exceeding constraints (9 out of 22) were re-planned considering dose constraints on the hippocampus (H) and on hippocampal avoidance zone (HAZ) generated using 5 mm isotropic margin to the hippocampus. Conformity (CI) and homogeneity indexes (HI) on the target and MUs, were maintained as close as possible to the original plans. Mean CINHS and CIHS obtained were: 0.79 ± 0.11 and 0.81 ± 0.10, respectively (P = 0.75); mean HINHS and HIHS were 1.05 ± 0.02 and 1.04 ± 0.01 respectively (P = 0.72). In both sets of plans, the mean MU values were similar: 1033 ± 275 and 1022 ± 234 for NHS and HS respectively. In HS plans, the mean hippocampal dose was decreased by an average of 35%. After replanning, the Dmax (21.3 Gy) for HAZ and H was met by 45% (4/9) and 78% (7/9) of the NHS plans, respectively. The worst results were obtained for cases with target volumes extention closer than 12 mm to H, because of the difficulty to spare hippocampus without compromising target coverage. After replanning D40% constraint value (7.3 Gy) was met by all the 9 NHS plans. In conclusion, this study suggests that an hippocampal-sparing approach to FSBRT is feasible resulting in a decrease in the dose to the hippocampus without any loss in conformity or increase in treatment time.


Asunto(s)
Neoplasias Encefálicas/cirugía , Hipocampo/efectos de la radiación , Tratamientos Conservadores del Órgano/métodos , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Anciano , Anciano de 80 o más Años , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/secundario , Estudios de Factibilidad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Órganos en Riesgo/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos
3.
Technol Cancer Res Treat ; 17: 1533033818779201, 2018 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-29871570

RESUMEN

PURPOSE: The aim of the in vivo dosimetry, during the fractionated radiation therapy, is the verification of the correct dose delivery to patient. Nowadays, in vivo dosimetry procedures for photon beams are based on the use of the electronic portal imaging device and dedicated software to elaborate electronic portal imaging device images. METHODS: In total, 8474 in vivo dosimetry tests were carried out for 386 patients treated with 3-dimensional conformal radiotherapy, intensity-modulated radiotherapy, and volumetric modulated arc therapy techniques, using the SOFTDISO. SOFTDISO is a dedicated software that uses electronic portal imaging device images in order to (1) calculate the R index, that is, the ratio between daily reconstructed dose and the planned one at isocenter and (2) perform a γ-like analysis between the signals, S, of a reference electronic portal imaging device image and that obtained in a daily fraction. It supplies 2 indexes, the percentage γ% of points with γ < 1 and the mean γ value, γmean. In γ-like analysis, the pass criteria for the signals agreement ΔS% and distance to agreement Δd have been selected based on the clinical experience and technology used. The adopted tolerance levels for the 3 indexes were fixed in 0.95 ≤ R ≤ 1.05, γ% ≥ 90%, and γmean ≤ 0.5. RESULTS: The results of R ratio, γ-like, and a visual inspection of these data reported on a monitor screen permitted to individuate 2 classes of errors (1) class 1 that included errors due to inadequate standard quality controls and (2) class 2, due to patient morphological changes. Depending on the technique and anatomical site, a maximum of 18% of tests had at least 1 index out of tolerance; once removed the causes of class-1 errors, almost all patients (except patients with 4 lung and 2 breast cancer treated with 3-dimensional conformal radiotherapy) presented mean indexes values ([Formula: see text], [Formula: see text]%, and [Formula: see text] ) within tolerance at the end of treatment course. Class-2 errors were found in some patients. CONCLUSIONS: The in vivo dosimetry procedure with SOFTDISO resulted easily implementable, able to individuate errors with a limited workload.


Asunto(s)
Dosimetría in Vivo/métodos , Neoplasias/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Programas Informáticos , Estudios de Factibilidad , Humanos , Dosificación Radioterapéutica , Radioterapia Conformacional/métodos , Radioterapia de Intensidad Modulada/métodos