Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 82
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Radiographics ; 42(4): 947-967, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35657766

RESUMEN

Coronary artery calcium (CAC) scores obtained from CT scans have been shown to be prognostic in assessment of the risk for development of cardiovascular diseases, facilitating the prediction of outcome in asymptomatic individuals. Currently, several methods to calculate the CAC score exist, and each has its own set of advantages and disadvantages. Agatston CAC scoring is the most extensively used method. CAC scoring is currently recommended for use in asymptomatic individuals to predict the risk of developing cardiovascular diseases and the disease-specific mortality. In specific subsets of patients, the CAC score has also been recommended for reclassifying cardiovascular risk and aiding in decision making when planning primary prevention interventions such as statin therapy. The progression of CAC scores on follow-up images has been shown to be linked to risk of myocardial infarction and cardiovascular mortality. While the CAC score is a validated tool used clinically, several challenges, including various pitfalls associated with the acquisition, calculation, and interpretation of the score, prevent more widespread adoption of this metric. Recent research has been focused extensively on strategies to improve existing scoring methods, including measuring calcium attenuation, detecting microcalcifications, and focusing on extracoronary calcifications, and on strategies to improve image acquisition. A better understanding of CAC scoring approaches will help radiologists and other physicians better use and interpret these scores in their workflows. An invited commentary by S. Gupta is available online. Online supplemental material is available for this article. ©RSNA, 2022.


Asunto(s)
Calcinosis , Enfermedades Cardiovasculares , Enfermedad de la Arteria Coronaria , Calcinosis/diagnóstico por imagen , Calcio , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Factores de Riesgo , Tomografía Computarizada por Rayos X
2.
AJR Am J Roentgenol ; 214(4): 775-785, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32045305

RESUMEN

OBJECTIVE. The purpose of this article is to outline the utility of iodine density maps for evaluating cardiothoracic disease and abnormalities. Multiple studies have shown that the variety of images generated from dual-energy spectral detector CT (SDCT) improve identification of cardiothoracic conditions. CONCLUSION. Understanding the technique of SDCT and being familiar with the features of different cardiothoracic conditions on iodine density map images help the radiologist make a better diagnosis.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Medios de Contraste/farmacocinética , Yodo/farmacocinética , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Radiografía Torácica/métodos , Enfermedades Respiratorias/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Humanos , Interpretación de Imagen Radiográfica Asistida por Computador
3.
Echocardiography ; 37(6): 979-981, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32472564

RESUMEN

Involvement of the coronary arteries by immunoglobulin G4-related disease is rare. It can cause coronary artery aneurysm and arterial wall thickening. Imaging plays a key role in the assessment of the coronary arteries and multimodality approach imaging is helpful to make the diagnosis and provide functional and prognostic information.


Asunto(s)
Aneurisma Coronario , Inmunoglobulina G , Aneurisma Coronario/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Humanos , Imagen Multimodal
4.
Echocardiography ; 37(3): 453-455, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-32049379

RESUMEN

Lipomatous hypertrophy of the right ventricle is a rare entity that is usually asymptomatic and diagnosed incidentally in an otherwise healthy individual. Accurate diagnosis and assessment of possible hemodynamic consequences of this pathology is, however, necessary to secure an appropriate treatment. Multimodality imaging with echocardiography, CT, and cardiac MR can provide useful functional and anatomic information that can help to reach this goal.


Asunto(s)
Ventrículos Cardíacos , Obstrucción del Flujo Ventricular Externo , Ecocardiografía , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Hipertrofia , Imagen Multimodal , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen
5.
Echocardiography ; 37(4): 632-636, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32240548

RESUMEN

Despite advances in cardiovascular imaging, the diagnosis of constrictive pericarditis remains challenging. A multimodality approach to the diagnosis of CP is essential to (a) fully assess the extent of pericardial thickening and calcification, (b) detect the functional and hemodynamic consequences of the constricting pericardium, and (c) implement the optimal management strategy in these often complex cases. This case-based review highlights the role and diagnostic ambiguities of multimodality imaging.


Asunto(s)
Calcinosis , Pericarditis Constrictiva , Humanos , Imagen Multimodal , Pericarditis Constrictiva/diagnóstico por imagen , Pericarditis Constrictiva/terapia , Pericardio
7.
Echocardiography ; 36(11): 2094-2098, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31621950

RESUMEN

Quadricuspid pulmonary valve is a rare entity that can be associated with pulmonary artery aneurysm. It is usually asymptomatic and diagnosed incidentally. Association with other congenital or acquired heart diseases has been reported. Echocardiography and gated CT angiography can provide useful functional and anatomic information that can help in the diagnosis and management.


Asunto(s)
Aneurisma/diagnóstico , Angiografía por Tomografía Computarizada/métodos , Ecocardiografía/métodos , Imagen Multimodal/métodos , Arteria Pulmonar , Insuficiencia de la Válvula Pulmonar/diagnóstico , Válvula Pulmonar/anomalías , Anciano , Aneurisma/etiología , Diagnóstico Diferencial , Femenino , Humanos , Hallazgos Incidentales , Masculino , Persona de Mediana Edad , Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/congénito
8.
J Comput Assist Tomogr ; 42(6): 925-931, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30371610

RESUMEN

OBJECTIVE: The aim of the study was to establish the reference window settings for display of virtual monoenergetic images (VMIs) from spectral detector computed tomography when assessing hypodense liver lesions. METHODS: In patients with cysts (n = 24) or metastases (n = 26), objective (HU, signal-to-noise ratio [SNR]) and subjective (overall image quality, lesion conspicuity and noise) were assessed. Furthermore, 2 readers determined optimal window center/width (C/W) for conventional images (CIs) and VMIs of 40 to 120 keV. Center/width were modeled against HUliv with and without respect to the keV level (models A and B). RESULTS: Attenuation and SNR were significantly higher in low-keV VMIs and improved overall image quality and lesion conspicuity (P ≤ 0.05). Model B provided valid estimations of C/W, whereas model A was slightly less accurate. CONCLUSIONS: The increase in attenuation and SNR on low-keV VMIs requires adjustment of C/W, and they can be estimated in dependency of HUliv using linear models. Reference values for standard display of VMIs of 40 to 120 keV are reported.


Asunto(s)
Hepatopatías/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Biopsia , Medios de Contraste , Femenino , Humanos , Hepatopatías/patología , Masculino , Estudios Prospectivos , Valores de Referencia , Relación Señal-Ruido
9.
Pediatr Radiol ; 46(8): 1096-113, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26718199

RESUMEN

Late gadolinium enhancement (LGE) cardiac magnetic resonance (MR) imaging sequence is increasingly used in the evaluation of pediatric cardiovascular disorders, and although LGE might be a normal feature at the sites of previous surgeries, it is pathologically seen as a result of extracellular space expansion, either from acute cell damage or chronic scarring or fibrosis. LGE is broadly divided into ischemic and non-ischemic patterns. LGE caused by myocardial infarction occurs in a vascular distribution and always involves the subendocardial portion, progressively involving the outer regions in a waveform pattern. Non-ischemic cardiomyopathies can have a mid-myocardial (either linear or patchy), subepicardial or diffuse subendocardial distribution. Idiopathic dilated cardiomyopathy can have a linear mid-myocardial pattern, while hypertrophic cardiomyopathy can have fine, patchy enhancement in hypertrophied and non-hypertrophied segments as well as right ventricular insertion points. Myocarditis and sarcoidosis have a mid-myocardial or subepicardial pattern of LGE. Fabry disease typically affects the basal inferolateral segment while Danon disease typically spares the septum. Pericarditis is characterized by diffuse or focal pericardial thickening and enhancement. Thrombus, the most common non-neoplastic cardiac mass, is characterized by absence of enhancement in all sequences, while neoplastic masses show at least some contrast enhancement, depending on the pathology. Regardless of the etiology, presence of LGE is associated with a poor prognosis. In this review, we describe the technical modifications required for performing LGE cardiac MR sequence in children, review and illustrate the patterns of LGE in children, and discuss their clinical significance.


Asunto(s)
Medios de Contraste , Gadolinio , Cardiopatías/diagnóstico por imagen , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Niño , Corazón/diagnóstico por imagen , Humanos
12.
J Cardiovasc Magn Reson ; 16: 79, 2014 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-25315256

RESUMEN

BACKGROUND: The determination of left ventricular ejection fraction using cardiovascular magnetic resonance (CMR) requires a steady cardiac rhythm for electrocardiogram (ECG) gating and multiple breathholds to minimize respiratory motion artifacts, which often leads to scan times of several minutes. The need for gating and breathholding can be eliminated by employing real-time CMR methods such as through-time radial GRAPPA. The aim of this study is to compare left ventricular cardiac functional parameters obtained using current gold-standard breathhold ECG-gated functional scans with non-gated free-breathing real-time imaging using radial GRAPPA, and to determine whether scan time or the occurrence of artifacts are reduced when using this real-time approach. METHODS: 63 patients were scanned on a 1.5T CMR scanner using both the standard cardiac functional examination with gating and breathholding and the real-time method. Total scan durations were noted. Through-time radial GRAPPA was employed to reconstruct images from the highly accelerated real-time data. The blood volume in the left ventricle was assessed to determine the end systolic volume (ESV), end diastolic volume (EDV), and ejection fraction (EF) for both methods, and images were rated for the presence of artifacts and quality of specific image features by two cardiac readers. Linear regression analysis, Bland-Altman plots and two-sided t-tests were performed to compare the quantitative parameters. A two-sample t-test was performed to compare the scan durations, and a two-sample test of proportion was used to analyze the presence of artifacts. For the reviewers´ ratings the Wilcoxon test for the equality of the scores' distributions was employed. RESULTS: The differences in EF, EDV, and ESV between the gold-standard and real-time methods were not statistically significant (p-values of 0.77, 0.82, and 0.97, respectively). Additionally, the scan time was significantly shorter for the real-time data collection (p<0.001) and fewer artifacts were reported in the real-time images (p<0.01). In the qualitative image analysis, reviewers marginally preferred the standard images although some features including cardiac motion were equivalently rated. CONCLUSION: Real-time functional CMR with through-time radial GRAPPA performed without ECG-gating under free-breathing can be considered as an alternative to gold-standard breathhold cine imaging for the evaluation of ejection fraction in patients.


Asunto(s)
Técnicas de Imagen Sincronizada Cardíacas/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Volumen Sistólico , Función Ventricular Izquierda , Artefactos , Contencion de la Respiración , Electrocardiografía , Frecuencia Cardíaca , Humanos , Modelos Lineales , Variaciones Dependientes del Observador , Ohio , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Factores de Tiempo
13.
J Card Surg ; 28(6): 693-4, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23930737

RESUMEN

We present a rare complication of sternotomy wire removal in a patient with history of coronary artery bypass graft four years prior now undergoing redo sternotomy for aortic valve replacement. Upon removal of the third sternotomy wire the patient experienced hemoptysis from intrapulmonary hemorrhage, requiring that the procedure be aborted; careful review of preoperative computed tomography (CT) demonstrated this sternotomy wire to be traversing through lung parenchyma.


Asunto(s)
Hemoptisis/etiología , Hemorragia/complicaciones , Fijadores Internos/efectos adversos , Complicaciones Intraoperatorias/etiología , Enfermedades Pulmonares/complicaciones , Esternotomía/efectos adversos , Esternotomía/métodos , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Puente de Arteria Coronaria , Implantación de Prótesis de Válvulas Cardíacas , Hemorragia/diagnóstico por imagen , Humanos , Enfermedades Pulmonares/diagnóstico por imagen , Masculino , Periodo Preoperatorio , Reoperación , Tomografía Computarizada por Rayos X
14.
Cureus ; 15(7): e42509, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37637593

RESUMEN

In this report, we present a series involving critically ill patients with known coronavirus disease (COVID-19) infection where a portable X-ray machine equipped with artificial intelligence (AI) software aided in the urgent radiographic diagnosis of pneumothorax. These cases demonstrate how real-world clinical employment of AI tools capable of analyzing and prioritizing studies in the radiologist's worklist can potentially lead to earlier detection of emergent findings like pneumothorax. The use of AI tools in this manner has the potential to both improve radiology workflow and add significant clinical value in managing critically ill patient populations, such as those with severe COVID-19 infection.

15.
J Digit Imaging ; 25(1): 129-36, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21557030

RESUMEN

Cardiovascular disease is the leading cause of global mortality, yet its early detection remains a vexing problem of modern medicine. Although the computed tomography (CT) calcium score predicts cardiovascular risk, relatively high cost ($250-400) and radiation dose (1-3 mSv) limit its universal utility as a screening tool. Dual-energy digital subtraction radiography (DE; <$60, 0.07 mSv) enables detection of calcified structures with high sensitivity. In this pilot study, we examined DE radiography's ability to quantify coronary artery calcification (CAC). We identified 25 patients who underwent non-contrast CT and DE chest imaging performed within 12 months using documented CAC as the major inclusion criteria. A DE calcium score was developed based on pixel intensity multiplied by the area of the calcified plaque. DE scores were plotted against CT scores. Subsequently, a validation cohort of 14 additional patients was independently evaluated to confirm the accuracy and precision of CAC quantification, yielding a total of 39 subjects. Among all subjects (n = 39), the DE score demonstrated a correlation coefficient of 0.87 (p < 0.0001) when compared with the CT score. For the 13 patients with CT scores of <400, the correlation coefficient was -0.26. For the 26 patients with CT scores of ≥400, the correlation coefficient yielded 0.86. This pilot study demonstrates the feasibility of DE radiography to identify patients at the highest cardiovascular risk. DE radiography's accuracy at lower scores remains unclear. Further evaluation of DE radiography as an inexpensive and low-radiation imaging tool to diagnose cardiovascular disease appears warranted.


Asunto(s)
Angiografía de Substracción Digital/métodos , Calcinosis/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios de Casos y Controles , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/fisiopatología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Índice de Severidad de la Enfermedad , Estadísticas no Paramétricas
16.
Transplantation ; 106(12): 2462-2465, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-35883241

RESUMEN

Lung transplant patients often suffer from posttransplant airway pathologies that require placement of endobronchial stents. In addition to surveillance bronchoscopy, patients often undergo radiographic stent evaluations. Chest x-rays are extremely limited in their ability to diagnose stent complications, so many patients require chest computed tomography (CT) scans for stent evaluation. Chest CT scans are costly and expose patients to higher cumulative radiation doses. Digital tomosynthesis (DTS) is an imaging modality that provides high-resolution images using limited angle tomography. The costs and radiation doses are comparable to conventional x-ray. We present a series of 4 postlung transplant patients with bronchial stents in whom we performed DTS and chest x-ray simultaneously. The DTS images were far superior to chest x-ray and comparable with CT in evaluating the placement and patency of the stents, especially in the case of silicone stents. Furthermore, the improved resolution provided clinically relevant diagnostic information that resulted in therapeutic bronchoscopy for suctioning of mucus impaction in one of the patients.


Asunto(s)
Radiografía Torácica , Receptores de Trasplantes , Humanos , Radiografía Torácica/métodos , Pulmón , Tomografía Computarizada por Rayos X/métodos , Stents
17.
AJR Am J Roentgenol ; 196(5): W613-20, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21512053

RESUMEN

OBJECTIVE: The purpose of this essay is to describe the basic principles behind contrast-enhanced time-resolved MR angiography (MRA) performed with the time-resolved imaging with stochastic trajectories technique and to show examples of the versatile applications of this technique in the evaluation of pathologic conditions throughout the body. CONCLUSION: Time-resolved MR angiography is a versatile technique for vascular imaging throughout the body. It can be used to answer a variety of clinical questions; to acquire diagnostically useful information, even about complicated vascular lesions; and to overcome many of the limitations of bolus-chase contrast-enhanced MR angiography. The technique is particularly useful when the arterial arrival time is uncertain, the patient is freely breathing, or contrast dynamics are critical to a diagnosis.


Asunto(s)
Angiografía por Resonancia Magnética , Medios de Contraste , Humanos , Angiografía por Resonancia Magnética/instrumentación , Angiografía por Resonancia Magnética/métodos , Factores de Tiempo
18.
Clin Imaging ; 70: 46-48, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33120288

RESUMEN

BACKGROUND: Diagnosis of amiodarone lung toxicity on computerized tomography (CT) can be challenging especially in the presence of mass-like consolidation. Additional causes of mass-like consolidation including malignancy and pneumonia should be excluded, sometimes requiring tissue sampling. CASE: Here we present a case of amiodarone lung toxicity, with diagnosis suspected based on patient's history of chronic cardiac disease, amiodarone treatment, and imaging characteristics. Evaluation with dual energy CT demonstrated high iodine content in the mass-like consolidation further supporting the diagnosis. Biopsy of the mass-like consolidation confirmed amiodarone toxicity. CONCLUSION: Dual energy CT has potential utility in differentiating mass-like consolidation from other etiologies such as malignancy or pneumonia.


Asunto(s)
Amiodarona , Enfermedades Pulmonares , Amiodarona/efectos adversos , Antiarrítmicos , Humanos , Pulmón/diagnóstico por imagen , Tomografía Computarizada por Rayos X
19.
J Am Coll Radiol ; 18(11): 1497-1505, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34597622

RESUMEN

Although interest in artificial intelligence (AI) has exploded in recent years and led to the development of numerous commercial and noncommercial algorithms, the process of implementing such tools into day-to-day clinical practice is rarely described in the burgeoning AI literature. In this report, we describe our experience with the successful integration of an AI-enabled mobile x-ray scanner with an FDA-approved algorithm for detecting pneumothoraces into an end-to-end solution capable of extracting, delivering, and prioritizing positive studies within our thoracic radiology clinical workflow. We also detail several sample cases from our AI algorithm and associated PACS workflow in action to highlight key insights from our experience. We hope this report can help inform other radiology enterprises seeking to evaluate and implement AI-related workflow solutions into daily clinical practice.


Asunto(s)
Neumotórax , Radiología , Algoritmos , Inteligencia Artificial , Humanos , Neumotórax/diagnóstico por imagen , Radiografía
20.
Curr Probl Diagn Radiol ; 50(6): 925-936, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33041159

RESUMEN

Coronary artery disease (CAD) remains the most common cardiovascular disease, accounting for 6% of all Emergency Department visits and 27% of all Emergency Department hospitalizations.1 Invasive coronary angiography with fractional flow reserve (FFR) remains the gold standard to assess for hemodynamically stenosis in CAD patients. However, for low- and intermediate-risk patients, noninvasive modalities have started to gain favor as patients with stable CAD who received optimal medical therapy did as well as patients who underwent percutaneous coronary intervention.2 This led to the incorporation of FFRCT. cCTA provides good spatial resolution for evaluating stenosis. FFR provides additional information regarding whether the stenosis is hemodynamically significant. FFR is the ratio of maximum blood flow in a stenotic artery to the maximum blood flow through that artery without stenosis.3 Computational fluid dynamics involved in FFRCT is based on Navier-Stokes equations, allowing the assessment of pressure and flow across coronary arteries. Limitations do exist with FFRCT which includes false-positive results due to step artifact and left ventricular hypertrophy, as well as manual segmentation and ostial stenosis, which can cause false-negative results. However, there are improvements on the horizon including artificial intelligence-driven computation of FFR and the utilization of virtual stenting for surgical planning. The purpose of this review is to describe the clinical validation, underlying mechanism, and implementation of FFRCT.


Asunto(s)
Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Inteligencia Artificial , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Humanos , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA