Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Bases de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Skeletal Radiol ; 43(11): 1567-75, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24986652

RESUMEN

OBJECTIVE: To determine whether differences in subchondral sclerosis at the tibial plateau could be detected with magnetic resonance (MR) imaging in two different age groups. MATERIALS AND METHODS: This was a retrospective hypothesis-testing study. Thirty-two knees in group A (25-30 year olds) and 32 knees in group B (45-50 years old) were included. Participants had no MR features of osteoarthritis (OA). On coronal images, tibial articular cartilage thickness was measured, and regions of interest were created in the medial and lateral tibial plateau subchondral bone and in the tibial metaphysis. The measure of heterogeneity at the tibial plateaux was the ratio of the standard deviation of the signal in the medial/lateral compartment to the standard deviation of the signal in the metaphysis (ratio of standard deviations--RSS(medial)/RSS(lateral)). Differences between groups were assessed using unpaired Student's t-tests. RESULTS: Mean RSS(medial) was 2.61 (standard deviation, SD = 0.77) in group A and 2.97 (SD = 0.59) in group B. Mean RSS(lateral) in group A was 1.86 (SD = 0.63) and 1.89 (SD = 0.43) in group B. Mean total cartilage thickness (in mm) in group A was 3.38 (SD = 0.90) for the medial and 3.90 (SD = 1.09) for the lateral compartment and 3.44 (SD = 0.74) for the medial and 3.96 (SD = 0.96) for the lateral compartment in group B. The only parameter to show a statistically significant difference between groups was RSS(medial) (p = 0.04). CONCLUSION: A difference in medial subchondral bone sclerosis between two age groups was demonstrated in the absence of MR features of OA. This may represent the earliest OA change detectable on MR imaging.


Asunto(s)
Articulación de la Rodilla/patología , Imagen por Resonancia Magnética/métodos , Osteoartritis de la Rodilla/patología , Tibia/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Esclerosis/patología , Sensibilidad y Especificidad
2.
Abdom Radiol (NY) ; 43(7): 1787-1797, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29177924

RESUMEN

PURPOSE: This study aims to investigate the role of diffusion-weighted imaging (DWI) and T2-weighted imaging (T2WI) in combination for the detection of prostate cancer, specifically assessing the role of high b-values (> 1000 s/mm2), with a systematic review and meta-analysis of the existing published data. METHODS: The electronic databases MEDLINE, EMBASE, and OpenSIGLE were searched between inception and September 1, 2017. Eligible studies were those that reported the sensitivity and specificity of DWI and T2WI for the diagnosis of prostate cancer by visual assessment using a histopathologic reference standard. The QUADAS-2 critical appraisal tool was used to assess the quality of included studies. A meta-analysis with pooling of sensitivity, specificity, likelihood, and diagnostic odds ratios was undertaken, and a summary receiver-operating characteristics (sROC) curve was constructed. Predetermined subgroup analysis was also performed. RESULTS: Thirty-three studies were included in the final analysis, evaluating 2949 patients. The pooled sensitivity and specificity were 0.69 (95% CI 0.68-0.69) and 0.84 (95% CI 0.83-0.85), respectively, and the sROC AUC was 0.84 (95% CI 0.81-0.87). Subgroup analysis showed significantly better sensitivity with high b-values (> 1000 s/mm2). There was high statistical heterogeneity between studies. CONCLUSION: The diagnostic accuracy of combined DWI and T2WI is good with high b-values (> 1000 s/mm2) seeming to improve overall sensitivity while maintaining specificity. However, further large-scale studies specifically looking at b-value choice are required before a categorical recommendation can be made.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Masculino , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
J Orthop Trauma ; 25(10): 618-29, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21904170

RESUMEN

Recent innovations have greatly increased the range of proximal humeral fractures that are amenable to open reduction and plate fixation.The optimum technique for some of the more complex fracture patterns is not yet fully refined.This article aims to describe the recent advances in the treatment of complex proximal humeral fractures by open reduction and locking plate fixation, focusing particularly on the indications for surgery, the operative techniques, and the expected outcomes after treatment.


Asunto(s)
Placas Óseas , Fijación Interna de Fracturas/métodos , Fracturas del Hombro/cirugía , Fijación Interna de Fracturas/efectos adversos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA