1.
Eur Spine J ; 31(4): 963-979, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35092449

RESUMEN

PURPOSE: Although distraction-based growing rods (GR) are the gold standard for the treatment of early onset scoliosis, they suffer from high failure rates. We have (1) performed a literature search to understand the deficiencies of the current protocols, (2) in vitro evaluation of GRs using our proposed protocol and performed a finite element (FE) model validation, and (3) identified key features which should be considered in mechanical testing setups. METHODS: PubMed, Embase, and Web of Science databases were searched for articles published on (a) in vivo animal, in vitro cadaveric, and biomechanical studies analyzing the use of GRs as well as (b) failure mechanisms and risk factors for GRs. Both FE and benchtop models of a proposed TGR test construct were developed and evaluated for two cases, long tandem connectors (LT), and side-by-side connectors (SBS). The test construct consisted of five polymer blocks representing vertebral bodies, joined with springs to simulate spinal stiffness. The superior and inferior blocks accepted the pedicle screw anchors, while the three middle blocks were floating. After the pedicle screws, rods, and connectors were assembled onto this construct, distraction was performed, mimicking scoliosis surgery. The resulting distracted constructs were then subjected to static compression-bending loading. Yield load and stiffness were calculated and used to verify/validate the FE results. RESULTS: From the literature search, key features identified as significant were axial and transverse connectors, contoured rods, and distraction, distraction being the most challenging feature to incorporate in testing. The in silico analyses, once they are validated, can be used as a complementing technique to investigate other anatomical features which are not possible in the mechanical setup (like growth/scoliosis curvature). Based on our experiment, the LT constructs showed higher stiffness and yield load compared to SBS (78.85 N/mm vs. 59.68 N/mm and 838.84 N vs. 623.3 N). The FE predictions were in agreement with the experimental outcomes (within 10% difference). The maximum von Mises stresses were predicted adjacent to the distraction site, consistent with the location of observed failures in vivo. CONCLUSION: The two-way approach presented in this study can lead to a robust prediction of the contributing factors to the in vivo failure.


Asunto(s)
Tornillos Pediculares , Escoliosis , Fusión Vertebral , Humanos , Escoliosis/cirugía , Fusión Vertebral/métodos , Columna Vertebral
2.
Eur Spine J ; 31(11): 3050-3059, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35932334

RESUMEN

PURPOSE: Multi-rod constructs are used commonly to stabilize pedicle subtraction osteotomies (PSO). This study aimed to evaluate biomechanical properties of different satellite rod configurations and effects of screw-type spanning a PSO. METHODS: A validated 3D spinopelvic finite element model with a L3 PSO (30°) was used to evaluate 5 models: (1) Control (T10-pelvis + 2 rods); (2) lateral satellite rods connected via offsets to monoaxial screws (LatSat-Mono) or (3) polyaxial screws (LatSat-Poly); (4) in-line satellite rods connected to monoaxial screws (InSat-Mono) or (4) polyaxial screws (InSat-Poly). Global and PSO range of motions (ROM) were recorded. Rods' von Mises stresses and PSO forces were recorded and the percent differences from Control were calculated. RESULTS: All satellite rods (save InSat-Mono) increased PSO ROM and decreased primary rods' von Mises stresses at the PSO. Lateral rods increased PSO forces (LatSat-Mono:347.1 N; LatSat-Poly:348.6 N; Control:336 N) and had relatively lower stresses, while in-line rods decreased PSO forces (InSat-Mono:280.1 N; InSat-Poly:330.7 N) and had relatively higher stresses. Relative to polyaxial screws, monoaxial screws further decreased PSO ROM, increased satellite rods' stresses, and decreased PSO forces for in-line rods, but did not change PSO forces for lateral rods. CONCLUSION: Multi-rod constructs using in-line and lateral satellite rods across a PSO reduced primary rods' stresses. Subtle differences in biomechanics suggest lateral satellite rods, irrespective of screw type, increase PSO forces and lower rod stresses compared to in-line satellite rods, which had a high degree of posterior instrumentation stress shielding and lower PSO forces. Clinical studies are warranted to determine if these findings influence clinical outcomes.


Asunto(s)
Tornillos Pediculares , Fusión Vertebral , Humanos , Tornillos Óseos , Fenómenos Biomecánicos , Rango del Movimiento Articular , Osteotomía , Vértebras Lumbares/cirugía
3.
J Biomech Eng ; 143(10)2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-34008847

RESUMEN

Cartilage defects are common in the knee joint of active athletes and remain a problem as a strong risk factor for osteoarthritis. We hypothesized that landing during sport activities, implication for subfailure ACL loading, would generate greater contact pressures (CP) at the lateral knee compartment. The purpose of this study is to investigate tibiofemoral cartilage CP of athletes during landing. Tibiofemoral cartilage contact pressures (TCCP) under clinically relevant anterior cruciate ligament subfailure external loadings were predicted using four dynamic explicit finite element (FE) models (2 males and 2 females) of the knee. Bipedal landing from a jump for five cases of varying magnitudes of external loadings (knee abduction moment, internal tibial torque, and anterior tibial shear) followed by an impact load were simulated. Lateral TCCP from meniscus (area under meniscus) and from femur (area under femur) increased by up to 94% and %30 respectively when external loads were incorporated with impact load in all the models compared to impact-only case. In addition, FE model predicted higher CP in lateral compartment by up to 37% (11.87 MPa versus 8.67 MPa) and 52% (20.19 MPa versus 13.29 MPa) for 90% and 50% percentile models, respectively. For the same percentile populations, CPs were higher by up to 25% and 82% in smaller size models than larger size models. We showed that subfailure ACL loadings obtained from previously conducted in vivo study led to high pressures on the tibiofemoral cartilage. This knowledge is helpful in enhancing neuromuscular training for athletes to prevent cartilage damage.


Asunto(s)
Análisis de Elementos Finitos
4.
Eur Spine J ; 30(8): 2351-2359, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34023965

RESUMEN

PURPOSE: This study's objective was to assess biomechanical parameters across fused and contralateral sacroiliac joints (SIJs) and implants during all spinal motions for both sexes. Various SIJ implant devices on the market are used in minimally invasive surgeries. These implants are placed across the joint using different surgical approaches. The biomechanical effects of fusion surgical techniques in males and females have not been studied. METHODS: The validated finite element models of a male, and a female spine-pelvis-femur were unilaterally instrumented across the SIJ using three screws for two SIJ implants, half threaded and fully threaded screws placed laterally and posteriorly to the joint, respectively. RESULTS: Motion and peak stress data at the SIJs showed that the female model exhibited lower stresses and higher reduction in motion at the contralateral SIJ in all motions than the male model predictions with 84% and 71% reductions in motion and stresses across the SIJ. CONCLUSION: Implants exhibited higher stresses in the female model compared to the male model. However, chances of SIJ implant failure in the female patients are still minimal, based on the calculated factor of safety which is still very high. Both lateral and posterior surgical approaches were effective in both sexes; however, the lateral approach may provide a better biomechanical response, especially for females. Moreover, implant design characteristics did not make a difference in the implants' biomechanical performance. SIJ stabilization was primarily provided by the implants which were the farthest from the sacrum rotation center.


Asunto(s)
Dolor de la Región Lumbar , Articulación Sacroiliaca , Fenómenos Biomecánicos , Femenino , Análisis de Elementos Finitos , Humanos , Masculino , Procedimientos Quirúrgicos Mínimamente Invasivos , Prótesis e Implantes , Articulación Sacroiliaca/cirugía
5.
Eur Spine J ; 30(9): 2622-2630, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34259908

RESUMEN

PURPOSE: Lumbar procedures for Transforaminal Lumbar Interbody Fusion (TLIF) range from open (OS) to minimally invasive surgeries (MIS) to preserve paraspinal musculature. We quantify the biomechanics of cross-sectional area (CSA) reduction of paraspinal muscles following TLIF on the adjacent segments. METHODS: ROM was acquired from a thoracolumbar ribcage finite element (FE) model across each FSU for flexion-extension. A L4-L5 TLIF model was created. The ROM in the TLIF model was used to predict muscle forces via OpenSim. Muscle fiber CSA at L4 and L5 were reduced from 4.8%, 20.7%, and 90% to simulate muscle damage. The predicted muscle forces and ROM were applied to the TLIF model for flexion-extension. Stresses were recorded for each model. RESULTS: Increased ROM was present at the cephalad (L3-L4) and L2-L3 level in the TLIF model compared to the intact model. Graded changes in paraspinal muscles were seen, the largest being in the quadratus lumborum and multifidus. Likewise, intradiscal pressures and annulus stresses at the cephalad level increased with increasing CSA reduction. CONCLUSIONS: CSA reduction during the TLIF procedure can lead to adjacent segment alterations in the spinal element stresses and potential for continued back pain, postoperatively. Therefore, minimally invasive techniques may benefit the patient.


Asunto(s)
Vértebras Lumbares , Fusión Vertebral , Análisis de Elementos Finitos , Humanos , Enfermedad Iatrogénica , Vértebras Lumbares/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Músculos Paraespinales/diagnóstico por imagen , Rango del Movimiento Articular , Fusión Vertebral/efectos adversos
6.
J Foot Ankle Surg ; 55(3): 444-9, 2016.
Artículo en Inglés | MEDLINE | ID: mdl-26884262

RESUMEN

First metatarsocuneiform joint arthrodesis with a locking bone plate and screw system has been effectively used to correct metatarsus primus varus and instability of the first ray. The goal of the present cadaveric biomechanical study was to quantify and compare the inherent strength of the first metatarsocuneiform joint and surrounding bones fixated with the osteo-WEDGE(™) bone plate locking system (OW) with that of intact specimens. Fourteen fresh-frozen adult human cadaveric foot specimens consisting of the first metatarsal and medial cuneiform bones with intact joint capsules and ligaments were used. The OW was implanted in 7 of these specimens at the first metatarsal cuneiform joint (MCJ), and the remaining 7 specimens were left intact. Each of the specimens was then subjected to axial force to simulate dorsiflexion of the first metatarsal using a cantilever bending test setup. Load was applied on the plantar aspect of the first metatarsal head until failure of the construct. The mean load and bending moment on the first MCJ at failure for the implanted specimens were 119.98 ± 56.76 N and 5.57 ± 2.71 Nm, respectively. For the intact specimens, the mean load and bending moment on the first MCJ at failure were 107.93 ± 60.90 N and 6.07 ± 3.18 Nm, respectively. None of the specimens showed catastrophic failure within the physiologic loading limits. These results imply that the mechanical strength of the OW is comparable to that of intact specimens. Thus, the first MCJ and surrounding bones fixated with an OW should be able to effectively withstand the vertical ground reaction forces the same as intact specimens.


Asunto(s)
Artrodesis/instrumentación , Placas Óseas , Hallux Valgus/cirugía , Articulaciones Tarsianas/cirugía , Adulto , Artrodesis/métodos , Fenómenos Biomecánicos , Humanos , Huesos Metatarsianos/cirugía , Diseño de Prótesis , Huesos Tarsianos/cirugía
7.
BMC Vet Res ; 11: 184, 2015 Aug 06.
Artículo en Inglés | MEDLINE | ID: mdl-26245514

RESUMEN

BACKGROUND: Previous studies in humans have reported that the dimensions of the intervertebral foramina change significantly with movement of the spine. Cervical spondylomyelopathy (CSM) in dogs is characterized by dynamic and static compressions of the neural components, leading to variable degrees of neurologic deficits and neck pain. Studies suggest that intervertebral foraminal stenosis has implications in the pathogenesis of CSM. The dimensions of the cervical intervertebral foramina may significantly change during neck movements. This could have implication in the pathogenesis of CSM and other diseases associated with radiculopathy such as intervertebral disc disease. The purpose of this study was to quantify the morphological changes in the intervertebral foramina of dogs during flexion, extension, traction, and compression of the canine cervical vertebral column. All vertebral columns were examined with magnetic resonance imaging prior to biomechanic testing. Eight normal vertebral columns were placed in Group 1 and eight vertebral columns with intervertebral disc degeneration or/and protrusion were assigned to Group 2. Molds of the left and right intervertebral foramina from C4-5, C5-6 and C6-7 were taken during all positions and loading modes. Molds were frozen and vertical (height) and horizontal (width) dimensions of the foramina were measured. Comparisons were made between neutral to flexion and extension, flexion to extension, and traction to compression in neutral position. RESULTS: Extension decreased all the foraminal dimensions significantly, whereas flexion increased all the foraminal dimensions significantly. Compression decreased all the foraminal dimensions significantly, and traction increased the foraminal height, but did not significantly change the foraminal width. No differences in measurements were seen between groups. CONCLUSIONS: Our results show movement-related changes in the dimensions of the intervertebral foramina, with significant foraminal narrowing in extension and compression.


Asunto(s)
Vértebras Cervicales/anatomía & histología , Vértebras Cervicales/fisiología , Perros/anatomía & histología , Perros/fisiología , Disco Intervertebral/anatomía & histología , Disco Intervertebral/fisiología , Movimiento , Animales , Fenómenos Biomecánicos , Cadáver
8.
J Spinal Disord Tech ; 28(3): E133-9, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25310387

RESUMEN

STUDY DESIGN: A biomechanical ex vivo study of the human lumbar spine. OBJECTIVE: To evaluate the effects of transpedicular screw insertion depth on overall screw stability and pullout strength following cyclic loading in the osteoporotic lumbar spine. SUMMARY OF BACKGROUND DATA: Although much is known about the clinical outcomes of spinal fusion, questions remain in our understanding of the biomechanical strength of lumbar pedicle screw fixation as it relates to screw sizing and placement. Biomechanical analyses examining ideal pedicle screw depth with current pedicle screw technology are limited. In the osteoporotic spine, optimized pedicle screw insertion depth may improve construct strength, decreasing the risk of loosening or pullout. METHODS: A total of 100 pedicles from 10 osteoporotic lumbar spines were randomly instrumented with pedicle screws in mid-body, pericortical, and bicortical depths. Instrumented specimens underwent cyclic loading (5000 cycles of ±2 N m pure flexion moment) and subsequent pullout. Screw loosening, failure loads, and energy absorption were calculated. RESULTS: Cyclic loading significantly (P<0.001) reduced screw-bone angular stiffness between prefatigue and postfatigue conditions by 25.6%±17.9% (mid-body), 20.8%±14.4% (pericortical), and 14.0%±13.0% (bicortical). Increased insertion depth resulted in lower levels of reduction in angular stiffness, which was only significant between mid-body and bicortical screws (P=0.009). Pullout force and energy of 583±306 N and 1.75±1.98 N m (mid-body), 713±321 N and 2.40±1.79 N m (pericortical), and 797±285 N and 2.97±2.33 N m (bicortical) were observed, respectively. Increased insertion depth resulted in higher magnitudes of both pullout force and energy, which was significant only for pullout force between mid-body and bicortical screws (P=0.005). CONCLUSION: Although increased screw depth led to increased fixation and decreased loosening, additional purchase of the stiff anterior cortex is essential to reach superior screw-bone construct stability and stiffness.


Asunto(s)
Vértebras Lumbares/fisiología , Vértebras Lumbares/cirugía , Tornillos Pediculares , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Adulto , Anciano , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Técnicas In Vitro , Masculino , Persona de Mediana Edad , Osteoporosis/fisiopatología , Osteoporosis/cirugía , Distribución Aleatoria , Estrés Mecánico , Resistencia a la Tracción
9.
Vet Surg ; 44(4): 459-66, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25412567

RESUMEN

OBJECTIVE: To quantify changes in the diameter of the vertebral canal with flexion and extension in the cervical vertebral column. STUDY DESIGN: Cadaveric biomechanical study. SAMPLE POPULATION: Cadaveric canine cervical vertebral column (n = 16 dogs). METHODS: All vertebral columns were evaluated with MRI. Group 1 consisted of 8 normal vertebral columns. Group 2 included 8 vertebral columns with intervertebral disc degeneration. Flexion, extension, compression, and tension were applied to the caudal cervical region (C4-5, C5-6, C6-7). Sagittal vertebral canal diameters (VCD) were obtained by measuring the distance between the ventral and dorsal aspects of vertebral canal. RESULTS: No differences were seen between groups, thus the results are for both groups. Comparison of VCD between flexion and extension with no load revealed a difference of 2.2 mm (28.9%; P < .001). Comparison between neutral position and extension revealed a reduction of 1.5 mm (16.5%; P < .001), whereas comparison between neutral and flexion showed an increase of 0.7 mm (7.7%; P = .001) in VCD. Comparison between neutral with no load and neutral with compression showed a difference of 0.5 mm, with reduction of 5.5% in the vertebral canal (P = .006). Comparison of extension with no load versus extension with tension revealed an increase of 0.7 mm (9.2%) in the vertebral canal (P < .001). CONCLUSIONS: Cervical vertebral canal diameter decreased significantly with extension and increased with flexion. The results support the presence of dynamic impingement possibly playing a role in diseases characterized by vertebral canal stenosis, such as cervical spondylomyelopathy.


Asunto(s)
Vértebras Cervicales , Enfermedades de los Perros/fisiopatología , Degeneración del Disco Intervertebral/veterinaria , Canal Medular , Animales , Fenómenos Biomecánicos , Cadáver , Enfermedades de los Perros/patología , Perros , Femenino , Degeneración del Disco Intervertebral/fisiopatología , Imagen por Resonancia Magnética/veterinaria , Masculino , Rango del Movimiento Articular
10.
Biomed Eng Online ; 13(1): 26, 2014 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-24618205

RESUMEN

BACKGROUND: The efficacy of dynamic anterior cervical plates is somewhat controversial. Screws in static-plate designs have a smaller diameter and can cut through bone under load. While not ideal, this unintended loosening can help mitigate stress shielding. Stand-alone interbody devices with integral fixation have large endplate contact areas that may inhibit or prevent loosening of the fixation. This study investigates the load sharing ability of a novel dynamic plate design in preventing the stress shielding of the graft material compared to the non-dynamic devices. METHODS: An experimentally validated intact C5-C6 finite element model was modified to simulate discectomy and accommodate implant-graft assembly. Four implant iterations were modeled; InterPlate titanium device with dynamic surface features (springs), InterPlate titanium non-dynamic device, InterPlate titanium design having a fully enclosed graft chamber, and the InterPlate design in unfilled PEEK having a fully enclosed graft chamber. All the models were fixed at the inferior-most surface of C6 and the axial displacement required to completely embed the dynamic surface features was applied to the model. RESULTS: InterPlate device with dynamic surface features induced higher graft stresses compared to the other design iterations resulting in uniform load sharing. The distribution of these graft stresses were more uniform for the InterPlate dynamic design. CONCLUSIONS: These results indicate that the dynamic design decreases the stress shielding by increasing and more uniformly distributing the graft stress. Fully enclosed graft chambers increase stress shielding. Lower implant material modulus of elasticity does not reduce stress shielding significantly.


Asunto(s)
Prótesis e Implantes , Fusión Vertebral/métodos , Ingeniería Biomédica/métodos , Placas Óseas , Trasplante Óseo , Vértebras Cervicales/patología , Elasticidad , Diseño de Equipo , Análisis de Elementos Finitos , Humanos , Fijadores Internos , Estrés Mecánico , Propiedades de Superficie , Titanio/química , Soporte de Peso
11.
J Biomech Eng ; 136(5): 051007, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24599026

RESUMEN

Currently, rigid fixation systems are the gold standard for degenerative disk disease treatment. Dynamic fixation systems have been proposed as alternatives for the treatment of a variety of spinal disorders. These systems address the main drawbacks of traditional rigid fixation systems, such as adjacent segment degeneration and instrumentation failure. Pedicle-screw-based dynamic stabilization (PDS) is one type of these alternative systems. The aim of this study was to simulate the biomechanical effect of a novel posterior dynamic stabilization system, which is comprised of dynamic (hinged) screws interconnected with a coiled, spring-based dynamic rod (DSDR), and compare it to semirigid (DSRR and RSRR) and rigid stabilization (RSRR) systems. A validated finite element (FE) model of L1-S1 was used to quantify the biomechanical parameters of the spine, such as range of motion, intradiskal pressure, stresses and facet loads after single-level instrumentation with different posterior stabilization systems. The results obtained from in vitro experimental intact and instrumented spines were used to validate the FE model, and the validated model was then used to compare the biomechanical effects of different fixation and stabilization constructs with intact under a hybrid loading protocol. The segmental motion at L4-L5 increased by 9.5% and 16.3% in flexion and left rotation, respectively, in DSDR with respect to the intact spine, whereas it was reduced by 6.4% and 10.9% in extension and left-bending loads, respectively. After instrumentation-induced intradiskal pressure at adjacent segments, L3-L4 and L5-S1 became less than the intact in dynamic rod constructs (DSDR and RSDR) except in the RSDR model in extension where the motion was higher than intact by 9.7% at L3-L4 and 11.3% at L5-S1. The facet loads were insignificant, not exceeding 12N in any of the instrumented cases in flexion. In extension, the facet load in DSDR case was similar to that in intact spine. The dynamic rod constructions (DSDR and RSDR) led to a lesser peak stress at screws compared with rigid rod constructions (DSRR and RSRR) in all loading cases. A dynamic construct consisting of a dynamic rod and a dynamic screw did protect the adjacent level from excessive motion.


Asunto(s)
Tornillos Óseos , Análisis de Elementos Finitos , Fenómenos Mecánicos , Fenómenos Biomecánicos , Degeneración del Disco Intervertebral/cirugía , Vértebras Lumbares/lesiones , Vértebras Lumbares/fisiología , Dinámicas no Lineales , Rango del Movimiento Articular
12.
J Biomech Eng ; 136(1): 011002, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24763546

RESUMEN

Multiple computational models have been developed to study knee biomechanics. However, the majority of these models are mainly validated against a limited range of loading conditions and/or do not include sufficient details of the critical anatomical structures within the joint. Due to the multifactorial dynamic nature of knee injuries, anatomic finite element (FE) models validated against multiple factors under a broad range of loading conditions are necessary. This study presents a validated FE model of the lower extremity with an anatomically accurate representation of the knee joint. The model was validated against tibiofemoral kinematics, ligaments strain/force, and articular cartilage pressure data measured directly from static, quasi-static, and dynamic cadaveric experiments. Strong correlations were observed between model predictions and experimental data (r > 0.8 and p < 0.0005 for all comparisons). FE predictions showed low deviations (root-mean-square (RMS) error) from average experimental data under all modes of static and quasi-static loading, falling within 2.5 deg of tibiofemoral rotation, 1% of anterior cruciate ligament (ACL) and medial collateral ligament (MCL) strains, 17 N of ACL load, and 1 mm of tibiofemoral center of pressure. Similarly, the FE model was able to accurately predict tibiofemoral kinematics and ACL and MCL strains during simulated bipedal landings (dynamic loading). In addition to minimal deviation from direct cadaveric measurements, all model predictions fell within 95% confidence intervals of the average experimental data. Agreement between model predictions and experimental data demonstrates the ability of the developed model to predict the kinematics of the human knee joint as well as the complex, nonuniform stress and strain fields that occur in biological soft tissue. Such a model will facilitate the in-depth understanding of a multitude of potential knee injury mechanisms with special emphasis on ACL injury.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Simulación por Computador , Análisis de Elementos Finitos , Traumatismos de la Rodilla/fisiopatología , Rodilla/patología , Rodilla/fisiopatología , Modelos Anatómicos , Fenómenos Biomecánicos , Humanos , Rango del Movimiento Articular , Análisis de Regresión , Rotación , Estrés Fisiológico , Soporte de Peso
13.
J Spinal Disord Tech ; 27(4): E118-27, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24869985

RESUMEN

STUDY DESIGN: A biomechanical finite element modeling study of the human lumbar spine. OBJECTIVE: To evaluate the effects of a transforaminal interbody device's footprint on lumbar spine biomechanics to further examine the potential subtle biomechanical differences not captured in previous studies. SUMMARY OF BACKGROUND DATA: In recent years, the evolution of interbody fusion devices has provided the surgeons with a multitude of options. An articulating transforaminal lumbar interbody fusion (TLIF) device is developed to overcome the surgical challenges associated with insertion of a large footprint interbody device through a small incision. METHODS: A finite element model of the L3-S1 lumbar segment was modified to simulate replacement of various TLIF constructs with different cage designs including an articulating vertebral interbody (AVID) TLIF device and a generic TLIF device placed in different configurations. The instrumented models were subjected to a 400 N follower load along with a 10 N m bending moment at different physiological planes. The kinematics, loads, and stresses were compared among various models. RESULTS: Simulated cage designs provided similar kinematical stability within the treated segments. However, the articulating and double TLIF implants allowed for better load sharing through the anterior column. These implants resulted in lower endplate and pedicle screw stresses and in more homogenous stress distribution across the peripheral region of the endplate. CONCLUSIONS: An articulating, large footprint, peripherally placed TLIF device affords substantial biomechanical advantages. This device may be able to reduce the incidence of subsidence because of its ability to reduce and distribute the endplate stresses in the stronger peripheral region. It may also reduce the posterior hardware failure incidence owing to its ability to reduce the screw stresses as compared with traditional TLIF. Although double TLIF has been demonstrated to have similar biomechanical advantages as the AVID, complications associated with double TLIF (ie, larger surgical incision, longer surgical procedure, placement and alignment challenges) support AVID as a better optimized alternative.


Asunto(s)
Vértebras Lumbares/fisiología , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Fenómenos Biomecánicos , Simulación por Computador , Análisis de Elementos Finitos , Humanos , Rango del Movimiento Articular/fisiología , Estrés Mecánico
14.
Spine Deform ; 12(2): 313-322, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38032447

RESUMEN

PURPOSE: To develop and validate a finite element (FE) model of a sacral pedicle subtraction osteotomy (S1-PSO) and to compare biomechanical properties of various multi-rod configurations to stabilize S1-PSOs. METHODS: A previously validated FE spinopelvic model was used to develop a 30° PSO at the sacrum. Five multi-rod techniques spanning the S1-PSO were made using 4 iliac screws and a variety of primary rods (PR) and accessory rods (AR; lateral: Lat-AR or medial: Med-AR). All constructs, except one, utilized a horizontal rod (HR) connecting the iliac bolts to which PRs and Med-ARs were connected. Lat-ARs were connected to proximal iliac bolts. The simulation was performed in two steps with the acetabula fixed. For each model, PSO ROM and maximum stress on the PRs, ARs, and HRs were recorded and compared. The maximum stress on the L5-S1 disc and the PSO forces were captured and compared. RESULTS: Highest PSO ROMs were observed for 4-Rods (HR + 2 Med-AR). Constructs consisting of 5-Rods (HR + 2 Lat-ARs + 1 Med-AR) and 6-Rods (HR + 2 Lat-AR + 2 Med-AR) had the lowest PSO ROM. The least stress on the primary rods was seen with 6-Rods, followed by 5-Rods and 4-Rods (HR + 2 Lat-ARs). Lowest PSO forces and lowest L5-S1 disc stresses were observed for 4-Rod (Lat-AR), 5-Rod, and 6-Rod constructs, while 4-Rods (HR + Med-AR) had the highest. CONCLUSION: In this first FE analysis of an S1-PSO, the 4-Rod construct (HR + Med-AR) created the least rigid environment and highest PSO forces anteriorly. While 5- and 6-Rods created the stiffest constructs and lowest stresses on the primary rods, it also jeopardized load transfer to the anterior column, which may not be favorable for healing anteriorly. A balance between the construct's rigidity and anterior load sharing is essential.


Asunto(s)
Vértebras Lumbares , Osteotomía , Humanos , Análisis de Elementos Finitos , Fenómenos Biomecánicos , Osteotomía/métodos , Rango del Movimiento Articular , Vértebras Lumbares/cirugía
15.
Bioengineering (Basel) ; 11(4)2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38671770

RESUMEN

BACKGROUND CONTEXT: Pelvic ring fractures are becoming more common in the aging population and can prove to be fatal, having mortality rates between 10% and 16%. Stabilization of these fractures is challenging and often require immediate internal fixation. Therefore, it is necessary to have a biomechanical understanding of the different fixation techniques for pelvic ring fractures. METHODS: A previously validated three-dimensional finite element model of the lumbar spine, pelvis, and femur was used for this study. A unilateral pelvic ring fracture was simulated by resecting the left side of the sacrum and pelvis. Five different fixation techniques were used to stabilize the fracture. A compressive follower load and pure moment was applied to compare different biomechanical parameters including range of motion (contralateral sacroiliac joint, L1-S1 segment, L5-S1 segment), and stresses (L5-S1 nucleus stresses, instrument stresses) between different fixation techniques. RESULTS: Trans-iliac-trans-sacral screw fixation at S1 and S2 showed the highest stabilization for horizontal and vertical displacement at the sacral fracture site and reduction of contralateral sacroiliac joint for bending and flexion range of motion by 165% and 121%, respectively. DTSF (Double transiliac rod and screw fixation) model showed highest stabilization in horizontal displacement at the pubic rami fracture site, while the L5_PF_W_CC (L5-Ilium posterior screw fixation with cross connectors) and L5_PF_WO_CC (L5-Ilium posterior screw fixation without cross connectors) showed higher rod stresses, reduced L1-S1 (approximately 28%), and L5-S1 (approximately 90%) range of motion. CONCLUSIONS: Longer sacral screw fixations were superior in stabilizing sacral and contralateral sacroiliac joint range of motion. Lumbopelvic fixations displayed a higher degree of stabilization in the horizontal displacement compared to vertical displacement of pubic rami fracture, while also indicating the highest rod stresses. When determining the surgical approach for pelvic ring fractures, patient-specific factors should be accounted for to weigh the advantages and disadvantages for each technique.

16.
Clin Biomech (Bristol, Avon) ; 112: 106170, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38198907

RESUMEN

BACKGROUND: Analyzing sports injuries is essential to mitigate risk for injury, but inherently challenging using in vivo approaches. Computational modeling is a powerful engineering tool used to access biomechanical information on tissue failure that cannot be obtained otherwise using traditional motion capture techniques. METHODS: We extrapolated high-risk kinematics associated with ACL strain and cartilage load and stress from a previous motion analysis of 14 uninjured participants. Computational simulations were used to induce ACL failure strain and cartilage failure load, stress, and contact pressure in two age- and BMI-matched participants, one of each biological sex, during single-leg cross drop and single-leg drop tasks. The high-risk kinematics were exaggerated in 20% intervals, within their physiological range of motion, to determine if injury occurred in the models. Where injury occurred, we reported the kinematic profiles that led to tissue failure. FINDINGS: Our findings revealed ACL strains up to 9.99%, consistent with reported failure values in existing literature. Cartilage failure was observed in all eight analyzed conditions when increasing each high-risk kinematic parameter by 2.61 ± 0.67 times the participants' natural landing values. The kinematics associated with tissue failure included peak hip internal rotation of 22.48 ± 19.04°, peak hip abduction of 22.51 ± 9.09°, and peak lumbar rotation away from the stance limb of 11.56 ± 9.78°. INTERPRETATION: Our results support the ability of previously reported high-risk kinematics in the literature to induce injury and add to the literature by reporting extreme motion limits leading to injurious cases. Therefore, training programs able to modify these motions during single-leg landings may reduce the risk of ACL injury and cartilage trauma.


Asunto(s)
Lesiones del Ligamento Cruzado Anterior , Humanos , Lesiones del Ligamento Cruzado Anterior/etiología , Articulación de la Rodilla/fisiología , Fenómenos Biomecánicos , Pierna/fisiología , Cartílago
17.
Spine Deform ; 12(4): 953-959, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38578598

RESUMEN

PURPOSE: To evaluate proximal junctional biomechanics of a MLSS relative to traditional pedicle screw fixation at the proximal extent of T10-pelvis posterior instrumentation constructs (T10-p PSF). METHODS: A previously validated three-dimensional osseoligamentous spinopelvic finite element (FE) model was used to compare proximal junctional range-of-motion (ROM), vertebral body stresses, and discal biomechanics between two groups: (1) T10-p with a T10-11 MLSS ("T10-11 MLSS") and (2) T10-p with a traditional T10 pedicle screw ("Traditional T10-PS"). RESULTS: The T10-11 MLSS had a 5% decrease in T9 cortical bone stress compared to Traditional T10-PS. Conversely, the T10 and T11 bone stresses increased by 46% and 98%, respectively, with T10-11 MLSS compared to Traditional T10-PS. Annular stresses and intradiscal pressures (IDP) were similar at T9-T10 between constructs. At the T10-11 disc, T10-11 MLSS decreased annular stresses by 29% and IDP by 48% compared to Traditional T10-PS. Adjacent ROM (T8-9 & T9-10) were similar between T10-11 MLSS and Traditional T10-PS. T10-11 MLSS had 39% greater ROM at T10-11 and 23% less ROM at T11-12 compared to Traditional T10-PS. CONCLUSIONS: In this FE analysis, a T10-11 MLSS at the proximal extent of T10-pelvis posterior instrumentation resulted in increased T10 and T11 cortical bone stresses, decreased discal annular stress and IDP and increased ROM at T10-11, and no change in ROM at the adjacent level. Given the complex and multifactorial nature of proximal junctional kyphosis, these results require additional biomechanical and clinical evaluations to determine the clinical utility of MLSS on the proximal junctions of thoracolumbar posterior instrumented fusions.


Asunto(s)
Análisis de Elementos Finitos , Vértebras Lumbares , Tornillos Pediculares , Rango del Movimiento Articular , Fusión Vertebral , Vértebras Torácicas , Humanos , Fenómenos Biomecánicos , Vértebras Torácicas/cirugía , Vértebras Lumbares/cirugía , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Estrés Mecánico , Disco Intervertebral/cirugía , Tornillos Óseos
18.
World Neurosurg ; 184: e282-e290, 2024 04.
Artículo en Inglés | MEDLINE | ID: mdl-38280628

RESUMEN

OBJECTIVE: To determine the effects of thoracic stiffness on mechanical stress in the lumbar spine during motion. METHODS: To evaluate the effect of preoperative thoracic flexibility, stiff and flexible spine models were created by changing the material properties of ligaments and discs in the thoracic spine. Total laminectomy was performed at L4/5 in stiff and flexible models. A biomechanical investigation and finite element analysis were performed preoperatively and postoperatively. A hybrid loading condition was applied, and the range of motion (ROM) at each segment and maximum stress in the discs and pars interarticularis were computed. RESULTS: In the preoperative model with the stiff thoracic spine, lumbar disc stress, lumbar ROM, and pars interarticularis stress at L5 increased. In contrast, as the thoracic spine became more flexible, lumbar disc stress, lumbar ROM, and pars interarticularis stress at L5 decreased. All L4/5 laminectomy models had increased instability and ROM at L4/5. To evaluate the effect of thoracic flexibility on the lumbar spine, differences between the stiff and flexible thoracic spine were examined: Differences in ROM and intervertebral disc stress at L4/5 in flexion between the stiff and flexible thoracic spine were respectively 0.7° and 0.0179 MPa preoperatively and 1.5° and 0.0367 MPa in the L4/5 laminectomy model. CONCLUSIONS: Biomechanically, disc stress and pars interarticularis stress decrease in the flexible thoracic spine. Flexibility of the thoracic spine reduces lumbar spine loading and could help to prevent stress-related disorders.


Asunto(s)
Disco Intervertebral , Vértebras Lumbares , Humanos , Análisis de Elementos Finitos , Vértebras Lumbares/cirugía , Laminectomía , Disco Intervertebral/cirugía , Rango del Movimiento Articular , Fenómenos Biomecánicos
19.
Clin Biomech (Bristol, Avon) ; 116: 106269, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38861874

RESUMEN

BACKGROUND: Slipped capital femoral epiphysis is a prevalent pediatric hip disorder. Recent studies suggest the spine's sagittal profile may influence the proximal femoral growth plate's slippage, an aspect not extensively explored. This study utilizes finite element analysis to investigate how various spinopelvic alignments affect shear stress and growth plate slip. METHODS: A finite element model was developed from CT scans of a healthy adult male lumbar spine, pelvis, and femurs. The model was subjected to various sagittal alignments through reorientation. Simulations of two-leg stance, one-leg stance, walking heel strike, ascending stairs heel strike, and descending stairs heel strike were conducted. Parameters measured included hip joint contact area, stress, and maximum growth plate Tresca (shear) stress. FINDINGS: Posterior pelvic tilt cases indicated larger shear stresses compared to the anterior pelvic tilt variants except in two leg stance. Two leg stance resulted in decreases in the posterior tilted pelvi variants hip contact and growth plate Tresca stress compared to anterior tilted pelvi, however a combination of posterior pelvic tilt and high pelvic incidence indicated larger shear stresses on the growth plate. One leg stance and heal strike resulted in higher shear stress on the growth plate in posterior pelvic tilt variants compared to anterior pelvic tilt, with a combination of posterior pelvic tilt and high pelvic incidence resulting in the largest shear. INTERPRETATION: Our findings suggest that posterior pelvic tilt and high pelvic incidence may lead to increased shear stress at the growth plate. Activities performed in patients with these alignments may predispose to biomechanical loading that shears the growth plate, potentially leading to slip.


Asunto(s)
Análisis de Elementos Finitos , Pelvis , Humanos , Masculino , Pelvis/diagnóstico por imagen , Cabeza Femoral/diagnóstico por imagen , Cabeza Femoral/fisiopatología , Estrés Mecánico , Epífisis Desprendida de Cabeza Femoral/fisiopatología , Epífisis Desprendida de Cabeza Femoral/diagnóstico por imagen , Adulto , Simulación por Computador , Articulación de la Cadera/fisiopatología , Articulación de la Cadera/diagnóstico por imagen , Fémur/diagnóstico por imagen , Fémur/fisiopatología , Placa de Crecimiento/diagnóstico por imagen , Placa de Crecimiento/fisiopatología , Placa de Crecimiento/fisiología , Cartílago/diagnóstico por imagen , Modelos Biológicos , Fenómenos Biomecánicos , Postura/fisiología , Columna Vertebral/diagnóstico por imagen , Columna Vertebral/fisiopatología , Columna Vertebral/fisiología
20.
J Biomech Eng ; 135(6): 61005-9, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23699717

RESUMEN

In the thoracolumbar region, between 7% and 30% of spinal fusion failures are at risk for pseudarthrosis. From a biomechanical perspective, the nonconformity of the intervertebral graft to the endplate surface could contribute to pseudarthrosis, given suboptimal stress distributions. The objective of this study was to quantify the effect of endplate-graft conformation on endplate stress distribution, maximum Von Mises stress development, and stability. The study design used an experimentally validated finite element (FE) model of the L4-L5 functional spinal unit to simulate two types of interbody grafts (cortical bone and polycaprolactone (PCL)-hydroxyapatite (HA) graft), with and without endplate-conformed surfaces. Two case studies were completed. In Case Study I, the endplate-conformed grafts and nonconformed grafts were compared under without posterior instrumentation condition, while in Case Study II, the endplate-conformed and nonconformed grafts were compared with posterior instrumentation. In both case studies, the results suggested that the increased endplate-graft conformity reduced the maximum stress on the endplate, created uniform stress distribution on endplate surfaces, and reduced the range of motion of L4-L5 segments by increasing the contact surface area between the graft and the endplate. The stress distributions in the endplate suggest that the load sharing is greater with the endplate-conformed PCL-HA graft, which might reduce the graft subsidence possibility.


Asunto(s)
Trasplante Óseo/métodos , Durapatita/química , Análisis de Elementos Finitos , Vértebras Lumbares/cirugía , Fenómenos Mecánicos , Poliésteres/química , Fusión Vertebral/métodos , Fenómenos Biomecánicos , Vértebras Lumbares/fisiología , Movimiento , Reproducibilidad de los Resultados , Estrés Mecánico , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS