Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Más filtros

Bases de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Sensors (Basel) ; 21(20)2021 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-34695998

RESUMEN

The COVID-19 pandemic has been the most critical public health issue in modern history due to its highly infectious and deathly potential, and the limited access to massive, low-cost, and reliable testing has significantly worsened the crisis. The recovery and the vaccination of millions of people against COVID-19 have made serological tests highly relevant to identify the presence and levels of SARS-CoV-2 antibodies. Due to its advantages, microfluidic-based technologies represent an attractive alternative to the conventional testing methodologies used for these purposes. In this work, we described the development of an automated ELISA on-chip capable of detecting anti-SARS-CoV-2 antibodies in serum samples from COVID-19 patients and vaccinated individuals. The colorimetric reactions were analyzed with a microplate reader. No statistically significant differences were observed when comparing the results of our automated ELISA on-chip against the ones obtained from a traditional ELISA on a microplate. Moreover, we demonstrated that it is possible to carry out the analysis of the colorimetric reaction by performing basic image analysis of photos taken with a smartphone, which constitutes a useful alternative when lacking specialized equipment or a laboratory setting. Our automated ELISA on-chip has the potential to be used in a clinical setting and mitigates some of the burden caused by testing deficiencies.


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Antivirales , Ensayo de Inmunoadsorción Enzimática , Humanos , Pandemias , Sensibilidad y Especificidad
2.
Pharmacogenomics J ; 20(4): 613-620, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32015454

RESUMEN

Oseltamivir, a pro-drug, is the best option for treatment and chemoprophylaxis for influenza outbreaks. However, many patients treated with oseltamivir developed adverse reactions, including hypersensitivity, gastritis, and neurological symptoms. The aim of this study was to determine the adverse drug reactions (ADRs) in Mexican patients treated with oseltamivir and whether these ADRs are associated with SNPs of the genes involved in the metabolism, transport, and interactions of oseltamivir. This study recruited 310 Mexican patients with acute respiratory diseases and treated them with oseltamivir (75 mg/day for 5 days) because they were suspected to have influenza A/H1N1 virus infection. Clinical data were obtained from medical records and interviews. Genotyping was performed using real-time polymerase chain reaction and TaqMan probes. The association was assessed under genetic models with contingency tables and logistic regression analysis. Out of 310 patients, only 38 (12.25%) presented ADRs to oseltamivir: hypersensitivity (1.9%), gastritis (10%), and depression and anxiety (0.9%). The polymorphism ABCB1-rs1045642 was associated with adverse drug reactions under the recessive model (P = 0.017); allele C was associated with no adverse drug reactions, while allele T was associated with adverse drug reactions. The polymorphisms SLC15A1-rs2297322, ABCB1-rs2032582, and CES1-rs2307243 were not consistent with Hardy-Weinberg equilibrium, and no other associations were found for the remaining polymorphisms. In conclusion, the polymorphism rs1045642 in the transporter encoded by the ABCB1 gene is a potential predictive biomarker of ADRs in oseltamivir treatment.


Asunto(s)
Antivirales/metabolismo , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/genética , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/metabolismo , Oseltamivir/metabolismo , Polimorfismo de Nucleótido Simple/genética , Trastornos Respiratorios/genética , Trastornos Respiratorios/metabolismo , Enfermedad Aguda , Adolescente , Adulto , Antivirales/efectos adversos , Transporte Biológico/fisiología , Niño , Interacciones Farmacológicas/fisiología , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/epidemiología , Femenino , Estudios de Asociación Genética/métodos , Humanos , Subtipo H1N1 del Virus de la Influenza A/aislamiento & purificación , Gripe Humana/tratamiento farmacológico , Gripe Humana/epidemiología , Gripe Humana/genética , Gripe Humana/metabolismo , Masculino , México/epidemiología , Persona de Mediana Edad , Oseltamivir/efectos adversos , Transporte de Proteínas/fisiología , Trastornos Respiratorios/tratamiento farmacológico , Trastornos Respiratorios/epidemiología , Estudios Retrospectivos , Adulto Joven
3.
Crit Rev Biotechnol ; 37(1): 53-68, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26611830

RESUMEN

The 2014 Ebola outbreak, the largest recorded, took us largely unprepared, with no available vaccine or specific treatment. In this context, the World Health Organization declared that the humanitarian use of experimental therapies against Ebola Virus (EBOV) is ethical. In particular, an experimental treatment consisting of a cocktail of three monoclonal antibodies (mAbs) produced in tobacco plants and specifically directed to the EBOV glycoprotein (GP) was tested in humans, apparently with good results. Several mAbs with high affinity to the GP have been described. This review discusses our current knowledge on this topic. Particular emphasis is devoted to those mAbs that have been assayed in animal models or humans as possible therapies against Ebola. Engineering aspects and challenges for the production of anti-Ebola mAbs are also briefly discussed; current platforms for the design and production of full-length mAbs are cumbersome and costly.


Asunto(s)
Anticuerpos Monoclonales/uso terapéutico , Fiebre Hemorrágica Ebola/tratamiento farmacológico , Animales , Anticuerpos Monoclonales/economía , Costos y Análisis de Costo , Ebolavirus/genética , Glicoproteínas/inmunología , Fiebre Hemorrágica Ebola/economía , Fiebre Hemorrágica Ebola/epidemiología , Humanos , Proteínas Virales/inmunología
4.
Diagnostics (Basel) ; 14(2)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38275468

RESUMEN

COVID-19 made explicit the need for rethinking the way in which we conduct testing for epidemic emergencies. During the COVID-19 pandemic, the dependence on centralized lab facilities and resource-intensive methodologies (e.g., RT-qPCR methods) greatly limited the deployment of widespread testing efforts in many developed and underdeveloped countries. Here, we illustrate the development of a simple and portable diagnostic kit that enables self-diagnosis of COVID-19 at home from saliva samples. We describe the development of a do-it-yourself (DIY) incubator for Eppendorf tubes that can be used to conduct SARS-CoV-2 detection with competitive sensitivity and selectivity from saliva at home. In a proof-of-concept experiment, we assembled Eppendorf-tube incubators at our home shop, prepared a single-tube mix of reagents and LAMP primers in our lab, and deployed these COVID-19 detection kits using urban delivery systems (i.e., Rappifavor or Uber) to more than 15 different locations in Monterrey, México. This straightforward strategy enabled rapid and cost-effective at-home molecular diagnostics of SARS-CoV-2 from real saliva samples with a high sensitivity (100%) and high selectivity (87%).

5.
Vet Sci ; 10(10)2023 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-37888561

RESUMEN

Molecular diagnostic tests have evolved very rapidly in the field of human health, especially with the arrival of the recent pandemic caused by the SARS-CoV-2 virus. However, the animal sector is constantly neglected, even though accurate detection by molecular tools could represent economic advantages by preventing the spread of viruses. In this regard, the swine industry is of great interest. The main viruses that affect the swine industry are described in this review, including African swine fever virus (ASFV), porcine reproductive and respiratory syndrome virus (PRRSV), porcine epidemic diarrhea virus (PEDV), and porcine circovirus (PCV), which have been effectively detected by different molecular tools in recent times. Here, we describe the rationale of molecular techniques such as multiplex PCR, isothermal methods (LAMP, NASBA, RPA, and PSR) and novel methods such as CRISPR-Cas and microfluidics platforms. Successful molecular diagnostic developments are presented by highlighting their most important findings. Finally, we describe the barriers that hinder the large-scale development of affordable, accessible, rapid, and easy-to-use molecular diagnostic tests. The evolution of diagnostic techniques is critical to prevent the spread of viruses and the development of viral reservoirs in the swine industry that impact the possible development of future pandemics and the world economy.

6.
Biosensors (Basel) ; 12(12)2022 Nov 25.
Artículo en Inglés | MEDLINE | ID: mdl-36551045

RESUMEN

The synergistic potentialities of innovative materials that include aptamers have opened new paradigms in biosensing platforms for high-throughput monitoring systems. The available nucleobase functional moieties in aptamers offer exclusive features for bioanalytical sensing applications. In this context, compared to various in-practice biological recognition elements, the utilization of aptamers in detection platforms results in an extensive range of advantages in terms of design flexibility, stability, and sensitivity, among other attributes. Thus, the utilization of aptamers-based biosensing platforms is extensively anticipated to meet unaddressed challenges of various in-practice and standard analytical and sensing techniques. Furthermore, the superior characteristics of aptasensors have led to their applicability in the detection of harmful pollutants present in ever-increasing concentrations in different environmental matrices and water bodies, seeking to achieve simple and real-time monitoring. Considering the above-mentioned critiques and notable functional attributes of aptamers, herein, we reviewed aptamers as a fascinating interface to design, develop, and deploy a new generation of monitoring systems to aid modern bioanalytical sensing applications. Moreover, this review aims to summarize the most recent advances in the development and application of aptasensors for the detection of various emerging pollutants (EPs), e.g., pharmaceutical, and personal care products (PPCPs), endocrine-disrupting chemicals (EDCs), pesticides and other agricultural-related compounds, and toxic heavy elements. In addition, the limitations and current challenges are also reviewed, considering the technical constraints and complexity of the environmental samples.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Contaminantes Ambientales , Plaguicidas , Aptámeros de Nucleótidos/química , Contaminantes Ambientales/análisis , Técnicas Biosensibles/métodos
7.
Biosensors (Basel) ; 12(3)2022 Mar 17.
Artículo en Inglés | MEDLINE | ID: mdl-35323449

RESUMEN

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) caused the ongoing COVID-19 (coronavirus disease-2019) outbreak and has unprecedentedly impacted the public health and economic sector. The pandemic has forced researchers to focus on the accurate and early detection of SARS-CoV-2, developing novel diagnostic tests. Among these, microfluidic-based tests stand out for their multiple benefits, such as their portability, low cost, and minimal reagents used. This review discusses the different microfluidic platforms applied in detecting SARS-CoV-2 and seroprevalence, classified into three sections according to the molecules to be detected, i.e., (1) nucleic acid, (2) antigens, and (3) anti-SARS-CoV-2 antibodies. Moreover, commercially available alternatives based on microfluidic platforms are described. Timely and accurate results allow healthcare professionals to perform efficient treatments and make appropriate decisions for infection control; therefore, novel developments that integrate microfluidic technology may provide solutions in the form of massive diagnostics to control the spread of infectious diseases.


Asunto(s)
Técnicas Biosensibles/métodos , COVID-19/diagnóstico , Microfluídica , SARS-CoV-2/aislamiento & purificación , Anticuerpos Antivirales/sangre , COVID-19/epidemiología , Humanos , Sistemas de Atención de Punto , Pruebas en el Punto de Atención , SARS-CoV-2/inmunología , Estudios Seroepidemiológicos
8.
Sci Rep ; 11(1): 4327, 2021 02 22.
Artículo en Inglés | MEDLINE | ID: mdl-33619337

RESUMEN

COVID-19, the first pandemic of this decade and the second in less than 15 years, has harshly taught us that viral diseases do not recognize boundaries; however, they truly do discriminate between aggressive and mediocre containment responses. We present a simple epidemiological model that is amenable to implementation in Excel spreadsheets and sufficiently accurate to reproduce observed data on the evolution of the COVID-19 pandemics in different regions [i.e., New York City (NYC), South Korea, Mexico City]. We show that the model can be adapted to closely follow the evolution of COVID-19 in any large city by simply adjusting parameters related to demographic conditions and aggressiveness of the response from a society/government to epidemics. Moreover, we show that this simple epidemiological simulator can be used to assess the efficacy of the response of a government/society to an outbreak. The simplicity and accuracy of this model will greatly contribute to democratizing the availability of knowledge in societies regarding the extent of an epidemic event and the efficacy of a governmental response.


Asunto(s)
COVID-19/epidemiología , Brotes de Enfermedades/estadística & datos numéricos , Pandemias/estadística & datos numéricos , SARS-CoV-2/patogenicidad , Epidemias/estadística & datos numéricos , Humanos , México/epidemiología , Ciudad de Nueva York/epidemiología , República de Corea/epidemiología
9.
Biosensors (Basel) ; 11(10)2021 Oct 13.
Artículo en Inglés | MEDLINE | ID: mdl-34677342

RESUMEN

Loop-mediated isothermal amplification (LAMP) has been recently studied as an alternative method for cost-effective diagnostics in the context of the current COVID-19 pandemic. Recent reports document that LAMP-based diagnostic methods have a comparable sensitivity and specificity to that of RT-qPCR. We report the use of a portable Arduino-based LAMP-based amplification system assisted by pH microelectrodes for the accurate and reliable diagnosis of SARS-CoV-2 during the first 3 min of the amplification reaction. We show that this simple system enables a straightforward discrimination between samples containing or not containing artificial SARS-CoV-2 genetic material in the range of 10 to 10,000 copies per 50 µL of reaction mix. We also spiked saliva samples with SARS-CoV-2 synthetic material and corroborated that the LAMP reaction can be successfully monitored in real time using microelectrodes in saliva samples as well. These results may have profound implications for the design of real-time and portable quantitative systems for the reliable detection of viral pathogens including SARS-CoV-2.


Asunto(s)
COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , SARS-CoV-2/genética , COVID-19/virología , Proteínas de la Nucleocápside de Coronavirus/genética , Humanos , Microelectrodos , Técnicas de Diagnóstico Molecular/instrumentación , Técnicas de Amplificación de Ácido Nucleico/instrumentación , Fosfoproteínas/genética , Sistemas de Atención de Punto , ARN Viral/análisis , ARN Viral/metabolismo , Tiempo de Reacción , SARS-CoV-2/aislamiento & purificación , Saliva/virología
10.
Anal Methods ; 13(2): 169-178, 2021 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-33399137

RESUMEN

We demonstrate a loop-mediated isothermal amplification (LAMP) method to detect and amplify SARS-CoV-2 genetic sequences using a set of in-house designed initiators that target regions encoding the N protein. We were able to detect and amplify SARS-CoV-2 nucleic acids in the range of 62 to 2 × 105 DNA copies by this straightforward method. Using synthetic SARS-CoV-2 samples and RNA extracts from patients, we demonstrate that colorimetric LAMP is a quantitative method comparable in diagnostic performance to RT-qPCR (i.e., sensitivity of 92.85% and specificity of 81.25% in a set of 44 RNA extracts from patients analyzed in a hospital setting).


Asunto(s)
Prueba de Ácido Nucleico para COVID-19/métodos , Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , ARN/análisis , SARS-CoV-2/química , Carga Viral/métodos , COVID-19/diagnóstico , Colorimetría/métodos , Proteínas de la Nucleocápside de Coronavirus , ADN/análisis , ADN/química , Colorantes Fluorescentes/química , Humanos , Sustancias Intercalantes/química , Fenolsulfonftaleína/química , Fosfoproteínas , ARN/química
11.
Diagnostics (Basel) ; 11(2)2021 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-33578665

RESUMEN

Massive worldwide serological testing for SARS-CoV-2 is needed to determine the extent of virus exposure in a particular region, the ratio of symptomatic to asymptomatic infected persons, and the duration and extent of immunity after infection. To achieve this, the development and production of reliable and cost-effective SARS-CoV-2 antigens is critical. We report the bacterial production of the peptide S-RBDN318-V510, which contains the receptor-binding domain of the SARS-CoV-2 spike protein (region of 193 amino acid residues from asparagine-318 to valine-510) of the SARS-CoV-2 spike protein. We purified this peptide using a straightforward approach involving bacterial lysis, his-tag-mediated affinity chromatography, and imidazole-assisted refolding. The antigen performances of S-RBDN318-V510 and a commercial full-length spike protein were compared in ELISAs. In direct ELISAs, where the antigen was directly bound to the ELISA surface, both antigens discriminated sera from non-exposed and exposed individuals. However, the discriminating resolution was better in ELISAs that used the full-spike antigen than the S-RBDN318-V510. Attachment of the antigens to the ELISA surface using a layer of anti-histidine antibodies gave equivalent resolution for both S-RBDN318-V510 and the full-length spike protein. Results demonstrate that ELISA-functional SARS-CoV-2 antigens can be produced in bacterial cultures, and that S-RBDN318-V510 may represent a cost-effective alternative to the use of structurally more complex antigens in serological COVID-19 testing.

12.
PLoS One ; 15(8): e0237418, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32790779

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic has crudely demonstrated the need for massive and rapid diagnostics. By the first week of July, more than 10,000,000 positive cases of COVID-19 have been reported worldwide, although this number could be greatly underestimated. In the case of an epidemic emergency, the first line of response should be based on commercially available and validated resources. Here, we demonstrate the use of the miniPCR, a commercial compact and portable PCR device recently available on the market, in combination with a commercial well-plate reader as a diagnostic system for detecting genetic material of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causal agent of COVID-19. We used the miniPCR to detect and amplify SARS-CoV-2 DNA sequences using the sets of initiators recommended by the World Health Organization (WHO) for targeting three different regions that encode for the N protein. Prior to amplification, samples were combined with a DNA intercalating reagent (i.e., EvaGreen Dye). Sample fluorescence after amplification was then read using a commercial 96-well plate reader. This straightforward method allows the detection and amplification of SARS-CoV-2 nucleic acids in the range of ~625 to 2×105 DNA copies. The accuracy and simplicity of this diagnostics strategy may provide a cost-efficient and reliable alternative for COVID-19 pandemic testing, particularly in underdeveloped regions where RT-QPCR instrument availability may be limited. The portability, ease of use, and reproducibility of the miniPCR makes it a reliable alternative for deployment in point-of-care SARS-CoV-2 detection efforts during pandemics.


Asunto(s)
Betacoronavirus/genética , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/diagnóstico , Sistemas de Atención de Punto , Reacción en Cadena de la Polimerasa/instrumentación , Reacción en Cadena de la Polimerasa/métodos , Secuencia de Bases , Betacoronavirus/química , COVID-19 , Infecciones por Coronavirus/virología , Proteínas de la Nucleocápside de Coronavirus , ADN Viral/genética , Exactitud de los Datos , Humanos , Proteínas de la Nucleocápside/genética , Pandemias , Fosfoproteínas , Neumonía Viral/virología , Reacción en Cadena de la Polimerasa/economía , Reproducibilidad de los Resultados , SARS-CoV-2 , Sensibilidad y Especificidad
13.
Nanomaterials (Basel) ; 10(11)2020 Nov 06.
Artículo en Inglés | MEDLINE | ID: mdl-33172181

RESUMEN

Pyrolysis is a feasible solution for environmental problems related to the inadequate disposal of waste tires, as it leads to the recovery of pyrolytic products such as carbon black, liquid fuels and gases. The characteristics of pyrolytic carbon black can be enhanced through chemical activation in order to produce the required properties for its application. In the search to make the waste tire pyrolysis process profitable, new applications of the pyrolytic solid products have been explored, such as for the fabrication of energy-storage devices and precursor in the synthesis of nanomaterials. In this study, waste tires powder was chemically activated using acid (H2SO4) and/or alkali (KOH) to recover pyrolytic carbon black with different characteristics. H2SO4 removed surface impurities more thoroughly, improving the carbon black's surface area, while KOH increased its oxygen content, which improved the carbon black's stability in water suspension. Pyrolytic carbon black was fully characterized by elemental analysis, inductively coupled plasma-optical emission spectrometry (ICP-OES), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, X-ray diffraction (XRD), N2 adsorption/desorption, scanning electron microscopy-energy-dispersive X-ray spectroscopy (SEM-EDS), dynamic light scattering (DLS), and ζ potential measurement. In addition, the pyrolytic carbon black was used to explore its feasibility as a precursor for the synthesis of carbon dots; synthesized carbon dots were analyzed preliminarily by SEM and with a fluorescence microplate reader, revealing differences in their morphology and fluorescence intensity. The results presented in this study demonstrate the effect of the activating agent on pyrolytic carbon black from waste tires and provide evidence of the feasibility of using waste tires for the synthesis of nanomaterials such as carbon dots.

14.
PLoS One ; 14(5): e0215642, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31071117

RESUMEN

The development of point-of-care (POC) diagnostic systems has received well-deserved attention in recent years in the scientific literature, and many experimental systems show great promise in real settings. However, in the case of an epidemic emergency (or a natural disaster), the first line of response should be based on commercially available and validated resources. Here, we compare the performance and ease of use of the miniPCR, a recently commercially available compact and portable PCR device, and a conventional thermocycler for the diagnostics of viral nucleic acids. We used both thermocyclers to detect and amplify Ebola and Zika DNA sequences of different lengths (in the range of 91 to 300 nucleotides) at different concentrations (in the range of ~50 to 4.0 x 108 DNA copies). Our results suggest that the performance of both thermocyclers is quite similar. Moreover, the portability, ease of use, and reproducibility of the miniPCR makes it a reliable alternative for point-of-care nucleic acid detection and amplification.


Asunto(s)
Fiebre Hemorrágica Ebola/diagnóstico , Reacción en Cadena de la Polimerasa/instrumentación , ARN Viral/genética , Infección por el Virus Zika/diagnóstico , Ebolavirus/genética , Ebolavirus/aislamiento & purificación , Humanos , Miniaturización/instrumentación , Sistemas de Atención de Punto , Virus Zika/genética , Virus Zika/aislamiento & purificación
15.
PLoS One ; 10(10): e0135859, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26489048

RESUMEN

BACKGROUND: Current Ebola virus (EBOV) detection methods are costly and impractical for epidemic scenarios. Different immune-based assays have been reported for the detection and quantification of Ebola virus (EBOV) proteins. In particular, several monoclonal antibodies (mAbs) have been described that bind the capsid glycoprotein (GP) of EBOV GP. However, the currently available platforms for the design and production of full-length mAbs are cumbersome and costly. The use of antibody fragments, rather than full-length antibodies, might represent a cost-effective alternative for the development of diagnostic and possibly even therapeutic alternatives for EBOV. METHODS/PRINCIPAL FINDINGS: We report the design and expression of three recombinant anti-GP mAb fragments in Escherichia coli cultures. These fragments contained the heavy and light variable portions of the three well-studied anti-GP full-length mAbs 13C6, 13F6, and KZ52, and are consequently named scFv-13C6, scFv-13F6, and Fab-KZ52, respectively. All three fragments exhibited specific anti-GP binding activity in ELISA experiments comparable to that of full-length anti-GP antibodies (i.e., the same order of magnitude) and they are easily and economically produced in bacterial cultures. CONCLUSION/SIGNIFICANCE: Antibody fragments might represent a useful, effective, and low cost alternative to full-length antibodies in Ebola related capture and diagnostics applications.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Anticuerpos Antivirales/inmunología , Ebolavirus/inmunología , Glicoproteínas/metabolismo , Fiebre Hemorrágica Ebola/diagnóstico , Fragmentos de Péptidos/metabolismo , Proteínas del Envoltorio Viral/metabolismo , Ensayo de Inmunoadsorción Enzimática , Glicoproteínas/inmunología , Fiebre Hemorrágica Ebola/metabolismo , Fiebre Hemorrágica Ebola/virología , Humanos , Fragmentos de Péptidos/inmunología , Proteínas Recombinantes/inmunología , Proteínas Recombinantes/metabolismo , Proteínas del Envoltorio Viral/inmunología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA